Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Similar documents
Product Guide. Analog Panel Meters in thermoplastic cases with slide-in-dials. K Series. with Moving-Coil Movement

Price List w.e.f 1st October 2018

DATA SHEET. Switchboard instruments,

Analog indicators. 1/2 Regulations and standards. 1/4 Technical descriptions

ANALOG PANEL METERS. Moving-iron meters EB16 EA16 EA17 EA19 EA12. Moving-coil meters with rectifiers MA17P MA19P MA12P. 3-phase voltmeters

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Conditions of delivery: Delivery in accordance with General Conditions Orgalime S Unless otherwise agreed upon, all equipment is in general

Basic Series Square Panel Meters Features Benefits

DATA SHEET. Voltmeters and Ammeters,

Analogue Meters BQ0x07 series BQ - Moving-coil Panel instruments BQ0107, BQ0207, BQ0307, BQ0407 & BQ0507 1)

EA16, EB16, EA17, EA19

Standard Program Technical Description

(240 ) Measurement of DC currents and DC voltages. Size (mm): Q48 Q144 Q72 Q144 Q48 Q144

Analogue Meters CQ0x07 series

MOVING-IRON METERS EA16, EB16, EA17, EA19, EA12 TYPES

ANALOGUE PANEL METERS. GMW We make your values visible Basic Series

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

Analog Panel Meters Preference Program Basic Series Vario Series

Product Guide. Transducers

BE96-V BE96-A BE96-HZ. AC Voltmeters (moving iron) ~A

Analog Panel Meters Preference Program Basic Series Vario Series

DIGEM f 96 x 48 EK. Applications. Description

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

LINAX 4000L Continuous-line recorder

AMIK 200 / 201 Technical Data Sheet

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Technical Data Sheet. x1000. kwh R Y B

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Overcurrent Protection / 7SJ45

INDEX IEC:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Light-strip indicator

ANALOGUE PANEL & SWITCHBOARD METERS

RS Pro ENGLISH. Datasheet

Electronic Thermostat TE-1 Version according to EN

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

EM-72 Electricity Meters for Current Transformers

ART500A SPEAKER ART500A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

MAVOWATT 4 Multifunction Power Meter

MODEL: 47LV. Digital Panel Meters 47 Series

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

SINEAX G 536 Phase Angle or Power Factor Transducer

ART300A SPEAKER ART300A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

Power analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.

Meters. Ampere Meter. Volt Meter. Watt Meter. Var. Meter. Power Factor Meter. Frequency Meter. Demand Meter. Meter Relay.

POINTAX 6000L2 Point Recorder

Moving Test - MT3000

XF2 Frequency Relay. Manual XF2 (Revision A)

Paladin Transducers 250 Series Class 0.5 and Class 0.2

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

RS Pro ENGLISH. Datasheet

Power analyzers and Energy Meters Power Analyzer Type WM14-DIN

EMBSIN 281 G Power factor transducer

DATA SHEET Selectable AC transducer TAS-311DG

Transducers for AC measurement. Types TAP, TAQ, TMF, TAA, TAV, TAC. Measurement of: watt, var, frequency, phase angle, voltage, current

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

METRAClip85 and 86 Clamp Multimeters

DP2000 ORDERING GUIDE To Order MODEL NO.

PECA 30E. Analyseur de signaux alternatifs Signal Analyser for Electrical Networks

METRAClip87 and 88 Clamp Multimeters

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Operating Manual. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM 770. Contents

Protection relays and controllers. Types TRANSAL DC-2TF, ACV-3TF, ACI-3TF, PFC-2TF TRANSAL DC-2TB, AVC- 3TB, ACI-3TB, PFC-2TB

DIGITAL PANEL METER N24 AND N25 METER SERIES

SINEAX U 553 Transducer for AC Voltage

Operating Manual. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM B

Complimentary Reference Material

Measuring centers MC3x0 series Energy Meters with Power Display Energy Meter WQ0217 & WQ1217 Energy Meter with analogue pointer WQ0207 & WQ2207

µr SERIES RECORDERS VIEW RECORDERS 4365 & 4375 Recorders FUNCTIONS FEATURES

SINEAX I 552 Transducer for AC current

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

Measuring current transformers of the W, W series

Exercise MM About the Multimeter

Digital Indicator DS 96/24

Wide Angle METER L Series

Jewell DPM EINE BEST IN CLASS

QUINT-PS-24DC/24DC/10

Energy Management Energy Meter Type EM21 72R Retro-Fit

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

T4500 AUTO SYNCHRONIZER T4800 LOAD SHARER T4900 VAR LOAD SHARER

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

Installation / Monitoring Technique

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

DIGITAL SYNCHRONIZING UNIT KS3.2 SERVICE MANUAL. 144 x 144 x 77 mm C E R T I F I E D

Multifunctional counter tico 772/773/774

General Specifications


XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Totalizing Counters mini-i

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Pivot-type Fixed Meter 110mm Angle [JIS C , RoHS Compatible Products] Wide Angle Meter. Series CAT. NO. VF-11M-03

For non-electrical quantities

Transcription:

Product Guide Analog Panel Meters in thermoplastic cases with slide-in-dials K Series 400.U.101.06 K Series PQ with Moving-Coil VQ LSP LSG EQ with Moving-Coil Rectifier with Moving-Coil / Moving-Coil Rectifier 240 o - Dial with Moving-Iron EQ SWT ZQ LSZ BIQ BIEQ CQ LSC LQ LSL with Moving-Iron Switchable Pointer-Type Frequency Meters Maximum Demand Indicators with Bimetallic / Bimetallic-Moving Iron s Power Factor Meters electronic circuit integrated Watt and VAr Meters electronic circuit integrated

Application General Data Analog Panel Meters in thermoplastic cases with slide-in-dials for standard applications in switchboard, generating set and control panel production for mounting in switchboards machine tools mosaic grid panels for measuring DC current or DC voltage, or, frequency, thermal maximum demand, power factor, active / reactive power connection direct or for use on transducers / shunts/ transformers Technical Data PQ 48 K PQ 72 K PQ 96 K PQ 144 K Moving - Coil dial interchangeable lettering possible to special order pointer bar / knife- edge pointer pointer (LS.) bold bar pointer (with knife - edge for class 1.0) pointer deflection 0... 90 o (all meters except LS.) 0... 240 o (LS.) case according to DIN IEC 61 554 square form stackable suitable for use in mosaic grid panels polycarbonate, flame - retardant window exchangeable glass or non - glaring glass option bezel detachable, black or gray option position of use vertical, horizontal option or to be specified between 15 to 165 o panel fixing swivel screw clamps, spring clamps (except size 144) terminal protection protective sleeves or full sized rear cover option marine application non- certified or option Germanischer Lloyd approbated option (except size 48) dimensions (in mm).q 48 K.Q 72 K.Q 96 K.Q 144 K bezel 48 72 96 144 case 42.5 66 90 136 panel cutout 45 +0.6 68 +0.7 92 +0.8 138 +1 panel thickness 40 mm on all meter sizes climatic suitability climatic class 3 according to VDE/VDI 3540 sheet 2 operating temperature 10 o C... +23 o C... +55 o C range storage temperature 25... +65 o C range relative humidity 75% annual average, non - condensing mechanical load shock 15 g, 11 ms vibration 2.5 g, 5... 55 Hz pivot and jewel moving - coil movement, core - magnet system DC current 0... 100 A up to 0... 100 A (PQ 48 K up to 0... 25 A) DC voltage 0... 60 mv up to 0... 600 V (PQ 48/72 K up to 0... 250 V) for use on 4... 20 ma mechanically suppressed zero, transducer no zero adjustment 0/4... 20 ma electrically suppressed zero, with zero adjustment for use with 0... 60 mv or 0... 150 mv external shunt (scaling to DIN series) weight approx. PQ 48 K PQ 72 K PQ 96 K PQ 144 K 0.11 kg 0.15 kg 0.2 kg 0.25 kg s zero position centre zero or off - set zero increased sensitivity to 4 k /V for voltmeters 1... 600 V to 10 k /V for voltmeters 1.5... 150 V with moving - coil movement refer to Data Sheet No. 410.D.101.## PSQ 48, PQ 72/96/144 RS (M-Series, ) refer to Data Sheet No. 010.D.101.## LSP 48/72/96/144 (M - Series, 240 o - Dial) refer to Data Sheet No. 011.D.101.## P 48/72/96/144 PrS (edgewise meters) refer to Data Sheet No. 010.D.201.## MP 48x24/72x24/96x24, P 144x36 (slim edgewise meters) refer to Data Sheet No. 010.D.301.##

VQ 48 K VQ 72 K VQ 96 K VQ 144 K Moving - Coil Rectifier LSP 72 K LSP 96 K LSG 72 K LSG 96 K Moving - Coil / Moving - Coil Rectifier 240 o - Dial pivot and jewel moving - coil movement; series - connected rectifier incorporated 0... 10 ma up to 0... 100 ma 0... 6 V up to 0... 600 V (VQ 48/72 K up to 0... 500 V) frequency range 40 Hz... 50 Hz... 10 khz same as PQ 48/72/96/144 K LSP : pivot and jewel moving - coil movement, swivel - coil system LSG: rectifier incorporated LSP 72/96 K DC current 0... 100 A up to 0... 4 A DC voltage 0... 60 mv up to 0... 600 V (LSP 72 K up to 0... 250 V) for use on 4... 20 ma mechanically suppressed zero, transducer no zero adjustment 0/4... 20 ma electrically suppressed zero, with zero adjustment for use with 0... 60 mv or 0... 150 mv external shunt (scaling to DIN series) LSG 72/96 K 0... 100 A up to 0... 5 A for use on transformer 0... 1 A or 0... 5 A * ) ** ) 0... 1.5 V up to 0... 600 V (LSG 72 K up to 0... 500 V) for use on transformer 0... 100 V or 0... 110 V * ) * ) scaling to DIN series; no overload range ** )optional: with overload range frequency range voltage 40 Hz... 50 Hz... 10 khz current 50 Hz (others on request) accuracy class 1.5 or as an option class 1.0 with moving - coil rectifier movement refer to Data Sheet No. 415.D.101.## GSQ 48, GQ 72/96/144 RS (M-Series, ) refer to Data Sheet No. 015.D.101.## LSG 48/72/96/144 (M - Series, 240 o - Dial) refer to Data Sheet No. 016.D.101.## G 48/72/96/144 PrS (edgewise meters) refer to Data Sheet No. 015.D.201.## MG 48x24/72x24/96x24, G 144x36 (slim edgewise meters) refer to Data Sheet No. 015.D.301.## weight approx. LSP/G 72 K LSP/G 96 K 0.25 kg 0.3 kg s special measuring ranges, range adjustment, expanded scale, increased sensitivity, calibration to a firm internal resistance value or a lead resistance deviating from standard, off - set zero, coloured scales, dial illumination and others refer to Data Sheet No. 411.D.101.##

EQ 48 K EQ 72 K EQ 96 K EQ 144 K Moving - Iron EQ 72 SWT EQ 96 SWT Switchable Meters with Moving - Iron pivot and jewel moving - iron movement, silicon oil damped 0... 1 / 2 A up to 0... 100 / 200 A (EQ 48 K up to 0... 25 / 50 A) * ) ** ) for use on CT 0... N / 1 / 2 A or 0... N / 5 / 10 A * ) ** ) 0... 60 V up to 0... 600 V (EQ 48 K up to 0... 500 V) for use on VT 0... 100 / 120 V or 0... 110 / 132 V * ) * ) scaling to DIN series with overload scaling ** )optional: without overload range or with overload range 5 times rated current power consumption <4.5 VA (voltmeters) <0.5 VA (ammeters 15A) <0.8 VA (ammeters >15A) frequency range 16 2 / 3... 100 Hz weight approx. EQ 48 K EQ 72 K EQ 96 K EQ 144 K 0.1 kg 0.15 kg 0.2 kg 0.25 kg pivot and jewel moving - iron movement, silicon oil damped With the built - in 6 position switch, all voltages in a 4 - wire 3 - phase system can be measured. 0... 500 V for use on VT 0... N/100 V * ) * ) scaling to DIN series with overload scaling full scale value = 1.2 times rated value power consumption <4.5 VA frequency range 16 2 / 3... 100 Hz switch positions in a 4 - wire 3 - phase system 6 switch positions L1L3; L2L3; L1L2; L1N; L2N; L3N weight approx. EQ 72 SWT EQ 96 SWT 0.19 kg 0.23 kg with moving - iron movements refer to Data Sheet No. 420.D.101.## WSQ 48, WQ 72/96/144 RS (M-Series, ) refer to Data Sheet No. 020.D.101.## W 72/96/144 PrS (edgewise meters) refer to Data Sheet No. 020.D.201.## WQ 96/144 /2S (M- Series, 2 movements) refer to Data Sheet No. 023.D.101.## W 192 RnS/RhS (M-Series, triple combination meters) refer to Data Sheet No. 050.D.251.## refer to Data Sheet No. 421.D.101.##

ZQ 48 K ZQ 72 K ZQ 96 K ZQ 144 K LSZ 96 K Pointer - Type Frequency Meters 90 o - or 240 o - Dial BIQ 48 K BIEQ 72 K BIQ 72 K BIEQ 96 K BIQ 96 K Maximum Demand Indicators with Bimetallic / Bimetallic - Moving - Iron s pivot and jewel moving - coil movement with integrated electronic circuit frequency range 45... 50... 55 Hz 48... 50... 52 Hz 55... 60... 65 Hz 58... 60... 62 Hz 180... 200... 220 Hz 360... 400... 440 Hz 380... 400... 420 Hz rated voltage 57.8 V up to 500 V ZQ 48 K 110 V only) admissible voltage 15%... +10% variation power consumption 3 VA accuracy class 0.5 acc. to DIN EN 60 051-1 weight approx. ZQ 48 K ZQ 72 K ZQ 96 K ZQ 144 K LSZ 96 K 0.13 kg 0.3 kg 0.3 kg 0.3 kg (ZQ 48/72/96/144 K only) BIQ 48/72/96 K Bimetallic movement with resetable slave pointer BIEQ 72/96 K Bimetallic movement with resetable slave pointer + pivot and jewel moving - iron movement bimetallic 0... 1 / 1.2 A or 0... 5 / 6 A moving- iron 0... 1 / 2 A 0... 5 / 10 A for use on CT (scaling to DIN series) bimetallic 0... N / 1 / 1.2 A or 0... N / 5 / 6 A moving- iron 0... N / 1 / 2 A 0... N / 5 / 10 A (scaling with overload range) thermal time lag 15 min (standard) (bimetallic) 8 min (optional)) frequency range 50... 100 Hz or optional calibration to a definite frequency 100... 1000 Hz accuracy acc. to DIN EN 60 051-1 bimetallic class 3 (referred to slave pointer) moving- iron class 1.5 mounting depth BIQ 48 K BIQ/BIEQ 72 K BIQ/BIEQ 96 K 48 mm 53 mm 60 mm weight approx. BIQ 48 K BIQ/BIEQ 72 K BIQ/BIEQ 96 K 0.1 kg 0.2 kg 0.26/0.3 kg accessories saturating current transformers additional indicators for frequency refer to Data Sheet No. 432.D.101.## FQ 48/72/96/144 (M - Series, vibrating reed frequency meters) refer to Data Sheet No. 030.D.101.## FQ 96/144 /2 (M - Series, vibrating reed frequency meters with 2 movements) refer to Data Sheet No. 031.D.101.## with bimetallic movements refer to Data Sheet No. 450.D.101.## BI 72/96/144, BIW 96/144, BIW 72/96/144 GD (M-Series, ) refer to Data Sheet No. 050.D.101.## BI/BIW 192 RnS/RhS (M-Series, triple combination meters) refer to Data Sheet No. 050.D.251.##

CQ 96 K CQ 144 K LSC 96 K Electronic Power Factor Meters 90 o - or 240 o - Dial LQ 96 K LQ 144 K LSL 96 K Electronic Watt and VAr Meters 90 o - or 240 o - Dial pivot and jewel moving - coil movement with integrated electronic circuit type E single phase AC system D 3 phase 3 wire balanced load measuring ranges cap 0.5... 1... 0.5 ind (cos ) cap 0.8... 1... 0.3 ind cap 0.8... 1... 0.8 ind rated voltage 57.7 V... 100; 110 V * ) up to 500 V rated current 1 or 5 A * ) * ) also for use on transformers frequency range 49... 50... 51 Hz (single phase AC system) 45... 50... 65 Hz (3 phase 3 wire system) power consumption 0.1 VA (current circuit) 3.0 VA (voltage circuit) others mounting depth 104 mm weight approx. CQ 96 K CQ 144 K LSC 96 K 0.55 kg 0.75 kg 0.55 kg pivot and jewel moving - coil movement with integrated electronic circuit type active / reactive power single phase AC system EW 1 EB 1 3 phase 3 wire balanced load DW 1 DB 1 3 phase 4 wire balanced load VW 1 VB 1 3 phase 3 wire unbalanced load DW 2 DB 2 3 phase 4 wire unbalanced load VW 3 VB 3 select full- scale values between 0.6 and 1.2 times the calculated apparent power, preferably from standardized series 1 1.2 1.5 2 2.5 3 4 5 6 7.5 8 and any decimal multiple of these numbers. rated voltage 57.7 V... 100; 110 V * ) up to 500 V rated current 1 or 5 A * ) also for use on transformers power consumption 0.2 VA (on each current circuit) 3.0... 4.3 VA (on each voltage circuit) others mounting depth 104 mm (EW/B1, DW/B 1, VW/B 1, DW/B 2) 129 mm (VW/B 3, LSL 96 K all types) weight approx. 1.1 kg additional power factor meters refer to Data Sheet No. 460.D.101.## LFUQ 96/144 (M - Series, ) refer to Data Sheet No. 060.D.101.## additional Watt and VAr Meters refer to Data Sheet No. 470.D.101.## LDQ 96/144 (M - Series,, electrodynamic movement) refer to Data Sheet No. 070.D.101.## Weigel Meßgeräte GmbH Postfach 720 154 90241 Nürnberg Phone: 0911/42347-0 Erlenstraße 14 90441 Nürnberg Fax: 0911/42347-39 Sales: Phone: 0911/ 42347-94 Internet: http://www.weigel messgeraete.de e mail: vertrieb@weigel messgeraete.de specifications subject to change without notice; date of issue 05/11