4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

Similar documents
Sentry Digital Timers

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

OPERATING INSTRUCTIONS Digital weekly time switch

C-Bus DSI Gateway. 5508DSIP Series. Installation Instructions

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

DIN Rail Time & Twilight Switches

ENGLISH PORTUGUÊS NEDERLANDS DAB200

Radio-control universal dimmer (built-in type) Installation Instructions

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

Radio bus system Radio-universal dimming actuator, 1-gang. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

Technical Description. DCF77 Receiver-Module 4460

16-Channel Yearly Time Switch TR 648 S DCF

Contents ... What is DAB + Digital Radio?... 2 Setting up... 3 Backlit display... 4 Using headphones... 4 Your radio Switch off...

Universal Radio Cord Dimmer Order No.: Function

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS

ISOMETER IRDH575. Approvals

SA-027HQ 365-Day Annual Timer

UR200SI / UR200WE ENGLISH

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

DEUTSCH NORSK ENGLISH SVENSKA FRANÇAIS DANSK NEDERLANDS ČEŠTINA ITALANIO Hersteller UR190

V22 Thermostat N515/R00( )

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

TABLE OF CONTENTS. Electromatic Equipment Co., Inc. -1-

DEUTSCH NEDERLANDS ENGLISH ESPAÑOL FRANÇAIS PORTUGUÊS DAB2035

Instruction manual. art Installation manual

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

User Manual. AZATOM Blackfriars DAB Speaker. This manual is available to download online at

Data sheet. Function description. Benefits

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Protection and safety SQZ3 phase and sequence relay

MANUAL. PT Series 365 Day Annual Timer. Tel:

WLDS-10 Mk3 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

Monitoring Relay MR 50

Chapter5 Camera Settings and Other Functions

DEUTSCH ITALANIO ENGLISH NORSK FRANÇAIS DANSK NEDERLANDS Hersteller UR8200

Comfort Digisystem User Manual. SecureStream Technology. Microphone DM05. English

SDMO. Changeover switch VERSO 200

LIGHTING CONTROL PANEL

User Instructions For TopTronic RS-10

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8

WLDS-10 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

Modular Devices and Enclosures

Operation Instructions. Verona CR 43

Instruction Manual AlfaSpid Rotator and Controller

Alarm-Display SD 9648

SMARTRIPPLE Geyser Load Control Timer

LK Wireless Room Control Cq

Synchroniser Relay SYN-7

Stereo DAB+/FM Radio

vacon 100 flow ac drives application manual

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

Portable Digital & FM Radio

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

User Manual. Internet Radio Adaptor with DAB and Bluetooth DBA-03R. (Additional powered speaker / active speaker is required to use this product)

ADI-100 Interrupter. Operator s Manual. 526 S. Seminole Bartlesville, OK /

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

R7426A. MicroniK 200 TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK

Digital DAB and FM Radio

S-Series Digital Thermostat

Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

Always there to help you. Register your product and get support at AJB4300. Question? Contact Philips.

USER MANUAL. Model No.: DB-230

Comfort Digisystem User Manual. SecureStream Technology. Receiver DH10. English

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.

Documentation. Measurement and Control. Type: ELT-GP2

KLF 100. Directions for use ENGLISH VAS

AT-SL-DDR & AT-SL-DDR-SA

Documentation. Content. Measurement and Control. Type: ELT-GP1. 1. Installation instructions 2. Data sheets 3. Declarations of conformity

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Alemite FCS Fluid Control System

Electronic Heat Cost Allocator GRADUS User Manual

Microquartz ALFA AFNOR TBT

HP Photosmart R740 series Digital Camera. User Guide

RCMS460 and RCMS490 Series

AMANO PIX-21. Electronic Time Recorder. Operation Manual

Short form User Manual

User Manual. Last updated on September 5, 2008

R9999 ROBERTS. PLL Synthesised 3 band radio with station name display. Sound for Generations. Please read this manual before use

Message Greeter Installation and User Manual

Ultimate Football Timer.qxd 12/17/06 1:33 PM Page 1

IXIAN TM class V 1.5. EC Transmitter This is an evolving document. EC Transmitter IXIAN TM. Features

Digital Electronic Thermostat With RF

Operation Instructions. Boston CC 22

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

AT-SL-DDR & AT-SL-DDR-SA

animeo KNX 4 AC Motor Controller 31. March 2016 WM/DRM V AC

HP Photosmart Mz60 series Digital Camera. User Guide

Transcription:

Digital 7-Day Programmable Timer 4TCD1 Schneider Electric (Australia) Pty Ltd Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Installation Instructions Schneider Electric (Australia) Pty Ltd reserves the right to change specifications, modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be liable for any error therein. 2013 Schneider Electric. All Rights Reserved. Trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. F2416/01 CLIPCOM 26086 April 2013

Safety precautions The connection and installation of electrical devices may only be carried out by a qualified electrician. Interventions in and changes to the device result in voiding of the warranty claim. Observe Australian electrical regulations and the respective safety provisions. Fixed and flexible cable conductors of up to 2.5 mm 2 may be attached to the external terminal clips. Flexible cables with a cross section 1 mm 2 should not be attached. General information Deactivation commands take priority over activation commands. If the power supply is consistent, the dots shown between the hours and minutes (HH:MM) are displayed permanently. The dots flash if the power supply is interrupted. If there is no power supply, the position indicator display goes out after 1 minute (sleep function). The battery requires changing when the whole display flashes and will continue to flash for a maximum period of 2 weeks. Installation on DIN rail Terminal diagram 3 2 1 L M ~ C1 N L N 1 2 3

Battery change Attention! The battery change may only be carried out by a qualified electrician! Type: CR 2032 Isolate the device before replacing the battery. Check battery polarity when replacing. reset General information The middle communication line shows the selectable menu item. If confirmed with, this item is activated. Flashing texts or symbols require an entry. If no entries are made within the next 2 minutes, the clock reverts to Auto mode. The time switch has a sleep function when not connected to a power supply, that keeps the screen blank. This function is activated after 2 minutes of no key board operations. All settings saved will remain in the memory.

Interface Display A Channel status display = Channel 1 ON = Channel 1 OFF B 2 communication lines for time display, menu items, entry prompts etc. C Day of week display D Display of summer/winter time E Holiday mode display F Display of AM/PM G Operating voltage (permanently lit dots) Reserve power operation (dots flash) C B A 1 2 3 4 5 6 7 PROGRAM AM 14:26 PM + Res. FIX - Menu /Esc D E F G Buttons + Scroll up in menu Press briefly = +1 Press and hold = +5 (approx. 2 sec.) Scroll down in menu Press briefly = -1 Press and hold = -5 (approx. 2 sec) Manual operation in the Automatic mode. Res. The programs are retained in the case of a reset. The date and time must be set again. Press reset button with a blunt object (pen). Menu Exits the Automatic mode and enters the Programming mode Esc Press briefly = one step back Press and hold (approx. 2 sec) = return to Automatic mode Make selection and apply

1 Initial start-up Selection of menu language LANGUAGE ENGLISH English Deutsch Francais Español Italiano Nederland Portugues Czech + - Menu /Esc Res In the delivered state the time switch is in Auto mode with a preset time, date and the menu language English. After selecting language, the time switch jumps automatically to Program mode after 4 seconds. Program PROGRAM + - Menu /Esc Res

Program New weekly program NEW WEEKLY FREE 50 ON DAY ON HOUR ON MIN 15:00 18:00 SAVED WEEKLY 01:02 00:00 15:00 OFF DAY OFF HOUR OFF MIN Esc The time switch has 50 memory spaces (25 ON, 25 OFF). Example ON command at 3 pm. OFF command at 6 pm. Select NEW program and confirm with. Select WEEKLY program and confirm with. The free memory spaces are briefly displayed. Select day block or individual day (block formation as desired) and confirm with. Enter hour for ON command () and confirm with. Enter minute for ON command () and confirm with. Enter hour for OFF command () and confirm with. Enter minute for OFF command () and confirm with. Program is saved. Program jumps to selection WEEKLY. Now additional programs can be created.

New holidays program NEW HOLIDAY FREE 50 The HOLIDAY program is run every year unless changes are programmed in. FROM MON FROM DAY TO MON TO DAY 01:01 07:01 07:26 08:01 ON DAY ON HOUR ON MIN OFF DAY 00:00 15:00 OFF HOUR OFF MIN SAVED HOLIDAY 15:00 18:00 03:04 Esc

Program View, edit program EDIT PO1 PO2 15:00 18:00 OFF DAY OFF HOUR OFF MIN 18:00 19:00 Delete all programs PO2 19:00 Esc CONFIRM The program steps can be scrolled through with. The respective program can be edited by pressing. The procedure is the same as when creating a new program. When deleting individual programs, the corresponding program steps are deleted e.g. P01 ON and P02 OFF. DELETE ALL CONFIRM Delete individual programs DELETE SELECT PO1 15:00

Set date and time PROGRAM DATETIME YEAR 2013 The date and time are preset at the factory. MONTH DATE HOUR MINUTE 0101 0701 00:00 21:00 Set AM/PM (12-hour-) or 24-hour display PROGRAM 12H 24H 24H AM PM 21:57 21:57 09:57 Esc

Switchover for summer/winter time PROGRAM DAYLIGHT AUTO The following settings are possible: AUTO Factory presetting of the published calendar dates. This is automatically recalculated for each year. SUMMER WINTER 03:25 10:28 PROGRAM DAYLIGHT NO NO No switchover

PROGRAM DAYLIGHT CALIBRAT SU MONTH 03:25 SU DAY 03:21 WI MONTH 10:28 WI DAY 10:31 Calibrate Programming the start date of the summer time and winter time must be entered for this purpose. The factory presetting is overwritten. The programmed summer/ winter time is automatically recalculated for each year. The changeover takes place on the same specified day of the week in the same week of each month. Also ideal for daylight savings periods. Example 10/03 start summer time 03/31 start winter time Attention! During the Summer/Winter switchover, alterations to time settings cannot occur. SUMMER 10:03 WINTER 03:31

Operating mode + - Menu /Esc Info Press 1 x = FIX ON = continuous ON Press 2 x = FIX OFF = continuous OFF Press 3 x = return to Auto mode FIX ON: FIX FIX OFF: FIX AUTO: (no display) programmed switching times Res Technical Specifications Dimensions H x W x D 45mm x 17.5mm x 60mm Weight g (approx.) 90 Supply voltage See imprint on device Power consumption 5 VA Switching capacity - Ohmic load (VDE, IEC) - Inductive load cos ϕ 0.6 - Incandescent lamp load 16A 250V a.c. 8A 250V a.c. 1,000W Switching output potential-free Switch contacts 1 changeover contact Ambient temperature -13 F to 131 F (-25 C to +55 C) Protection class II Accuracy typ. ±2.5 s/day at +68 F (20 C) Reserve power 3 years from factory at 68 F (20 C) Shortest switching time 1 min. Memory spaces 50 Block formation of day of the week Fixed/free selection Switching status display Yes Sealable Yes