OBICON. Perfect Harmony. Short overview. ROBICON Perfect Harmony. System Overview. The Topology. The System. ProToPS. Motors.

Similar documents
Innovations in Drive Technologies. High-availability, medium-voltage, variable speed drives for pumping and compression

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

Meduim Voltage Drives

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Generator Advanced Concepts

Latest Control Technology in Inverters and Servo Systems

Type of loads Active load torque: - Passive load torque :-

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Code No: R Set No. 1

Understanding Input Harmonics and Techniques to Mitigate Them

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

AC Drive Technology. An Overview for the Converting Industry. Siemens Industry, Inc All rights reserved.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

TMdrive -XL Series Family Product Application Guide. solar inverters. power generation

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

PowerFlex Medium Voltage Drives with Direct-to-Drive Technology Eliminating the Isolation Transformer

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

Medium Voltage Drives in Industrial Applications. By: Navid Zargari & Steven Rizzo Rockwell Automation Cambridge, ON

ROTOR FAULTS DETECTION IN SQUIRREL-CAGE INDUCTION MOTORS BY CURRENT SIGNATURE ANALYSIS

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Control of Electric Machine Drive Systems

DC CIRCUITS Part I of III Parts. Part II installation. Part III troubleshooting

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

Large-Capacity Variable-Speed AC Drive

Power IT LV Active Filters PQFA - PQFL - PQFT

Power Factor. Power Factor Correction.

Conventional Paper-II-2013

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

SYNCHRONOUS MACHINES

MV VFD Discussion MIA Detroit 2016

ELECTRONIC CONTROL OF A.C. MOTORS

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

High Frequency/Precision Drives by Design

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

PART 1 OWNER/APPLICANT INFORMATION

VARIABLE FREQUENCY DRIVE

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

Application of Electrical Signature Analysis. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

Placement Paper For Electrical

Phoenix DX Clean Power (18 Pulse) AC Drive

p. 1 p. 6 p. 22 p. 46 p. 58

Magtech Voltage Booster MVB

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Magtech Voltage Booster MVB

Product Application Note. Comparison of Higher Performance AC Drives and AC Servo Controllers. Applicable Product: General AC Drives

Harmonic Distortion and Variable Frequency Drives

CHAPTER 1 INTRODUCTION

Hours / 100 Marks Seat No.

Reliability Starts Here. PowerFlex TM 7000 Family of MV Drives

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

ADJUSTABLE SPEED DRIVES FS1

AF91 Adjustable Frequency Drives Series B

Upgrading from Stepper to Servo

State of North Dakota Engineering data submittal Page 1 For interconnection of distributed generation to Otter Tail Power Company

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Power Quality Solutions

For non-electrical quantities

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

LINEATOR. Advanced Universal Harmonic Filter

Options & Accessories

EE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Protection of Electrical Networks. Christophe Prévé

Part Five. High-Power ac Drives

MECH 1100 Quiz 4 Practice

Electromagnetic and thermal model for Brushless PM motors

Automotive EMC. IEEE EMC Society Melbourne Chapter October 13, 2010 By Mark Steffka IEEE EMCS Distinguished Lecturer

ENGINEERING ACADEMY X V

IRT AT-Small. Technical Manual. quality IN MOTION. quality IN MOTION

Medium Voltage VFD MVC Series. 200kW to 40MW 2.3kV to 18kV

Substation applications

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

Learning Module 20: Adjustable Frequency Drives. 101 Basic Series

GATE: Electronics MCQs (Practice Test 1 of 13)

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Effects of Harmonic Distortion I

VFDs and Harmonics in HVAC Applications

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Options & Accessories

Eyenubo, O. J. & Otuagoma, S. O.

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Time constants ( s ) Resistance. Other data - Class H /6600 V kva. Efficiencies ( % )(3 phase - Classe H V kva)

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

The new Yaskawa Varispeed G7 Inverter


TDE MACNO Spa. AC&DC Drives, Servos and Drive System. AFE converters for Renewable Energies Regenerative (active) power supply (Active Front End)

Univerter-MV. Medium Voltage Variable Speed Drive

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

Induction Machine Test Case for the 34-Bus Test Feeder -Distribution Feeders Steady State and Dynamic Solutions

DEVELOPMENT OF A SILENT BRUSHLESS DC MOTOR DRIVE. S. Camilleri, D. Patterson & H. Pullen

Module 7. Electrical Machine Drives. Version 2 EE IIT, Kharagpur 1

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Industrial Electrician Level 3

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Transcription:

and Drives Control R Interface OBICON Perfect Harmony Short overview 14.03.2007 1

System overview Product features Truly Scaleable Technology 300 kw to 30 MW (Single Channel) Large Number of Framesizes Most Motor oltages Supported Low Harmonic Input High Efficiency and Power Factor Line Disturbance Immune New or Existing Negligible Pulsating Torques High Availability 14.03.2007 2

System overview The Harmony concept: provide an integrated FD system Feature Isolation Transformer Perfect Harmony Included Harmonic Filtering Power Factor Correction Power Converter Motor Filter Inherent Inherent Included Inherent Easy engineering Simple installation Lower installed cost. 14.03.2007 3

System overview Product history Product introduction 1994 Increased output to 6.6 K 1995 (690 cells) Gen II: Options program 1996 UL/CSA 1996 1998 Gen III Harmony CE Mark Fast Bypass Increased max power to 19,000 ka (1250 A 690 cells) 1998 1999 1999 2000 Introduced Harmony H for 13.8 K motors 2003 Largest PWM FD 45/60 MW with AFE 2004 3000 Perfect Harmony units sold 2005 Introduced Gen I smallest air-cooled M FD 2006 14.03.2007 4

Perfect Harmony Topology Typical Power Section Schematic 4160 olt Drive (750 Power Cells) Fiber optics Local Controls FD Control 14.03.2007 5

Perfect Harmony Topology Principle of Operation These cells are in phase at zero degrees electrical These cells are in phase at 240 degrees electrical These cells are in phase at 120 degrees electrical 14.03.2007 6

System performance Isolation transformer Power cells Integrated transformer Features Isolation transformer: included No motor common mode voltage issues Continued operation with one earth fault possible Isolation transformer built into drive cubicle Customer benefits Prevents risk of motor damage by common mode voltages Enhances the retrofit capability Avoids expensive motor modifications or the need for a new motor Increased system availability Easy plug-and-play installation: Three cables in, three cables out Perfect for retrofit projects 14.03.2007 7

System performance Input power quality 1000 HP / 750 KW FD, 1100 ka 5.75% Impedance Source Features Harmonic filter inherent: Clean power sinusoidal converter Near zero harmonics Customer benefits Meets all new requirements of IEEE 519 1992 for both current and voltage distortion Eliminates needs to do harmonic analysis Eliminates costly harmonic filters required for distortion control 14.03.2007 8

System performance Loss of power supply Continued operation when line voltage lost Restored operation with no trip for 5 cycle power interruption Restart Into spinning load with no load or line disturbance as long as motor flux is present 14.03.2007 9

System performance Motor compatibility Features Motor filter inherent: No common mode motor insulation stress No additional FD induced motor heating No dv/dt problems Customer benefits Drive is compatible with both new and existing motors Torque ripple 1% or less on driven load at all operating frequencies Drive can be safely applied to 1.0 service factor motors Drive creates no motor voltage insulation stress Motor does not require reinforced insulation 14.03.2007 10

System performance Motor compatibility Output Waveforms @ 60 HZ and 30 HZ Wave forms remain high quality at lower speeds due to multi-level PWM output. 14.03.2007 11

System performance Output harmonics Output Harmonics - Robicon Perfect Harmony Series @ 30 HZ, Full Load Less Than 2% FD Induced Torque Ripple on Driven Load 14.03.2007 12

Temp Rise (degf) System performance Motor harmonic temperature rise Output Harmonics - Robicon Perfect Harmony motor operating from Generator vs. Perfect Harmony 60 50 40 Recirc Pump Motor 2B Temperature Rise (Based on 3 hour Averages) 30 20 MG Set FD 10 0-10 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 Speed (RPM) 14.03.2007 13

System performance Factory integration Features Factory integration: Fully integrated at Siemens A&D LD A Complete In-factory test -tested as complete systems in our plant Customer benefits Fast and safe commissioning at customer site Comprehensive proof of performance Enhances reliability by weeding out early failures 14.03.2007 14

ProToPS Advanced Cell Bypass Advanced Cell Bypass Results 14.03.2007 16

ProToPS Bypass Contactor and Control Traction DC Contactor Automatic bypass of a failed power cell in 250 ms Completely redundant bypass control: Physically separate from cell Allows bypass down to (1) one cell per phase Allows unequal number of active cells per phase U.S. Patent No. 5,986,909 issued November 16, 1999 Bypass Contactor Cell Bypass Control Logic Redundant control 14.03.2007 17

Control Open Loop Sensorless ector Control Motor-mounted encoder NOT required Duplicates two-quadrant DC operation Provides precision speed/torque control Features fast dynamic response Has low speed/high torque capability Auto Tuning Provides motor information to optimize control Is a two-stage process Stage 1: Stator resistance, leakage inductance Stage 2: Motor no-load current, inertia 14.03.2007 19

Power monitoring Can determine and display information about input waveform and drive output Input display parameters Input voltage Input voltage harmonics (one at a time) Input current Input current harmonics (one at a time) Input PF Input power (kw) Input reactive power (kar) Input kw-hr Input phase sequence Loss of phase Low voltage Transformer overload Output power (kw) kw-hr Output current RMS Output voltage RMS FD efficiency Motor torque Motor speed (RPM) Motor slip (%) Drive output frequency (Hz) Magnetizing current Torque current Motor flux 14.03.2007 20

Control Drive Tool Menu structure window Graphics window Drive status window Provides Windows-based graphical user interface Provides full drive functionality Features same structure as keypad interface Has multiple language support 14.03.2007 21

The perfect products for a broad spectrum of motors H-compact IEC 200-3000 kw 2-11 k 2-12 pole H-compact PLUS IEC, ANEMA 1000-7000 kw 1340 9390 HP 3.3-13.2 k 2-12 pole Series 1R.5/S.5 IEC 7000-10000 kw 3.3-13.2 k 4-24 pole H-modyn IEC, ANEMA 7000-50000 kw 9390 67000HP 6-13.2 k 2-12 pole Special motors 2000-65000 kw 690-13.2 k Squirrel cage Cast iron housing with cooling ribs IP55 ANEMA 150-2500 HP 0.2 11 k 2-16 pole Squirrel cage Cast iron housing with cooling ribs IP55/TEFC Squirrel cage Cast iron-/ Steel housing, cooler assembly IP23, IP55, WP II ANEMA 200-10000 HP 0.2-13.8 k 2-16 pole Squirrel cage Cast iron housing cooler assembly Squirrel cage slip ring rotor Synchronous Cast iron-/ Steel housing, cooler assembly IP55, WP II Squirrel cage Synchronous Base frame, Water cooling IP55, WP II Retrofit Existing motors with standard windings Squirrel cage synchronous Example: Highspeed compressor drive ODP, WP I, WP II, TEAAC/TEWAC 14.03.2007 22

The perfect products for all applications Cement Paper Water & Waste water SINAMICS GM150 Oil & Gas Compressors Pumps Mining Fans Chemical Shipbuilding Power 14.03.2007 23