Installation and Assembly:

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

Installation and Assembly: Full Service Video Wall Mount

NEC Display Solutions of America, Inc.

Installation and Assembly: Projector Ceiling/Wall Mount

Installation and Assembly: Wallmount for CPA100 and Whiteboard

Installation and Assembly: Projector Ceiling/Wall Mount

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

NEC Display Solutions of America, Inc.

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 65" Plasma Screens. Models: PLAV70, PLAV70-S

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

Installation & Assembly: Two Piece Suspended Ceiling Plate

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly: Mount - Wall/Ceiling Mount

Installation and Assembly: DUKANE PROJECTOR SHORT THROW WALL ARM

Installation & Assembly: Suspended Ceiling Kit

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Screens

Installation and Assembly: Ceiling mount for LCD screens up to 29"

Models: PLAV70-UNL, PLAV70-UNLP. Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 95" Plasma Screens

Installation and Assembly: Adjustable Extension Column (Pipe) 8" - 11"

Installation and Assembly: Ceiling mount for LCD screens up to 29"

INSTRUCTION MANUAL LCD TV BRACKET WM-3968

Installation and Assembly Manual: Vector Pro II

INSTALLATION GUIDE. Flat Panel Arm Mount BTAR2/37. VESA 200x200 compatible. Support 24" to 37" Screens Max Load Capacity: 80 lbs (36 kg)

Full-motion Wall Mount

Installation and Assembly Manual: PRS, RTR Series Projector Mount

INSTALLATION GUIDE. Flat Panel Arm Mount MLA100-L. VESA 100x100 compatible. Support 10" to 24" Screens Max Load Capacity: 30 lbs (15 kg)

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

INSTALLATION GUIDE Ceiling TV Mount MHP-52

Installation and Assembly: Adjustable Suspended Ceiling Channel Kit

Installation and Assembly: Adjustable Extension Column (Pipe) 8" - 11"

INSTALLATION GUIDE. Flat Panel Arm Mount MHA-800. VESA 500x800 compatible. Support 42" to 63" Screens Max Load Capacity: 200 lbs (91 kg)

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

WARNING. Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

INSTALLATION GUIDE. Flat Panel Arm Mount MHA-72. VESA 750x850 compatible. Support 52" to 72" Screens Max Load Capacity: 300 lbs (136 kg)

Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box

SM-RAZOR-ART2-L / SM-RAZOR-ART2-XL

Installation and Assembly Manual: PRS Series Projector Mount

Installation and Assembly: Dual-Screen Desktop Mount for 10" to 20" LCD Monitors

Installation Instructions

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

Installation and Assembly: 32" - 60" Flat Panel TV Cart

Installation and Assembly - Vision Point LCD Screen Pedestal Stand - 75/100 mm Adapter Plate

Max Load Capacity: 50 lb (22.6 kg) J K

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

Installation and Assembly: Flat Panel Pull-out Swivel Wall Mount

Installation and Assembly: Projector Enclosure

Installing flat panels on the MPL15 wall mount

Projector Ceiling Mount

QLF215 INSTRUCTION MANUAL

QLT25 INSTRUCTION MANUAL

QLF214 INSTRUCTION MANUAL

QLF214 INSTRUCTION MANUAL

Flat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold

Installation Instruction

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Adjustable Wall Mount and Adjustable Mobile Stand for the PolyVision PJ920 Ultra-Short Throw Projector. Installation Guide

Parts List D E. Installation and Assembly- Encore Projector Mount Protected by U.S. Patent No. 6,042,068. Model: PJRL411

Installation and Assembly: Flat-Panel Base Lock-Down Kit for Samsung Display Models

Small Above Fireplace Pull-Down Full-Motion TV Wall Mount

INSTALLATION INSTRUCTIONS

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ēno one Adjustable Wall Mount and Adjustable Mobile Stand Installation Guide

Installation and Assembly: 32" - 60" Flat Panel TV Cart

Installation and Assembly: Wireless Articulating Arm Wall Mount for 42" to 60" Flat Panel Displays

MONOPRICE. Above Fireplace Pull-Down Full-Motion TV Wall Mount. User's Manual P/N 27773

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

Owner s Manual Full Motion Flat Screen Wall Mount

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Assembly Instructions for Model: VMPL3

Assembly InstructIons

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

Installation and Assembly: LCD UPRIGHT STAND FOR PEDESTAL CABINETS

Ceiling Mount - 32" to 60" - Single Installation Instructions

Installation and Assembly:

TP4463. ASSeMBly INSTruCTIONS FLAT PANEL TV MOUNTING SYSTEM OPTION 1 OPTION 2 OPTION 3

TC9217MM-C, TC9220MM-C, TC9227MM-C

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

MPA-9000 Universal Ceiling Projector Mount Kit

A401 Instruction Manual

PHTM100 - Phantom 100 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 25 lbs with 100mm or 75mm Mounting Patterns

19 to 39 TV WALL MOUNT - FULL MOTION

Dual Arm Tilt LCD Mount

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

Planar FWMG-MXL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Transcription:

Installation and ssembly: Universal Projector Wall rm Models: PST-2955, PST-2955-W, PST-2955, PST-2955-W Max UL Load Capacity: 35 lb (5.8 kg) 2300 White Oak Circle urora, Il 60502 (800) 865-22 Fax: (800) 359-6500 www.peerless-av.com ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Note: Read entire instruction sheet before you start installation and assembly. Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, for US customers please call Peerless customer care at -800-865-22, for all international customers, please contact your local distributor. This product should only be installed by someone of good mechanical aptitude, has experience with basic building construction, and fully understands these instructions. Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. Never exceed the Maximum Load Capacity. See page one. If mounting to wood wall studs, make sure that mounting screws are anchored into the center of the studs. Use of an "edge to edge" stud finder is highly recommended. lways use an assistant or mechanical lifting equipment to safely lift and position equipment. Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power. This product is intended for indoor use only. Use of this product outdoors could lead to product failure and personal injury. This product was designed to be installed on the following wall construction only; WLL CONSTRUCTION Wood Stud Wood Beam Solid Concrete Cinder Block HRDWR RQUIRD Included Included Included Included Tools Needed for ssembly stud finder ("edge to edge" stud finder recommended) level drill 5/32" bit (wood installation) 5/6" bit (concrete/cinder block installation) phillips screwdriver Table of Contents Parts List...3 Installation to Wood Studs... 4,6 Installation to Concrete/Cinder Block... 5,7 ssembly of djustment Tube...8 Installing Projector Mount...8 Routing Cables...9 Visit the Peerless Web Site at www.peerless-av.com 2 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Before you start check the parts list to ensure all of the parts shown are included. Parts List PST-2955 PST-2955-W PST-2955 PST-2955-W Description Qty Part # Part # Part # Part # wall arm 055-92 055-292 055-92 055-292 B adjustment tube 056-334 056-2334 056-334 056-2334 C 4 mm allen wrench 560-9646 560-9646 560-9646 560-9646 D M5 x 0 mm serrated socket pin screw 2 50-26 50-2063 50-26 50-2063 #4- x 2.5 wood screw 4 5S-05-C03 5S-05-C04 5S-05-C03 5S-05-C04 F tube cap 590-263 590-263 590-263 590-263 concrete anchor 4 590-0320 590-0320 590-0320 590-0320 H /4"-20 socket pin screw 2 520-054 520-2069 520-054 520-2069 I /4"-20 flat washer 2 540-078 540-2078 540-078 540-2078 J projector mount PRS-UNV PRS-UNV-W PRS-UNV PRS-UNV-W wall plate 055-923 055-2923 L 5/6-8 x /2 carriage bolt 4 520-9207 520-2047 M 5/6-8 serrated flanged lock nut 4 530-06 530-206 NOT: Some parts may appear slightly different than illustrated. B C D F H I J L M Visit the Peerless Web Site at www.peerless-av.com 3 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Installation to Wood Stud Walls for PST-2955, PST-2955-W Models Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. Never tighten in excess of 80 in. lb (9 N.M.). Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended. When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8". Note: For PST-2955 models, refer to page 6. Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based on its edges, draw a vertical line down the stud s center. Place wall arm () on wall as a template. Mark the center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-/2" (65 mm) deep. Secure wall arm () to wood stud using four #4 x 2-/2" wood screws () as shown. Optional: Rotate wall arm 80 to position the arm closer to the ceiling. Skip to Step 2. Visit the Peerless Web Site at www.peerless-av.com 4 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Installation to a concrete or cinder block wall for PST-2955, PST-2955-W Models Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum compressive strength of 2000 psi. When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet STM C-90 specifications and have a minimum nominal width of 8". When installing Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally " (25 mm) minimum from the side of the block. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity. Never attach concrete expansion anchors to concrete or cinder block covered with plaster, drywall or other finishing material. Note: For PST-2955 models, refer to page 6. Drill four 5/6" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors () in holes flush with wall as shown. ttach wall arm () using four #4 x 2 -/2" wood screws () as shown in Illustration and, 2, and 3. Tighten all fasteners. Optional: Rotate wall arm 80 to position the arm closer to the ceiling. Skip to Step 2. Drill holes and insert anchors (). 2 Place plate () over anchors () and secure with screws (). concrete surface Tighten wood screws firmly, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. 3 Never tighten in excess of 80 in lb (9 N.M.). Tighten all fasteners. SOLID CONCRT CINDR BLOC Illustration Visit the Peerless Web Site at www.peerless-av.com 5 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Installation to Wall Plate For PST-2955, PST-2955-W Models Secure wall arm () to wall plate () using four carriage bolts (L) and lock nuts (M). L M Installation to Wood Stud Walls Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components. Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. Never tighten in excess of 80 in. lb (9 N.M.). Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is highly recommended. When installing Peerless wall mounts on a wood stud wall covered with gypsum board (drywall), verify that the wood studs are a minimum of 2" x 4" nominal size. Do not install over gypsum board thicker than 5/8". - Use a stud finder to locate the edges of the stud. Use of an edge-to-edge stud finder is highly recommended. Based on its edges, draw a vertical line down the stud s center. Place wall plate () on wall as a template. Mark the center of the four mounting holes. Drill four 5/32" (4 mm) dia. holes 2-/2" (65 mm) deep. Secure wall plate () to wood stud using four #4 x 2-/2" wood screws () as shown. Skip to Step 2. Optional: Rotate wall arm 80 to position the arm closer to the ceiling. Visit the Peerless Web Site at www.peerless-av.com 6 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Installation to a concrete or cinder block wall When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum compressive strength of 2000 psi. When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet STM C-90 specifications and have a minimum nominal width of 8". Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally " (25 mm) minimum from the side of the block. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity. Never attach concrete expansion anchors to concrete or cinder block covered with plaster, drywall or other finishing material. Drill four 5/6" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors () in holes flush with wall as shown. ttach wall plate () using four #4 x 2 -/2" wood screws () as shown in Illustration and, 2, and 3. Tighten all fasteners. Optional: Rotate wall arm 80 to position the arm closer to the ceiling. Tighten wood screws firmly, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power. Never tighten in excess of 80 in lb (9 N.M.). Drill holes and insert anchors (). 2 3 Place plate () over anchors () and secure with screws (). concrete surface Tighten all fasteners. Illustration Visit the Peerless Web Site at www.peerless-av.com 7 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

ssembly of djustment Tube 2 Slide adjustment tube (B) into wall arm () and adjust to the desired projector throw distance as shown. Using two separate slots on wall arm (), lock position using two M5 x 0 mm screws (D) as shown below. Note: Securing adjustment tube (B) into wall arm () requires two slots. D B TWO SCRWS RQUIRD THROUH TWO SLOTS B MXIMUM XTNSION SHOWN Installing PRS Projector Mount 3 Installing PRS projector mount to wall arm assembly: ttach PRS projector mount (J) to adjustment tube (B) using two /4-20 phillips screws (H) and two flat washers (I) as shown in figure 3.. I J H fig. 3. Visit the Peerless Web Site at www.peerless-av.com 8 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4

Routing Cables 4 Routing Cables through PRS projector mount and wall arm assembly: uide projector cables into openings in projector mount and wall arm assembly as shown below. Insert Tube Cap (F) into end of adjustment tube (B). Cables must be removed from projector before routing through wall arm. Follow projector mount (PRS) instructions to install projector. B F PROJCTOR CBLS Visit the Peerless Web Site at www.peerless-av.com 9 of 9 ISSUD: 03-26-09 SHT #: 055-9259-8 05-6-4 203, Peerless Industries, Inc. ll rights reserved. ll other brand and product names are trademarks or registered trademarks of their respective owners. Peerless Industries, Inc. 2300 White Oak Circle urora, Il 60502 www.peerless-av.com