Analog amplifier RA. RE Edition: Replaces:

Similar documents
Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

Analog Amplifier RA. RE B/ Replaces: English. Instruction manual

Speed sensor DSA series 12

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Valve amplifier for proportional valves. Type VT-SSPA1-1 (5, 50, 100, 150) Features. Contents. RE Edition: Replaces:

Electric amplifier for proportional cartridge throttle valves

Valve amplifier for high-response valves. Type VT-VRRA X/V0/2STV, VT-VRRA X/V0/PO-IS. Contents. Features

Electric amplifiers. Table of contents. Features RA 30052/ Model VT-VRPA1. Series 1X 1/6

Analog amplifier. RE 29926/10.06 Replaces: Type VT Component Series 3X

BODAS Controller RC Series 22

Electric amplifiers. List of contents. Features. RE 30052/08.05 Replaces: Type VT-VRPA1. Unit series 1X 1/6

Electric amplifiers. Table of contents. Features. RE 30054/03.12 Replaces: Type VT-VRPA X/...-RTP. Component series 1X 1/6

Valve amplifier for proportional valves with electrical position feedback

Electric amplifiers. Table of contents. Features. RE 30052/02.12 Replaces: Type VT-VRPA X/V0/... Component series 1X 1/6

Valve amplifier for proportional directional valves and proportional pressure valves. Type VT-VSPA2-1. Features. Contents

Electric amplifiers. Table of contents. Features. RE 30048/08.12 Replaces: Type VT-VRPA X/V0/RTP. Component series 1X 1/6

Electric amplifier for flow control with proportional

Valve amplifier for proportional valves. Type VT-MSPA2-1. Contents. Features. RE Edition: Replaces:

Valve amplifier for proportional pressure valves

MRS ELECTRONIC DATASHEET CAN I/O AND PLC DESCRIPTION TECHNICAL DATA REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

Valve amplifier for proportional directional valves. Type VT-VRPA2. Features. Contents. RE Edition: Replaces: 07.05

Booster amplifier. Table of contents. Features. RE 30260/04.12 Replaces: Type VT-MSFA1. Component series 1X 1/6

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Electronic amplifier for the control of proportional valves without position control Model VT 3024, Series 3X H/A 4149/94 VT X

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

4/3 proportional directional valve direct operated, with integrated electronics

High-response valve with integrated digital axis controller (IAC-R) and field bus interface

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

p/q closed-loop control amplifier

BODAS Controller RC. RE Edition: Replaces: RC28-14/30 RC20-10/30 RC12-10/30

Analogue amplifier. Features. Table of contents. RE 29980/09.05 Replaces: Type VT-SR2. Series 1X 1/6

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

PowerPlex Compact Module PP-C-COM24

Valve amplifier for proportional pressure valves

4/3 proportional directional valve with integrated digital electronics and field bus interface (IFB-P) Type 4WREF. Features.

Actuator LA12 PRODUCT DATA SHEET

BODAS Controller RC10-10 Series 31

Digital amplifier for proportional valves PEM XD

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

Smart Power Relay E I...

RT-5005/5006/5007/5008

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

DENISON HYDRAULICS Proportional Pressure Control Valves

Service case with test unit for servo and proportional valves with integral electronics (OBE)

BODAS Pressure sensor PR4

Digital Proportional Amplifier. Type: RT-VSPA2-50. Series: 3X. Table of contents. Features. RD13763/11.07 Replaces:

EFC 3600 Frequency converter for higher energy efficiency and improved process control

Drive Electronics pq11

Proportional Directional Control Valves Nominal sizes 16 and 25

58V signal frequency input analog input ( ma, PT1000. sensor) Programming System

EPA-M*** POWER AMPLIFIER FOR OPEN LOOP PROPORTIONAL VALVES SERIES 20

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

EC 45 flat with integrated electronics Document ID: en Operating Manual

Mobile dual solenoid driver

Speed sensors for general applications:

RA / /6. Replaces: Table of contents RA /06.98

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

POWER SYSTEM MODE STATUS

Fuse, external A 6A, medium time lag. Power consumption W min 20 - max 60 (see paragraph 5.2) Output current A maximum 4.5 (see paragraph 5.

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Proportional amplifier type EV22K5

Power supply CP-D 12/2.1

Electronic Air / Fuel Ratio Control System

TECHNICAL DATASHEET #TDAX CAN SAE J1939, Dual Output Valve Controller

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Sensor technologies Proximity sensors Series ST9. Brochure

Product Data Sheet 3252J/2H3PU

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

ELECTRONIC REGULATOR FOR OPEN LOOP

Technical Information Nivector FTC968, FTC968Z

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

Drive electronics pq11

Power supply CP-D 24/1.3

Technical Explanations. SKiiP 3 Parallel Board. Technical Explanation SKiiP 3 Parallel Board. This document is valid for the following part numbers:

Absolute Encoders Multiturn

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

Power supply CP-D 24/4.2 Primary switch mode power supply

Accessories Power Amplifiers

PHOENIX CONTACT

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 analog

Technical Documentation

Technical Data. General specifications. Rated operating distance s n 3 mm

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

Applications: oil and gas equipment automation; off-highway machine automation; agricultural equipment

Controller. 1 Proportional amplifier module ESSK 103. ESSK 103 and ELSK Description. 1.2 Application examples. 1.

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Absolute Encoders Singleturn

high grade, temperature resistant plastic, Thermoplast with brass inserts

Product Data Sheet RG160-28/18N/2TDPU-331

IB IL 24 PWR IN/PS IB IL 24 PWR IN/PS-PAC

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

maxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,

Proportional Directional Control Valves Size 6

Power supply CP-E 24/2.5

PHOENIX CONTACT - 09/2009

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

Magnetic Inductive Flow Sensor induq

Transcription:

Analog amplifier RA RE 950 Edition: 08.05 Replaces: 0.006 For control of simple functions of electrohydraulic components Two power outputs (PWM) and one switching output Each output has a separately adjustable time for upwards and downwards ramps Each output has separately adjustable minimum and maximum currents Features Optional interlock of actuation for proportional solenoids Supply voltage for external setpoint potentiometer Monitoring of setpoint potentiometer for cable breakage and short circuit Externally actuated switching output Error output Overload protection, overvoltage protection, conditional short-circuit protection Externally adjustable PWM frequency Contents Type code Ordering details Description Service options Technical data Characteristic curves 4 Block circuit diagram 5 Terminal connection 6 Terminal connection variant 7 Dimensions 8 Installation position 8 Project planning notes 9 Safety instructions 9 RE 950/08.05, Bosch Rexroth AG

RA Analog amplifier Type code Type code Description 0 0 0 RA - / 0 Type 0 Analog amplifier RA Version 0 st position: number of proportional outputs nd position: number of switching outputs Series 0 Series, index 0 0 Ordering details Type Version Series Material Number RA - / 0 R9009800 Mating connector Order designation for 5-pin Bosch mating connector comprising: Designation Material number Handle shell, angled Bosch 98 40 0 Contact carrier Bosch 98 400 95 Screw for contact carrier Bosch 98 49 08 Flat sealing ring for screws Bosch 98 00 98 Locking piece, lilac color Bosch 98 40 566 Clamping collar, large Bosch 98 400 890 screws for the clamping collar Bosch 98 49 5 Sleeve, angled, 8 mm Bosch 98 00 84 Seal for contact carrier Bosch 98 00 9 Clamping band for sleeve Bosch 98 40 80 5 contacts AMP 97775- The mating connector is not included in the scope of delivery. It can be ordered from Bosch Rexroth under the material number R906006. - The analog amplifier activates up to two proportional solenoids. The specified control voltage is processed in the amplifier as an input variable. The analog amplifier provides a regulated electric current as an output variable for actuation of proportional solenoids. The amplifier outputs for the proportional solenoids are activated by applying approx. 5% of the maximum setpoint voltage at the input, i.e., the minimum output current is applied. The level of this minimum output current can be adjusted separately for both proportional outputs using a trimming potentiometer. If the setpoint voltage at the input is increased, the output current for each respective proportional solenoid increases linearly. The maximum output current can also be separately adjusted using a trimming potentiometer for the outputs. The gradient of the output curve is influenced by this. The analog amplifier contains time ramp functions which can be used to adjust the period in which the output current can be adapted to match a modified setpoint. The ramp time adjustment range extends from 00 ms to 0 s. The time ramp functions can be adjusted using trimming potentiometers for each solenoid. Service options The RA analog amplifier can be used to actuate up to two proportional solenoids in a single device (for example a toggling axial piston unit or a valve section with separate actuation of the proportional solenoids) or to actuate two devices independently of each other (for example, two individual axial piston units or valves). The use of only one proportional output is possible. A A output for a switching function is also available. Bosch Rexroth AG, RE 950/08.05

Analog amplifier RA Technical data Technical data Analog amplifier RA- Nominal voltage Residual ripple (DIN 4089, Section ), maximum Supply voltage, perm. range Current consumption Fuse without load with load, max. and 4 V internal external: for switching and proportional solenoid outputs and for electronics Potentiometer supply voltage ± V 0 to V 50 ma 6 A 7.5 A T 0 V, 4.0 V for setpoint potentiometer to 5 kω depending on load 7. V to 8.4 V Voltage input (differential amplifier) (differential voltage) 4.0 V Switch input > 5.0 V Proportional solenoid outputs (PWM) Current range 0 to. A Pulsation frequency 00, 00 or 50 Hz Switch output (MOSFET) max. A LED indicators red Error (error display) green Power (operating state indicator) yellow I (PWM current channel ) yellow I (PWM current channel ) Error detection Potentiometer: for broken wires and short circuit Exception: wiper Voltage supply: undervoltage monitoring Resistance to short circuits To supply voltage and ground for all inputs and outputs (Exception: potentiometer supply 4.0 V to supply voltage) Reverse polarity protection Supply/battery Electromagnetic compatibility Spurious interference (motor vehicles directive 95/54/EC) Details on request 00 V ms /m Line-bound interference (ISO 767-/-/-) Values on request Load dump 70 V Max. power loss at V 4 W Operating temperature, case 40 to 85 C Storage temperature, case 40 to 85 C Vibration resistance Sinusoidal vibration (IEC 60086--6) 0 cycles per axis 0g / 57 to 000 Hz Random vibration (IEC 60086--6) 0 min. per axis 0.05 g /Hz Shock resistance Transport shock (IEC 60068--7) X in each direction (pos./neg.) and in each axis 5 g / ms Continuous shock (IEC 60068--9) 000X in each direction (pos./neg.) and in each axis 5 g / 6 ms RE 950/08.05, Bosch Rexroth AG

4 RA Analog amplifier Characteristic curves Analog amplifier RA- Resistance to moisture IEC 60068--0Db; version Resistance to salt spray 90 % (+5 C to +55 C) IEC 60068-- 7 h, 5 C, 5% NaCl Type of protection (DIN / EN 6059) with installed mating connector ) IP65 Case material Plastic injection molding PA66 GF 5 Mass, approx. 0. kg Outer dimensions Length 08 mm Width 5 mm Height 4 mm Characteristic curves For solenoids with interlocked actuation (toggling mode) For solenoids with independent actuation (parallel mode) I Solenoid ~0.8 x I max I max I Solenoid ~0.8 x I max I max Adjustment range Solenoid Adjustment range Solenoid Adjustment range ~0.06 x I max I min 0 V 4.0 V 8.4 V setpoint ~0.06 x I max 4.0 V (0 V) I min 8.4 V (4.0 V) setpoint ) For the appropriate routing of the connection cable, see Installation position Bosch Rexroth AG, RE 950/08.05

Analog amplifier RA Block circuit diagram 5 Block circuit diagram Supply voltage Solenoid Voltage range switchover Voltage input Solenoid Ramp off Potentiometer supply Solenoid 9 6 8 4 7 5 6 8 V pos V mid 7 DC DC 4 V Dig Out V pos V mid GND Power t up t down I max I min Err PWR PWM Err PWR PWM Err PWR Poti Error 6 I 5 I 5 4 Error output Proportional solenoid output PWM frequency 9 Potentiometer supply Solenoid Parallel mode Voltage input Solenoid 9 0 t up t down I max I 6 5 I 5 Proportional solenoid output I min Supply voltage Solenoid 0 8 V Dig Out 0 Switch input 4 7 Switching output Key Differential amplifier Time ramp function Reference voltage generation 4 LED operational status (Power) 5 LED displaying PWM current (I or I) 6 PWM output stage Key 7 Internal voltage supply 8 Sensor or potentiometer supply 9 Clock-pulse generator 0 Switch output 0 Error detection LED displaying error (Error) RE 950/08.05, Bosch Rexroth AG

6 RA Analog amplifier Terminal connection Terminal connection + V/ +4 V 0 V Ground Emergency stop 7,5 A Ignition lock with start non-repeat unit 9 6 Supply PWM Bat Error PWM ) Frequency Pin Bridge from 00 Hz open 00 Hz to GND to or 50 Hz to Bat to 9 Ramp off PWM frequency (see Table) Current range switchover ) 5 8 PWM output Proportional solenoid 4 ), A Potentiometer 6 4 + 7 - Differential input + - 5 Error output 8 V / 0 ma 8,4 V 4,0 V Sensor supply Voltage supply for the electronics Potentiometer 0 + - 0 8 Differential input + - Supply PWM PWM PWM output 5 ) Proportional solenoid, A Parallel operation 9 Open: Toggling Bat: Parallel operation Switch input 4 7 Switch output A ) ) connection options to switch over the PWM dither frequency (see Table): 00 Hz, 00 Hz, 50 Hz if required ) Ground connection for solenoid return lead to the battery (or chassis) possible ) Separate ground connections to the battery (or chassis) required; in the case of an inductive load, a freewheeling diode must be connected Bosch Rexroth AG, RE 950/08.05

Analog amplifier RA Terminal connection variant 7 Terminal connection variant Further terminal assignments e.g. for the control voltage or the control current specification can be found in the instruction manual 950-B. Toggling operation with single potentiometer If the analog amplifier RA is used in the toggling operation with just one potentiometer, then the potentiometer must be connected as per the following section: 6 / 7 4 8,4V 4,0V Sensor or potentiometer supply - + Differential input 0 - + Differential input / 8,4V 4,0V Parallel operation 9 Open: Toggling operation Key Analog input (4.0 V 8.4 V): Setpoint ( setpoint ) for output signal amplifier (solenoid ) Analog input (4.0 V 0.0 V): Setpoint ( setpoint ) for output signal amplifier (solenoid ) RE 950/08.05, Bosch Rexroth AG

8 RA Analog amplifier Dimensions Dimensions 5 8 0 0 4. 4 0 6.4 88 56 8 4 5 4 4 9 approx. Installation position The permissible installation position is with the plug positioned vertically downwards. The cable must be routed such that it lies completely or partially below the amplifier connection (see illustration). The IP65 type of protection is only achieved in the shown installation position in combination with a sealing of the connector relative to the wiring harness sleeve. Any ingress of water into the analog amplifier by way of the wiring harness must be avoided by routing the wiring harness accordingly. Bosch Rexroth AG, RE 950/08.05

Analog amplifier RA Project planning notes 9 Project planning notes Safety instructions The instruction manual 950-B must be observed during project planning and commissioning. The total of setpoints for parallel wired potentiometers must lie in a range between kω and 5 kω. Potentiometers with 4.7 kω or 5 kω are recommended. The externally actuated switch output can be used to actuate an additional device such as, e.g. for an emergency valve or a horn. Do not use a freewheeling diode in the the lines to the solenoids at Pin and. Other inductive consumers in the system must be equipped with freewheeling diodes. External switching contacts in the solenoid lines are not permissible. Toggling or parallel mode is applied to Pin 9: Not connected: toggling mode, interlocked actuation of Solenoid and Solenoid wired with + Bat parallel mode, independent of each other actuation of Solenoid and Solenoid To switch off the time ramp function, Pin 5 (ramp off) must be connected. The PWM frequency of the output current is set by connecting pin (PWM frequency). The PWM output stages are supplied with voltage via Pin 9 (Solenoid ) or Pin 0 (Solenoid ) separately. Interruption of the supply voltage enables them to be switched off individually and independent from each other. Connection of Pin 4 (Dig In) activates switch output (Pin 7, Dig Out). In contrast to digital control units analog amplifiers only allow a limited diagnosis and monitoring capability. The use of an analog amplifier in applications in which in the event of a error hazardous machine states may arise, is therefore not permissible without additional external protective measures. If an analog amplifier develops a error i.e. unintended actuation or switching off of one or several solenoids then malfunctions cannot be reliably prevented. The suggested circuits do not imply any technical liability of Bosch Rexroth for the system. The safety instructions in instruction manual 950-B must be observed. In emergency situations or a malfunction the operating voltage is to be externally interrupted. To this end, interruption of the electronic circuit s supply voltage is to be effected using an emergency stop switch. The emergency stop switch must be installed in an easily accessible position for the operator. Safe braking must be ensured when the emergency stop function is activated. To avoid malfunctions the lines shielded from and to the potentiometers are to be connected on one side with low-impedance to devices or vehicle ground. Cables to the electronics must not be routed close to other power-conducting cables in the machine or vehicle. A sufficient distance to radio systems must be maintained. All connectors must be unplugged from the electronics during electrical welding operations. The analog amplifier may only be wired up when in de-energized state. Cable connection must have a strain relief and be attached such that vibration will not cause any corrosion to the plug contacts. Contacts must be protected against corrosion. If the solenoid output is overloaded (short circuit) the relevant output is not constantly switched off. The two PWM outputs must not be connected to each other (bridged)! Faulty connections could cause unexpected signals at the outputs of the analog amplifier. RE 950/08.05, Bosch Rexroth AG

0 RA Analog amplifier Safety instructions Opening, modifying or repairing the analog amplifier RA is not permissible. Modifications or repairs to the wiring could lead to dangerous malfunctions. Make sure no pins are energized when the analog amplifier RA is not receiving power. System developments, installations and commissioning of electronic systems for controlling hydraulic drives must only be carried out by trained and experienced specialists who are sufficiently familiar with both the components used and the complete system. No defective or incorrectly functioning components may be used. If the components should fail or demonstrate faulty operation, then repairs must be performed immediately. If the analog amplifier RA is dropped, continued use is not permissible because unseen damage may affect its reliability. Operation of the analog amplifier RA must generally occur within the operating ranges specified and released in this data sheet, particularly with regard to voltage, current, temperature, vibration, shock and other described environmental influences. Bosch Rexroth AG Mobile Applications Glockeraustrasse 4 8975 Elchingen, Germany Service phone +49 95 40 50 60 info.bodas@boschrexroth.de www.boschrexroth.com/mobile-electronics This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging. Bosch Rexroth AG, RE 950/08.05