By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Similar documents
EMC Test report for Plug-in adaptor Models PM1Wab-ccc

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC Test report for LED Panel Light Models , , , , ,

By order of American Power Conversion Holdings Inc. at New Taipei, Taiwan. Author : Harry Deng Reviewed : Tim Yan Pages : 53 pages Annex : NIL

EMC standards. Presented by: Karim Loukil & Kaïs Siala

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC Test Report. Report Number: M030826

2620 Modular Measurement and Control System

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

EMC VERIFICATION SUMMARY Report No.: SZHH

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Power Quality Issues from an EMC Point of View

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

One-day Conference 18 March Power Supply, EMC and Signalling, in Railway Systems

EMC TEST REPORT. Report No.: CE10-LIE040101E

Types of EMC measures

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 14 to 18 December EMC standards

Training Course on Conformity and Interoperability, Tunis-Tunisia, from 11 to 15 April EMC standards

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

Test Verification of Conformity

CONFORMANCE TEST REPORT FOR EN /-6

TEST REPORT... 1 CONTENT...

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

BIODEX MULTI- JOINT SYSTEM

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

EMC test report AU01+E04

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCES EMITTED FROM LIGHTING EQUIPMENT INSTALLED IN TELECOMMUNICATION CENTERS

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

Electromagnetic compatibility Guidance and manufacturer s declaration DIN EN :2007 (IEC :2007)

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

5.3 TEST SETUP AND PROCEDURE TEST DATA MEASUREMENT UNCERTAINTY FLICKER USED TEST EQUIPMENT...18

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

C E R T I F I C A T I O N

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

1 SUMMARY OF STANDARDS AND RESULTS

TEST REPORT. Power Spout PLT V. tested to the specification

Test Report GUANGDONG EAST POWER CO., LTD

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

Declaration of Conformity.

TECHNICAL REQUIREMENTS FOR ELECTROMAGNETIC DISTURBANCE EMITTED FROM TELECOMMUNICATIONS EQUIPMENT

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

BUREAU VERITAS. itaste svd

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

Declaration of Conformity

Content. Report No. SH Page 2 of 22

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

r(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

Electromagnetic Compatibility

Bulk Current Injection instead of Radiated immunity testing, in the range from 1 MHz upto 1 GHz: Measuring results

Unilab(Shanghai) Co.,Ltd. Report No. : UL CE010-1 Page 1 of 27 EMC TEST REPORT

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

C E R T I F I C A T I O N

Test Specification for Type Approval

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EMC Bayswater Pty Ltd. EMC COMPLIANCE REPORT In accordance with: AS/NZS CISPR 15: Indice Ecotech Pty Ltd. 14W LED Downlight

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Transcription:

4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou, date of issue: 2015-07-27 Author Harry Deng By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan Author : Harry Deng Reviewed : Tim Yan Pages : 27 pages Annex : NIL DEKRA Testing and Certification (Shanghai) Ltd., Guangzhou Branch Building A3, No.3 Qiyun Road, Science City, Guangzhou Hi-tech Industrial Development Zone, Guangzhou 510663, P.R. China Tel +86 20 6661 2000 Fax +86 20 6661 2001 www.dekra-certification.com

- Page 2 of 27-4322705.50 CONTENTS page 1 Conclusion... 3 1.1 Model description... 4 1.2 Environment... 5 1.3 Classification... 5 2 Summary... 6 2.1 Applied standards... 6 2.2 Overview of results... 6 3 General Information... 7 3.1 Product Information... 7 3.2 Customer Information... 7 3.3 Test data... 8 3.4 Environmental conditions... 8 4 Emission test results... 9 4.1 Mains conducted disturbance voltage... 9 4.2 Radiated EM Field emission... 12 4.3 Harmonic currents... 15 4.4 Voltage fluctuations (Flicker)... 16 5 Immunity Test Results... 17 5.1 Electrostatic discharge immunity... 17 5.2 Radiated EM field immunity... 18 5.3 Electrical Fast Transient immunity... 19 5.4 Surge transient immunity... 20 5.5 RF Conducted immunity... 21 5.6 Power supply interruptions and dips... 22 6 Identification of the equipment under test... 23 7 Product Internal View... 25

- Page 3 of 27-4322705.50 1 CONCLUSION The equipment under test (EUT) does meet the essential requirements of the EMC Directive 2004/108/EC. The test results in this report belong to model PM1WU2-GR, and the results are also representative for other models. The conclusion and results stated in this test report are based on a non-recurrent examination of sample(s) provided by the applicant.

- Page 4 of 27-4322705.50 1.1 Model description The apparatus as supplied for the test is plug-in adaptor, model PM1WU2-GR intended for residential use, the product contains electronic control circuit and with earth connection. Base on client s declaration, all models are with similar electronic circuitry but with different type of plug. Models PM1WU2-IT, PM1WU2-GR, PM1WU2-SP, PM1WBU2-RS, PM1WU2-RS, PM1WU2-UK, PM1WU2-FR are with USB output port and the other models without. Hence, model PM1WU2-GR was chosen for full test, and the corresponding data are representative of the other models as well. Figure 1 model PM1WU2-GR The Operating Modes as stated in the User Manual are on mode and off mode.

- Page 5 of 27-4322705.50 1.2 Environment The requirements and standards apply to equipment intended for use in: Residential (domestic) environment Commercial and light-industrial environment Industrial environment Medical environment 1.3 Classification For the equipment under test the following classification is applicable. EN 55022 Class A EN 55022 Class B All ITE equipment that satisfies Class A limits but not Class B limits. Such equipment should not be restricted in its sale but the following warning shall be included in the instruction for use. Warning - This is a class A product. In a domestic environment this product may cause interference in which case the user may be required to take adequate measures. Equipment intended primarily for use in the domestic environment and may include portable equipment, telecom terminal equipment powered by a telecom network and personal computers and auxiliary connected equipment.

- Page 6 of 27-4322705.50 2 SUMMARY This chapter presents an overview of standards and results. Refer to the next chapters for details of measured test results and applied test levels. 2.1 Applied standards Standard Year Title EN 55022 2010 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement EN 55024 2010 Information technology equipment - Immunity characteristics - Limits and methods of measurement EN 61000-3-2 2014 Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current 16 A per phase) EN 61000-3-3 2013 Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current 16 A per phase and not subject to conditional connection 2.2 Overview of results Emission tests Mains conducted disturbance voltage Radiated Emission Harmonic current emission Limitation of voltage fluctuations (flicker) Result Immunity tests Electrostatic Discharges (ESD) Radiated EM Field Electrical fast transient (EFT) / Burst transients Surge transients Conducted RF disturbances Power supply voltage interruptions & dips Result

- Page 7 of 27-4322705.50 3 GENERAL INFORMATION 3.1 Product Information Equipment under test Trade mark Tested Type Represented type(s) Input Output The highest frequency of the internal sources Plug-in adaptor APC by Schneider Electric PM1WU2-GR PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-SP, PM1WBU2-RS, PM1WU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR 250 Vac, 50 Hz, PM1W-IT, PM1WU2-IT: Max. 10A; PM1W-UK, PM1WU2-UK: Max. 13A; The other models: Max. 16A 5 Vdc, 2,4 A (PM1WU2-IT, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1WU2-UK, PM1WU2-FR) Less than 108 MHz 3.2 Customer Information Applicant American Power Conversion Holdings Inc. Contact person Mr. Ken Hsieh Telephone +886-2-8313-1368 Telefax +886-2-8913-1357 Address 3F, No. 205, sec. 3, Beixin Rd., Xindian Dist., New Taipei City, Taiwan Manufacturer/Factory Dongguan Quan Sheng Electric Co., Ltd. Contact person Mr Daniel Yeh Telephone +86 769 85825371 Telefax +86 769 85825370 Address Ju-Tang 2 nd Industrial Park, 523963 Dongguan, Guangdong, China

- Page 8 of 27-4322705.50 3.3 Test data Location Address Location Address DEKRA Testing and Certification (Shanghai) Ltd. Guangzhou Branch Building A3, No.3 Qiyun Road, Science City, Guangzhou Hi-Tech Industrial Development Zone, Guangzhou, P.R. China Guangzhou Electrical Safety Testing Institute (CEST) No.6, Haichengdong Street, Xingangdong Road, Haizhu District, Guangzhou, 510330, P. R. China Date 2015-05-13 to 2015-07-02 Supervised by Harry Deng 3.4 Environmental conditions Tests have been performed in a controlled laboratory environment, where the environmental conditions are maintained within the applicable ranges. Ambient temperature 15 C 35 C Relative Humidity air 30% - 60%

- Page 9 of 27-4322705.50 4 EMISSION TEST RESULTS 4.1 Mains conducted disturbance voltage Standard EN 55022 / Class B Frequency [MHz] Limits QP [db( V)] AV [db( V)] 0,15 0,50 66 56 *) 56 46 *) 0,50 5 56 46 5 30 60 50 *) Limits decreasing linearly with the logarithm of the frequency Port Test method Worst Mode AC mains LISN Max. load

- Page 10 of 27-4322705.50 Results Live Att 10 db AUTO RBW 9 khz MT 1 s PREAMP ON dbµv 90 1 MHz 10 MHz 80 1 PK MAXH 70 2 AV MAXH 22CEBQ 60 22CEBA 50 TDS 40 30 6DB DC 20 10 0-10 150 khz 30 MHz EDIT PEAK LIST (Final Measurement Results) Trace1: 22CEBQ Trace2: 22CEBA Trace3: --- Date: 8.JUN.2015 10:05:57 TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 2 Average 722 khz 37.58-8.41 2 Average 1.382 MHz 35.73-10.26 2 Average 1.986 MHz 35.59-10.40 2 Average 24.586 MHz 36.96-13.03 2 Average 778 khz 32.16-13.83 2 Average 2.766 MHz 30.69-15.30 2 Average 2.762 MHz 30.52-15.47 2 Average 1.086 MHz 30.44-15.55 2 Average 150 khz 40.08-15.91 1 Quasi Peak 154 khz 49.86-15.91 1 Quasi Peak 1.982 MHz 39.66-16.33 No other significant emissions were measured at the frequency range of interest employing 1 Quasi Peak 24.654 MHz 43.48-16.51 both the QP and AV detectors. 1 Quasi Peak 726 khz 38.85-17.14 1 Quasi Peak 1.598 MHz 38.15-17.85 2 Average 22.542 MHz 31.77-18.22 1 Quasi Peak 222 khz 44.27-18.47 2 Average 362 khz 29.82-18.86 2 Average 434 khz 28.25-18.92 1 Quasi Peak 950 khz 36.67-19.32 1 Quasi Peak 294 khz 40.73-19.67

- Page 11 of 27-4322705.50 Natural Att 10 db AUTO RBW 9 khz MT 1 s PREAMP ON dbµv 90 1 MHz 10 MHz 80 1 PK MAXH 70 2 AV MAXH 22CEBQ 60 22CEBA 50 TDS 40 30 6DB DC 20 10 0-10 150 khz 30 MHz Trace1: Trace2: EDIT PEAK LIST (Final Measurement Results) 22CEBQ 22CEBA Trace3: Date: 8.JUN.2015 --- 10:01:41 TRACE FREQUENCY LEVEL dbµv DELTA LIMIT db 2 Average 366 khz 38.43-10.16 2 Average 778 khz 35.77-10.22 2 Average 1.97 MHz 35.50-10.49 2 Average 1.598 MHz 34.67-11.33 1 Quasi Peak 154 khz 54.15-11.62 2 Average 1.086 MHz 34.18-11.82 2 Average 294 khz 37.83-12.57 2 Average 25.038 MHz 37.35-12.64 2 Average 434 khz 34.33-12.84 2 Average 150 khz 42.97-13.02 2 Average 226 khz 38.72-13.87 No other significant emissions were measured at the frequency range of interest employing 2 Average 666 khz 32.11-13.88 both the QP and AV detectors. 1 Quasi Peak 226 khz 48.57-14.02 1 Quasi Peak 366 khz 44.55-14.04 1 Quasi Peak 294 khz 46.34-14.06 See chapter 6 for a photo of the test setup. Conclusion: 2 Average 3.558 MHz 31.42-14.57 2 Average 2.17 MHz 30.34-15.65 1 Quasi Peak 1.97 MHz 39.87-16.12 1 Quasi Peak 24.786 MHz 43.11-16.88 2 Average 23.006 MHz 31.81-18.18 Date: 8.JUN.2015 10:01:34

- Page 12 of 27-4322705.50 4.2 Radiated EM Field emission Standard Measuring distance EN 55022 / Class B 3 meters Frequency [MHz] Limits - QP [db( V/m)] 30 230 40 230 1000 47 ITU frequency bands as stated in EN 55011 are excluded from the mentioned limits. Port Set-up Worst Mode Enclosure with cabling Tab-top, 3 meter chamber Max. load

- Page 13 of 27-4322705.50 Results Horizontal Att 10 db RBW 120 khz MT 1 s PREAMP ON dbµv /m 70 100 MHz 1 GHz 1 PK MAXH 60 50 TDS 55022B 40 30 6DB DC 20 10 0 30 MHz 1 GHz EDIT PEAK LIST (Final Measurement Results) Trace1: 55022B Trace2: --- Trace3: Date: 8.JUN.2015 --- 23:35:42 TRACE FREQUENCY LEVEL dbµv/m DELTA LIMIT db 1 Quasi Peak 32.04 MHz 28.10-11.89 1 Quasi Peak 87.28 MHz 31.67-8.32 1 Quasi Peak 194.68 MHz 32.80-7.19 No other significant emissions were measured at the frequency range of interest employing the QP detectors.

- Page 14 of 27-4322705.50 Vertical Att 10 db RBW 120 khz MT 1 s PREAMP ON dbµv /m 70 100 MHz 1 GHz 1 PK MAXH 60 50 TDS 55022B 40 30 6DB DC 20 10 0 30 MHz 1 GHz EDIT PEAK LIST (Final Measurement Results) Trace1: 55022B Trace2: --- Trace3: Date: 8.JUN.2015 --- 23:30:43 TRACE FREQUENCY LEVEL dbµv/m DELTA LIMIT db 1 Quasi Peak 36.08 MHz 27.20-12.80 1 Quasi Peak 86.56 MHz 31.53-8.46 1 Quasi Peak 156.28 MHz 25.95-14.04 No other significant emissions were measured at the frequency range of interest employing the QP detectors. See chapter 6 for a photo of the test setup. Conclusion: Date: 8.JUN.2015 23:30:35

- Page 15 of 27-4322705.50 4.3 Harmonic currents Standard EN 61000-3-2 Port AC Mains supply Mode On mode Class A All apparatus not classified as Class B, C or D Class B Portable tools Class C Lighting equipment Class D Personal computers, television receivers Results and limits This product is not defined as lighting equipment, and rated power is less than 75W, therefore, no limit applies according to EN 61000-3-2. Conclusion:

- Page 16 of 27-4322705.50 4.4 Voltage fluctuations (Flicker) Standard EN 61000-3-3 Port AC Mains supply Voltage 230 Vac Mode On mode Equipment intended to be connected to 230/400 V, 50 Hz supply systems may not produce voltage fluctuations in the supply systems due to variation of the input current above the limits as stated below. Results Tests are not necessary because the EUT is unlikely to produce significant voltage fluctuations or flicker (clause 6.1) Conclusion:

- Page 17 of 27-4322705.50 5 IMMUNITY TEST RESULTS 5.1 Electrostatic discharge immunity Electrostatic discharges (ESD) are the result of persons or objects that accumulate static electricity due to for instance walking on synthetic carpets. The ESD can influence the operation of equipment or damage its electronics, either by a direct discharge or indirectly by coupling or radiation. Both effects are simulated during the tests. Requirements Standard EN 55024 Basic standard EN 61000-4-2 Port Enclosure Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed. Air discharges 8 kv Contact discharges 4 kv Mode On mode Performed tests Air discharges 4 kv 8 kv 15 kv xx kv Contact discharges 2 kv 4 kv 8 kv xx kv Via coupling planes Horizontal Vertical Polarity Positive Negative Set-up Table-top Floor standing Ambient temperature 20 C Relative Humidity air 50 % Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance or loss of data was observed. Conclusion:

- Page 18 of 27-4322705.50 5.2 Radiated EM field immunity During the test it is verified if the equipment under test has sufficient immunity against radiated electromagnetic fields. Walkie-talkies, radio transmitters, television transmitters, and telecommunication equipment including cellular telephones and other emitting devices, like industrial electromagnetic sources can generate these fields. Requirements Standard EN 55024 Basic standard EN 61000-4-3 Port Enclosure Performance criterion A; Operation as intended Frequency range 80-1000 MHz Modulation 1 khz 80% AM Field strength 3 V/m Performed tests Frequency range Tested Field strength Dwell time Test set-up Mode 80-1000 MHz 3 V/m 1 second Full Anechoic Chamber On mode Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance or loss of data was observed. Conclusion:

- Page 19 of 27-4322705.50 5.3 Electrical Fast Transient immunity The EFT immunity test simulates disturbances by bursts of very short transients caused for example by switching off loads such as an AC motor or bouncing relay contacts. The transients are likely to disturb electronics but less likely to cause damage. Requirements Standard EN 55024 Basic standard EN 61000-4-4 Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed. Pulse characteristics 5/50 ns Peak Voltage; Port 1 kv; AC input power port Repetition frequency 5 khz 2,5 khz Performed tests Tested Voltage; Port 1 kv; AC input power port Mode On mode Injection method CDN Capacitive clamp Polarity Positive Negative Set-up Table-top Floor standing Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance or loss of data was observed. Conclusion:

- Page 20 of 27-4322705.50 5.4 Surge transient immunity The surge transient immunity test simulates the surges that are caused by overvoltages due to indirect (induced) lightning transients. The pulse is a slow transient with high-energy contents and due to its long duration may cause damage to an unprotected EUT. Requirements Standard EN 55024 Basic standard EN 61000-4-5 Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed. Pulse characteristics 1,2/50 µs Peak Voltage; Port 1 kv; AC input power port (line to line) 2 kv; AC input power port (line to earth) Performed tests Tested Voltage; Port 1 kv; AC input power port (line to line) 2 kv; AC input power port (line to earth) Mode On mode Polarity Positive Negative Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance or loss of data was observed. Conclusion:

- Page 21 of 27-4322705.50 5.5 RF Conducted immunity During this test the immunity of the equipment for induced or conducted electromagnetic fields is checked. Fields generated by radio and other transmitters cause RF voltages in long cables like the mains network. This test reproduces these induced disturbing voltages by injecting them to the EUT via the cabling. Requirements Standard EN 55024 Basic standard EN 61000-4-6 Performance criterion A; Operation as intended Frequency range 0,15 80 MHz Modulation 1 khz 80% AM Test level; Port 3 V; AC input output power port Performed tests Tested level; Port 3 V; AC input power port Mode On mode Frequency range 0,15 80 MHz Dwell time 3 seconds Injection method CDN-M3 EM clamp Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance or loss of data was observed. Conclusion:

- Page 22 of 27-4322705.50 5.6 Power supply interruptions and dips Requirements Basic standard EN 61000-4-11: Performance criterion B; During the test degradation is allowed. No change of operating state or stored data is allowed. C; Temporary, self-recoverable loss of function is allowed. Standard EN 55024 C U NOM 30% (25 periods) AC input power port B U NOM 100% (0,5 period) C U NOM 100% (250 periods) Performed tests Tested voltage Mode AC input power port AC input power port, 230 Vac On mode C U NOM 30% (25 periods) B U NOM 100% (0,5 period) C U NOM 100% (250 periods) Observations During the test no loss of performance was observed. After the test the EUT functioned as intended. No unacceptable loss of performance or loss of data was observed. Conclusion:

- Page 23 of 27-4322705.50 6 IDENTIFICATION OF THE EQUIPMENT UNDER TEST The photograph shows the tested device. Figure 2 conducted emission test setup

- Page 24 of 27-4322705.50 Figure 3 radiated emission test setup

- Page 25 of 27-4322705.50 7 PRODUCT INTERNAL VIEW Wiring PCB

- Page 26 of 27-4322705.50 PCB PCB

- Page 27 of 27-4322705.50 PCB