Datasheet. MX2020/SSI Signal Simulator Interface. Overview. Features and Benefits

Similar documents
SP-2020/SSI Signal Simulator Interface

ST6911 IPT ACCELERATION VIBRATION TRANSDUCER ST6917 IPT VELOCITY VIBRATION TRANSDUCER Installation Manual

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Low Frequency Velocity Sensor

User Guide. Version 1.0 POWER

Universal audio/midi interface USER MANUAL

Shaft Absolute Vibration Monitor Specifications

PROGNOST -SenSim Sensor signal simulation instead of stimulation. 2ooX. Voting schemes. static and dynamic signal simulation

3500/40M Proximitor Monitor

Portable Audio interface for ios, USB USER MANUAL

ST5484E-SW Compact Configurable Vibration Switch Installation Manual

Additel 875 Series Dry Well Calibrators

irig Mic Field Stereo audio/video microphone USER MANUAL

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

Additel 875 Series Dry Well Calibrators

Torque Sensor Accessories and Services

Non-Submersible Industrial Pressure Transducer

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

the 3500/44M Aeroderivitive GT Vibration Monitor for the

Speed and Key Monitor Specifications

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Lavalier microphone for smartphones USER MANUAL

VMS 830. Vibro-Meter Vibration Monitor FEATURES GENERAL. Absolute vibration measurement. Monitoring of machines and industrial plants

TD-1 Tone Decoder / Trigger Version 1.0

Troubleshooting accelerometer installations

Sensors for Vibration, Acceleration, and Shock Measurement. Product Catalog

VM-701B VIBRATION / DISPLACEMENT MONITOR MODULE Page 1 of 7

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

COMPACT MOLECULAR-ELECTRONIC SEISMIC SENSORS

Product Information. ECN 1313 ECN 1325 ERN 1387 Rotary Encoders with Plane-Surface Coupling for Elevator Servo Drive Control

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

User s Manual For PAMS. Portable Attenuation Measurement System /

Applications Note. Bently Nevada* Asset Condition Monitoring. Periodically Monitored Assets. Connecting SCOUT to Continuous Monitoring Systems

Condition Monitoring Custom Products

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

PowerLink Speaker Adaptor. User Manual

4830B accelerometer simulator Product overview

SCXI Terminal Block

CONTENTS. User Manual

Load Cell Accessories and Services

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

Trendmaster * Dynamic Scanning Module

45EMD Portable Calibrator User Manual

LT3000 ULTRASONIC LEVEL TRANSMITTER

TXR/TXA TRENDSETTER Datasheet

PSL - Power Sensors Ltd

REV A.1 CMCP810PC SERIES RUNOUT KIT INSTRUCTION MANUAL STI VIBRATION MONITORING INC

1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

CSI 9330 Vibration Transmitter

9330 Vibration Transmitter

VIBXPERT. 2-Channel Vibration Analyzer. 102,400 lines of resolution. Weighs only 2.2 lbs. Simple joystick operation. Signal post processing

Stratus 2i Installation Guide. Revision 2.0

Model 25B-F/S/L Solid Shaft Low Line Incremental Optical Rotary Encoder

Rotary Measuring Technology

Sensor Portfolio for Machinery Health Applications

HI-913 HARDY SHAKER Installation Manual

Signal Conditioning Amplifier

Stereo 3.7W Class D Audio Amplifier

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

25 velocity-sensitive mini-keys keyboard USER MANUAL

Motor Vibration. Detect Mechanical & Electrical Motor Faults with Vibration Monitoring Instrumentation. IMI Sensors - A PCB Piezotronics Division

VIBRATION SENSOR WITH TWO-WIRE INTERFACE AND BIAS USED FOR MEASURE TEMPERATURE

Industrial Monitoring Instrumentation

1510A PRECISION SIGNAL SIMULATOR

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

What are we looking at?

Product Specifications

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395

Series GLET Accessory for dataloggers series GL in modular enclosure

ACCUMEASURE. Non-contact Capacitance Position Measurement with Nanometer Accuracy. A worldwide leader in precision measurement solutions

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder

41P Portable Calibrator User Manual

LAUREL ELECTRONICS, INC.

Two Channel Mic & Guitar Interface with Lightning Connector for ios Devices

LKAT2 Portable. High Current, Portable, Multi-size Head AC / DC Current Measurement System. Application Examples. Key Features

PCX-9000 Series Datasheet

3500/64M Dynamic Pressure Monitor

Product Information. ECN 413 ECN 425 ERN 487 Rotary Encoders for Elevator Drive Control (IP64 Degree of Protection)

NOVOTURN Multiturn Sensor non-contacting. Series RSM-2800

Dytran Instruments, Inc. 1

Flexible Functionality

Features. Applications

Technical data. General specifications V DC Power consumption P 0. 1 W Time delay before availability t v

Digital Room Sensor Technical Guide

Compact Signal Calibrator

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Product Specifications

Compact Signal Calibrator

MPR kHz Reader

SKF Multilog On-line System DMx

BOOTH #1735 GMF Music Product Catalog (2017)

ASC IMU 7.X.Y. Inertial Measurement Unit (IMU) Description.

Rotary Measuring Technology

Microwave outdoor intrusion detection sensor

Exercise 1: AC Waveform Generator Familiarization

BUILDING INSTALLATIONS AND ELECTRICAL SYSTEMS

Transcription:

Datasheet MX2020/SSI Signal Simulator Interface Overview The Signal Simulator Interface (SSI) allows easy connection of a signal generator to a vibration monitoring module for simulating up to two channels of dynamic vibration. The SSI also provides DC offset 1 adjustment from -2V to -22V, used for simulating static measurements that rely on changes in gap or bias voltage, such as axial thrust position and sensor OK limits. A standard 3.5mm stereo headphone jack connects the SSI to a single- or dual-channel signal generator. 2 A composite signal consisting of the DC bias voltage and the AC waveform will be output from the SSI, simulating the signal from a proximity probe, accelerometer, or velocity transducer. Each composite signal is supplied to the vibration monitor using the included cable. The standard cable supplied with the SSI terminates in a connector used for a SETPOINT Universal Monitoring Module (UMM) 3. The UMM connector may be easily removed, allowing the cable to interface to vibration monitor types from other manufacturers. Combined, the SSI and a signal generator allow testing and verification of numerous monitoring system functions such as vibration amplitude measurement, position measurement, alarm limits, OK limits, alarm delays, alarm voting logic, Timed OK channel defeat, latching and non-latching alarm types, channel filter response, signal integration, gap voltage measurement, and many others. The SSI obtains all necessary power directly from the its connected vibration monitor and does not require a battery or other external power source. For an affordable and highly compact signal generator solution, Metrix recommends the use of an ipod Touch, iphone, or ipad device running Audio Artillery s Sig Gen app. Connect the Headphone Out jack on the idevice to the SIG jack on the SSI using the included SIG cable. 4 Features and Benefits Works Great with ipod, iphone, or ipad Although the SSI will work with any signal generator or AC signal source, it is especially convenient when used with an Apple ipod Touch or iphone due to the diminutive size and portability of a 2-CH signal generator that fits in your pocket. Document 1095333

Mistake-Proof All inputs/outputs on the SSI are clearly labeled, connectors are keyed, and cables are preassembled to ensure no wiring or connection mistakes occur. Affordable Most signal generators, regardless of price, provide only ± 5 V of DC offset adjustment. And, even the least expensive 2-CH function generators cost in excess of $500. In contrast, the SSI solution is inexpensive while delivering the necessary range of DC offset adjustment. When coupled with a very affordable 8GB ipod Touch ($199 US) and the Sig Gen app (just $2.99 from the Apple App Store), the result is a complete 2-CH vibration signal simulator solution with adjustable waveform type, amplitude, frequency, phase, and full gap voltage offset range for around $200 US. And, if you already own an iphone, ipod Touch, or ipad, your only expense is the minimal cost of the Sig Gen app. Capable The SSI can be used to simulate outputs from thrust probes, radial vibration probes, seismic sensors, and phase reference probes. This makes it extremely handy for conducting loop checks and other system verification tasks. 5 NOTES: 1. Most commercially available signal generators are capable of supplying a DC offset of only +/- 5 V. This is not sufficient to simulate the full range of typical thrust position measurements or transducer OK limits. The SSI permits simulation of such measurements by providing -2Vdc to -22Vdc of offset adjustment. 2. When a single-channel signal generator is used, a composite AC/DC signal will only be available from channel 1 of the SSI. DC gap voltage adjustment will still be available for channel 2, but no AC signal will be present. 4. The SIG cable has a 3.5mm stereo male plug on each end. 5. While surprisingly accurate, the Sig Gen app and corresponding ipad/iphone/ipod hardware is not suitable for system calibration tasks that require traceability to a reference standard. Specifications All specifications subject to change without notice. Power Channels Channel Adjustment Range Dimensions (L x W x D) Cable Type Cable Length Weight (including cables) -24Vdc (supplied by UMM) Two Gap: -2 Vdc to -22 Vdc AC signal: Adjusted via external signal source, such as ipod running Sig Gen app. Components in SSI limit total signal amplitude (AC + gap) to ±24 V. 3.97 x 2.02 x 1.65 (100.9 x 51.4 x 41.9 mm) UMM: Alpha wire 1774C or equal (22 AWG, 4 conductors, PVC jacket). Standard 4-pin DIN connector (male) to 16-terminal UMM connector. SIG: 24AWG, 3 conductors, shielded; 3.5mm male stereo plug both ends UMM: 36 (914 mm) SIG: 72 (1829 mm) 0.5 lbs (227 g) Temperature -10 to + 210 F (-23 to +99 C) Certifications None. Designed for temporary, indoor use only as part of demonstrations. Not for use as part of a permanent machinery protection installation. Manufacturer Metrix 3. This cable has a 4-pin DIN connector on one end and a standard UMM 16-terminal connector on the other end. Document 1095333 Datasheet MX2020/SSI Signal Simulator Interface Page 2 of 5

Ordering Information SETPOINT MPS Signal Simulator Interface (SSI) NOTE: Signal generator, ipod, iphone, or ipad device and Sig Gen software supplied separately and must be ordered directly from their respective manufacturers. MX2020/SSI-AA-BB SETPOINT Signal Simulator Interface (SSI) AA UMM cable length (in feet) 0 0 No UMM cable 0 3 3 UMM cable BB SIG cable length (in feet) 0 0 No SIG cable 0 6 6 SIG cable Ordering Information Spare Cables These cables are supplied with the SSI and do not need to be ordered separately except as spares for lost or damaged cables. 100529-AA SSI UMM Cable (4-pin DIN male to UMM input terminal block) AA Cable length (in feet) 0 3 3 cable 100531-AA SSI SIG Cable (3.5mm stereo audio male, both ends) AA Cable length (in feet) 0 6 6 cable Connection Diagrams Special 36 pre-assembled cable (not shown) goes to CH 1 and CH 2 of UMM. Uses -24Vdc power from UMM (no batteries or separate power required). Cable is removable for easy transport. 4-pin DIN on one end, standard 16-terminal UMM connector on other end. Signal Simulator Interface (SSI) Rotary pots independently adjust gap voltage on CH 1 and CH2. Used for simulating axial thrust position and probe NOT OK conditions. Standard 3.5mm stereo audio cable routes signal from ipod (or other function generator) into SSI. Sig Gen app by Audio Artillery allows ipod/iphone/ipad to act as a 2-channel function generator. User selects waveform type for each channel, amplitude in V pp, frequency (Hz), and relative phase between channels. Signal is output via headphone jack. Document 1095333 Datasheet MX2020/SSI Signal Simulator Interface Page 3 of 5

To single- or dual-channel signal generator To single- or dual-channel signal generator SSI #1 Drives UMM channels 1 and 2 SSI #2 (optional) Drives UMM channels 3 and 4 Document 1095333 Datasheet MX2020/SSI Signal Simulator Interface Page 4 of 5

Metrix Instrument Company 8824 Fallbrook Drive Houston, TX 77064 USA (281) 940-1802 www.metrixsetpoint.com info@metrixsetpoint.com Trademarks used herein are the property of their respective owners. Data and specifications subject to change without notice. 2011 Metrix Instrument Company, L.P. Document 1095333 Datasheet MX2020/SSI Signal Simulator Interface Page 5 of 5