Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Similar documents
The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

Current Module, 3-channel, MDRC SM/S , GH Q R0111

For controlling 4 independent shutter or sunblind drives via ABB i-bus including the functions Up/Down, Step/Stop.

Shutter Actuator with Manual Operation, 4-fold, 230 V AC, MDRC JA/S M, GH Q R0111. ABB i-bus EIB / KNX

Product Manual. ABB i-bus EIB / KNX. Universal Interface US/U Intelligent Installation Systems

The room thermostat application module with 2-fold switch sensor is placed on a flush-mounted bus coupler.

Binary Inputs. Ref.-No. KNX universal binary input, 8-gang. ETS-product family: Series embodiment (SE-) device (2 units) Ref.-No.

Width (W): 44 mm. bus connecting and branching terminal External supply --- Inputs: Number: up to 2 (depending on parameterization: channel 1 to 2)

Installer manual inputs/outputs interface for led KNX

Room thermostat solo, FM Type: 6124-xx

EIB/KNX Switch Actuators. User manual

K-BUS Switch Actuator

instabus EIB product documentation

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

16-Channel Yearly Time Switch TR 648 S DCF

animeo KNX/EIB 4 AC Motor Controller WM/DRM V AC

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

ABB i-bus KNX Meter Interface Module, MDRC ZS/S 1.1. Product Manual. Intelligent Installations Systems ABB

1. Use of the application program

animeo KNX/EIB 4 DC/E Motor Controller WM V AC Installation manual

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

ABB i-bus KNX Valve Drive Actuator VAA/S x Product Manual

Technical Manual MDT LED-Indicator

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

ABB i-bus. KNX Weather Station WS/S Product Manual

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

Rev Product Manual ABB i-bus KNX. Heating actuator 1gang with 6164/11 U-500. Power and productivity for a better world TM

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

Instruction manual. art Installation manual

CU-DIN DIM 6-CH 0 10V KNX

Product and Applications Description

KNX manual 1-channel flush-mounted switch actuator SU 1

Technical manual GS 4x.00 knx application description air quality sensor

KNX ON/OFF controller 4 contacts 16A

SeeTool - Solutions for KNX

Use of the application program. Functional description. GAMMA instabus Application program description. October 2007

Use of the application program. Functional description. GAMMA instabus Application program description. May A8 Venetian blind actuator

HDL KNX / EIB BUS. Dimmer Actuator. 1/43. Light Technology Nederland ditributor of HDL

Fan Coil Actuator FCA 2

USER MANUAL CU-DIN DIM 4-CH 1.5A KNX EC MA

Product Manual. ABB i-bus KNX Light Controller with Sensor LR/S with LF/U. Intelligent Installation Systems ABB

Application Description

KNX Room temperature controller

Use of the application program. Contents. instabus EIB Application program description. September S2 Room temperature controller

theben 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB

animeo KNX 4 DCE Motor Controller WM/DRM V AC Instructions

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2

INSTABUS RADIO GATEWAY

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

Unidirectional Gateway EnOcean - KNX/BUS

ABB i-bus KNX DALI Light Controller DLR/S M Product Manual

Electrical devices may only be mounted and connected by electrically skilled persons.

MDT Switch Actuator/FanCoil

KNX weather station basic V2

PRODUCT MANUAL. ABB i-bus KNX VC/S 4.x.1 Valve Drive Controller

Electrical devices may only be mounted and connected by electrically skilled persons.

Thorsten Reibel, Training & Qualification Global Application and Solution Team

animeo KNX 4 DC 2 A Motor Controller WM 24 V DC Installation manual

The specifications are classified as follows: Characterization, type and order-number. Mode of functioning. Technical data.

Radio-control universal dimmer (built-in type) Installation Instructions

Meteodata 140 S weather station

Technical Manual MDT Room Temperature Controller

gesis EIB V Manual Installation system for European Installation Bus Products and Objects description

Instabus Radio Control Converter Installation Instructions

0-10V to DALI Converter

KNX ENO 620/622 (32-channel AP)

application software

Functions module / Gateways Application Description Product Page KNX-GW-DMX-xxx DMX Gateway. KNX-GW-DMX Product Group 1

KNX TH65-AP. Thermo-Hygrometer. Installation and Adjustment. Item number 70184

KNX Powerline PL 110. KNX Association

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Electrical devices may only be mounted and connected by electrically skilled persons.

Intelligent Installation Systems. ABB i-bus KNX Room Thermostat Fan Coil with Display 6138/11-xx-500 Product Manual

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Sentido KNX Manual. Sentido KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium

STC-KNX (32-channel AP)

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

KNX ENO 634 (32-channel AP)

Smart Dupline Wireless dimmer with energy reading Type SHJWD200WExxx

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

Absolute Encoders Singleturn

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

Sauter Components

User Manual 3X300 DIMMER MODULE DM03B02KNX

83 Series - Modular timers 16 A. Features

ABB i-bus EIB. Shutter Control Unit

Absolute Encoders Multiturn

Air Quality Sensor KNX AQS

Application Programs Descriptions

ABB i-bus KNX Energy Actuator SE/S Product Manual

KNX presence detectors for ceiling flush mount EK-DD2-TP, EK-DE2-TP

Multi-voltage Multi-function. Wiring diagram (without control signal)

Transcription:

, GH Q605 0062 R0001 The 2-fold week time switch is a DIN rail mounted device with a width of two modules for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal. The cover in front of the keypad and the display can be sealed. The time switch can send time-dependent switching or 1 byte value telegrams to EIB actuators. Using the keypad on the front of the housing, 36 time periods can be set for both channels with free weekday block formation. Technical data Power supply EIB 24 V DC, via the bus line Display and operating elements Red LED and push button for assigning the physical address 7 push buttons for setting the time and manual control LCD for displaying the time and switching state 9 Connections EIB via bus connecting terminal 9 Type of protection IP 20, EN 60 529 Ambient temperature range Operation - 5 C 45 C Storage - 25 C 55 C Transport - 25 C 70 C Design Modular installation device, prom Housing, colour Plastic housing, grey Mounting on 35 mm mounting rail, DIN EN 50022 Dimensions 86 x 36 x 64 mm (H x W x D) Mounting depth/width Weight Certification CE norm 36 mm / 2 modules at 18 mm 0.17 kg EIB-certified in accordance with the EMC guideline and the low voltage guideline Special features Memory locations 36 Time base Quarz Accuracy < 1 s per day Min. switching interval 1 minute Power reserve 6 years Page 1 of 8

, GH Q605 0062 R0001 Application programs Number of Max. number of Max. number of communication objects group addresses associations Switch /4 2 6 6 Switch Value /1 4 4 4 Switch Value Priority Scene Cyclic /1 9 11 11 Wiring diagram 1 3 2 9 9 1 LCD 3 Bus connecting terminal 2 Keypad for setting the time Information Further information about the handling and operation of this device can be found in the operation instructions or in the manual that is supplied with the device. You can likewise find this information on our EIB CD-ROM. Page 2 of 8

, GH Q605 0062 R0001 Switch Default-Setting /2 Selection in ETS2 ABB Timer Clock switch Switch The time switch has two communication objects that can send switch telegrams. Whether a channel sends an On or Off telegram, is dependent on the programming of the switching times via the keypad and on the setting of the parameter Reaction if timer switches. It can be established for each of the two switching impulses and OFF, which telegram the timer sends. It is possible to assign parameters to the reaction of the time switch on bus voltage recovery. The communication object can either send its actual value or only send its value if it has changed since the bus voltage failure or it can send no telegram. If a channel is set to TOGGLE, a further parameter is displayed, where it is possible to specify the value of the object after commissioning. If the first telegram after commissioning should switch off, the object value must be set to. If the timer sends a telegram on bus voltage recovery, it takes the sending delay into consideration, that has been set using the Factor and fixed Time base parameters. 9 9 No. Type Name Function 0 1 bit Channel 1 Telegr. switch 1 1 bit Channel 2 Telegr. switch Parameters The default setting for the values is printed in bold type. Common for both channels: Factor for transmission delay 16 after bus voltage recovery Time base 130 ms Separate for both channels: Reaction if timer switches timer -> / timer OFF -> OFF timer -> OFF / timer OFF -> timer -> / timer OFF -> timer -> OFF / timer OFF -> OFF timer -> / timer OFF -> --- timer -> OFF / timer OFF -> --- timer -> --- / timer OFF -> timer -> --- / timer OFF -> OFF timer -> TOGGLE / timer OFF -> TOGGLE timer -> TOGGLE / timer OFF -> --- timer -> --- / timer OFF -> TOGGLE timer -> --- / timer OFF -> --- Behaviour on bus voltage recovery send actual value send only when status changes send no telegram Preset for commissioning OFF Page 3 of 8

, GH Q605 0062 R0001 Switch Value /7 Selection in ETS2 ABB Timer Clock switch Switch The time switch has two communication objects that can send switch telegrams. Whether a channel sends an On or Off telegram is dependent on the programming of the switching times via the keypad and on the settings in the parameters Send switch switch telegram... and Switch command. It can be established for each of the two switching impulses and OFF, which telegram the timer sends. Value With the 1 byte objects the timer can send e.g. brightness values between 0 (= off) and 255 (= maximum brightness) to dimming actuators. The setting of parameters is carried out in the same way as for switching objects using the two parameters Send value and Value (0 255). It is possible to assign parameters to the reaction of the time switch on bus voltage recovery. The communication object can either send its actual value or only send its value if it has changed since the bus voltage failure or it can send no telegram. If the timer sends a telegram on bus voltage recovery, it takes the sending delay into consideration that has been set using the Factor and fixed Time base parameters. 9 9 No. Type Name Function 0 1 bit Channel 1 - switch Telegr. switch 1 1 bit Channel 2 - switch Telegr. switch 2 1 byte Channel 1 - value Telegr. value 3 1 byte Channel 2 - value Telegr. value Parameters The default setting for the values is printed in bold type. Common for both channels: Factor for transmission delay 16 after bus voltage recovery Time base 130 ms Separate for both channels: Switch If timer -> OFF no reaction If timer -> OFF OFF no reaction Value If timer -> send following value send no value only for sending value: value (0 255) 200 If timer -> OFF send following value send no value only for sending value: value (0 255) 50 Behaviour on bus voltage recovery send actual value send only when status changes send no telegram Page 4 of 8

, GH Q605 0062 R0001 Switch Value Priority Scene Cyclic /1 Selection in ETS2 ABB Timer Clock switch The application program has a maximum of four communication objects available for the two channels of the timer. The number of communication objects that are used by a channel is set in the parameter Channel... controls. Using the parameter Object type, it is defined for each of these communication objects, whether they are used for switching (1 bit), sending values (1 byte) or for switching with priority control (2 bit). The telegrams that are sent by the communication objects are dependent on the programming of the switching points via the keyboard and the parameter settings. Scene By combining various objects, it is possible to define scenes with different actuators. These scenes are recalled using time control according to the pa- 9 rameter settings and the programming sending behaviour. If the disable object 9 of the clock. Switch Either an On or Off telegram can be sent for both the On and Off signal of the clock. Value It is possible to set a 1 byte value between 0 and 255 for the On or Off signal of the clock. This value can then be sent on the bus. This enables dimming actuators for example to be controlled. Priority The following values can be sent for each switching signal of the clock in accordance with EIS 8: Priority (telegram value = 3) Priority OFF (telegram value = 2) Priority inactive (telegram value = 1 or 0) Primary control can thus be implemented in connection with appropriate actuators. Cyclic Using the parameter Cyclic sending, it is possible to define whether each communication object sends its telegrams at regular intervals. A common cyclic interval is specified for all the objects. It is possible to select a period between 2.5 and 60 minutes. Disable The time program of the clock can be suppressed with the communication object Channels 1+2 Telegr. disable. It can be set for each of the objects Channel... object..., whether the disable object influences the sending behaviour. If this is the case, it can further be defined when the disable object is activated whether the channel objects should send a telegram once according to the On or Off signal of the clock or send no telegram. The objects concerned then adjust the is reset, the current status of the channel objects is sent immediately on the bus. Page 5 of 8

, GH Q605 0062 R0001 Nr. Typ Objectname Funktion 0 1 bit Channel 1 - object 1 Telegr. switch 4 1 bit Channel 2 - object 1 Telegr. switch 8 1 bit Channels 1+2 Disable for Switch function Nr. Typ Objectname Funktion 0 1 bit Channel 1 - object 1 Telegr. switch 1 1 bit Channel 1 - object 2 Telegr. switch 2 1 bit Channel 1 - object 3 Telegr. switch 3 1 bit Channel 1 - object 4 Telegr. switch 4 1 bit Channel 2 - object 1 Telegr. switch 5 1 bit Channel 2 - object 2 Telegr. switch 6 1 bit Channel 2 - object 3 Telegr. switch 7 1 bit Channel 2 - object 4 Telegr. switch 8 1 bit Channels 1+2 Disable for Value function Nr. Typ Objectname Funktion 0 1 byte Channel 1 - object 1 Telegr. value 1 1 byte Channel 1 - object 2 Telegr. value 2 1 byte Channel 1 - object 3 Telegr. value 3 1 byte Channel 1 - object 4 Telegr. value 4 1 byte Channel 2 - object 1 Telegr. value 5 1 byte Channel 2 - object 2 Telegr. value 9 6 1 byte Channel 2 - object 3 Telegr. value 9 7 1 byte Channel 2 - object 4 Telegr. value 8 1 bit Channels 1+2 Disable for Priority function Nr. Typ Objectname Funktion 0 2 bit Channel 1 - object 1 Telegr. priority 1 2 bit Channel 1 - object 2 Telegr. priority 2 2 bit Channel 1 - object 3 Telegr. priority 3 2 bit Channel 1 - object 4 Telegr. priority 4 2 bit Channel 2 - object 1 Telegr. priority 5 2 bit Channel 2 - object 2 Telegr. priority 6 2 bit Channel 2 - object 3 Telegr. priority 7 2 bit Channel 2 - object 4 Telegr. priority 8 1 bit Channels 1+2 Disable Page 6 of 8

, GH Q605 0062 R0001 Parameters The default setting for the values is printed in bold type. General: Time interval for cycling sending approx. 2,5 min. / approx. 5 min. / approx. 10 min. / / approx. 60 min. How many objects shall be 1 object allowcated to channel 1 2 objects 3 objects 4 objects How many objects shall be 1 object allowcated to channel 2 2 objects 3 objects 4 objects Separate for all objects: Function send telegr. switch send telegr. value send telegr. priority only for switch function: If timer -> OFF send no telegram Telegram OFF If timer -> send no telegram Telegram OFF only for value function: If timer -> OFF send no telegram 9 Value (0 255) 50 9 If timer -> send no telegram Value (0 255) 200 only for priority function: If timer -> OFF send no telegram Priority RELEASED OFF If timer -> send no telegram Priority RELEASED OFF Cycling sending no / yes Object disable via object 8 no /yes only for yes: On disabling channel sends one times a telegram object no telegram only one times a telegram: as defined for timer -> OFF as defined for timer -> Page 7 of 8

, GH Q605 0062 R0001 9 9 Page 8 of 8