LINEAR LINK QUICK REFERENCE MANUAL Basic Installation, Programming & Troubleshooting

Similar documents
INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Installation, Operation and Maintenance Manual

CEC VIBRATION TRANSMITTER

TECHNICAL NOTES MT-4 Radio Systems TN182 Battery Level Reporting and Remote P25 Test Tone

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Installation & Service Manual

OVEN INDUSTRIES, INC. Model 5C7-362

Guardian and DL3282 Modem Interface Technical Service Application Note

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

INSTRUCTION MANUAL PLUG AND SEND WIRELESS MONITOR SYSTEM TABLE OF CONTENTS

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

1-830 SERIES DISPLACEMENT TRANSMITTER

Installation, Operation and Maintenance Manual

Underwater GPS User Manual

Temposonics. M-Series Analogue/PWM Tester. User s Manual. Absolute, Non-Contact Position Sensors. Document Part Number Revision B

Introduction to the Analog Discovery

Operating Instructions

IB6 Series Solid-State Isolation Relay

OBSOLETE A. For 24-hour Technical Assistance Call

Programmable K-Factor Scaler B and Programming Software Kit B

TECHNICAL NOTES. MT-4 Radio Systems. TN247 VR-4E VHF MT-4E Receiver. Specifications. Models Available. Receiver Operating Frequency

Instruction Manual ABM HART Gateway Software. Instruction Manual Revision A.1

Sensor Options. Rev

TECHNICAL INFORMATION BULLETIN

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

Wireless Base Radio. Wireless Transmitters

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

LPB OMNI Broadcast Transmitter Installation Procedure Checklist

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Underwater GPS User Manual

Models included: GEO EDGE

Scorpion Antennas Controller. Instruction Manual. Firmware V11.8 November Please Read This Manual Completely Before Operating The Controller

INSTALLATION & OPERATION MANUAL

SCXI TERMINAL BLOCK

NEW DESIGN***DEM Part Number FRS***NEW DESIGN Low power 144 MHz Transverter for the Flex Radio System SDR-1000 Operating Specifications:

ArbStudio Training Guide

ANI-F-KW1. Multi-Format ANI Encoder For Kenwood Radios. Manual Revision: Covers Software Revisions: ANI-F: 1.

Proximity Transmitters and Seismic Vibration Transmitters

Ortel (Lucent) Fiber Optic Interface AC

Sutron SatLink2 Troubleshooting Instructions

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

EDACS WALL MOUNT STATION. Maintenance Manual. Mobile Communications LBI-31838A TABLE OF CONTENTS

Wireless 900 MHz Receiver

HUMITRAN-RHT & RH RELATIVE HUMIDITY/TEMPERATURE TRANSMITTER RELATIVE HUMIDITY TRANSMITTER

JCM TRAINING OVERVIEW WBA-XX

SPECIAL SPECIFICATION 1257 Digital Card Rack Non-Invasive Micro Loop Detector Assembly (8 Slot Rack)

MODEL AT-10 ANALOG TRANSMITTER

AD-8100 & AD-8200 Servo Amplifiers

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

GTS High Frequency Pulser. Technical Bulletin

G SERIES PRECISION METERS

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

The wireless alternative to expensive cabling...

Servo Amplifier - Troubleshooting Guide

Ground Loops and other Buzz

CAME QP- V4.4 SPECIFICATION STANDARDS CABLE PLAN CABLE TYPES Z SERIES AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

Dec, Hytera Customer Service Express

Product Specification for model TT Transducer Tester Rev. B

Advanced Test Equipment Rentals ATEC (2832) Contents

200GTL ALIGNMENT REVISION: 1.0 BURKE MODEL: 200GTL REVISION: 1.2 DATE: 02/14/06. Total Pages: 6 pages. Page:1 print date: 9/23/09

Magnetic Flowmeter Simulator

LPU-2127 User Manual

Maintenance Manual. MTD SERIES 900 MHz, 10-WATT, DATA ONLY MOBILE RADIO. Mobile Communications LBI TABLE OF CONTENTS

NCS-C151 INSTRUCTION MANUAL Rev B. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

VOLTAGE. User Guide ACCESSORIES. External Sensor DT140. for MicroLog EC600 and EC V ±0.05V ±3% (before calibration)

Issue No: MG025 Date: 05 June McMurdo SmartFind R5 GMDSS Radio IMO MSC. 1/Circ Update procedure

Non-Contact Sensing Reduces Wear, Breakage, Downtime, and Ultimately, Cost

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

Ortel (Lucent) Fiber Optic Interface

M2M i-link POINT-TO-MULTIPOINT INSTALLATION INSTRUCTIONS

Dual Band Filter Assembly Manual

SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

Global Water Instrumentation, Inc.

Mass and Volume Flow Transmitter

E7000, E7500, and E ma Analog Transmitters

GPS Evaluation Kit EVA1035-H

ALX-SSB 5 Band Filter Assembly Manual 19 November 2018

ANTENNAFIER TM 915LTX BLOCK DIAGRAM LNA

MDX420 Input Level Field Calibration Procedure AN227 Rev. 1.0

LUDLUM MODEL 421 AND PMT BASE WITH PREAMPLIFIER/BIAS SUPPLY. October 2014 Serial Number and Succeeding Serial Numbers

Welcome at MR Achieva 3.0T TX. About the system. Index. 1.1 Introduction

The first RADIO Communication Module designed for the weighing industry

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

Ameritron ALS-600 Retrofit ALS-600-LPF Assembly Manual

Ortel (Lucent) Fiber Optic Interface

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

Input Voltage. Current Draw. Output. Resolution Internal Analog Output. Linearity. Repeatability. Hysteresis +/-.02% of Full Scale. Operating Pressure

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

EVDP610 IXDP610 Digital PWM Controller IC Evaluation Board

AirScope Spectrum Analyzer User s Manual

Transcription:

8930 S Beck Ave., Suite 107 Tempe, Arizona 85284 U.S.A. Telephone (480) 240-3400 Fax (480) 240-3401 www.ftimeters.com LINEAR LINK QUICK REFERENCE MANUAL Basic Installation, Programming & Troubleshooting The specifications contained in this manual are subject to change without notice and any user of these specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications that have been changed and are no longer in effect. TM-69313 REV. A PUBLISHED BY FLOW TECHNOLOGY, INC. July 2008

TM-39613 REVISIONS TM-69313 Linear Link Quick Reference Manual Page 2 of 12

Table of Contents Wiring / Set Up Wiring set up...page 4 Output Connections & Definitions...Page 5 Programming Visual Link Program Install/Setup...Page 7 Changing Units for Mass Flow or Volumetric...Page 9 Editing, Saving & Loading Job Files...Page 11 Troubleshooting Linear Link Troubleshooting...Page 12 Wiring/Setup TM-69313 Linear Link Quick Reference Manual Page 3 of 12

Step# 1 - Determine the model # of the Linear Link. LN - 5 - C - V1-1 POWER 5 = 10 TO 32 VDC FLOW METER INPUT A = MAGNETIC B = PULSE C = RF CARRIER D = OTHER RF CARRIER ENCLOSURE -0 = NO ENCLOSURE B6 = NEMA 4X B7 = NEMA 4X WITH MS CONNECTOR -9 = CLASS 1, DIV, GROUP A, B, C & D A7 = DUST TIGHT ALUMINUM WITH MS CONNECTOR -F = CLASS 1, DIV 1, GROUP B, C & D -1 = INTEGRAL PICKOFF, 10-PIN MS BA = NEMA 4X, UNIVERSAL DISPLAY, MX CONN BC = NEMA 4X, UNIVERSAL DISPLAY ANALOG OUTPUT V1 = ANALOG VOLTAGE (0 TO 10 VDC) FOR FLOW RATE MA = ANALOG CURRENT (4 TO 20 ma) FOR FLOW RATE Step# 2 Wire the Linear Link according to the appropriate table. (Table 4 explains the inputs & outputs) LN- 5 - - - 1- Table 1 LN- 5 - - - 9 - Table 2 LN- 5 - - -BC - Table 2 LN- 5 - - -B6 - Table 2 LN- 5 - - - F - Table 2 LN- 5 - - -B7 - Table 3 LN- 5 - - -A7 - Table 3 LN- 5 - - -BA - Table 3 Step# 3 Verify the output by putting flow through the meter and monitoring the output. The Linear Link has been programmed at the factory with the calibration data for the meter. There is no need to reprogram the unit (unless instructed to by FTI). If there is no output from the Linear Link go to the troubleshooting guide at the end of this manual. Step# 4 You re done! The Linear Link is ready for use. TM-69313 Linear Link Quick Reference Manual Page 4 of 12

Output Connections & Definitions Table 1: Electrical Connections, Pickoff Version (For models, LN- 5 - - - 1- ) Linear Link Function Pin (10- Pin Connector) POWER +10 to +32 VDC (Supply) A CIRCUIT COMMON Power and Signal Common B TX Serial Transmit Data C RX Serial Receive Data D F LIN Linearized Pulse Output E F RAW Non-Linearized Pulse Output F VOLTAGE OUT Voltage Out G CURRENT OUT Current Out H NOT USED NOT USED J K Table 2: Electrical Connections, NEMA 4X & Condulet Versions (For models, LN- 5 - - - 9 -, LN- 5 - - - BC -, LN- 5 - - - B6 - LN- 5 - - - F - ) Linear Link Function Terminal Strip (NEMA 4X and Metal Conduit) Version (PCB 12-Pin) POWER +10 to +32 VDC (Supply) 1 POWER RETURN Power Return 2 + XDCR Pickoff Input 3 - XDCR Pickoff Input 4 F LIN Linearized Pulse Output 5 F RAW Non-Linearized Pulse Output 6 VOLTAGE OUT Voltage Out 7 CURRENT OUT Current Out 8 CIRCUIT COMMON 9, 10, 11, 12 TM-69313 Linear Link Quick Reference Manual Page 5 of 12

Table 3: Electrical Connections, NEMA 4X with 3-pin & 10-pin MS Connectors (For models, LN- 5 - - -B7 -, LN- 5 - - -A7 -, LN- 5 - - - BA - ) Linear Link Function Terminal Strip PCB (Pin #) MS (NEMA 4X & Aluminum) Version (10-Pin, J1 and 3-pin, J2) POWER +10 to +32 VDC (Supply) 1 J1-A POWER RETURN Power Return 2 J1-B F LIN Linearized Pulse Output 5 J1-C F RAW Non-Linearized Pulse Output 6 J1-D VOLTAGE OUT Voltage Out 7 J1-E CURRENT OUT Current Out 8 J1-F CIRCUIT COMMON 9 J1-G CIRCUIT COMMON 11 J1-H + XDCR Pickoff Input 3 J2-A - XDCR Pickoff Input 4 J2-B CIRCUIT COMMON 10 J2-C Table 4: Link Outputs The linearized scaled flowrate output is available as a analog and pulse signal output F Lin F Raw Voltage Out Current Out Linearized pulse output (5 Volt amplitude). This pin has a pulse output signal that corresponds to the linearized flow. Unscaled pulse output (5 Volt amplitude). This pin has the amplified output signal of the flowmeter before linearization. This is useful for monitoring the raw frequency generated by the flowmeter. It can also be used to inject a pulse for verifying calibrations. Pulse input (0-5 Volt amplitude, absolute max of 10V). This is the input pin for pulse input flowmeters. 0-10 Volt output. This pin provides an analog voltage output signal that corresponds to the linearized flowrate. 4-20mA output. This pin provides an analog milliamp output signal that corresponds to the linearized flowrate. Use only on units configured for current output. This output is locally powered and must be returned to the common pin not to a voltage source. TM-69313 Linear Link Quick Reference Manual Page 6 of 12

Visual Link Program Install/Set Up NOTE: The only time the Visual Link software should be used is to modify or rescale the Linear Link programming. It is not intended to be used as a troubleshooting tool. Step# 1 Download and install the software. Visual Link Software is available from the FTI website at www.ftimeters.com. Step# 2 Hook up the smart cable from the computer to the Linear Link. Smart Cable Part# 19-61348-104 is used on the pickoff version of the Linear Link (MS connector). Smart Cable Part# 19-61348-102 is used on all other Linear Link models (modular connector). Step# 3 Establish a connection with the Linear Link using the Visual Link Software Establish Communication Button on the Connection Status tab (circled below). TM-69313 Linear Link Quick Reference Manual Page 7 of 12

Step# 4 - Transfer the data from the Linear Link to the Visual Link software by clicking the read EPROM button (circled below). Once the button is clicked, press ok and the data will transfer. When the data is transferred click close button. Step# 5 Make any changes. Changes must be saved to the computer as a new.job file. Step# 6 Transfer the data to the Linear Link. The new information can be transferred to the Linear Link by clicking the transmit button (circled below). When completed click the close button. TM-69313 Linear Link Quick Reference Manual Page 8 of 12

Changing Units for Mass Flow or Volumetric Step# 1 - Connect to the Linear Link as described on page 6. Step# 2 -Open the System Parameters tab Step# 3 - In the System Parameters tab, change the units where it indicates Flow Output Units. If changing the time base (minutes to hours) the K-Factor units will need to be changed. If time base remains the same then only the Flow Output Units will need to be modified. TM-69313 Linear Link Quick Reference Manual Page 9 of 12

Step# 4 - If the time base is changing, the K-Factor units will need to be changed. Select Configure on the toolbar and then select the Mechanical Parameters. Step# 5 - In the Mechanical Parameters screen; change the time base units only. Step# 6 - Save the job file and write it to the EPROM in the Linear Link. TM-69313 Linear Link Quick Reference Manual Page 10 of 12

Editing, Saving & Loading Job Files Step# 1 - Connect to and transfer the data from the Linear Link as described on page 6. Step# 2 Save the data to a.job file. It is recommended to save the original data to a.job file before making any changes. This allows recovery if any mistakes are made. Step# 3 - Make the changes to the configuration. Once the changes are made, save the modified data to a new.job file. Step# 4 - Program the job information into the Linear Link EPROM (see page 8 for transferring data to the Linear Link ). Note: To obtain a copy of the original.job file, contact FTI @ 1-800-528-4225.. TM-69313 Linear Link Quick Reference Manual Page 11 of 12

Linear Link Trouble Shooting TM-69313 Linear Link Quick Reference Manual Page 12 of 12