ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Similar documents
ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

ATV12H018M3 frekv.pretvarač promj.brzine ATV12 0,18 KW 0,25 ks V 3 faze

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATS01N222LU soft starter for asynchronous motor - ATS01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATS01N106FT soft starter for asynchronous motor - ATS01-6 A V KW

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

Altivar 28 drive Altivar 28 enclosed drive

Introduction (continued) Altivar 12 variable speed drives

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

RE17LLBM asymmetrical flashing relay s V AC - solid state output

References 1 for asynchronous motors 1

VW3A4556 line choke mh A - 3 phases W - for variable speed drive

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

ZBRRA Programmable receiver - 2 relays V AC/ DC - 2 pusbuttons - 6 LEDs

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

Zelio Control Measurement Relays

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

RXG21BD interface plug-in relay - Zelio RXG - 2 C/O standard - 24V DC - 5A - with LTB

RE7TP13BU adjustable on-delay timing relay s - 24 V AC DC - 2OC

ZBRT2 double actions (up/down) transmitter for wireless and battery less pushbutton

RENF22R2MMW Zelio Timer Relay - Modular

RE7RL13BU off-delay timing relay with control contact s - 24 V AC DC - 2OC

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

This Chapter contains:

02/11/2015

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

02/11/2015

Protection components

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

02/11/2015

Custom "Compact" range with display CD20 Custom Part number

ACH550 HVAC Drive Submittal

VW3A4552. Price* : USD. ATV31CU22N4 - motor choke - 1 per drive. ATV31CU22N4 - line choke - 1 per drive

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

02/11/2015

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

RXG12BD interface plug-in relay - Zelio RXG - 1C/O standard - 24VDC-10A-with LTB and LED

RE22R2MYMR Multi-function Timing Relay s 300h V AC/DC - 2C/O

User's Guide for type ACS55 AC Drives from 0.18 to 2.2 kw

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

02/11/2015

CP-T range Product group picture

S11 Adjustable Speed Drive Engineering Specification

em4 em4 alert em4 alert 2G

140MSB10100 single axis motion module - 1 axis real, 1 axis remote - differential encoder 5V

VW3A4554 line/motor choke - 1 mh - 31 A - 3 phases - 90 W - for variable speed drive

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

em4 local - Robust Specific characteristics Part number

PowerFlex 400 Submittal

Inverter MICROMASTER 410

SX (400 V) System configuration

SX (690 V) System configuration

Electronic timer CT-SDD.22

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

SX (400V) System configuration

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

CP-T range Benefits and advantages

08/07/2015

Electronic timer CT-TGD.22

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

CP-E range Benefits and advantages

Transcription:

Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Nov 24, 2017 Variable speed drive Asynchronous motors Simple machine With heat sink ATV12 Quantity per set Set of 1 EMC filter Built-in fan Network number of phases Without EMC filter With 3 phases [Us] rated supply voltage 200...240 V - 15...10 % Motor power kw Motor power hp Communication port protocol Line current 4 kw 5 hp Modbus Speed range 1...20 Transient overtorque Asynchronous motor control profile IP degree of protection Noise level Complementary 23.8 A 200 V 19.9 A 240 V 150...170 % of nominal motor torque depending on drive rating and type of motor Quadratic voltage/frequency ratio Sensorless flux vector control Voltage/Frequency ratio (V/f) IP20 without blanking plate on upper part 50 db Supply frequency 50/60 Hz +/- 5 % Connector type Physical interface 1 RJ45 Modbus on front face 2-wire RS 485 Modbus 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

Transmission frame Transmission rate Number of addresses Communication service Prospective line Isc Continuous output current Maximum transient current Speed drive output frequency Nominal switching frequency Switching frequency Braking torque Motor slip compensation Output voltage Electrical connection Tightening torque Insulation Supply Analogue input number 1 Analogue input type Discrete input number 4 Discrete input type Discrete input logic Sampling duration Linearity error Analogue output number 1 Analogue output type Discrete output number 2 Discrete output type Minimum switching current Maximum switching current Acceleration and deceleration ramps Braking to standstill Protection type RTU Modbus 4800 bit/s 9600 bit/s 19200 bit/s 38400 bit/s 1...247 Modbus Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/Write multiple registers (23) 4/4 words Read device identification (43) <= 5 ka 16.7 A 4 khz 25 A 60 s 0.5...400 Hz 4 khz 2...16 khz adjustable 4...16 khz with derating factor Up to 70 % of nominal motor torque without braking resistor Adjustable Preset in factory 200...240 V 3 phases Terminal 5.5 mm² AWG 10 L1, L2, L3, U, V, W, PA, PC 1.2 N.m Electrical between power and control Internal supply for reference potentiometer 5 V DC 4.75...5.25 V 10 ma overload and short-circuit protection Internal supply for logic inputs 24 V DC 20.4...28.8 V 100 ma overload and short-circuit protection Configurable voltage AI1 0...10 V 30 kohm Configurable voltage AI1 0...5 V 30 kohm Configurable current AI1 0...20 ma 250 Ohm Programmable LI1...LI4 24 V 18...30 V Negative logic (sink) > 16 V < 10 V 3.5 kohm Positive logic (source) 0...< 5 V > 11 V 20 ms +/- 1 ms logic input 10 ms analogue input +/- 0.3 % of maximum value analogue input Software-configurable voltage AO1 0...10 V 470 Ohm 8 bits Software-configurable current AO1 0...20 ma 800 Ohm 8 bits Logic output LO+, LO- Protected relay output R1A, R1B, R1C 1 C/O 5 ma 24 V DC logic relay 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms logic relay 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms logic relay 3 A 250 V AC resistive cos phi = 1 L/R = 0 ms logic relay 4 A 30 V DC resistive cos phi = 1 L/R = 0 ms logic relay Linear from 0 to 999.9 s S U By DC injection <= 30 s Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases 2

Frequency resolution Time constant Marking Operating position Height Width Depth Product weight Specific application Discrete and process manufacturing Motor starter type 0.1 Hz display unit Converter A/D, 10 bits analog input 20 ms +/- 1 ms for reference change CE Vertical +/- 10 degree 184 mm 140 mm 141.2 mm 2 kg Commercial equipment Commercial equipment : mixer Commercial equipment : other application Textile : ironing Variable speed drive Environment Electromagnetic compatibility Immunity to conducted disturbances level 3 EN/IEC 61000-4-6 Surge immunity test level 3 EN/IEC 61000-4-5 Voltage dips and interruptions immunity test EN/IEC 61000-4-11 Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 Electromagnetic emission Product certifications Vibration resistance Shock resistance Radiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 khz shielded motor cable Conducted emissions EN/IEC 61800-3 CSA C-Tick GOST NOM UL 1 gn EN/IEC 60068-2-6 13...200 Hz 1.5 mm peak to peak EN/IEC 60068-2-6 3...13 Hz drive unmounted on symmetrical DIN rail 15 gn EN/IEC 60068-2-27 11 ms Relative humidity 5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3 Ambient air temperature for storage -25...70 C Ambient air temperature for operation Operating altitude -10...50 C protective cover from the top of the drive removed 50...60 C with current derating 2.2 % per C > 1000...3000 m with current derating 1 % per 100 m <= 1000 m without derating Offer Sustainability Sustainable offer status RoHS (date code: YYWW) REACh Not Green Premium product Compliant - since 0901 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Contractual warranty Warranty period 18 months 3

Dimensions Drawings Dimensions Drive without EMC Conformity Kit Drive with EMC Conformity Kit 4

Mounting and Clearance Mounting Recommendations Clearance for Vertical Mounting Mounting Type A Mounting Type B Remove the protective cover from the top of the drive. Mounting Type C Remove the protective cover from the top of the drive. 5

Connections and Schema Three-Phase Power Supply Wiring Diagram A1 KM1 Q1 Drive Contactor (only if a control circuit is needed) Circuit breaker 6

Connections and Schema Recommended Schemes 2-Wire Control for Logic I/O with Internal Power Supply LI1 : LI : A1 : Forward Reverse Drive 3-Wire Control for Logic I/O with Internal Power Supply LI1 : LI2 : LI : A1 : Stop Forward Reverse Drive Analog Input Configured for Voltage with Internal Power Supply (1) 2.2 kω 10 kω reference potentiometer A1 : Drive Analog Input Configured for Current with Internal Power Supply (2) 0-20 ma 4-20 ma supply A1 : Drive 7

Connected as Positive Logic (Source) with External 24 vdc Supply (1) 24 vdc supply A1 : Drive Connected as Negative Logic (Sink) with External 24 vdc supply (1) 24 vdc supply A1 : Drive 8

Performance Curves Torque Curves 1 : Self-cooled motor: continuous useful torque (1) 2 : Force-cooled motor: continuous useful torque 3 : Transient overtorque for 60 s 4 : Transient overtorque for 2 s 5 : Torque in overspeed at constant power (2) (1) For power ratings 250 W, derating is 20% instead of 50% at very low frequencies. (2) The nominal motor frequency and the maximum output frequency can be adjusted from 0.5 to 400 Hz. The mechanical overspeed capability of the se 9

Motor Starter BOM Our Proposal: Circuit Breaker + Contactor + Drive for Motor Power 4 kw and 200 VAC Motor power (kw) ICU (ka) Breaker Contactor (*) Motor Starter 4 30 LC1D25P7 Non contractual pictures. GV2ME32 (*) You can select the contactor proposed or variants. Please consider examples hereafter or follow the link to the complete offer. Motor power kw Coil voltage VAC - 50/60 Hz 24 48 110 115 220 230 400 Other 4 LC1D25.. B7 E7 F7 FE7 M7 P7 V7 Complete Offer Motor power kw Coil voltage VDC 24 48 110 125 220 230 Other 4 LC1D25.. BD ED - - - - Complete Offer Motor power kw Coil voltage Low Consumption 24 110 Other VDC - U 0.8 1.25 Uc 4 LC1D25.. BL FL Complete Offer 10