Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Similar documents
Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

CSM_G7S-_-E_DS_E_7_1

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Ordering Information. Power Relay G2A. Model Number Legend Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control

MY-GS CSM_MY-GS_DS_E_2_1

G7K. Latching Relay. Compact Mechanical Lock Latching Relays with Manual Buttons. Model Number Structure. Ordering Information

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

MK CSM_MK_DS_E_2_2. Compact Power Relays. A Wide Variation of Octal Pin Power Relays. Model Number Structure

Fluoro plastic housing for highest chemical and detergent resistance

Model Number Structure

Safety Monitoring Relays

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Model Number Structure

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Switch Mode Power Supply

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Name Model Specifications/Design ID Tag V700-D23P31 20 dia. t 2.7 mm Coin-shaped 256 bytes (with user area of 240 bytes)

AC 24, 110, 120, 230, 240 DC 6, 12, 24, 48 LED indicator with test button G2R-1-SNI (S) G2R-2-SNI (S) Diode

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

2. Terminal Shape P: PCB terminals B: Screw terminals T: Quick-connect terminals (#250 terminal)

DPDT+DPST-NO MM4KP-JD MM4XKP-JD

G70R-SOC08 CSM_G70R-SOC08_DS_E_2_1

E8EB-N0C2B E8EB-N0B2B

G5Q. Ordering Information. Specifications. PCB Relay. Compact, High Isolation Relay J COIL RATINGS. 638 PCB Relay G5Q

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

SPECIFICATIONS. For Reference. This specification sheet is for reference only, Please request it again if a specification for receipt is necessary.

E3X-DRT21/SRT21/CIF11

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Relays with Forcibly Guided Contacts G7SA

Sensing method Sensing distance Model

Phase-sequence Phase-loss Relay

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Power Relays G7Z. Model Number Structure. Model Number Legend Relay with Auxiliary Contact Block. New Product Relay

Model Number Structure

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

Switch Mode Power Supply

Model Number Structure

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Alternate Operation Relay 61F-AN/-APN2

3. Contact Form A: SPST-NO

Model Number Structure

E6F-CWZ5C (1000P/R) 2M

V700-series. Electromagnetic Inductive RFID System. ID Tag. Antenna. Controller

G5NB. A Miniature Relay with 1-pole 3A/5A Switching Capability and 10 kv Impulse Withstand Voltage. Application Examples. Model Number Legend

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Single-phase Current Relay

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

4. Classification E: High capacity. 3. Terminal Form Blank: Tab terminals (#250 terminals) Tab terminals #250 SPST-NO

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

SPST-NO SPDT DPST-NO DPDT

Single-phase Voltage Relay

Classification Enclosure rating Contact form Contact material

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A

E6F-CWZ5C (1000P/R) 2M

G8P. PCB Power Relay. Model Number Legend. Application Examples. Ordering Information

256, 360, 720, 1,024. E6C3-AN1E 256P/R 1M Voltage output Binary VDC E6C3-AN2E 256P/R 1M

20 Series Power Relays

Surface-mounting Relay

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Model Number Structure

SPST-NO SPDT DPST-NO DPDT

* (110 VAC) in this catalog have been discontinued at the end of March L 2KM: Long-distance (for 2 km)

Multipoint Temperature Controller

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

PCB Relay. Contact form Terminal Single-side stable Single-winding latching Double-winding latching

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

LED Displacement Sensor

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Classification Contact form Contact type Contact material Enclosure Rating Model Standard DPDT Bifurcated crossbar Ag (Au alloy) Fully sealed G5V-2

Floatless Level Switch (Ultra High-sensitivity Type) 61F-UHS/-HSL

Features. 2-Dimensional Code Reader (Fixed Type) V530-R150E-3, EP-3

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Phase-sequence Phase-loss Relay

CV : 16 A, pinning 5 mm,: switching at 105 C 6. Market Code None : General purpose HA : Home Appliance according to IEC/EN

NEW. Better Productivity by Standstill and Low-speed Monitoring

OMRON MK-I / -S RELAY

G2RL-1A G2RL-1 G2RL-2A G2RL-2

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Model Number Structure

E3JM/E3JK. Two Models Contribute to Overall Cost Reduction. Built-in Power Supply Photoelectric Sensor. Ordering Information

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Three-phase Undervoltage and Phase-sequence Phase-loss Relay

Resolution (pulses/rotation) 100, 200, 300, 360, , 720, 800 1,000, 1,024, 1,200 1,500, 1,800, 2,000 2,048, 2,500, 3, , , 360, 500

Three-phase Asymmetry and Phase-sequence Phase-loss Relay

Safety Relay Unit. OFF-delay time

Transcription:

Relays with Forcibly Guided Contacts G7S CSM_G7S_DS_E_5_ Relays Conforming to EN Standard Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery (Machinery Directive). Helps avoid hazardous machine status when used as part of an interlocking circuit. Track-mounting and Back-mounting Sockets are available. Be sure to read the Safety Precautions on page 5 and the Precautions for All Relays with Forcibly Guided Contacts. Model Number Structure Model Number Legend G7S-@A@B 2. NO Contact Poles 4: 4PST-NO 3: 3PST-NO 2. NC Contact Poles 2: DPST-NC 3: 3PST-NC Ordering Information Relays with Forcibly Guided Contacts Sockets Type Poles Contact configuration Rated voltage Model 4PST-NO, DPST-NC G7S-4A2B Standard 6 poles 24 VDC 3PST-NO, 3PST-NC G7S-3A3B Type Rated voltage Model Track-mounting Common for track mounting and screw mounting 24 VDC P7S-4F-END Back-mounting PCB terminals --- P7S-4P-E

Specifications G7S Ratings Coil Rated voltage Note:. The rated current and coil resistance are measured at a coil temperature of 23 C with tolerances of ±5%. 2. Performance characteristics are based on a coil temperature of 23 C. 3. The maximum voltage is based on an ambient operating temperature of 23 C maximum. Contacts Item Characteristics of Sockets Note: Use the P7S-4F-END in the ambient humidity range of 35 to 85%. * The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured. Characteristics Rated current (ma) Coil resistance (Ω) Must operate voltage (V) Must release voltage (V) Max. voltage (V) Power consumption (W) 24 VDC 30 800 80% max. 0% min. 0% Approx. 0.8 Item Load Resistive load Inductive load (cos φ = 0.4, L/R = 7 ms) Rated load 240 VAC: 3 A, 24 VDC: 3 A 240 VAC: 3 A, 24 VDC: A Rated carry current Maximum switching voltage Maximum switching current Note: The above values are initial values. *. Measurement conditions: 5 VDC, 0 ma, voltage drops. *2. Measurement conditions: Rated voltage operation Ambient operating temperature: 23 C Contact bounce time is not included. *3. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured. *4. The durability is for an ambient temperature of 5 to 35 C and an ambient humidity of 25% to 75%. *5. The failure rate is based on an operating frequency of 60 operations/min. 6 A 250 VAC, 24 VDC Model Continuous current Dielectric strength Insulation resistance P7S-4@ 0 A 2,000 VAC for min. between terminals,000 MΩ min. * Contact resistance * Operating time *2 Release time *2 Maximum operating frequency Insulation resistance *3 Dielectric strength Vibration resistance Shock resistance Durability *4 Mechanical Rated load Destruction Malfunction 00 mω max. 50 ms max. 50 ms max. 8,000 operations/h,800 operations/h 00 MΩ min. Destruction,000 m/s 2 Malfunction 00 m/s 2 Mechanical Electrical Failure rate (P level) (reference value *5) Ambient operating temperature 2,500 VAC, 50/60 Hz for min. (,500 VAC between contacts of same polarity) 0 to 55 to 0 Hz, 0.75-mm single amplitude (.5-mm double amplitude) 0 to 55 to 0 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) 6 A 0,000,000 operations min. (at approx. 8,000 operations/h) 00,000 operations min. (at the rated load and approx.,800 operations/h) 5 VDC, ma Ambient operating humidity 5% to 85% Weight 25 to 70 C (with no icing or condensation) Approx. 65 g 2

Engineering Data G7S Durability Curve (Rated Resistive Load) No. of operations (x0 4 operations) 50 30 0 5 3 AC or DC resistive load 0 2 3 4 5 6 7 Contact current (A) Dimensions (Unit: mm) Relays with Forcibly Guided Contacts G7S-4A2B G7S-3A3B 62 max. 58 22.5 max. Terminal Arrangement/Internal Connection Diagram (Bottom View) G7S-4A2B 6 7 6 37 max. 0.8 0.5 5 min. 0.6.5 8 4.5 24 VDC 0 3 4 33 34 5 52 23 24 43 44 6 62 G7S-3A3B 0 3 4 33 34 5 52 24 VDC Fourteen, 23 24 4 42 6 62.8 dia. 7 6 Mounting Hole Dimensions 8±0. 4.5±0. 2±0. 35±0. 7±0. 3 3

G7S Sockets Track-mounting Socket P7S-4F-END 40 max. 33±0. Indicator Fourteen, M3.0 8 Terminal Arrangement/Internal Connection Diagram (Top View) 24 23 4 3 0 4 42 43 44 52 33 34 62 6 5 4 7.5 Mounting Hole Dimensions 37 80 max. 7 33±0. Two, M3.5- or 4.0-dia. holes 5 (5) 90.5 max. 3. 5.9 Back-mounting Socket (PCB Terminals) P7S-4P-E 23.5 max. 70.5 max. 28 ±0.2 Two, 6.5 dia x 8 depth Terminal Arrangement/Internal Connection Diagram (Bottom View) With G7S-4A2B mounted Mounting Hole Dimensions 28 ±0.2 4.2 2.8 (2) (6.9) 57 max. With G7S-3A3B mounted 4.5 8 3.2 Fourteen, 2.5 dia. 6 7 5 7=35 Two, 3.6 dia. 6 5 7=35 7 (5) 6.9 8 4.5 4. 23.5 max. 4

G7S Certified Standards EN Standards, VDE Certified EN680- (Electromechanical non-specified time all-or-nothing relays) EN50205 (Relays with forcibly guided (linked) contacts) UL standard UL508 Industrial Control Devices CSA standard CSA C22.2 No. 4 Industrial Control Devices Forcibly Guided Contacts (from EN50205) If an NO contact becomes welded, all NC contacts will maintain a minimum distance of 0.5 mm when the coil is not energized. Likewise if an NC contact becomes welded, all NO contacts will maintain a minimum distance of 0.5 mm when the coil is energized. Safety Precautions Refer to the Precautions for All Relays and Precautions for All Relays with Forcibly Guided Contacts. Precautions for Correct Use Wiring Use one of the following wires to connect to the P7S-4F-END. Stranded wire: 0.75 to.5 mm 2 Solid wire:.0 to.5 mm 2 Tighten each screw of the P7S-4F-END to a torque of 0.78 to 0.98 N m. Refer to the internal connections diagram of the G9S Safety Relay Unit for an application example of the G7S. Wire the terminals correctly with no mistakes in coil polarity, otherwise the G7S will not operate. Cleaning The G7S is not of enclosed construction. Therefore, do not wash the G7S with water or detergent. 5

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2009.2 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2009 All Right Reserved.