MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Similar documents
MACX MCR-EX-SL-RPSSI-I

MCR-C-UI-UI-DCI. Extract from the online catalog. Order No.:

Signal conditioner - MACX MCR-UI-UI-NC

PSR-SCP- 24DC/ESD/5X1/1X2/300

Extract from the online catalog

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

DEK-OV- 12DC/ 24DC/ 3

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

Temperature Input Module for Zone 1 Series 9482/32

AKG 4 GNYE. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-I-LP-NC

UTTB 4. Extract from the online catalog. Order No.:

Isolators A3/1. Vibration Transducer Supply Unit Series

UTTB 2,5. Extract from the online catalog. Order No.:

MC 1,5/ 4-ST-3,5. Extract from the online catalog. Order No.:

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

SMKDSP 1,5/ 8. Extract from the online catalog. Order No.:

KDS10/SO. Extract from the online catalog. Order No.:

SLKK 5. Extract from the online catalog. Order No.:

MACX MCR-UI-UI-UP(-SP)(-NC)

Safety relays - PSR-SCP- 24DC/ESD/4X1/

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

High-current terminal block - UKH

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Assembly. Front view. Parametrization interface. Power Bus

MKDSN 1,5/ 4-5,08. Extract from the online catalog. Order No.:

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

KDSP 4. Extract from the online catalog. Order No.:

MKKDSH 3/ 2. Extract from the online catalog. Order No.:

Technical Data. General specifications. Rated operating distance s n 3 mm

FRONT 2,5-H/SA 5. Extract from the online catalog. Order No.:

MKDS 3/ 4. Extract from the online catalog. Order No.:

SMKDS 2,5/ 2-5,08. Extract from the online catalog. Order No.:

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Rail mounted Temperature Transmitter TH102/TH102-Ex

Binary Output Series 9175

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

Binary Output without Power Supply Series 9176

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

MVSTBR 2,5/ 2-ST. Extract from the online catalog. Order No.:

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

MSTB 2,5/ 4-ST. Extract from the online catalog. Order No.:

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

MVSTBW 2,5/ 5-ST. Extract from the online catalog. Order No.:

Analog Universal Module HART for Zone 2 Series 9468/33

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Technical Information RMA42

Temperature transmitter itemp PCP DIN rail TMT 121

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

0 2 1 â Ó. itemp HART TMT182. Technical Information

Assembly. Front view. HiC2441. SL2 1b. Termination Board

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

itemp HART DIN rail TMT112

MSTB 2,5/ 3-ST. Extract from the online catalog. Order No.:

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

RMA42. Technical Information

D5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data:

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Two-channel safety barriers Series 9002

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Digital Input Output Module for Zone 2 Series 9470/33

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

Two-channel safety barriers Series 9002

Isolating Repeater Input Series 9163

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

0 2 1 â Ó. itemp HART TMT182. Technical Information

MCR-T-UI(/NC) MCR-T-UI-E(/NC)

Digital Input Output Module for Zone 1 Series 9470/32

MODEL: R30US4. Remote I/O R30 Series

Digital indicator for panel mounting With multi-function input Model DI25

FC Series Signal Conditioners

Universal Intelligent 2-wire DIN Rail Transmitters

QUINT-PS-24DC/24DC/10

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

SINEAX TI 807 Passive DC signal isolator

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Technical Information Barrier RB223

Temperature head transmitter itemp PCP TMT 181

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Temperature Transmitter itemp RTD DIN rail TMT 127

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Transcription:

Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, galvanic isolation, widerange power supply, screw connection, SIL Commercial data EAN 4 046356 296670 Product notes WEEE/RoHS-compliant since: 08/04/2011 Pack 1 Customs tariff 85437090 Product key 09724 Country of Origin DE Catalog page information Page 452 (IF-2011) Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http:// www.download.phoenixcontact.com. The General Terms and Conditions of Use apply to Internet downloads. Technical data Input data Sensor types (RTD) that can be used Sensor types that can be used (TC) Pt, Ni, Cu sensors: 2, 3, 4-wire B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG

Input signal range Potentiometer resistance range Input signal range 0 Ω... 50 kω 0 Ω... 50 kω -1000 mv... 1000 mv Output data Max. voltage output signal Current output signal Max. current output signal Load/output load voltage output Load/output load current output Behavior in the event of a sensor error Output name Contact type Contact material Maximum switching voltage Maximum inrush current Mechanical service life ± 11 V 4 ma... 20 ma (in the case of SIL; further free configuration without SIL) 22 ma 10 kω 600 Ω (at 20 ma) According to NE 43 or freely configurable Switching output 1 PDT AgSnO 2, hard gold-plated 30 V AC (30 V DC) 0.5 A (30 V AC) 1 A (30 V DC) 1 x 10 5 cycles Power supply Supply voltage range Typical current consumption Power consumption 24 V... 230 V AC/DC (-20%/+10%, 50/60 Hz) < 50 ma (24 V DC) < 1.5 W Connection data Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 14 Stripping length 7 mm Screw thread M3 Connection method Screw connection Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm

General data Maximum transmission error Maximum temperature coefficient 0.1 % (E.g., at PT 100, 200 K min. span) 0.01 %/K Ambient temperature (operation) -20 C... 65 C Ambient temperature (storage/transport) -40 C... 85 C Permissible humidity (operation) Step response (0 99%) Status display Width Height Depth Inflammability class according to UL 94 Pollution degree 2 Surge voltage category Typ. 5 %... 95 % (no condensation) Typ. 1000 ms (With SIL) Typ. 700 ms (Without SIL) Green LED (supply voltage, PWR) Red LED, flashing (line, sensor error, ERR) Red LED (module error, ERR) Yellow LED (switching output) 17.5 mm 99 mm 114.5 mm Shock 15g, according to IEC 60068-2-27 Vibration (operation) 5 g, in accordance with IEC 60068-2-6 Housing material Degree of protection Color Electrical isolation V0 II PA 66-FR IP20 green 4-way, between input/output/power supply/switching output Electrical isolation input / output 375 V (Peak value in accordance with EN 60079-11) Electrical isolation input / supply 375 V (Peak value in accordance with EN 60079-11) Electrical isolation of input/switching output 375 V (Peak value in accordance with EN 60079-11) Electrical isolation output / supply Conformance ATEX IECEx Functional safety (SIL) SIL 2 300 V rms (Rated insulation voltage, surge voltage category II; pollution degree 2, safe isolation as per EN 61010, EN 50178) CE-compliant Ex II (1) G [Ex ia] IIC Ex II (1) D [Ex iad] Ex II 3 G Ex nac ic IIC / IIB / IIA T4 X [Ex ia] IIC; [Ex iad]; Ex nac IIC T4 X

Safety data Max. voltage U o Max. current I o Max. power P o 6 V 7.4 ma 11 mw 100 mh Max. external capacity C o 1.3 µf 10 mh Max. external capacity C o 1.7 µf 1 mh Max. external capacity C o 2.6 µf 110 mh Max. external capacity C o 6.8 µf 10 mh Max. external capacity C o 9.2 µf 1 mh Max. external capacity C o 15 µf Safety-related maximum voltage U m 253 V AC (125 V DC) Certificates Certification Ex: IECEx

Drawings Block diagram