w ww.osram.us/optotronic OPTOTRONIC LED Power Supply OTi 50W DEXAL TM Programmable - Technical Specifications ELECTRICAL SPECIFICATIONS Input Input Voltage (VAC) 120V-277V (+/- 10%) Frequency Range (Hz) 50 60 Hz (+/- 10%) 120V 277V Input Current (A) 0.51 0.22 THD @ Full Load <20% <20% Power Factor @ Full Load >0.9 >0.9 Efficiency @ Full Load >86% >86% Inrush Current (Apk) 15.5 40.3 Output Output Current (ma) 600- (1mA step) Output Voltage (VDC) 10-56VDC Output Ripple Current <20% @ Max. Output power (W) 50W LED Power Up Time <1sec Load Regulation <5% Line Regulation <5% Over Voltage Protection Yes, non-latching Over Load Protection Yes, non-latching Output Short-Circuit Protection Yes, non-latching Over Temperature Protection Foldback at 95⁰C LED Thermal Protection (NTC) NTC Value Active Range 25kΩ Output level minimum User defined GENERAL INFORMATION Item Number 78034 Type Constant Current, Class 2 Output Power 50W (Max.) Programming Tool 51645 & 51647/51648 Software Programmable Features Download Output current Dimming: Linear & Log. DEXAL LED thermal protection Constant lumen output End-of-life indicator DIMMING SPECIFICATIONS Dimming Control DEXAL (Digital Dimming) Dimming Range 1-100% Dimming Type Voltage Rating (DEXAL) Peak Current (DEXAL) Dim-to-Off Threshold Standby Power 2 Analog 12V typ. 125mA max 0 (digital Level) 0.40W(120V); 0.55W(277V) ENVIRONMENTAL SPECIFICATIONS Ambient Operating Temperature -30ºC to 50ºC Case Temperature (Tc) 75ºC (50kHrs) 3 Max. Storage Temp. 70ºC Max. Relative Humidity (%) 85% non-condensing Transient Protection NEMA SSL1-2010 Non-Roadway 2.5KV UL Rating Dry & Damp IEC IEC 61347-1 EMI Compliance FCC Part 15 Class A Sound Rating Class A 1- The lowest output current is 6mA and the minimum percentage of dimming is dependent on the programmed output current of the driver 2- This does not include the sensor power in DEXAL mode. 3- Warranty applicable only at 75ºC ECS301 6/2017 1
DATA EXCHANGE The default setting of the digital dimming interface is set to DEXAL that delivers power to sensors and the following data: o Input Power Consumption: 2% accuracy above 10W threshold. o Operating Time: Updated rate 1 min o Max. Case Temperature: ± 5 C accuracy o Current Case Temperature: ± 5 C accuracy When using DALI 1.0 systems, choose the DALI option in the programming software. This will turn off the power delivery on the DEXAL interface. The interface is non-polarized in this mode. WIRING DIAGRAM Note 1: Maximum suggested remote mounting distance is 16 feet. MECHANICAL DIAGRAM MECHANICAL SPECIFICATIONS Length 14.20 (280mm) Width Height Mounting Length 1.15 (29.4mm) 1.0 (25.4mm) 13.77 (270mm) ECS301 6/2017 2
Outpu Voltage (V) OPERATING RANGE 60 50 40 30 20 10 0 400 600 800 1000 1200 1400 1600 Output Current (ma) PF>0.9 and THD <20% Note: Meeting DLC requirements requires minimum 50% loading ECS301 6/2017 3
% of Output Current % of Output Current DIMMING CURVES Linear Dimming Curve 100 90 80 70 60 50 40 30 20 10 0 0 50 100 150 200 250 300 DALI LEVEL (1-254) Logarithmic Dimming Curve 100 90 80 70 60 50 40 30 20 10 0 0 50 100 150 200 250 300 DALI LEVEL (1-254) ECS301 6/2017 4
Power Factor THD (%) THD VS INPUT VOLTAGE (FULL LOAD) 10 8 6 4 2 0 100 120 140 160 180 200 220 240 260 280 300 Input Voltage (V) POWER FACTOR VS INPUT VOLTAGE (FULL LOAD) 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 0.90 100 120 140 160 180 200 220 240 260 280 300 Input Voltage (VAC) ECS301 6/2017 5
Efficiency (%) Efficiency (%) EFFICIENCY VS OUTPUT VOLTAGE Efficiency @ 120V 90 88 86 84 82 80 78 76 74 72 70 5 15 25 35 45 55 65 Output Voltage (V) Efficiency @ 277V 95 90 85 80 75 70 5 15 25 35 45 55 65 Output Voltage (V) ECS301 6/2017 6
Power Factor Power Factor POWER FACTOR VS LOAD 1.00 0.99 0.98 0.97 0.96 Power Factor vs Output Power (120V) 0.95 0.94 0.93 0.92 0.91 0.90 0 10 20 30 40 50 60 Output Power (W) Power Factor vs Output Power (277V) 1.00 0.99 0.98 0.97 0.96 0.95 0.94 0.93 0.92 0.91 0.90 0 10 20 30 40 50 60 Output Power (W) ECS301 6/2017 7
THD (%) THD (%) THD VS LOAD THD vs Output Power (120V) 20.0 18.0 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 0.0 0 10 20 30 40 50 60 Output Power (W) THD vs Output Power (277V) 20.0 18.0 16.0 14.0 12.0 10.0 8.0 6.0 4.0 2.0 0.0 0 10 20 30 40 50 60 Output Power (W) ECS301 6/2017 8
% Of Output Current LED THERMAL PROTECTION (NTC) CHARACTERISTIC The LED thermal protection feature of the OTi 50W helps reduce the temperature of the LED module by reducing the output current in case of abnormal temperature conditions. To use this feature, a third party NTC thermistor should be connected to the LED power supply as shown in the wiring diagram below. In the end application, care must be taken to place the NTC thermistor close to the hottest spot on the LED module. If LED thermal protection is not required the NTC port on the LED power supply connector can be left open. Vishay, EPCOS, Murata, Panasonic are some of the manufacturers of NTC thermistor. EPCOS part number for reference only B57164K153J (15kΩ @ 25 C). Murata part number for reference only - NCP03XH223J05RL (22kΩ @ 25 C) Note 3: Graphs for reference. The derating limits can be programmed using the OT Programmer 100 Derating start = 6.3kΩ; Derating end = 4.3kΩ; Min output level = 10% 80 60 40 20 0 6.5 6 5.5 R NTC in kω 5 4.5 4 CONSTANT LUMEN MAINTENANCE The Constant Lumen Maintenance feature of the OTi 50W helps to maintain the required lumen output of the fixture at a constant level throughout its lifetime. In general LED s lumen output will depreciate over time and in order to maintain sufficient light level towards the end of lifetime, the LED s are driven at high current initially and will result in more energy consumption. The constant lumen maintenance will give the flexibility to drive the LEDs at optimal driving current throughout its lifetime. This helps in energy savings, constant light output and enhanced reliability of the system. END-OF-LIFE INDICATOR The End-of-Life indicator helps the end user to receive a signal from the fixture indicating that it has reached its programmed life-time. After the LED driver reaches the programmed life-time, whenever it is turned ON, it stays at Dim level (10%) for 10 minutes and reaches its appropriate level. ECS301 6/2017 9
INRUSH CHARACTERISTICS Vin (V) Ipeak (A) T (@ 50% of Ipeak) 120 15.5 180µs 277 40.3 195µs Complies to NEMA 410 inrush current requirements DIMMER/SENSOR COMPATIBILITY Manufacturer Part no OSRAM ZBHA-CLM DEXAL (NAED: 57400) Enlighted Inc. FS-D22 (Two-wire Fixture Mount Sensor) Note 4: The absence of a dimmer from this chart does not necessarily imply incompatibility. Please reference the dimmer manufacturer s instructions for installation. WARRANTY OPTOTRONIC products are covered by our LED Module, OPTOTRONIC Power Supply or Control Warranty. For additional details, refer to the latest version of the warranty (LED395) available at www.osramamericas.com/optotronic. ECS301 6/2017 10