Bulletin 800MR/800MB Push Buttons

Similar documents
Bulletin 800MR/800MB Push Buttons

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Allen-Bradley Spares

Bulletin 800FC 22.5 mm Configured Pendant Stations Product Overview. Position 1... Position 9

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Control Stations ø 22

Complete units: Selector switches ø 22mm

Complete units: Push-buttons ø 22mm

Complete units: Mushroom heads ø 22mm

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Operator Heads: ø 22mm

AC-Operated Latch Units PKLL11. Reset Input. DC-Operated Latch Units DC-PKLL10

1.3. Pushbuttons and Indicating Lights.

Switches & Pilot Devices

Signaling Lights. SLC40 Series Panel Mounted Annunciators. SLC 40 Series Annunciators

Operator Heads: ø 22mm

Separate units: Blocks

Bulletin 700-RTC Solid-State Timing Relay

General data. 13/20 Siemens IC Overview Front plate mounting

Open Type Without Enclosure

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

A W - A 2A R - 24D - 1

Model Number Structure

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

TWTD Series: Heavy duty switches built to last

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

General-purpose Relay

OMRON MK-I / -S RELAY

Round Indicator Lights Mounting Hole Page

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Dispozitive de acţionare şi indicatori

General-purpose Relay

General-Purpose Photoelectric Sensor

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Pendant control stations 6

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

The Superior Choice for Material Handling Equipment 22.5 mm 800FC

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

Details on the New G2RS

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Major 5001 Wire Stripper

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Open Type Without Enclosure

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Model Number Structure

Operation Manual February Opticom Infrared System

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

RU Series Universal Relays

Installation Instructions PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors

Photoelectric Sensor

Electromagnetic flowmeters and switches DWM 1000/2000

Solid-state Twin Timer

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Spring Return DuraDrive Proportional Actuator

General Specifications

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Solid-state Timer H3DS

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

6mm Interface Relays RV8 Series

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

AS-Interface Slaves. SIRIUS Pushbuttons and Indicator Lights. CustomAS-Interface enclosures 10/101

Integra 1560 and 1580 Digital Transducer Systems

Universal Voltage Cabled Photoelectric E3JK

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

Actuators Series 8602/3

Accessories. Accessories

LED Neon Light Round

Specifications. Safety Ratings. Standards. Safety Classification

Inductive Proximity Sensor

General-Purpose Photoelectric Sensors with Self-Contained Amplifier

7PG21 Solkor R/Rf Pilot Wire Current Differential Protection Energy Management

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

CALRAD 25 series - potentiometers

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

SMT TR series. Surface mount tiny washable rocker switches. Distinctive features and specifications.

ø30 ARN/ARNS Series Mono-lever Switches Switches

VA-9070 Series Electric Rotary Actuators for Two-Position and Modulating Service

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

Installation Instructions

Transcription:

ulletin 800MR/800M Push uttons ulletin 800MR uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Round operators ul. 800MR ulletin 800M uild a Catalog Number 22.5 mm mounting hole Type 13 oiltight Square backlit operators UL Listed File: E14840, E10314 Guide: NKCR, NIV CSA Certified: LR1234, LR11924 IEC Compliance, IEC 529 ul. 800M ul. 800MR - Momentary Contact Push uttons uild a Catalog Number Momentary Contact Push utton Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Flush Head Unit 800MR-A1 Extended Head Unit 800MR-2A Mushroom Head Unit 800MR-D2

Contact Type utton Color Flush Head Extended Head Mushroom Head 1 N.. Green 800MR-A1D1 800MR-1D1 800MR-D1D1 lack 800MR-A2D1 800MR-2D1 800MR-D2D1 Red 800MR-A6D1 800MR-6D1 800MR-D6D1 1 Green 800MR-A1D2 800MR-1D2 800MR-D1D2 lack 800MR-A2D2 800MR-2D2 800MR-D2D2 Red 800MR-A6D2 800MR-6D2 800MR-D6D2 1 N.. - 1 Green 800MR-A1A 800MR-1A 800MR-D1A lack 800MR-A2A 800MR-2A 800MR-D2A Red 800MR-A6A 800MR-6A 800MR-D6A 2 N.. - 2 Green 800MR-A1 800MR-1 800MR-D1 lack 800MR-A2 800MR-2 800MR-D2 Red 800MR-A6 800MR-6 800MR-D6 800MR A 1 A a b c d a b c d perator Type utton Color Standard Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description Code Description A Flush head 1 Green lank No contacts lank Stab terminals Extended head 2 lack A 1 N.. - 1 K Large screw D Mushroom head 3 range A2 2 N.. 4 Grey A3 1 N..E.M. - 1 L.. 5 White A4 2 6 Red A7 1 L.. - 1 7 lue 2 N.. - 2 9 Yellow D1 1 N.. D2 1 Guards must be ordered separately. Logic Reed and small screw blocks can be ordered separately. Momentary Contact Push utton Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Flush Head Unit 800MR-QA24GA Extended Head Unit 800MR-P16RA Mushroom Head Unit 800MR-QM24RA

Contact Type Power Module Type Supply Voltage Lamp Type Lens Color Flush Head Extended Head Mushroom Head 1 N.. - 1 Full Voltage 24V AC/DC Incandescent Red 800MR-QA24RA 800MR-Q24RA 800MR-QM24RA Green 800MR-QA24GA 800MR-Q24GA 800MR-QM24GA Amber 800MR-QA24AA 800MR-Q24AA 800MR-QM24AA Transformer 120V AC Incandescent Red 800MR-PA16RA 800MR-P16RA 800MR-PM16RA Green 800MR-PA16GA 800MR-P16GA 800MR-PM16GA Amber 800MR-PA16AA 800MR-P16AA 800MR-PM16AA Full Voltage 12V AC/DC LED Red 800MR-QAL12RA 800MR-QL12RA 800MR-QML12RA Green 800MR-QAL12GA 800MR-QL12GA 800MR-QML12GA Amber 800MR-QAL12AA 800MR-QL12AA 800MR-QML12AA 24V AC/DC LED Red 800MR-QAL24RA 800MR-QL24RA 800MR-QML24RA Green 800MR-QAL24GA 800MR-QL24GA 800MR-QML24GA Amber 800MR-QAL24AA 800MR-QL24AA 800MR-QML24AA Transformer 120V AC LED Red 800MR-PAL16RA 800MR-PL16RA 800MR-PML16RA Green 800MR-PAL16GA 800MR-PL16GA 800MR-PML16GA Amber 800MR-PAL16AA 800MR-PL16AA 800MR-PML16AA 800MR PA L 24 R a b c d e f a b c d e f perator Illumination ptions Input Voltage Lens Color Standard Contact Cartridges Transformer Full Voltage Contact lock Termination Type Code Description Code Description Code Description Code Color Code Description Code Description PA Flush lank Standard illumination as determined by power module type 12 12V AC/DC A Amber lank No contacts lank Stab terminals P Extended L LED 24 24V AC/DC lue A 1 N.. - 1 K Large screw PM Mushroom 10 120V AC C Clear A2 2 N.. Full Voltage Transformer G Green A3 1 N..E.M. - 1 L.. Code Description Code Description R Red A4 2 QA Flush 16 120V AC 50/60 Hz W White A7 1 L.. - 1 Q Extended 26 240V AC 50/60 Hz No lens with contact blocks 2 N.. 2 QM Mushroom lank No lens without contact blocks D1 D2 1 N.. 1 LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED Illumination option. nly available with full voltage power module option and standard stab terminations. Guards must be ordered separately. Logic Reed and small screw blocks must be ordered separately. ul. 800MR Push Pull uild a Catalog Number 2-Position Push-Pull and Push-Pull/Twist Release Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately.

2-Position Push-Pull 800MR-F6A 2-Position Push-Pull/Twist 800MR-FT6A4 Contact Type perator Position utton Color Push-Pull Push-Pull/ Twist Release Maintained Maintained ut In No Contacts Red 800MR-F6 800MR-FT6 1 N.. Red 800MR-F6D1 800MR-FT6D1 1 Red 800MR-F6D2 800MR-FT6D2 1 N.. - 1 Red 800MR-F6A 800MR-FT6A 1-1 Red 800MR-F6A4 800MR-FT6A4 Note: = Closed/ = pen 3-Position Push-Pull Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. 3-Position Push-Pull 800MR-FN6A7 Contact Type perator Position utton Color Push-Pull Momentary Maintained Momentary ut Center In No Contacts Red 800MR-FN6 1 N.. - 1 Red 800MR-FN6A 1-1 L.. Red 800MR-FN6A7 1-1 L.. 1-1 L.. Red 800MR-FN66 Note: = Closed/ = pen 800MR F T 6 A a b c d e f (2-Position)

800MR F N 6 A a b 1 c d e f (3-Position) a b b 1 c perator Type perator Function perator Function perator 2-Position 3 Position Code Description Code Description Code perator Position Code Color F Push-pull unit lank Maintained push pull lank Non-illuminated T Twist-release ut Center In N Momentary Maintained Momentary d e f utton Color Contact Cartridges Contact lock Termination Type Code Description Code Description Code Color lank No contacts lank Stab terminals 1 Green A 1 N.. - 1 K Large screw 2 lack A2 2 N.. 3 range A4 2 4 Grey A7 1 L.. - 1 5 White 2 N.. - 2 6 Red D1 1 N.. 7 lue D2 1 9 Yellow Note: See Table 1 for Target description. lank No cap Table 1. Target Selection Code 2-Position Contact Description 3-Position Code ut In ut Center In lank No contacts lank D1 N.. D2 A N.. - A A2 N.. - N.. A2 A4 - A4 - L.. A7 N.. - N.. - Note: = Closed/ = pen Not available in twist release. Logic Reed and small screw blocks must be ordered separately. 2-Position Push-Pull and Push-Pull/Twist Release Units, Illuminated

Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Illuminated 2-Position Push-Pull 800MR-FQ24RA Illuminated 2-Position Push-Pull/Twist 800MR-FTP16RA Lamp Type Power Module Type Supply Voltage Lens Color perator Position Push-Pull Push-Pull/ Twist Release Maintained Maintained Contacts ut In Incandescent Full Voltage 12V AC/DC Red N.. - 800MR-FQ12RA 800MR-FTQ12RA 24V AC/DC Red 800MR-FQ24RA 800MR-FTQ24RA Transformer 120V AC Red N.. - 800MR-FP16RA 800MR-FTP16RA 240V AC Red 800MR-FP26RA 800MR-FTP26RA LED Full Voltage 12V AC/DC Red N.. - 800MR-FQL12RA 800MR-FTQL12RA 24V AC/DC Red 800MR-FQL24RA 800MR-FTQL24RA Transformer 120V AC Red N.. - 800MR-FPL16RA 800MR-FTPL16RA 240V AC Red 800MR-FPL26RA 800MR-FTPL26RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. 3-Position Push-Pull Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Illuminated 3-Position Push-Pull 800MR-FNQ24RA7

Lamp Type Power Module Type Supply Voltage Lens Color perator Position Push-Pull Momentary Maintained Momentary Contacts ut Center In Incandescent Full Voltage 12V AC/DC Red L.. - 800MR-FNQ12RA7 24V AC/DC Red 800MR-FNQ24RA7 Transformer 120V AC Red L.. - 800MR-FNP16RA7 240V AC Red 800MR-FNP26RA7 LED Full Voltage 12V AC/DC Red L.. - 800MR-FNQL12RA7 24V AC/DC Red 800MR-FNQL24RA7 Transformer 120V AC Red L.. - 800MR-FNPL16RA7 240V AC Red 800MR-FNPL26RA7 Note: = Closed/ = pen Transformers operate at 50/60 Hz. 800MR F T P 16 R A a b c d e f g h (2-Position) 800MR F N P 16 R A a b 1 c d e f g h (3-Position) a b b 1 c d perator Type perator Function perator Function perator Type Illumination ptions 2-Position 3-Position Code Description Code Description Code perator Position Code Description Code Description F Push-pull unit lank Maintained P Transformer lank Incandescent lamp T Twist-release ut Ctr. In Q Full voltage L LED N Mom Main Mom Mom-Momentary Main-Maintained e f g h Voltage utton Color Contact Cartridges Contact lock Termination Type Full Voltage Code Description Code Color Code Description Code Description 12 12V AC/DC A Amber lank No contacts lank Stab terminals 24 24V AC/DC lue A 1 N.. - 1 K Large screw 10 120V AC C Clear A2 2 N.. Transformer G Green A4 2 Code Description R Red A7 1.L.. - 1 16 120V AC 50/60 Hz W White 2 N.. 2 26 240V AC 50/60 Hz No cap D1 1 N.. D2 1 Note: See Table 1 for Target description.

Table 2. Target Selection Code 2-Position Contact Description 3-Position Code ut In ut Center In lank No contacts lank D1 N.. D2 A N.. - A A2 N.. - N.. A2 A4 - A4 - L.. A7 N.. - N.. - Note: = Closed/ = pen Not available in twist release. LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED Illumination option. nly available with full voltage power module option and standard stab terminations. Logic Reed and small screw blocks must be ordered separately. ul. 800MR - Selector Switches uild a Catalog Number 2-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-HH2LA Knob Lever perator 800MR-HK2LA Contact Type Knob Color Contact perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever lack A M M 800MR-HH2LA 800MR-HK2LA S M 800MR-HH4LA 800MR-HK4LA 1 N.. - 1 M S 800MR-HH5LA 800MR-HK5LA lack A M M 800MR-HH2 800MR-HK2 S M 800MR-HH4 800MR-HK4 Right A 2 N.. - 2 M S 800MR-HH5 800MR-HK5 Note: = Closed/ = pen 2-Position Cylinder Lock perator 800MR-H31

Contact Type Contact perator Position perator Type M = Maintained S = Spring Return Cylinder Lock Lock in Lock in Right Lock in oth A M M 800MR-H31LA 800MR-H32LA 800MR-H33LA S M 800MR-H42LA 1 N.. - 1 M S 800MR-H48LA A M M 800MR-H31 800MR-H32 800MR-H33 S M 800MR-H42 Right A 2 N.. - 2 M S 800MR-H48 Note: = Closed/ = pen Target tables are reversed from those shown. Key removable in locked position only. 800MR H H 2 L A a b c d e e 1 f (Selector Switch) 800MR H 31 L A a b c 1 c 2 d e e 1 f (Cylinder Lock) a b c c 1 c 2 perator Positions perator Color and Type perator Function perator Function/Locking Position Key Codes Standard Knob Standard Knob Maintained Code Key No. Master Key Code Description Code Description Code Description Code Description lank T100 (standard) 1T H 2-position selector switch No knob 2 Maintained 31 Lock in left 02 T101 1T H 2-position cylinder lock H lack 4 Spring return from left Knob Lever 5 Spring return from right 32 Lock in right 03 T102 1T 33 Lock in both 04 T106 1T Code Description Spring Return From 05 T107 1T No knob lever Code Description 07 T109 2T K lack 42 Lock in right 08 T134 2T Cylinder Lock Spring Return From Right 09 T135 2T Code Description Code Description 10 T136 2T lank Key 48 Lock in left 14 T147 2T

d e e 1 f Cam Type Contact Cartridge Position Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description Code Description cam lank oth left and right lank No contacts lank Stab terminals L A 1 N.. - 1 K Large screw A2 2 N.. A4 2 2 N.. - 2 D1 1 N.. D2 1 P1 3 N.. P2 3 P3 2 N.. - 1 P4 2-1 N.. P5 4 N.. P6 4 P7 3 N.. - 1 P8 1 N.. - 3 Note:See Table 1 for Target arrangements Table 1. Selector Switch Cam Targets Cam Description (2-Position) Target perator Function Maintained and Spring Returned From Right Spring Returned From N.. N.. Note: = Closed/ = pen Key removable in locked position only. If no optional key code is specified, the standard key (T100) will be supplied. Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and lever knobs must be ordered separately. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table e) must be L. Contact cartridge position code (Table e) must be --. 3-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-JH2 Knob Lever perator 800MR-JK2

Contact Type Color Contact perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever lack A M M M 800MR-JH2LA 800MR-JH2LA S M M 800MR-JH4LA 800MR-JK4LA M M S 800MR-JH5LA 800MR-JK5LA 1 N.. - 1 S M S 800MR-JH9LA 800MR-JK9LA lack A M M M 800MR-JH2 800MR-JK2 S M M 800MR-JH4 800MR-JK4 Right A M M S 800MR-JH5 800MR-JK5 2 N.. - 2 S M S 800MR-JH9 800MR-JK9 Note: = Closed/ = pen Cylinder Lock perator 800MR-J44 Contact Type Contact perator Position perator Type M = Maintained S = Spring Return Cylinder Lock Lock in All Lock in Center Lock in Right A M M M 800MR-J44LA 800MR-J42LA 800MR-J43LA S M M 800MR-J50LA 800MR-J52LA M M S 800MR-J38LA 1 N.. - 1 S M S 800MR-J631LA A M M M 800MR-J44 800MR-J42 800MR-J43 S M M 800MR-J50 800MR-J52 Right A M M S 800MR-J38 2 N.. - 2 S M S 800MR-J631 Note: = Closed/ = pen Key removable in locked position only. 800MR J H 2 L A a b c d e e 1 f (Selector Switch) 800MR J 41 L A a b c 1 c 2 d e e 1 f (Cylinder Lock)

a b c c 1 perator Positions perator Color and Type perator Function perator Function/Locking Position Standard Knob Description Knob Lever Maintained Code Description Code Code Code Description Code Description J 3-position selector switch No knob 2 Maintained 41 Lock in left J 3-position cylinder lock H lack K 4 Spring return from left 42 Lock in center lank Key lank 5 Spring return from right 43 Lock in right 9 Spring return from both 44 Lock in all positions 45 Lock in left and center 46 Lock in right and left 47 Lock in right and center Spring Return From Code Description 50 Lock in center 52 Lock in right 51 Lock in right and center Spring Return From Right Code Description 69 Lock in left 38 Lock in center 73 Lock in left and center Spring Return From and Right Code Description 631 Lock in center c 2 d e e 1 f Key Codes Cam Type Contact Cartridge Position Contact Cartridges Contact lock Termination Type 1T Master Series Standard Description Code Key No. Code Description Code Description Code side Right side Code Description lank T100 (standard) cam lank oth left and right lank No contacts lank Stab terminals 02 T101 K K cam L A 1 N..-1 K Large screw 03 T102 P P cam R Right A3 1 N..E.M.-1 L.. 04 T106 U U cam 1 N..-1 05 T107 P1 2 N.. 1 N.. 2T Master Series P2 2 1 Code Key No. P3 2 N.. 1 07 T109 P4 2 1 N.. 08 T134 P5 2 N.. 2 N.. 09 T135 P6 2 2 10 T136 P7 2 N.. 1 N.. - 1 14 T147 P8 2 1 N.. - 1 P9 1 N.. 1 T1 1 N.. - 1 1 Note:See Table 1 for cam and contact block selection. Key removable in locked position only. If no optional key code is specified, the standard key (T100) will be supplied. Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and lever knobs must be ordered separately. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table e) must be L or R. Contact cartridge position code (Table e) must be --. Table 1. Selector Switch Cam Targets

Note: = Closed/ = pen Cam Description Target K P U Right Right Right Right N.. N.. N.. N.. N.. N.. N.. N.. N..E.M. N..E.M. L.. N..E.M. L.. L.. L.. L.. L.. 4-Position Selector Switch Units, Non-Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-NH2Q Knob Lever perator 800MR-NK2Q Contact Type Color Contact perator Position perator Type Standard Knob Knob Lever lack A Maintained in All Positions 800MR-NH2Q 800MR-NK2Q 2 N.. - 2 Right A Note: = Closed/ = pen Cylinder Lock perator 800MR-N31Q Contact Type Contact perator Position perator Type Cylinder Lock Lock In All Lock In Position 1 Lock In Position 2 A Maintained in All Positions 800MR-N61Q 800MR-N31Q 800MR-N32Q 2 N.. - 2 Right A Note: = Closed/ = pen Key removable in locked position only.

800MR N H 2 Q a b c d e f (Selector Switch) 800MR N 31 Q a b c 1 c 2 d e f (Cylinder Lock) a b c c 1 perator Positions perator Color and Type perator Function perator Function/Locking Position Standard Knob Description Knob Lever Standard Key Code Description Code Code Code Description Code Description N 4-position selector No knob 2 Maintained 31 Lock in position 1 N 4-position cylinder lock H lack K 32 Lock in position 2 lank Key lank 33 Lock in position 3 34 Lock in position 4 41 Lock in position 1-2 42 Lock in position 1-3 43 Lock in position 1-4 44 Lock in position 2-3 45 Lock in position 2-4 46 Lock in position 3-4 51 Lock in position 1-2-3 52 Lock in position 1-2-4 53 Lock in position 1-3-4 54 Lock in position 2-3-4 61 Lock in all positions c 2 d e f Key Codes Cam Type and Target Table Contact Cartridges Contact lock Termination Type Code Key No. Master Key Q Standard lock/stab Terminations Code Description lank T100 (standard) 1T Target Contact Type (Rear View) Code Description lank Stab terminals 02 T101 1T Right lank No contacts K Large screw 03 T102 1T 1 N.. 2 N.. - 2 04 T106 1T 1 05 T107 1T 1 N.. 07 T109 2T 1 08 T134 2T Note: = Closed/ = pen 09 T135 2T 10 T136 2T 14 T147 2T Red, green, blue, yellow, orange, grey, and white non illuminated selector switch knobs and knob levers must be ordered separately. Key removable in locked position only. perators are maintained in all positions. If no optional key code is specified, the standard key (T100) will be supplied. Logic Reed and small screw contact blocks must be ordered separately. 2-Position Knob/Lever Type Selector Switch Units, Illuminated

Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24HA2RA Knob Lever perator 800MR-24HL2RA Contact Type Type Volts Lamp Knob Color perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red Transformer 120V AC Red Full Voltage 24V AC/DC LED Red Transformer 120V AC Red M M 800MR-24HA2RA 800MR-24HL2RA S M 800MR-24HA4RA 800MR-24HL4RA M S 800MR-24HA5RA 800MR-24HL5RA M M 800MR-16HA2RA 800MR-16HL2RA S M 800MR-16HA4RA 800MR-16HL4RA M S 800MR-16HA5RA 800MR-16HL5RA M M 800MR-24HAL2RA 800MR-24HLL2RA S M 800MR-24HAL5RA 800MR-24HLL5RA M M 800MR-16HAL2RA 800MR-16HLL2RA S M 800MR-16HAL4RA 800MR-16HLL4RA 1 N.. - 1 M S 800MR-16HAL5RA 800MR-16HLL5RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. Target tables are reversed from those shown. 3-Position Knob/Lever Type Selector Switch Units, Illuminated Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24JA2RA Knob Lever perator 800MR-24JL2RA

Contact Type Type Volts Lamp Knob Color perator Position perator Type M = Maintained S = Spring Return Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red M M M 800MR-24JA2RA 800MR-24JL2RA S M M 800MR-24JA4RA 800MR-24JL4RA S M S 800MR-24JA9RA 800MR-24JL9RA Transformer 120V AC Red M M M 800MR-16JA2RA 800MR-16JL2RA S M M 800MR-16JA4RA 800MR-16JL4RA S M S 800MR-16JA9RA 800MR-16JL9RA Full Voltage 24V AC/DC LED Red M M M 800MR-24JAL2RA 800MR-24JLL2RA S M M 800MR-24JAL4RA 800MR-24JLL4RA S M S 800MR-24JAL9RA 800MR-24JLL9RA Transformer 120V AC Red M M M 800MR-16JAL2RA 800MR-16JLL2RA S M M 800MR-16JAL4RA 800MR-16JLL4RA 1 N.. - 1 S M S 800MR-16JAL9RA 800MR-16JLL9RA Note: = Closed/ = pen Transformers operate at 50/60 Hz. 800MR 24 H A L 2 R A a b c d e f g 1 g 2 h (2-Position) 800MR 24 J A L 2 R A a b c d e f 1 g 1 g 2 h (3-Position) a b c Input Voltage perator Positions perator Color and Type Full Voltage Standard Knob Description Knob Lever Code Description Code Description Code Code 12 12V AC/DC H 2-position No knob 24 24V AC/DC J 3-position A Red L 10 120V AC Green M Transformer D Amber P Code Description Y Clear Z 16 120V AC 50/60 Hz 26 240V AC 50/60 Hz d e f f 1 Illumination ptions perator Function Cam Type (2-Position) Cam Type (3-Position) Code Description Code Description Code Description Code Description lank Incandescent 2 Maintained cam cam L LED 4 Spring return from left Note:For Target arrangements see Table 1. K K cam 5 Spring return from right P P cam 9 Spring return from both U U cam Note:For Target arrangements see Table 2.

g 1 g 2 h Contact Cartridge Position Contact Cartridges Contact lock Termination Type Code Description Description lank oth right and left Code side Right side Code Description R Right lank No contacts lank Stab terminals A 1 N..-1 K Large screw A2 2 N.. A3 1 N..E.M.- 1 L.. A4 2 1 N..-1 1 N..-1 D1 1 N.. D2 1 P1 2 N.. 1 N.. P2 2 1 P3 2 N.. 1 P4 2 1 N.. P5 2 N.. 2 N.. P6 2 2 P7 2 N.. 1 N..-1 P8 2 1 N..-1 P9 1 N.. 1 N.C T1 1 N..-1 1 Note: See Table 1 for 2-position contact block selection. See Table 2 for 3-position contact block selection. nly available with LED Illumination option. LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED. nly available with full voltage power module and standard stab terminations. Logic Reed and small screw contact blocks must be ordered separately. Contact cartridge position code (Table g1) must be R. Contact cartridge position code (Table g1) must be --. nly available for 2 position selector switches. Table 1. Selector Switch Cam Targets Cam Description (2-Position) Target perator Function Maintained and Spring Return From Right Spring Return From N.. N.. Note: = Closed/ = pen Table 2. Selector Switch Cam Targets Cam Description (3-Position) Target K P U Right Right Right Right N.. N.. N.. N.. N.. N.. N.. N.. N..E.M. N..E.M. L.. N..E.M. L.. L.. L.. L.. L.. Note: = Closed/ = pen 4-Position Knob/Lever Type Selector Switch Units, Illuminated Contact Terminations

perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations sold separately. Standard Knob perator 800MR-24NA2Q Knob Lever perator 800MR-24NL2Q Contact Type Type Volts Lamp Color perator Position perator Type Standard Knob Knob Lever Full Voltage 24V AC/DC Incandescent Red Maintained in All Positions 800MR-24NA2Q 800MR-24NL2Q 24V AC/DC LED Red 800MR-24NAL2Q 800MR-24NLL2Q 2 N.. - 2 120V AC LED Red 800MR-10NAL2Q 800MR-10NLL2Q Note: = Closed/ = pen 800MR 24 N A L 2 Q a b c d e f g h (4-Position) a b c d Input Voltage perator Positions perator Color and Type Illumination ptions Full Voltage Standard Knob Description Knob Lever Code Description Code Description Code Code Code Description 12 12V AC/DC N 4 position No knob lank Incandescent 24 24V AC/DC A Red L L LED 10 120V AC Green M D Amber P Y Clear Z e f g h perator Function Cam Type and Target Table Contact Cartridges Contact lock Termination Type Q Code Standard knob function Target Contact Type (Rear View) Standard lock Code Description Code Description 2 Maintained Right 2 N.. - 2 lank Stab terminals 1 N.. 1 1 N.. 1 Note: = Closed/ = pen Note: = Closed/ = pen

nly available with LED Illumination option. perator is maintained in all positions. LEDs only available in red, green, amber and white. Knob color must match LED color, except clear knob supplied with white LED. Logic Reed contact blocks must be ordered separately. ul. 800MR - Potentiometers, Pilot Lights, and Wobble Sticks uild a Catalog Number Potentiometer perator nly This operator is suitable for mounting potentiometers or other small single turn rotary operated devices having 3/8 in. diameter bushings (1/4 3/8 in. long) and 1/4 in. diameter shaft (3/4 1 1/2 in. long), plus providing 600V electrical clearances to panel. Includes operator, instruction sheet, and graduated marking ring. This operator does not have a resistive potentiometer element. Potentiometer Unit 800MR-N37 Type Potentiometer perator nly (without Resistive Element) 800MR-N37 Pilot Light Units Contact Terminations perators come standard with stab terminations. To order large screw contact terminations for pilot lights add letter K to the end of the cat. no. For push-to-test pilot lights add the letter K. Pilot Light 800MR-Q24R Push-to-Test Pilot Light 800MR-QT24R

Lamp Type Volts Color Pilot Light Push-to-Test Dual Input Incandescent Full Voltage 12V AC/DC Red 800MR-Q12R 800MR-QT12R Green 800MR-Q12G 800MR-QT12G Amber 800MR-Q12A 800MR-QT12A 24V AC/DC Red 800MR-Q24R 800MR-QT24R Green 800MR-Q24G 800MR-QT24G Amber 800MR-Q24A 800MR-QT24A Transformer 120V AC 50/60 Hz Red 800MR-P16R 800MR-PT16R 800MR-PDT16R Green 800MR-P16G 800MR-PT16G 800MR-PDT16G Amber 800MR-P16A 800MR-PT16A 800MR-PDT16A LED Full Voltage 24V AC/DC Red 800MR-QL24R 800MR-QTL24R Green 800MR-QL24G 800MR-QTL24G Amber 800MR-QL24A 800MR-QTL24A 120V AC Red 800MR-QL10R 800MR-QTL10R Green 800MR-QL10G 800MR-QTL10G Amber 800MR-QL10A 800MR-QTL10A Transformer 120V AC 50/60 Hz Red 800MR-PL16R 800MR-PTL16R Green 800MR-PL16G 800MR-PTL16G Amber 800MR-PL16A 800MR-PTL16A Dual input transformer is transformer relay type. Comes standard with screw terminations. 800MR P L 24 R a b c d e a b c perator Illumination ptions Input Voltage Transformer Full Voltage Code Description Code Description Code Description P Pilot light lank Incandescent 12 12V AC/DC PDT Pilot light dual input transformer L LED 24 24V AC/DC PT Pilot light push to test 10 120V AC Full Voltage Transformer Code Description Code Description Q Pilot light 16 120V AC 50/60 Hz QT Pilot light push to test 26 240V AC 50/60 Hz d e Lens Color Contact lock Termination Type Pilot Lights Code Color Code Description lank No lens lank Stab terminals A Amber K Large screw lue Note:If large screw terminations are desired with a dual input transformer, ( 800MR PDT ), configurator space e must be left blank. C G R W Clear Green Red White

LEDs available in red, green, amber, blue, and white. LED color must match lens color, except clear lens supplied with white LED and white lens supplied with amber LED. nly available with LED illumination option. Small screw contact blocks must be ordered separately. nly available with Push to test units. Wobble Stick Units Designed for ease of operation. Wobble stick units have spring return action and may be operated from any angle. It is particularly useful with pendant stations. Contact Terminations perators come standard with stab terminations. For large screw contact terminations, add letter K to the end of the cat. no. Standard contact blocks with small screw terminations and Logic Reed contact blocks with stab terminations are sold separately. Wobble Stick Unit 800MR-M1 Contact Type Contact Type 1 N.. - 1 800MR-M1A 2 N.. - 2 800MR-M1 800MR M1 A a b c a b c perator Type Contact Cartridges Contact lock Termination Type Code Description Code Description Code Description M1 Wobble stick lank No contacts lank Stab terminals A 1 N.. - 1 K Large screw 2 N.. - 2 Logic Reed and small screw contact blocks must be ordered separately. Specifications

Electrical Ratings Contact Ratings Dielectric Strength Electrical Design Life Cycles Refer to the Contact Ratings tables below. 1600V for one minute 1300V for one minute (Logic Reed) 750 000 at maximum rated load 200 000 at maximum rated load (Logic Reed) Mechanical Ratings Vibration Shock Degree of Protection 10 2000 Hz 1.52 mm displacement (peak to peak) Max./10 G Max. (except Logic Reed) 1/2 cycle sine wave for 11 milliseconds ³ 25 G (contact fragility) and no damage at 100 G Type 13; IEC I44 IP65 iltight Mechanical Design Life Cycles Push uttons Potentiometers All other devices Contact peration 1 000 000 minimum 100 000 minimum 200 000 minimum Contact blocks with ifurcated spanner:slow make and break, simple break. Logic Reed Contact locks:snap-action Typical perating Forces perators without contact blocks 2.45 lb (10.8 N) Push-Pull Units 8 lb (35.3 N) push to in position 4 lb (17.7 N) maximum pull to out position Contact locks Standard 1.5 lb (6.7 N) Logic Reed 0.616 lb (2.6 N) Environment Temperature Range perating 32 131 F (0 55 C) Storage 40 +185 F ( 40 +85 C) Note:perating temperatures at +32 F (0 C) are based on the absence of freezing moisture and liquids. Humidity Panel Thickness Requirements 50% at 104 F (40 C) 1/16 1/4 in. (1.6 6.4 mm) Performance Data See Performance Data. Standard Contact Ratings (IEC 337-1) (NEMA ICS 2-125) Maximum continuous current I th 10 A. ulletin 800M units have control circuit ratings with 800M contact blocks as follows: Maximum perational Volts Ue Utilization Category Rated perational Currents IEC NEMA Volts Ue Make reak AC 300 AC-II A300 120 300 7200 VA 720 VA 72 120 60 VA 720 VA 24 72 60 A 10 A For applications below 24V and 24 ma, Logic Reed contacts are recommended. Logic Reed Contact Ratings Maximum: 150V AC, 0.15 A, 8 VA and 30V DC, 0.06 A, 1.8 VA. Should only be used with resistive loads. Wire Capacity Stab Termination Contact locks Accepts two 0.110 x 0.032 in. push-on connectors or one 0.250 x 0.032 in. push-on connector. Small Screw Contact locks Accepts one #14 or two #16 AWG solid or stranded wires. Large Screw Termination Contact locks Accepts two #12 AWG solid or stranded wires. Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. ul. 800MR Extension in Front of Panel

Round Push utton Flush, Extended and Illuminated Extended Round Push utton Illuminated Flush Round Push utton Mushroom Round Selector Switch and Potentiometer and Standard Knob Panel Wobble Stick Unit Round Selector Switch and Potentiometer and Wing Lever Round Cylinder Lock Selector Switch Round Push-Pull Twist or Pull Release Units ul. 800M Front View of Square Units CAUTIN: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1-1/2 in. (38.1 mm) minimum centers in one direction. Unit without Insert and acklit Unit Square acklit with Guarded ezel Square acklit with Unguarded ezel Dual perator Unit ul. 800M Extension in Front of Panel Square Push utton Flush and Extended Square Push utton Large Extended Square Push utton Dual perator Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Extension ehind Panel Units with Quick Connect Terminal Contact locks (Typical View) Units Having Screw Terminals with Pressure Plate Contact locks (Typical View) Units Having Large Screw Terminals with Pressure Plate Contact locks (Typical View) Panel Depth Requirements 1/16 1/4 in. (1.6 6.4 mm)

Dimension A Description Push utton Pilot Light Sel. Switch Cyl. Lock Pot. Push-Pull or Twist Release Push utton Pilot Light Sel. Switch Cyl. Lock Pot. Push-Pull or Twist Release Units with Quick Connect Terminals Units Having Small Screw Terminals with Pressure Plates Non-Illuminated 2-1/4 (57.2) 2-15/32 (62.7) 3-1/2 (88.9) 2-1/32 (51.6) 2-3/4 (69.8) 2-5/16 (59) 2-17/32 (64.3) 3-9/16 (90.5) 2-1/32 (51.6) 2-13/16 (71.4) Illuminated Full Voltage 2-1/4 (57.2) 2-1/4 (57.2) 2-15/32 (62.7) 2-3/4 (69.8) 2-25/32 (70.6) 2-25/32 (70.6) 2-17/32 (64.3) 2-13/16 (71.4) Transformer 2-23/32 (69.1) 2-23/32 (69.1) 2-29/32 (73.8) 3-3/32 (78.6) 2-25/32 (70.6) 2-25/32 (70.6) 2-31/32 (75.4) 3-5/32 (80.1) Non-Illuminated Units Having Large Screw Terminals with Pressure Plates 2-45/64 (68.6) 2-59/64 (74.2) 3-15/16 (100) 3-13/64 (81.4) Illuminated Full Voltage 3-11/64 (80.6) 3-11/64 (80.6) 3-23/64 (85.3) 3-13/64 (81.4) Transformer 3-11/64 (80.6) 3-11/64 (80.6) 3-23/64 (85.3) 3-35/64 (90.1) Approximate Mounting Dimensions Caution: To avoid possible excessive heat, clusters of nine or more continuously illuminated units mounted in a small enclosure should be spaced at 1 1/2 in. (38.1 mm) minimum centers in one direction. Large screw terminal contact blocks require a minimum vertical spacing of 1 37/64 in. (40 mm); selector switches with wing lever knobs require 2 1/4 in. (57.1 mm) vertical and horizontal minimum spacing and large round legend plates require 1 1/2 in. (38.1 mm) minimum spacing. Shipping Weights in unces (kg) Type of Unit Weight Type of Unit Weight Push uttons Non-Illuminated 3-1/4 (0.09) Selector Switches Non-Illuminated 4 (0.11) Illuminated Full Voltage 3-1/2 (0.10) Illuminated Full Voltage 4 (0.11) Transformer 5 (0.14) Transformer 5-1/2 (0.16) Pilot Lights Pilot Light 2-1/4 (0.06) Push-Pull Units Non-Illuminated 4-1/2 (0.13) Push-to-Test 3 (0.09) Pilot Light 4-1/2 (0.13) Illuminated Full Voltage 4-1/2 (0.13) Push-to-Test 5 (0.14) Transformer 5-1/2 (0.16) Cylinder Lock 6 (0.17) Potentiometer Units 4 (0.11) Padlocking Cover 800MR-N6 When using a padlocking cover and depending upon the types of adjacent units involved, the minimum vertical or horizontal spacing may have to be increased for operating clearance.

Dimensions in inches (millimeters). Dimensions are not intended to be used for manufacturing purposes. Legend Plates Standard Half Round Legend Plate Standard Legend Plate Large Size Round Small/Large Legend Plate The ulletin 800MR large half round legend plates are not recommended for use with the twist release units because of the operator knob size. The legend plate is virtually unreadable. Push pull units can be mounted in a 1 1/4 in. minimum horizontal spacing when no legend plate is used. Vertical spacing is 1 1/2 in. when the ulletin 800MR large half round legend plate is used. These ulletin 800MR legend plates consist of ulletin 800T legend plates with 800MR N50 adapter rings. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.