IR Radiator. Configuration. Architectural Specification. Highlights. Used With

Similar documents
LA-140 Stationary IR Radiator

LT-800 Stationary Transmitter

LT-800 Stationary FM Transmitter

WIR TX90. SoundPlus Infrared Transmitter INFRARED SPECIFICATION DATA

WIR TX90. SoundPlus Infrared Transmitter INFRARED SPECIFICATION DATA

LT-700 Portable FM Display Transmitter

Courtrooms Schools Universities Cinema Churches

WIR SYS 3. SoundPlus Value Courtroom System ADA Courtroom Assistive Listening System INFRARED SPECIFICATION DATA

SoundPlus Infrared System Model WIR SYS 90 ADV

C O M M U N I C A T I O N

Personalize. Simplify. Customize.

SoundPlus Infrared System Model WIR TX925

Wireless Microphone Technology. audio-technica.com

WMS 450 Wireless Microphone System

system 600 s p e c i f i c a t i o n s : S T A R S O U N D i n f r a r e d s y s t e m / 2. 8 M H z

User s Guide. INFRARED CLASSROOM SYSTEM IRR-40P RECEIVER IRN-10 MIC/TRANSMITTER IRH-15c MIC/TRANSMITTER IRD-60 EXTERNAL SENSOR

Installation Guide & User Manual Sound Plus Infrared System, Model WIR 950

Intelix DIGI-VGASD-R Installation Manual

Model 1791 VHF Radio User's Manual

Dear Valued Customer,

Intelix DIGI-VGASD-S Installation Manual

UHF Wireless System CONTENTS

Dear Valued Customer,

Intelix DIGI-VGASD Installation Manual

PPA 377. Personal PA FM Listening System FM SPECIFICATION DATA. System Includes:

Intelix DIGI-V3SD-R Installation Manual

Dear Valued Customer,

Installation Guide & User Manual

Synthesized Base Station Transmitter

Assistive Listening Language Interpretation Soundfi eld Tour Group Conferencing

Synthesized Base Station Transmitter

Telex. Operating Instructions UR-700

IntelPage 5W (POCSAG) Transmitter

ListenRF Stationary RF Brochure

Dear Valued Customer,

USER S MANUAL AF LEVEL SET AF LEVEL SET AF LEVEL SET AF LEVEL SET ADS ADS ADS ADS POWER dBu BATT INFRARED

Southern Avionics Company

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

UMC16B/UMC16BL. Wideband UHF Antenna Multicoupler INSTRUCTION MANUAL. Fill in for your records: Serial Number: Purchase Date:

Infra-Red Language Distribution System

AUDIOLINK PRO. Warranty Conditions INSTRUCTION MANUAL M110 INFRARED TRANSMITTER

WIR TX925, WIR SYS 1 Two-Channel Infrared Listening Systems

specifications: S TARS OUND infrared system 600 system /2.8 MHz Wireless, two-channel infrared emitter and personal receivers

DMS 700 Digital Microphone System

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

A01-eNETL2TUV_Manual_RevH.doc. GE MDS enetl2t/u/v Manual P/N A01 Rev H

Technical Equipment Specification

Creating Exceptional Listening Experiences LISTEN TECHNOLOGIES PRODUCT LINE CATALOG AUSTRALIA.

Transparent 24-bit digital audio captures every performance detail. Incredibly Efficient Wireless. Powerful Networking Features

CATALOG. Network Access & Connectivity

Telex. Operating Instructions USR-100

Installation Guide & User Manual

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Important Safety Information

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

WARNING! IMPORTANT NOTICE

DIGITAL WIRELESS. Transparent 24-bit digital audio captures every performance detail. Incredibly Efficient Wireless. Powerful Networking Features

100 BaseT transmission; Network speeds up to 93 Mbps*; Up to 8,000ft (2,500m)*

Product Catalog Spring 2017 AmericanAmpTech.com

X-Band Redundant LNA Systems

ASTRO 25 The STR 3000 is compatible with Project MHz and 800 MHz trunking systems.

Tower Light with Wireless Switch Control Box

Installation Guide & User Manual

WLS-5500 Receiver (KSF & W26)

J kw AM Transmitter

C-Band Redundant LNA Systems

APX Mobile and Portable Automated Test and Alignment

Tuner Base Unit MB-8N. UHF Synthesized Tuner Unit WRU-8N

UAT-600 Series. amprobe.com

INSTALLATION MANUAL. CTA-30RK-550 Rack Mount Distribution Amplifier

SL-6 Powering and Wireless System for the 688. User Guide

AC Active Transmitter Combiner 8:1

NETWORK PERSONAL PA FM LISTENING. Your audience is ready and waiting to be. Wireless, radio-frequency systems

HyperLink Wireless Low PIM MHz Omni-Directional Ceiling Antenna Model: HG35805CUPR-NF

User s Manual LR-100 Stationary Receiver / Power Amplifier

commercial sound / 20 13

INSTALLATION GUIDE & USER MANUAL

Innovative thinking. Unwavering quality. Exceptional people. Quick Reference

UHF WIRELESS M ICROPHONE S YSTEMS

AT-5000 Professional Underground Cable / Pipe Locator System

datasheet IMPACT 50 IMPACT SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Attractive injection moulded enclosure 100 watt power rating

GAI-TRONICS A Hubbell Company EQUIPMENT SPECIFICATION GAI-TRONICS MASS NOTIFICATION / PUBLIC ADDRESS SYSTEM COMPONENTS

MULTILINK LT ENGLISH USER S MANUAL

900 MHz Antenna Sharing Combiner ASC900VG11A

A Division of Williams AV U.S. COMMERCIAL SOUND PRODUCTS 2018 CATALOG

14 ANT-NP1 Non-penetrating Mast Antenna Kit 1 Section para " X 18" Wire Guard for 16" Clocks 2 Section para 2

OWNER S MANUAL 311DRH 311DR 221R 211R 200R 31LT 31IT 32BT 32IT 31HT 31XT

850 MHz Antenna Sharing Combiner ASC850VG12A

ASSISTIVE LISTENING SYSTEM Multi Channel RF Wireless

Product Description 2-1

Acterna DSAM Product Family

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM.

DR-TRC105-EV Evaluation Kit. User s Guide

IRIDIUM ACTIVE ANTENNA - AA511

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

Family. Enterprise-grade 2x2, 2-stream, n/ac access points for medium-density environments, as well as IoT and location-based services

HyperLink Wireless Low PIM DAS 2x2 MIMO Ceiling Antenna Model: HG72706DPCUPR-NF

Transcription:

IR Radiator Don t miss a single sound. The LA-140 IR radiator/emitter packs high infrared power in a small and attractive design, with your choice of grey or white packaging. Designed for easy installation using standard components, the LA-140 is powered via CAT-5 cabling while the RF Configuration LA-140-GY (Grey) LA-140-WH (White) modulated carriers are delivered via standard RG-58 coaxial cable. Mounting brackets are included for wall, ceiling, desk, mic stand and tripod mounting. Power can be supplied by the LT-82 transmitter or from a separate power supply (LA-205). Built-in delay compensation prevents signal cancellation (multi-path) problems and eliminates the piled-up cabling that is required with other systems. The LA-140 is used for government compliance (such as ADA), assistive listening, language interpretation, live theatre, houses of worship, courtrooms, secure rooms and for auditory description. Highlights Outstanding coverage 10,000 sf (929 sm) Two radiators can be powered from one LT-82 transmitter or optional power supply using standard CAT-5 cabling - eliminating the need for multiple cables White or grey color allows for a variety of atheistic settings Includes wall, ceiling, desk, mic stand and tripod mounting brackets gives multiple options for mounting Units can be horizontally or vertically mounted together - doubles the power in a small footprint Radiator diodes are turned off if no audio signal is present at the transmitter after 30 minutes saves radiator diode life Architectural Specification The radiator-emitter shall have a transmitting area of no less than 10,000 square feet (one carrier) or greater for each radiator specifi ed when used with specifi ed receiver. The radiator shall be powered via CAT-5 cabling and the RF from the transmitter shall be carried by 50 ohm coaxial cable. The radiator shall have three indicating LEDs for power, no carrier present and carrier present. The radiator LEDs shall be deactivated after 30 minutes if there is no audio signal present from the transmitter. The radiator shall come in a white or grey color and shall include all of the mounting hardware capable of mounting the radiator on a wall, on a ceiling, in a corner, on a desk, on a mic stand or on a tripod. The Listen LA-140 is specifi ed. Delay compensation - ensures no drop out in the IR signal Requires Used With LR-42 Stethoscope 4-Channel IR Receiver LR-44 Lanyard 4-Channel IR Receiver Includes LA-140 IR Radiator Mounting hardware for one unit (allows for wall, ceiling, desk, mic stand and tripod mounting) 25 feet (7.6 meters) of RG-58 coaxial cable 25 feet (7.6 meters) of CAT-5 cable uick Reference Card LA-140 Page 1

10 7 6 4 1 3 5 8 2 9 Product Features 1. RF input connector - this is the connection from the LT-82 transmitter or from the output of another radiator. 2. RF output connector - use this to send the RF input to another radiator. 3. Delay compensation - allows you to set different delays so all radiators have the same timing. This prevents drop-outs caused by signals out of phase. 4. LED illumination switch - use this to turn on/off the illumination of the front panel LEDs. 5. Compatibility switch - use this switch when using a non-listen transmitter. 6. Termination switch - use to terminate the coaxial cable. 7. Power connection from LT-82 transmitter or optional power supply (LA-205). 8. Power connection to (optional) second radiator. 9. LEDs - Three LEDs that indicate power, no carrier present and carrier present. 10. Color: Two different colors. Available in Grey (LA-140-GY) or White (LA-140-WH). Mounting brackets and supplied cables match the radiator. LA-140 Page 2

Accessories LA-342 IR Dual Radiator Mounting Bracket LA-205 (for mounting two radiators vertically or IR Extended Power Supply horizontally) (powers two LA-140 radiators) -includes RG-58 coaxial cable and CAT-5 cable to Note: You will only need the LA-205 if you interconnect the two radiators are using more than two LA-140 radiators per LT-82 transmitter or if you wish to remote power the radiator(s). LA-70 CAT-5 Cable specify length LA-115 RG-58 BNC to BNC Coupler LA-112 RG-58 50 Ohm Coaxial Cable specify length LA-71 RJ-45 CAT-5 Connector (Pkg. of 10) LA-391 RG-58/50 Ohm Coaxial Cable preassembled, specify length LA-127 RG-58 BNC Connector LA-393 RJ-45/CAT-5 Cable preassembled, specify length LA-72 RJ-45 to RJ-45 CAT-5 Coupler LA-337 IR Radiator Floor Stand LA-140 Page 3

RF Controls Indicators Power Physical Specifictions Frequency Range Input Output Compliance Coverage Area User Controls Red LED Yellow LED Green LED Input Output Emitter Power Dimensions (H x W x D) Color Unit Weight Unit Weight with Wall/ Ceiling Mounting hardware Shipping Weight LA-140 1 MHz - 5 Mhz BNC Connection. -25dbm to -5dbm input nominal BNC Connection. -15 dbm nominal FCC Part 15, Industry Canada, CE 10,000 sf (929 sm) when used with Listen Receivers Termination Switch, Delay Compensation Switch, Indicator LEDs on/off Indicates power is present Indicates no carrier is present. Indicates carrier and power are present and radiator is emitting IR signal. RJ-45 connector. 30VDC, powered from transmitter via CAT-5 cable or optional LA-205 power supply. RJ-45 connector. 30 VDC, powers up to one additional radiator. (Maximum two radiators powered from each LT-82 transmitter) 3 Watts 5.5 x 8 x 2.6 inches (140 x 203 x 66 mm) LA-140-GY (Grey), LA-140-WH (White) 2.1 lbs (.95 kg) 2.35 lbs (1.05 kg) 4 lbs (1.8 kg) Environmental Temperature - Operation -10 C (14 F) to +40 (104 F) Temperature - Storage -20 C (-4 F) to +50 (122 F) Humidity 0 to 95% relative humidity, non-condensing LA-140 Page 4

1 1 2 3 4 2 3 4 1 1 2 3 4 2 3 4 Don t miss a single sound. Stationary IR Block Diagram Basic Single Channel/Single Radiator System LA-140 IR Radiator Power CAT-5 Cable RF RG-58 50 ohm Cable IR LR-42 IR Stetho Receiver Mounting hardware for radiator included with radiator LR-44 IR Lanyard Receiver Stationary IR Block Diagram Multi-Channel/Radiator System Up to four LT-82 transmitters can be daisy chained together (using RG-58 cable) to create a multi-channel system Power CAT-5 Cable RF RG-58 50 ohm Cable Up to 100 LA-140 radiators can be daisy chained together (using RG-58 cable) to provide sufficient IR power for most applications LA-140 IR Radiator IR LR-42 IR Stetho Receiver RF RG-58 50 ohm Cable Power CAT-5 Cable LA -89 RG-58 Multi-carrier Interconnection Cable (included) IR LA-140 IR Radiator LR-44 IR Lanyard Receiver Radiator Power: Radiators can be powered from the LT-82 (up to two radiators) or an additional power supply (LA-205) can power up to two radiators Radiator RF: RF from the last LT-82 must be daisy chained from radiator to radiator LA-140 Page 5

Radiator Footprint 60 50 40 30 20 10 0 4 TX 2 TX 1 TX 10 20 30 40 50 60 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Except in small rooms it is recommended that at least two radiators be used to ensure good coverage and minimal shading. Listen radiators (when used with Listen receivers) will cover approximately 10,000 sf (929 sm) for one channel as indicated in the diagram below (note the coverage decreases as the number of channels goes up). For two channels, one radiator will cover 5,000 sf (465 sm) and for four channels, one radiator will cover 2,500 sf (232 sm). LA-140 Page 6

Related Systems LS-80-SIR Basic Stationary IR System Includes: (1) (1) LA-140 Stationary IR Radiator (4) LR-42 Stethoscope 4-Channel IR Receivers (4) LA-363 High Performance AAA Alkaline Battery sets (Pkg of 2) (1) LA-304 ADA Compliance Signage Kit LS-81-SIR Performance Stationary IR System Includes: (1) (1) LA-326 Universal Rack Mounting Kit (2) LA-140 Stationary IR Radiator (4) LR-42 Stethoscope 4-Channel IR Receivers (4) LA-363 High Performance AAA Alkaline Battery sets (Pkg of 2) (1) LA-351 8-Unit IR Receiver Storage Station (1) LA-304 ADA Compliance Signage Kit LS-82-SIR Advanced Installed IR System Includes: (1) (1) LA-326 Universal Rack Mounting Kit (2) LA-140 Stationary IR Radiator (8) LR-42 Stethoscope 4-Channel IR Receivers (8) LA-364 NiMH Rechargeable Battery Pack (1) LA-350 8-Unit IR Receiver Charging/Storage Station (1) LA-304 ADA Compliance Signage Kit LS-83-SIR 4-Channel, 48-Listener Stationary IR System Includes: (4) (2) LA-326 Universal Rack Mounting Kit (8) LA-140 Stationary IR Radiator (48) LR-42 Stethoscope 4-Channel IR Receivers (48) LA-364 NiMH Rechargeable Battery Pack (6) LA-350 8-Unit IR Receiver Charging/Storage Station (2) LA-304 ADA Compliance Signage Kit X 6 X 4 X 4 LA-140 Page 7

Frequently Asked uestions How much coverage is provided with the LA-140? A Approximately 10,000 square feet (929 square meters). Does the number of audio sources (carriers) affect the coverage? A Yes. For two sources (carriers), the coverage per carrier is halved. For four carriers, the coverage per carrier is one-fourth. How many radiators can you use on a system? A Up to 100. How many radiators will I need? A Refer to the technical resource section of the Listen website for assistance in making this calculation. Does the LA-140 come with a power supply? A No. You must use either the power supply included with the LT-82 transmitter or purchase the optional LA-205 power supply. How is power delivered to the radiator? A Power is delivered with CAT-5 cables (connected between the radiator and either the LT-82 transmitter or the optional LA-205 power supply). How many radiators can be powered from the LT-82 or LA-205 power supply? A Two. What is the purpose of the delay compensation switch? A This switch allows you to set up delay timing in a multi-radiator system so that each radiator receives the carrier at exactly the same time. This prevents signal dropouts that can be caused by out-of-phase signals (multi-path). With Listen s delay compensation switch, it is not necessary to cut all of your coaxial cables to the same length - your shorter runs can use shorter cables, keeping your installation clean (and cost-effective). How do I connect multiple radiators? A You can daisy-chain the carrier between all radiators using RG-58 cables. Power for up to two radiators can be daisy-chained using a short length of CAT-5 cabling or you can power two radiators off one transmitter Can I disable the LEDs on the radiator? A Yes, the LEDs can be turned off at a switch on the back of the radiator. How many emitting diodes does the LA-140 have? A The LA-140 radiator has 84 diodes. It has seven columns of diodes with twelve diodes each. If one diode goes out, you will lose only the diodes on that column. LA-140 Page 8