Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm

Similar documents
Frequency comb swept lasers

Optical coherence tomography

MEMS tunable VCSEL light source for ultrahigh speed 60kHz - 1MHz axial scan rate and long range centimeter class OCT imaging

Extended coherence length megahertz FDML and its application for anterior segment imaging

Frequency comb swept lasers for optical coherence tomography

Laser Sources for Frequency-Domain Optical Coherence Tomography FD-OCT

Cheng, KHY; Standish, BA; Yang, VXD; Cheung, KKY; Gu, X; Lam, EY; Wong, KKY

Axsun OCT Swept Laser and System

Frequency comb swept lasers

Short Ring Cavity Swept Source Based on a Highly Reflective Chirped FBG

Temporal coherence characteristics of a superluminescent diode system with an optical feedback mechanism

Characterization of a fibre optic swept laser source at 1!m for optical coherence tomography imaging systems

The Theta Laser A Low Noise Chirped Pulse Laser. Dimitrios Mandridis

Ultrahigh speed volumetric ophthalmic OCT imaging at 850nm and 1050nm

Multi-Megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second

Isolator-Free 840-nm Broadband SLEDs for High-Resolution OCT

High-speed imaging of human retina in vivo with swept-source optical coherence tomography

All-fiber, short-cavity-length wavelength swept laser based on Fabry-Perot filter

Real-Time Experimental Measurement of Swept Source VCSEL Properties Relevant to OCT Imaging

Kent Academic Repository

taccor Optional features Overview Turn-key GHz femtosecond laser

Optical Coherence Tomography Systems and signal processing in SD-OCT

High-Coherence Wavelength Swept Light Source

some aspects of Optical Coherence Tomography

High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength

Picosecond pulses from wavelength swept continuous-wave. Fourier domain mode locked lasers

A new picosecond Laser pulse generation method.

60 MHz A-line rate ultra-high speed Fourier-domain optical coherence tomography

Piezoelectric transducer based miniature catheter for ultrahigh speed endoscopic optical coherence tomography

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

Simultaneous acquisition of the real and imaginary components in Fourier domain optical coherence tomography using harmonic detection

Optical frequency domain imaging with a rapidly swept laser in the nm range

Chapter 1. Overview. 1.1 Introduction

Ultrahigh Speed Spectral / Fourier Domain Ophthalmic OCT Imaging

Testing with Femtosecond Pulses

Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain modelocked

Full-range k -domain linearization in spectral-domain optical coherence tomography

A miniature all-optical photoacoustic imaging probe

Visualization of human retinal micro-capillaries with phase contrast high-speed optical coherence tomography

Pulsed-source spectral-domain optical coherence tomography with reduced motion artifacts

Simultaneous Measurements for Tunable Laser Source Linewidth with Homodyne Detection

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Photoacoustic imaging using an 8-beam Fabry-Perot scanner

SUPPLEMENTARY INFORMATION

Continuum White Light Generation. WhiteLase: High Power Ultrabroadband

Volumetric microvascular imaging of human retina using optical coherence tomography with a novel motion contrast technique

Powerful Single-Frequency Laser System based on a Cu-laser pumped Dye Laser

Supplementary Materials for

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

Examination Optoelectronic Communication Technology. April 11, Name: Student ID number: OCT1 1: OCT 2: OCT 3: OCT 4: Total: Grade:

High-frequency tuning of high-powered DFB MOPA system with diffraction limited power up to 1.5W

Multiwavelength Single-Longitudinal-Mode Ytterbium-Doped Fiber Laser. Citation IEEE Photon. Technol. Lett., 2013, v. 25, p.

UNMATCHED OUTPUT POWER AND TUNING RANGE

Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal

Customized Lasers for Specific Swept Source OCT Applications. Bill Ahern Axsun Technologies, Inc. June 20, 2013

Active mode-locking of miniature fiber Fabry-Perot laser (FFPL) in a ring cavity

Integrated photonic circuit in silicon on insulator for Fourier domain optical coherence tomography

Wavelength switching using multicavity semiconductor laser diodes

Improved lateral resolution in optical coherence tomography by digital focusing using twodimensional numerical diffraction method

Doppler-free Fourier transform spectroscopy

Swept Wavelength Testing:

Dynamic Sensor Interrogation Using Wavelength-Swept Laser with a Polygon-Scanner-Based Wavelength Filter

Multiwatts narrow linewidth fiber Raman amplifiers

Introduction Fundamental of optical amplifiers Types of optical amplifiers

High brightness semiconductor lasers M.L. Osowski, W. Hu, R.M. Lammert, T. Liu, Y. Ma, S.W. Oh, C. Panja, P.T. Rudy, T. Stakelon and J.E.

Development of Nano Second Pulsed Lasers Using Polarization Maintaining Fibers

DBR based passively mode-locked 1.5m semiconductor laser with 9 nm tuning range Moskalenko, V.; Williams, K.A.; Bente, E.A.J.M.

Performance Analysis of Chromatic Dispersion Compensation of a Chirped Fiber Grating on a Differential Phase-shift-keyed Transmission

Optical Fibers p. 1 Basic Concepts p. 1 Step-Index Fibers p. 2 Graded-Index Fibers p. 4 Design and Fabrication p. 6 Silica Fibers p.

Fiber Laser Chirped Pulse Amplifier

Non-contact Photoacoustic Tomography using holographic full field detection

Glaucoma Advanced, LAbel-free High resolution Automated OCT Diagnostics GALAHAD

NIH Public Access Author Manuscript Meas Sci Technol. Author manuscript; available in PMC 2014 June 01.

Fiber-optic Michelson Interferometer Sensor Fabricated by Femtosecond Lasers

Elements of Optical Networking

How to build an Er:fiber femtosecond laser

Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting

Final Year Projects 2016/7 Integrated Photonics Group

R. J. Jones Optical Sciences OPTI 511L Fall 2017

OPTICAL COHERENCE TOMOGRAPHY: OCT supports industrial nondestructive depth analysis

Pulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts

Theoretical Approach. Why do we need ultra short technology?? INTRODUCTION:

Fiber-Optic Communication Systems

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Frequency Noise Reduction of Integrated Laser Source with On-Chip Optical Feedback

COMPONENTS OF OPTICAL INSTRUMENTS. Chapter 7 UV, Visible and IR Instruments

COMPONENTS OF OPTICAL INSTRUMENTS. Topics

External-Cavity Tapered Semiconductor Ring Lasers

High-power semiconductor lasers for applications requiring GHz linewidth source

Introduction Fundamentals of laser Types of lasers Semiconductor lasers

Spider Pulse Characterization

Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Stabilisation of Linear-cavity Fibre Laser Using a Saturable Absorber

A Fiber Laser Spectrometer Demodulation of Fiber Bragg Grating Sensors for Measurement Linearity Enhancement

Lecture 25 Optical Coherence Tomography

University of Central Florida. Mohammad Umar Piracha University of Central Florida. Doctoral Dissertation (Open Access)

Dr. Rüdiger Paschotta RP Photonics Consulting GmbH. Competence Area: Fiber Devices

Transcription:

Megahertz FDML Laser with up to 143nm Sweep Range for Ultrahigh Resolution OCT at 1050nm Jan Philip Kolb 1,2, Thomas Klein 2,3, Mattias Eibl 1,2, Tom Pfeiffer 1,2, Wolfgang Wieser 2,3 and Robert Huber 1 1 Institut für Biomedizinische Optik, Universität zu Lübeck, Lübeck, Peter-Monnik-Weg 4, 23562 Lubeck, Germany 2 Lehrstuhl für BioMolekulare Optik, Fakultät für Physik, Ludwig-Maximilians-Universität München, Oettingenstr. 67, 80538 Munich, Germany 3 Optores GmbH, Gollierstr. 70, 80339 Munich, Germany ABSTRACT We present a new design of a Fourier Domain Mode Locked laser (FDML laser), which provides a new record in sweep range at ~1µm center wavelength: At the fundamental sweep rate of 2x417 khz we reach 143nm bandwidth and 120nm with 4x buffering at 1.67MHz sweep rate. The latter configuration of our system is characterized: The FWHM of the point spread function (PSF) of a mirror is 5.6µm (in tissue). Human in vivo retinal imaging is performed with the MHz laser showing more details in vascular structures. Here we could measure an axial resolution of 6.0µm by determining the FWHM of specular reflex in the image. Additionally, challenges related to such a high sweep bandwidth such as water absorption are investigated. Keywords: Optical coherence tomography, OCT, tunable laser, Fourier domain mode locking, FDML, MHz OCT 1. INTRODUCTION Optical coherence tomography (OCT) enables the non-invasive study of morphological features of the human retina with high resolution. The transverse resolution is determined by the optical design of the system and aberrations of the human eye. If the latter is corrected with adaptive optics individual photoreceptors can be visualized [1] even at MHz A-scan rate [2]. The axial resolution is independent of the optics and scales with the square of the central wavelength of the light source and with the inverse of its bandwidth. Since non-sweeping light sources such as super continuum lasers have considerably higher bandwidth than swept laser sources [3-5], spectral domain OCT is still superior over swept source OCT regarding axial resolution as shown in Fig. 1. With spectral domain OCT, ophthalmic imaging with axial resolutions down to ~2µm has been demonstrated [6]. While this might not be required for the diagnosis of most diseases, the diagnosis of some pathologies where individual cell layers are affected might benefit [7]. The purpose of this research is to push the axial resolution of swept source OCT. Here, we achieve axial resolutions of 5-7µm comparable to typical clinical systems but with a MHz-OCT system. In a first step, we increased the bandwidth of our swept laser source the FDML laser. Recent technical advances of semiconductor optical amplifiers (SOAs) and chirped fiber Bragg gratings (cfbgs) enabled us to double the sweep range from 72nm to up to 143nm. Then we investigate challenges related to such high sweep bandwidths.

Figure 1: Overview of imaging speed vs. axial resolution for selected OCT systems. The axial resolution is determined either by measuring the FWHM of the PSF of a mirror [6, 8-10] or a retinal structure[7]. 2. METHODS Figure 2 displays the schematics of our FDML-Laser [11]. FDML lasers exhibit the unique feature being capable of wavelength sweep repetition rates well into the MHz range [9, 12-18], because they do not suffer from inherent physical constraints with respect to wavelength sweep rate [19-23]. Hence, they found widespread applications from ultrafast OCT [24-28], over nondestructive sensing and testing [29-33] to optical molecular [34, 35] and functional imaging [36, 37] and even short laser pulse generation [38]. The extension of the accessible wavelength range of FDML lasers to the 1060nm spectral region [12, 17, 39-42] enabled high quality ultra-fast retinal swept source OCT imaging with good penetration into the choroid [9, 12, 17]. Compared to our previous version [9], we improved the gain bandwidth of our laser gain medium by 40nm through incorporating a newly developed SOA from Innolume (SOA-1020-110-HI-27dB). Together with a homebuilt fiber Fabry- Perrot filter achieving a free spectral range of over 180nm at a hardware resonance frequency of 417 khz, we could tune over a spectral bandwidth of 143nm. To make use of this broader sweep range and still have low noise and stable operation of our FDML laser, we had to compensate the intra-cavity dispersion for this increased spectral bandwidth. We achieved this by two measures. Firstly, by designing and implementing cfbgs (manufactured by Teraxion) to remove the main mismatch in roundtrip time for different wavelengths. And secondly, by minimizing the remaining dispersion with an optimized combination of fiber types with different dispersion characteristics. Figure 3 shows the extended sweep ranges of 143nm and 120nm at 417kHz and 1.67MHz, respectively. We apply a buffering scheme for the 1.67 MHz laser where the current of the SOA gain medium has to be modulated rapidly. We assume that the lower sweep range with buffering is due to a too low modulation bandwidth of the used laser diode controller (Wieserlabs WL- LDC10D). The point spread function (PSF) was measured with the reference and recalibration arm of our Michelson interferometer at 1.67MHz sweep rate and 120nm bandwidth. Data acquisition was performed with an Alazar Tech ATS9360 digitizer card at 1.8GS/s and a sampling depth of 12bit. This results in an imaging range of 2.1mm. For in vivo imaging in humans, we used

our standard MHz imaging setup as presented in [43]. The scanning protocol included 1900 A-scans per B-scan and a B-scan density of 1 B-scan/6µm. The latter matches the axial resolution of 7.5µm (FWHM) quite well. Figure 2: Schematic of our FDML laser and optional buffer stage: AWG: Arbitrary waveform generator, LCD: Laser diode controller, ISO: optical isolator, PC: polarization controller, BFP-TF: Fabry-Pérot filter, OSA: Optical spectrum analyzer, PD: photo diode. Intensity [db] -20-30 -40-50 -60-70 143nm 120nm 417 khz 1.67 MHz -80 960 1000 1040 1080 1120 Wavelength [nm] Figure 3: Spectra of the new FDML laser at 417kHz and at 1.67MHz sweep rate.

3. RESULTS AND DISCUSSION Figure 4 shows the results of the PSF measurement. The PSF has a FWHM of 7.4µm (in air) which corresponds to 5.6µm in tissue with a refractive index of ~1.3. Figure 4: PSF of a mirror at 800µm imaging depth. The FWHM is 7.4µm in air. This corresponds to an axial resolution of 5.6µm in tissue. A healthy volunteer was imaged to test the imaging capabilities of the new FDML design. We used an incident power of 1.6mW. In order to compare the new results with our previous lower bandwidth design, we imaged at 120nm sweep bandwidth and at 70nm.The results are displayed in Figure 5. Although, the images look quite similar at a first glance, a higher level of detail in the choricapillaris and fine vessels in the upper layers is obvious in the magnified images. The FWHM of a specular reflex was 6.0µm, which corresponds very well with the PSF measured from a mirror. For a more detailed investigation of the axial resolution- which is determined by the width and shape of the spectrum of our swept source laser-we measured the output spectrum at various positions in our setup with an optical spectrum analyzer: Directly at the FDML laser, after the booster SOA and at the photodetector of the interferometer after passing 4cm of water. The results are displayed in Figure 6. Next, we Fourier transformed the spectra in order to get the theoretically possible axial resolution by measuring the FWHM of each FFT. With the spectrum directly from the FDML laser, we get a FWHM of 4.9µm (in tissue, as for all following), after the light is amplified by the booster SOA a FWHM 5.3µm was determined. In order to simulate imaging of the human retina, we added a 2cm cuvette of water to our sample arm and measured the spectrum directly at the photodetector of our interferometer. The FFT showed a possible resolution of 5.9µm, which is very close the 6.0µm measured directly in the image. As shown in Figure 7, the water absorption in the eye varies strongly over the whole sweep range, which explains the change in spectrum and reduction of axial resolution [44].

Figure 5: 4 times averaged B-Scan of a heathy volunteer at 120nm and at 70nm sweep bandwidth. Magnifications of the boxed sections are shown below. Figure 6 top row: Spectra measured directly at the FDML laser, after the booster SOA and at the photodetector of the interferometer after passing 4cm of water. Bottom row: FFT transformation of each spectrum with FWHM in tissue.

Considering the resolution values we achieved only resolution levels comparable to standard commercial spectral domain OCT, so right now the system has no ultra-high resolution, yet. Considering the FFT of a Gaussian shaped spectrum with 120nm at 1050nm center wavelength the axial resolution is 3µm. However, as can be seen the 3dB bandwidth of our spectrum is much smaller, especially considering the effective spectrum after water absorption. Therefore, we believe that there is still potential for improving the axial resolution by spectral shaping by modulating the current of the SOA [45, 46] or an optical filter [47]. 0.8 water absorption absorption (1/cm) 0.6 0.4 0.2 G.M. Hale et al., Appl. Opt. 12 (1973),555-563 0.0 800 850 900 950 1000 1050 1100 1150 lambda (nm) Figure 7: Absorption of water in the near infrared [48]. 4. CONCLUSION AND OUTLOOK We demonstrated new record high bandwidths of 143nm and 120nm at 417 khz and 1.67 MHz A-scan rate of a swept laser source at ~1µm center wavelength. The benefits of the higher bandwidth were shown in in vivo human retinal OCT imaging, where the visibility of vascular structures was enhanced. An axial resolution of 6.0µm could be measured by determining the FWHM a specular reflex in an in vivo image. This is within the range of typical resolutions for commercial OCT systems, but at MHz speed. Improvements regarding the spectral shape should improve axial resolution and therefore image quality even further. Moreover, we plan to use a laser diode controller with a higher modulation bandwidth in order to achieve a higher sweep bandwidth for the buffered operation. Our results indicate that swept source retinal MHz-OCT with ultra-high resolution is feasible and provides detailed and rapidly acquired OCT images for better diagnosis REFERENCES [1] R. J. Zawadzki, S. M. Jones, S. S. Olivier et al., Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging, Optics Express 13(21), 8532-8546 (2005). [2] O. P. Kocaoglu, T. L. Turner, Z. Liu et al., Adaptive optics optical coherence tomography at 1 MHz, Biomedical Optics Express 5(12), 4186-4200 (2014). [3] S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, Optical coherence tomography using a frequency-tunable optical source, Optics Letters 22(5), 340-342 (1997).

[4] B. Golubovic, B. E. Bouma, G. J. Tearney et al., Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser, Optics Letters 22(22), 1704-1706 (1997). [5] S. H. Yun, G. J. Tearney, J. F. de Boer et al., High-speed optical frequency-domain imaging, Optics Express 11(22), 2953-2963 (2003). [6] M. Wojtkowski, V. Srinivasan, T. Ko et al., Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation, Optics Express 12(11), 2404-2422 (2004). [7] W. Drexler, U. Morgner, R. K. Ghanta et al., Ultrahigh-resolution ophthalmic optical coherence tomography, Nature medicine 7(4), 502-507 (2001). [8] I. Grulkowski, J. J. Liu, B. Potsaid et al., Retinal, anterior segment and full eye imaging using ultrahigh speed swept source OCT with vertical-cavity surface emitting lasers, Biomedical Optics Express 3(11), 2733-2751 (2012). [9] T. Klein, W. Wieser, L. Reznicek et al., Multi-MHz retinal OCT, Biomedical Optics Express 4(10), 1890-1908 (2013). [10] B. Potsaid, B. Baumann, D. Huang et al., Ultrahigh speed 1050nm swept source / Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second, Optics Express 18(19), 20029-20048 (2010). [11] R. Huber, M. Wojtkowski, and J. G. Fujimoto, Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography, Optics Express 14(8), 3225-3237 (2006). [12] T. Klein, W. Wieser, C. M. Eigenwillig et al., Megahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser, Optics Express 19(4), 3044-3062 (2011). [13] L. Reznicek, T. Klein, W. Wieser et al., Megahertz ultra-wide-field swept-source retina optical coherence tomography compared to current existing imaging devices, Graefes Archive for Clinical and Experimental Ophthalmology 252(6), 1009-1016 (2014). [14] W. Wieser, B. R. Biedermann, T. Klein et al., Multi-Megahertz OCT: High quality 3D imaging at 20 million A- scans and 4.5 GVoxels per second, Optics Express 18(14), 14685-14704 (2010). [15] W. Wieser, T. Klein, D. C. Adler et al., Extended coherence length megahertz FDML and its application for anterior segment imaging, Biomedical Optics Express 3(10), 2647-2657 (2012). [16] W. Wieser, W. Draxinger, T. Klein et al., High definition live 3D-OCT in vivo: design and evaluation of a 4D OCT engine with 1 GVoxel/s, Biomedical Optics Express 5(9), 2963-2977 (2014). [17] T. Klein, R. Andre, W. Wieser et al., Joint aperture detection for speckle reduction and increased collection efficiency in ophthalmic MHz OCT, Biomedical Optics Express 4(4), 619-634 (2013). [18] T. Wang, W. Wieser, G. Springeling et al., Intravascular optical coherence tomography imaging at 3200 frames per second, Optics Letters 38(10), 1715-1717 (2013). [19] R. Huber, M. Wojtkowski, K. Taira et al., Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles, Optics Express 13(9), 3513-3528 (2005). [20] B. R. Biedermann, W. Wieser, C. M. Eigenwillig et al., Dispersion, coherence and noise of Fourier domain mode locked lasers, Optics Express 17(12), 9947-9961 (2009). [21] C. Jirauschek, B. Biedermann, and R. Huber, A theoretical description of Fourier domain mode locked lasers, Optics Express 17(26), 24013-24019 (2009). [22] S. Todor, B. Biedermann, R. Huber et al., Balance of physical effects causing stationary operation of Fourier domain mode-locked lasers, Journal of the Optical Society of America B-Optical Physics 29(4), 656-664 (2012). [23] S. Todor, B. Biedermann, W. Wieser et al., Instantaneous lineshape analysis of Fourier domain mode-locked lasers, Optics Express 19(9), 8802-8807 (2011). [24] D. C. Adler, Y. Chen, R. Huber et al., Three-dimensional endomicroscopy using optical coherence tomography, Nature Photonics 1(12), 709-716 (2007). [25] C. Blatter, J. Weingast, A. Alex et al., In situ structural and microangiographic assessment of human skin lesions with high-speed OCT, Biomedical Optics Express 3(10), 2636-2646 (2012). [26] M. Bonesi, H. Sattmann, T. Torzicky et al., High-speed polarization sensitive optical coherence tomography scan engine based on Fourier domain mode locked laser, Biomedical Optics Express 3(11), 2987-3000 (2012).

[27] M. Gora, K. Karnowski, M. Szkulmowski et al., Ultra high-speed swept source OCT imaging of the anterior segment of human eye at 200 khz with adjustable imaging range, Optics Express 17(17), 14880-14894 (2009). [28] T. Klein, W. Wieser, B. R. Biedermann et al., Raman-pumped Fourier-domain mode-locked laser: analysis of operation and application for optical coherence tomography, Optics Letters 33(23), 2815-2817 (2008). [29] D. C. Adler, J. Stenger, I. Gorczynska et al., Comparison of three-dimensional optical coherence tomography and high resolution photography for art conservation studies, Optics Express 15(24), 15972-15986 (2007). [30] D. C. Adler, R. Huber, and J. G. Fujimoto, Phase-sensitive optical coherence tomography at up to 370,000 lines per second using buffered Fourier domain mode-locked lasers, Optics Letters 32(6), 626-628 (2007). [31] W. Wieser, B. R. Biedermann, T. Klein et al., Ultra-rapid dispersion measurement in optical fibers, Optics Express 17(25), 22871-22878 (2009). [32] L. A. Kranendonk, X. An, A. W. Caswell et al., High speed engine gas thermometry by Fourier-domain modelocked laser absorption spectroscopy, Optics Express 15(23), 15115-15128 (2007). [33] L. A. Kranendonk, R. Huber, J. G. Fujimoto et al., Wavelength-agile H2O absorption spectrometer for thermometry of general combustion gases, Proceedings of the Combustion Institute 31, 783-790 (2007). [34] C. Blatter, B. Grajciar, P. Zou et al., Intrasweep phase-sensitive optical coherence tomography for noncontact optical photoacoustic imaging, Optics Letters 37(21), 4368-4370 (2012). [35] S. Karpf, M. Eibl, W. Wieser et al., A Time-Encoded Technique for fibre-based hyperspectral broadband stimulated Raman microscopy, Nat Communications 6, (2015). [36] D. C. Adler, S.-W. Huang, R. Huber et al., Photothermal detection of gold nanoparticles using phase-sensitive optical coherence tomography, Optics Express 16(7), 4376-4393 (2008). [37] C. Blatter, T. Klein, B. Grajciar et al., Ultrahigh-speed non-invasive widefield angiography, Journal of Biomedical Optics 17(7), (2012). [38] C. M. Eigenwillig, W. Wieser, S. Todor et al., Picosecond pulses from wavelength-swept continuous-wave Fourier domain mode-locked lasers, Nature Communications 4, (2013). [39] S. Marschall, T. Klein, W. Wieser et al., Fourier domain mode-locked swept source at 1050 nm based on a tapered amplifier, Optics Express 18(15), 15820-15831 (2010). [40] C. M. Eigenwillig, T. Klein, W. Wieser et al., Wavelength swept amplified spontaneous emission source for high speed retinal optical coherence tomography at 1060 nm, Journal of Biophotonics 4(7-8), 552-558 (2011). [41] V. J. Srinivasan, R. Huber, I. Gorczynska et al., High-speed, high-resolution optical coherence tomography retinal imaging with a frequency-swept laser at 850 nm, Optics Letters 32(4), 361-363 (2007). [42] T. Torzicky, S. Marschall, M. Pircher et al., Retinal polarization-sensitive optical coherence tomography at 1060 nm with 350 khz A-scan rate using an Fourier domain mode locked laser, Journal of Biomedical Optics 18(2), (2013). [43] J. P. Kolb, T. Klein, C. L. Kufner et al., Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle, Biomedical Optics Express 6(5), 1534-1552 (2015). [44] S. Hariri, A. A. Moayed, A. Dracopolos et al., Limiting factors to the OCT axial resolution for in-vivo imaging of human and rodent retina in the 1060nm wavelength range, Optics Express 17(26), 24304-24316 (2009). [45] A. C. Akcay, J. P. Rolland, and J. M. Eichenholz, Spectral shaping to improve the point spread function in optical coherence tomography, Optics Letters 28(20), 1921-1923 (2003). [46] S. Marschall, C. Pedersen, and P. E. Andersen, Investigation of the impact of water absorption on retinal OCT imaging in the 1060 nm range, Biomedical Optics Express 3(7), 1620-1631 (2012). [47] B. R. Biedermann, W. Wieser, C. M. Eigenwillig et al., Real time en face Fourier-domain optical coherence tomography with direct hardware frequency demodulation, Optics Letters 33(21), 2556-2558 (2008). [48] G. M. Hale, and M. R. Querry, OPTICAL-CONSTANTS OF WATER IN 200-NM TO 200-MUM WAVELENGTH REGION, Applied Optics 12(3), 555-563 (1973).