Original operating instructions Fail-safe inductive sensor GG507S

Similar documents
Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GM705S

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2018

PROXIMITY SENSOR TERMINOLOGY

Installation Instructions RF identification system Read/write head ANT430 ANT431

Proximity Sensor Terminology

Installation Instructions RF-identification system Read/write head ANT513

Original instructions INCA-1 Tina Emergency stop for enclosure installation INCA-1S Tina Safety stop for enclosure installation

Operating instructions Electronic level sensor LK / / 2008

Operating instructions Contrast sensor O5K / / 2016

Operating instructions Measured signal converter for temperature sensors. TP323x / / 2010

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Measured signal converter for temperature sensors TP / / 2010

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Operating instructions Diffuse reflection sensor with background suppression. OJ51xx laser / / 2010

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Installation instructions SmartController XL CR / / 2014

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

Operating instructions. RFID UHF reader DTE800 DTE810 DTE900 DTE910 DTE / / 2017

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2009

Tube Facing Tool.

Operating Instructions

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

Operating instructions. Electronic pressure sensor PY2068 ENGLISH

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Instruction manual for STA 1 sectional door operator

Operating instructions. Combined pressure sensor PN /00 11/03

Magnetic Inductive Flow Sensor induq

Instruction manual for STA 1 sectional door operator

Installation instructions BasicController CR0401 CR / / 2012

Operating instructions. RFID UHF antennas Low range / ultra-low range Mid range / short mid range Wide range

Miniature resistance thermometer Model TR33, thread-mounted

Technical Data. General specifications. Rated operating distance s n 3 mm

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

TECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION

PHOENIX CONTACT - 09/2009

Datasheet - PROTECT-IE-02

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Content. Monitoring relay pluggable. 1-phase current monitoring relay phase direct-current voltage monitoring relay... 5.

Operating instructions Magnetic-inductive flow meter SM6050 SM7050 SM / / 2016

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

T22. Torque transducer. Special features. Data sheet

Electronic timer CT-TGD.22

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Installation Instructions Electronic pressure sensor. PTD25-10-xxxxx PTD25-20-xxxxx

QUINT-PS/ 3AC/24DC/10

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

Installation instructions for encoders. RM3xxx RM7xxx RN3xxx RN7xxx /02 08/2015

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Product Information. RCN 2000 RCN 5000 RCN 8000 Absolute Angle Encoders for Safety-Related Applications

Capacitive sensors. Versatile, contactless, durable Edition 2012/2013

Order/Technical Support Tel: (800) / FAX: (800) /

Lexium integrated drives

Power supply CP-E 24/0.75

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Classification of Binary 24 V Interfaces - Functional Safety aspects covered by dynamic testing Edition Timing Characteristics

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Type CP-S, CP-C & CP-A Switch mode

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

QUINT-PS AC/24DC/40

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

3B SCIENTIFIC PHYSICS

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Power supply CP-D 24/1.3

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

MINI-PS AC/24DC/1.3

Ultrasonic level measuring device, non-contact

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-E 24/2.5

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Optical laser distance sensors. Dimensioned drawing

User and Safety Manual ProLine P224xx P1

Power supply CP-E 24/20.0

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

E2B PROXIMITY SENSORS

QUINT-PS-24DC/24DC/10

Operating instructions Magnetic-inductive flow meter FMM FMM FMM

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Inductive sensor slot-type SI2-K08-AP7

Power supply CP-E 24/2.5

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

QL55 Series Luminescence Sensor

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

ZITARES CC Constant current control gear, 2-channel, dimmable

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

E2Q5. Square Proximity Sensor. Long Distance Square Inductive Proximity Sensor. Ordering Information

Triple Voltage Regulator TLE 4471

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Power supply CP-D 12/2.1

Online data sheet TTK70-AXA0-K02 TTK70 LINEAR ENCODERS

Laser contrast scanner. Dimensioned drawing

QUINT-PS/ 3AC/24DC/40

New Products Catalogue 2009 Safety Relays ESR5

Transcription:

Original operating instructions Fail-safe inductive sensor GG507S 80236827 / 00 09 / 2016

Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warning signs used...3 2 Safety instructions...4 2.1 Safety-related requirements regarding the application...4 3 Items supplied...5 4 Functions and features...5 5 Function...6 5.1 Enable zone...6 5.2 Protection against simple defeating...7 6 Installation...8 7 Electrical connection...8 7.1 Series connection of 2-10 fail-safe inductive sensors...9 8 Set-up...9 8.1 Setting aid...9 8.2 Determine the enable zone...10 8.3 Deactivate setting aid...10 9 Operation... 11 9.1 Sensor signals... 11 9.2 Input characteristics / output characteristics... 11 9.3 Cross faults...12 9.4 Operating mode...12 9.4.1 Delayed switching of the LED...13 9.4.2 Switching of the LED without delay...13 9.5 Response times...14 9.6 LED display...15 10 Technical data...16 11 Troubleshooting...18 12 Maintenance, repair and disposal...18 13 Terms and abbreviations...18 2

1 Preliminary note The instructions are part of the unit. They are intended for authorised persons according to the EMC, Low Voltage and Machinery Directives and safety regulations. The instructions contain information about the correct handling of the product. Read the instructions before use to familiarise yourself with operating conditions, installation and operation. Follow the safety instructions. 1.1 Symbols used Instructions Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. LED on LED off LED flashes (2 Hz) LED flashes quickly (5 Hz) 1.2 Warning signs used WARNING Warning of serious personal injury. Death or serious irreversible injuries may result. 3

2 Safety instructions Follow the operating instructions. Improper use may result in malfunctions of the unit. This can lead to personal injury and/or damage to property during operation of the machine. For this reason note all remarks on installation and handling given in this document. Also adhere to the safety instructions for the operation of the whole installation. In case of non-observance of notes or standards, especially when tampering with and/or modifying the unit, any liability and warranty is excluded. If the sensor is damaged, the safety function cannot be guaranteed. Errors caused by damage cannot be detected by the sensor. The unit must be installed, connected and put into operation by a qualified electrician trained in safety technology. The applicable technical standards for the corresponding application must be complied with. For installation the requirements according to EN 60204 must be observed. In case of malfunction of the unit please contact the manufacturer. Tampering with the unit is not allowed. Disconnect the unit externally before handling it. Also disconnect any independently supplied relay load circuits. After installation, maintenance or repair of the system perform a complete function check. Use the unit only in specified environmental conditions ( 10 Technical data). In case of special operating conditions please contact the manufacturer. Use only as described below ( 4). 2.1 Safety-related requirements regarding the application It must be ensured that the safety requirements of the respective application correspond to the requirements stated in these instructions. 4

WARNING Failure of the safety function When used outside of the defined environmental conditions, the safety-related function of the sensor cannot be guaranteed. Use only in accordance with the defined environmental conditions ( 10 Technical data). Use of the sensor in the vicinity of chemical and biological media (solid, liquid, gaseous) as well as ionising radiation is not permitted. Observe the following requirements: Take measures to avoid metallic objects being placed on the sensing face unintentionally. Adhere to EN 14119 for interlocking devices associated with guards. Adhere to the principle of normally closed operation for all external safety circuits connected to the system. In case of faults within the fail-safe sensor which result in the defined safe state: take measures to maintain the safe state when the complete control system continues to be operated. Replace damaged units. 3 Items supplied 1 fail-safe sensor GG507S with 2 M18 fixing nuts, 1 original operating instructions GG507S, ident no. 80236827. If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. 4 Functions and features The fail-safe inductive sensor GG507S detects metal without contact. Safety function SF: the safe state (output stage switched off; logic "0") is achieved when undamping greater than or equal to the safe switch-off distance s ar. ( 10 Technical data). Also observe the notes on installation of the sensor ( 6 Installation). The fail-safe inductive sensor is a proximity device with defined behaviour under fault conditions (PDDB) to IEC 60947-5-3. 5

The fail-safe sensor conforms to Performance Level e according to EN ISO 13849-1 as well as to the requirements SIL 3 to IEC 61508. The unit corresponds to the classification I1A18SP2 to IEC 60947-5-2 for flush installation ( 6 Installation). The fail-safe inductive sensor has been certified by TÜVNord. 5 Function "1" "0" 1: dual LED: signal (yellow); power (green) 2: close zone 3: enable zone 4: safe switch-off distance s ar 5: target 5.1 Enable zone The output is only enabled when damped in the enable zone. Outside this enable zone the output remains switched off. The safe switch-off distance s ar is > 10 mm. The enable zone is different if damping elements which deviate from the standard target plate in terms of material, form and size are used. Enable zone for selected materials*: Material Steel FE360 Stainless steel AIMg3G22 CuZn37 Copper Enable zone 1...4 mm 0.4...2.7 mm 0...1.4 mm 0...1.5 mm 0...0.8 mm 6

* Typical values for damping with a reference target of 24 x 24 x 1 mm and non-flush installation to IEC 60947-5-2 at an ambient temperature of 20 C. Depending on the characteristics of the damping element there may be no close zone. 5.2 Protection against simple defeating The fail-safe sensor reacts to metal objects, e.g. the frame of a safety door. Other metal objects that are not intended to enable the sensor must not be allowed to enable the fail-safe sensor unintentionally. Take measures to prevent metal objects, except the designated target, from being placed on the sensing face or in the enable zone unintentionally. In addition, the sensor has the following switching characteristics to make simple defeating of its safety function more difficult: 1. By slowly introducing a metallic object into the enable zone, the output is immediately switched, but displayed by the signal LED with a delay of about 3 s ( 9.4.1 Delayed switching of the LED). By doing so, the object is generally in the close range before the LED indication is lit. The technical instructions concerning the restart of the installation must be observed. 2. If the object stays in the close range for longer than approx. 2 s, the output is completely disabled and no longer enabled if damped in the enable zone. If the object stays in the close range for longer than approx. 5 s, the setting aid is activated ( 8.1). Release of the enable zone can be carried out either by undamping (> 10 mm) for a time of more than 2 s or by a voltage interruption ( 8.3 Deactivate setting aid). 7

6 Installation The unit is flush mountable according to IEC 60947-5-2, type I1A18SP2. Ensure the unit cannot work loose (tightening torque 25 Nm). Adhere to the installation conditions in accordance with the figures 1 to 3: 1 2 3 Tighten the socket according to the manufacturer's indications. Observe the tightening torque for the ifm socket (e.g. EVxxxx: 0.6...1.5 Nm). 7 Electrical connection Wiring diagram 10 Technical data Disconnect the unit. Also disconnect any independently supplied relay load circuits. Supply voltage: connect L+ to pin 1 and L- to pin 3 of the connector. The nominal voltage is 24 V DC. This voltage may vary between 19.2 V and 30 V incl. 5 % residual ripple to EN 61131-2. A safe industrial power supply with overvoltage protection must be used. In case of a fault, 42 V AC / 60 V DC must not be exceeded. 8

7.1 Series connection of 2-10 fail-safe inductive sensors 8 Set-up 8.1 Setting aid For easy and reliable installation the sensor features an optical setting aid to visualise the enable zone. 1: close zone 2: enable zone 0 10 mm > 5 s The setting aid is activated by placing a metal object in front of the fail-safe sensor (close range). After approx. 5 s the yellow LED starts to flash: the setting aid is active. While this mode is active, the output remains in the safe state ("0"). 9

8.2 Determine the enable zone When the setting aid is active, the enable zone can be determined by moving the target (or the sensor if the target is fixed). 0 10 mm As soon as the target enters the enable zone, the yellow LED goes out. If the target is just outside the enable zone in either direction the LED starts to flash again. 1: close zone 2: enable zone 8.3 Deactivate setting aid 0 10 mm < 2 s If the sensor is undamped for more than 2 s (> 10 mm), the setting aid is switched off and the yellow LED goes out. This can also be achieved by power off. > 2 s 1: close zone 2: enable zone 10

9 Operation 9.1 Sensor signals The safe state is when the output is switched off (zero-current state: logic "0"). The fail-safe sensor must be operated with a clock signal on its clock input (TE). The clock input signal must meet the defined time conditions (see figure). T t i_min = 50 ms t i t i_max = 450 ms 1 0 1 0 Δt i T min = 100 ms T max = 500 ms Δt i_min = 1,0 ms (+/- 10%) Δt i_max = 1,5 ms (+/- 10%) 1: clock input (TE) 2: output 9.2 Input characteristics / output characteristics The electrical input characteristics are compatible with the output characteristics to EN 61131-2 (nominal current 0.1 A and nominal voltage 24 V): Logic "1" 11 V, < 30 V Input current approx. 3 ma Logic "0" 5 V Leakage current 500 µa Permissible test pulse duration 1.0 ms If the target is in the enable zone and there is no sensor fault, the clock input signal is transferred to the output with the delay td. The output characteristics are compatible with the input characteristics to EN 61131-2 type 1 or 2: Logic "1" 15 V 11 V 2...15 ma 15...30 ma Output impedance typ. 27 Ω Logic "0" 5 V Leakage current 0 ma (pull-down current typ. 30 ma) If the target is outside the enable zone, the output is switched off (logic "0"). Non-observance of the time diagram (e.g. no time offset td; permanently logic "1" 9.1 Sensor signals) is a fault. 11

The interface corresponds to interface type B according to the ZVEI position paper "Klassifizierung binärer 24-V-Schnittstellen mit Testung im Bereich der Funktionalen Sicherheit" (Classification of binary 24 V interfaces tested with regard to functional safety). 9.3 Cross faults Cross faults are detected by the fail-safe sensor and lead to an error message (permanently logic "1"). The pull-down current of the clock generator must not exceed 30 ma as the fail-safe sensor can no longer switch this current. An error message is no longer possible then. 9.4 Operating mode The length of the preceding undamping determines whether the yellow LED comes on with a delay ( 9.4.1) or without delay ( 9.4.2) when a target moves into the enable zone. In any case, the output switches on without delay. In case of undamping the output switches off and the yellow LED goes out without delay. In case of damping in the close range the output switches off immediately whereas the yellow LED goes out with a delay of approx. 2 s. With the deactivation of the LED the output is maintained in the safe state (logic "0"). Thus, switching on again in the enable zone is not possible. Enabling is done by undamping (> 10 mm) of more than 2 s or by interrupting the voltage ( 5.2 Protection against simple defeating). 12

9.4.1 Delayed switching of the LED Undamping > 2 s: 0 > 3 s 10 mm If the target was away from the sensor for more than approx. 2 s (> 10 mm), the yellow LED goes on with a delay of approx. 3 s in case of damping in the enable zone. This is also the case if the target is in the enable zone when the voltage is switched on. 1: close zone 2: enable zone 9.4.2 Switching of the LED without delay Undamping < 2 s: If the target was away from the sensor for less than 2 s (> 10 mm), the yellow LED comes on without delay in case of damping in the enable zone. 0 0 s *) 10 mm 1: close zone 2: enable zone *) except for the first start-up 13

9.5 Response times (Without response time of the monitoring unit) Response time on safety request (removal from the enable zone) 20 ms 1) Response time when approaching the close range (non safetyrelated zone) Response time when approaching the enable zone (enable time) Response time when switching off the clock input Response time for enabling to rising edge of TE (damped in the enable zone) Response time / risk time for safety-related faults Permissible dwell time in the close range Delay time to activate the setting aid ( 8.1) Dwell time in the undamped condition ( 10 mm) to return into the operating mode ( 8.3 Deactivate setting aid) T typ. 100 ms 200 ms 2) 2 ms typ. 40 ms max. 100 ms T approx. 2 s approx. 5 s approx. 2 s 1) During this time the output is switched off (logic "0"). 2) As from this instant the clock input signal is transferred to the output with a delay. T 9.1 Sensor signals 14

9.6 LED display LED Operating status Sensor signals No voltage supply Undervoltage Overvoltage Output switched off (safe state), target outside the enable zone (operating mode) or target in the enable zone (setting aid) Output switched, target in the enable zone (operating mode) TE 1 0 A 1 0 Output switched off (safe state), target outside the enable zone (setting aid) Internal or external fault ( 11 Troubleshooting) 15

10 Technical data GIGA-4010-U Inductive sensors Product characteristics Fail-safe inductive sensor Metal thread M18 x 1 M12 connector Enable zone 1...4 mm; [f] flush mountable Complies with the requirements: EN ISO 13849-1: 2015 category 4 PL e IEC 61508: SIL 3 Application Type of operation Electrical data Electrical design Operating voltage 16 [V] continuous operation (maintenance-free) Current consumption [ma] < 15 Protection class Reverse polarity protection Outputs Output function Output data Short-circuit protection Range Enable zone [mm] 1...4 Safe switching off distance s(ar) [mm] 10 Reaction times -on delay time Response time to safety request [s] [ms] 5 20 Response time when approaching [ms] the enable zone (enable time) 200; typ. 100 Environment Applications Class C to EN 60654-1 weatherproof application Ambient temperature [ C] -25...70, for service life 87600 h 10...40, for service life 175200 h Rate of temperature change Max. relative air humidity [K/min] [%] 0.5 5...95, briefly 5...70, permanently Air pressure [kpa] 80...106 DC 24 DC (19.2...30 DC) III yes Clock signal Interface type B yes

Protection IP 68 / IP 69K; to EN 60529 Tests / approvals EMC IEC 60947-5-2 IEC 60947-5-3 EN 60947-5-2 EN 61000-4-2 ESD: EN 61000-4-3 HF radiated: EN 61000-4-4 Burst: EN 61000-4-6 HF conducted: EN 61000-4-8: EN 55011: 6 kv CD / 8 kv AD 20 V/m 2 kv 10 V 30 A/m class B Shock resistance IEC 60947-5-2 Vibration resistance IEC 60947-5-2 Safety classification Mission time TM Safety-related reliability PFHd Max. input capacitance Ci_max Mechanical data [h] [1/h] [nf] 175200, (20 years) 1.1E-09 2 Mounting flush mountable Housing materials Brass special coating; PBT Weight [kg] 0.188 Displays / operating elements Display LED yellow (signal), LED green (power) Electrical connection Connection Wiring M12 connector; Gold-plated contacts 1 = Safety-related logic unit Accessories Accessories (included) Remarks Remarks 2 lock nuts Unless stated otherwise, all data refer to the 24x24x1 mm reference target plate to IEC 60947-5-2 (FE360 = mild steel) over the whole temperature range. Pack quantity [piece] 1 ifm electronic gmbh Friedrichstraße 1 45128 Essen We reserve the right to make technical alterations without prior notice. GB GG507S-03 24.05.2016 17

11 Troubleshooting LED display 9.6 Problem Possible cause Troubleshooting No LED display No voltage supply Apply voltage LED flashes and sensor does not switch LED off and signal LED flashes Undervoltage Overvoltage Internal or external fault Correct the voltage ( 10 Technical data) Undamp / damp off / on Replace the unit Check wiring / connections Check external electronics (e.g. G150xS or PLC) 12 Maintenance, repair and disposal If used correctly, no maintenance and repair measures are necessary. Only the manufacturer is allowed to repair the unit. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. 13 Terms and abbreviations PDDB PFH (PFH D ) Proximity devices with defined behaviour under fault conditions Probability of (dangerous) Failure per Hour PL Performance Level PL to EN ISO 13849-1 SIL Safety Integrity Level SIL 1-4 to IEC 61508. The higher the SIL, the lower the probability that a safety function will fail. SIL cl Safety Integrity Level claim limit According to IEC 62061 T M Mission time Lifetime to EN 60947-5-3 (= max. service life) 18

19