Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

Similar documents
Integre Pro Scan combines pattern scanning and multi-color photocoagulation in our unique all-in-one laser/slit lamp design.

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500 US EDITION

The pattern scanning multi-color photocoagulator that puts you in control

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

VISULAS Trion. Treatment flexibility to the power of three. Multicolor Photocoagulation Laser

CO 2 Laser. AcuPulse. with SurgiTouch. Automation System. An Evolution in Automated Laser Surgery. Surgical: AcuPulse CO 2 Laser

Green Scan Laser PhotocoagulatorGYC-500 Vixi. Green Laser PhotocoagulatorGYC-500

introducing the M22 success made simple

KTP LASER. Photocoagulation System

Yellow Scan Laser Photocoagulator YLC-500 Vixi. Yellow Laser Photocoagulator YLC-500

577 nm: The Preferred Wavelength

The Fastest Photocoagulator.

Better diagnosis and treatment all-in-one.

Navigated Laser Therapy. A New Era in Retinal Disease Management

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

SLIT LAMP BQ 900 Sophisticated microscopy

Wide Angle Ophthalmoscope Instructions

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

Confocal NEXIV VMZ-K Series. CNC Video Measuring System CONFOCAL NEXIV. VMZ-K Series

CONTACT LENSES Discover a different world

Super High Vertical Resolution Non-Contact 3D Surface Profiler BW-S500/BW-D500 Series

Machine Vision Lyte-MV 2

Instruments Commonly Used For Examination of the Eye

Examination light with LED technology CHROMOPHARE F 300

The First True Color Confocal Scanner on the Market

Our vision is foresight

Coherent Laser Measurement and Control Beam Diagnostics

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

The First True Color Confocal Scanner

Xenon-Diamond 2.9/106 With beam splitter

L100 The ultimate CMM laser scanner combining productivity and accuracy NIKON METROLOGY I VISION BEYOND PRECISION

DORADOnova MR3T MOVING LASER SYSTEM FOR PATIENT ALIGNMENT IN RT

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

OCULUS Keratograph 4. Topographer. We focus on progress

The First True-Color Wide-Field Confocal Scanner

Headline. SL 130 Slit Lamp. Subline. Maximum quality for optimum performance

Impressive Wide Field Image Quality with Small Pupil Size

SPECTRALIS Training Guide

Acculase Green PWM. Direct Drive Green Laser Diode Module

Optical Components - Scanning Lenses

Optical Coherence Tomography Retina Scan Duo

OCULUS Pentacam AXL Always an Axial Length Ahead

Xenon-Zirconia 3.3/92

CNC Video Measuring System NEXIV VMZ-K series. CNC Video Measuring System. Confocal Model

MEL 80 Excimer Laser. When you want to see better performance

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

DORADOnova MOVING LASER SYSTEM FOR PATIENT ALIGNMENT IN RT

ioct Discover the next generation of efficiency enhancement

Fast Laser Raman Microscope RAMAN

Optical Information. The LDM145 laser diode modules are available with the following lens types.

FireFly Green. It is a self-contained laser that offers the user increased stability over a wide operating temperature and with a faster warm up time.

Litho DK30. Taking care of people, our masterpieces. State-of-the-art Desktop 30 W Holmium:YAG Laser. Surgery

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Application Note (A11)

Premier & Acculase Modulatable Laser Diode Modules

Instructions for the Experiment

Will contain image distance after raytrace Will contain image height after raytrace

flexible lighting technology

DIGITAL IMAGING NON-MYDRIATIC FUNDUS CAMERA NM-1000

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

BETA Otoscopes & Ophthalmoscopes DIAGNOSTIC INSTRUMENTS

SURGICAL LIGHT TECHNOLOGY BEHIND THE LIGHT

Wuxi OptonTech Ltd. Structured light DOEs without requiring collimation: For surface-emitting lasers (e.g. VCSELs)

MR3T LASER SYSTEMS IN RT ESSENTIAL FOR PRECISE PATIENT ALIGNMENT

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

Wafer Loaders for IC Inspection Microscopes NWL200 Series. Wafer Loaders for IC Inspection Microscopes

How-to guide. Working with a pre-assembled THz system

SPECIFICATIONS. Table 2 - Specifications for rack mounted electronics with user controller. Document Number Rev 1

Beamscope-P8 Wavelength Range. Resolution ¼ - 45 ¼ - 45

Welcome to a radically different approach to cancer treatment.

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

MEASUREMENT APPLICATION GUIDE OUTER/INNER

OPERATING MANUAL. 100 MHz CENTER FREQUENCY OFF AXIS ACOUSTO-OPTIC BEAM DEFLECTOR MODEL NUMBER: DEG-.51 DOCUMENT NUMBER: 51A12229A

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

HEINE QUALITY. :- HEINE Hand-held Ophthalmic Instruments

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Sets distance refraction. Moves camera forward / backward. Moves camera up / down. Moves camera left / right. Starts image acquisition (HRT 3 only)

Brilliant Light YLED-1F. For Diagnosis and Surgery

OPERATING MANUAL. ACOUSTO OPTIC MODULATOR MODEL NUMBER: X-LTD X= 1, 2, or 3 mm DOCUMENT NUMBER: 51A00620D

Guide to SPEX Optical Spectrometer

IMAGING MODULES IM 900 & IM 600 From the leader in slit lamp imaging

OPERATING MANUAL. ACOUSTO OPTIC MODULATOR MODEL NUMBER: X-1.06-LTD X= 1, 2, or 3 mm DOCUMENT NUMBER: 51A14950A

Auto Ref/ Keratometer / Auto Refractometer ARK-1 / AR-1

Light has some interesting properties, many of which are used in medicine:

Exercise 8: Interference and diffraction

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

ETC ORDERING INFORMATION GENERAL INFORMATION. Selador Pearl CE. Accessories

RIEGL VQ -780i NEW. Airborne Laser Scanning. Waveform Processing Airborne Laser Scanner for Ultra Wide Area Mapping and High Productivity.

used to diagnose and treat medical conditions. State the precautions necessary when X ray machines and CT scanners are used.

Beam Profiling. Introduction. What is Beam Profiling? by Michael Scaggs. Haas Laser Technologies, Inc.

MINISILK FT MINISILK FT MEDICINE AND AESTHETICS. DEKA Pulsed Light: Light, Compact, Extremely Versatile

(a) Imaging Veins Superficial veins that are less than 3 mm deep can sometimes be seen as blue-green (often raised) areas of the skin.

Think of LASER as a tool

Tailored bar concepts for 10 mm-mrad fiber coupled modules scalable to kw-class direct diode lasers

Varilite Datasheet. Thread Mountable Laser Diode Module

Macro Varon 4.5/85. Key features. Applications. Web and surface inspections

3D METAL PRINTING OF TOMORROW. Available Today.

LC15Dx Laser scanner High accuracy with high resolution. nikon metrology I vision beyond precision

NEW. Airborne Laser Scanning. Waveform Processing Airborne Laser Scanner for Wide Area Mapping and High Productivity. visit our website

Performance Meets Simplicity

Transcription:

Lumenis Array LaserLink Pattern Scanning Laser Technology RETINA

Array LaserLink Pattern Scanning Laser Technology Pattern Scanning Laser can reduce photocoagulation treatment time by as much as 60% Pattern scanning laser provides enhanced uniformity of laser application, shorter treatment time, and less discomfort to the patient. The Array LaserLink offers pattern scanning capabilities compatible with Lumenis laser systems and popular slit lamps, versatility of wavelengths, various adjustable patterns and a range of laser spot sizes. Compatibility Versatility Sensibility Links with Lumenis lasers: Vision One Novus Spectra And attaches to most popular slit lamps: Lumenis 980 Lumenis 990* Zeiss SL130 Zeiss 30SL Haag Streit 900 BQ* With Lumenis multi-wavelength technology, Array delivers any of the following wavelengths: Green: 532 nm Yellow: 577 nm Red: 659 nm Array treatment options: Single spot Pulse mode Various patterns Array offers a range of laser spot sizes from 50µm to 1000µm in single spot mode, 100µm to 500µm in pattern scanning mode. Intuitive touchscreen presents logical workflow Custom Touchpad is easily moved for use with right or left hand and provides Eyes Forward Control Heads Up Display, seen as text on the retina, shows confirmation of important parameter changes Frame mode displays a precise outline of the area in which the pattern will be administered. Titrate mode is used to establish appropriate pattern laser parameters with a single spot Contact lens menu lists commonly used lenses for calculation of laser spot size on the retina Spot size on retina tells doctor actual parameter of treatment *May have later release date

Array LaserLink Eyes Forward Control Keeps the Target in View Maintain focus on the patient Eyes Forward Control Is afforded by the ability to control and verify treatment parameters without moving from the slit lamp oculars or losing sight of the target retina. Unique Array Touchpad Uses just the simple stroke of a finger Is movable for left or right hand use Adjusts laser parameters and micromanipulation Heads Up Display Confirms changes to treatment parameters Shows text on the retina Modified parameters are projected as text onto the retina Intuitive Touchscreen On a fully adjustable monitor Is easily reached and visualized for treatment set up and procedure

Customize treatment to meet the needs of the patient and physician Continuously Variable Spot Size Single spot from 50µm to 1000µm Pattern mode from 100µm to 500µm For customized treatment for the particular disease state and tissue response Variety of Adjustable Patterns Includes single spot and 6 shapes Square: 2 to 5 spots per side Line: 2 spots in one line up to 4 spots in each of 5 lines Triangle: 6 or 15 spots Circle: Single adjustable ring Half and quarter circle: 1 or 3 adjustable rings Up to 5 Preset Protocols Retain favorite settings in memory Include settings such as fundus lens selection, laser power, spot size, spot spacing, number of spots and duration Selectable Spot Spacing From 0 to 3 times the spot diameter within a circle From 0.25 to 3 times the spot diameter in other patterns New Generation ClearView Filters Utilize photopic balanced coating to eliminate color distortion Optimize white light transmission or brightness of the physician s view Lumenis Patented SureSpot Optics Ensure that the focal point of the laser beam is maintained on the retina Minimize power density on the cornea and lens for increased safety

With unique Eyes Forward Control the physician does not lose sight of the patient s retina. Touchpad The Array Touchpad allows adjustment to laser power, pattern, number of spots, spacing between spots, rotation of pattern and micromanipulation of the aiming and laser beam - all with just the stroke of a finger. Heads Up Display Heads Up Display shows changes to pattern spot parameters as text on the retina, seen through the oculars of the slit lamp. 110 mw Touchscreen Intuitive Touchscreen duplicates the functions of the laser s remote control. The fully adjustable monitor is locatable on either side of the slit lamp. It is easily reached and visualized for treatment set up and during the procedure.

Lumenis Array LaserLink Specifications Patterns Spot Size Single spot, square, line, triangle, circle, half circle, quarter circle Single spot: 50,100, 125, 150, 175, 200, 250, 300, 400, 500,1000µm 3-ring half circle or 3-ring quarter circle: 100µm and 200µm Other Patterns: 100, 125, 150, 175, 200, 250, 300, 400, 500μm. Spot Spacing Single-ring circle: 0.0, 0.25, 0.50, 0.75, 1.00, 1.50, 2.00, 2.50, 3.00x Other patterns: 0.25, 0.50, 0.75, 1.00, 1.50, 2.00, 2.50, 3.00x Spot Duration Power Compatible lasers Vision One Novus Spectra / Spectra DP Compatible slit lamps Off Axis Illumination Slit Lamps On Axis Illumination Slit Lamps* Electrical requirements General specifications Weight Equipment classification *May have later release date 10, 20, 30, 40, 50ms for patterns; 10-3000ms for single spot 532nm: 50-2000mW 577nm: 50-1500mW 659nm: 50-800mW 532 nm (green); 577 nm (yellow); 659 nm (red) 532 nm (green) Lumenis 980 Zeiss 30SL Zeiss SL130 Lumenis 990 Haag Streit 900BQ 100-120 VAC, 50/60 Hz, 6.30 A 220-240 VAC, 50/60 Hz, 3.15 A Console: 3.5 kg Array LaserLink Module: 5 kg Class I Lumenis Certified Service Certified Engineers & Parts > Reliable Performance > Superior Value > Satisfied Customers USA Toll-free 1-877-LUMENIS (1-877-586-3647) For outside the USA, visit www.lumenis.com, click Service & Support, contact your local Lumenis representative Lumenis Global Sales Offices Lumenis Inc. San Jose, CA, USA Tel +1 408 764 3000 Fax +1 408 764 3999 Lumenis Japan Co. Ltd. Tokyo, Japan Tel +81 3 6743 8300 Fax +81 3 6743 8301 Lumenis (CHINA) Inc. Beijing, China Tel +86 10 5737 6677 Fax +86 10 5737 6767 Lumenis (HK) Ltd. Hong Kong Tel +852 2174 2800 Fax +852 2722 5151 Lumenis India Haryana, India Tel +91 124 4210795 Lumenis (UK) Ltd. Elstree Hertfordshire, UK Tel +44 20 8736 4110 Fax +44 20 8736 4119 Lumenis (GERMANY) GmbH Dreieich-Dreieichenhain, Germany Tel +49 6103 8335 0 Fax +49 6103 8335 300 Lumenis (ITALY) Srl. Rome, Italy Tel +39 06 90 75 230 Fax +39 06 90 75 269 For an authorized Lumenis representative in your country, please visit: www.lumenis.com Or email us at: information@lumenis.com ISO 13485 CERTIFIED 2010, the Lumenis group of companies. All rights reserved. Lumenis, its logo, Vision One are trademarks or registered trademarks of the Lumenis Group of companies. Product specifications are subject to change without notice. PB-1002837_A