Glued laminated timber beams repair.

Similar documents
LOAD CARRYING CAPACITY OF METAL DOWEL TYPE CONNECTIONS OF TIMBER STRUCTURES

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Mechanical behavior of fiberglass reinforced timber joints

SCREWS WITH CONTINUOUS THREADS IN TIMBER CONNECTIONS

EVALUATION OF THE STRUCTURAL BEHAVIOUR OF BEAM-BEAM CONNECTION SYSTEMS USING COMPRESSED WOOD DOWELS AND PLATES

Comparison of behaviour of laterally loaded round and squared timber bolted joints

European Technical Assessment ETA-17/1005 of

Pull-compression tests on glued-in metric thread rods parallel to grain in different timber species and laminated veneer lumber

CLT Cross Laminated Timber

Lawrence A. Soltis, M. and Robert J. Ross, M. 1

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

European Technical Assessment. ETA-16/0902 of 17 March English translation prepared by DIBt - Original version in German language.

Verbindungselemente Engel GmbH Weltestraße Weingarten DEUTSCHLAND. Manufacturing plant 74437, , ,

European Technical Approval ETA-12/0114

Investigations on the Effectiveness of Self-tapping Screws in Reinforcing Bolted Timber Connections

REISSER-Schraubentechnik GmbH Fritz-Müller-Straße Ingelfingen-Criesbach DEUTSCHLAND

nineteen Wood Construction 1 and design APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2016 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Dowel-type fasteners. Timber Connections. Academic resources. Introduction. Deferent types of dowel-type fasteners. Version 1

Korean standards of visual grading and establishing allowable properties of softwood structural lumber

Load carrying capacity of dowelled connections

Butt Two pieces of wood meeting with flat sides adjoining usually at right angles. Some type of connector is needed to prevent movement.

European Technical Assessment ETA-12/0197 of 12/07/2017

European Technical Assessment ETA-13/0029 of 11/07/2017

STRUCTURAL TIMBER DESIGN

Tensile strength of ASSY plus VG screws wood-wood (softwood)

Load-carrying capacity of timber frame diaphragms with unidirectional support

Attach Trusses and Rafters Faster

PRO LIGNO Vol. 11 N pp

European Technical Assessment ETA-11/0024 of 08/07/2016

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

Double Shear Testing of Bolts

European Technical Assessment ETA-11/0024 of 02/03/2017

T Wooden Structures 1

EXAMPLE 1-4 EXAMPLE 1-5

THE EFFECT OF THREAD GEOMETRY ON SCREW WITHDRAWAL STRENGTH

A STUDY ON PATTERN DAMAGE OF FINGER JOINTS IN BAMBOO LAMINATED BEAMS

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

European Technical Approval ETA-11/0024

European Technical Assessment. ETA-12/0373 of Member of. General part

AMTS STANDARD WORKSHOP PRACTICE. Bond Design

ALUMIDI. Concealed beam hanger with and without holes Aluminum alloy tridimensional perforated plate ALUMIDI - 01 CERTIFIED STEEL-ALUMINUM

WELDA FASTENING PLATES

Development of Wooden Portal Frame Structures with Improved Columns

M. Bücker*, M. Magin. Institute for Composite Materials, Erwin-Schrödinger-Straße 58, Kaiserslautern, Germany

European Technical Approval ETA-08/0165

Dowel connections in laminated strand lumber

SPECIFIC ENGINEERING DESIGN GUIDE

PERFORMANCE OF COMPOSITE SHEAR WALL PANEL OF LVL AND GRC BOARD

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

Derivation of Mechanical Properties of Rubberwood Laminated Veneer Lumber

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

English translation authorized by DIBt Original version in German language

HPD Aerated concrete anchor. Approvals / certificates. Basic loading data (for a single anchor)

EVALUATING ROLLING SHEAR STRENGTH PROPERTIES OF CROSS LAMINATED TIMBER BY TORSIONAL SHEAR TESTS AND BENDING TESTS

Combined stress analysis of mitered spline furniture joints under diagonal loading

Connection Solutions for Wood-frame Structures. Copyright Materials. Learning Objectives

Connection Philosophy. p NDS Chapter-by-chapter description Changes from previous editions Examples. Part 1: Member Design Webinar.

European Technical Approval ETA-07/0212

Improved Arcan Shear Test For Wood

Connection Design Examples

European Technical Assessment. ETA-15/0667 of Member of. General part

Österreichisches Institut für Bautechnik Schenkenstrasse Vienna Austria T F

Title. CitationJournal of Wood Science, 58(4): Issue Date Doc URL. Rights. Type. File Information.

Section 914. JOINT AND WATERPROOFING MATERIALS

HUS 6 Screw anchor, Redundant fastening

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

The Wood Products Council is a Registered Provider with. . Credit(s) earned on completion of this program will be

EVALUATION OF SCREWS USED IN LAMINATED VENEER LUMBER ROCKING CONNECTIONS

Anti-check bolts as means of repair for damaged split ring connections

Connections in CLT Assemblies

Available online at ScienceDirect. Procedia Engineering 114 (2015 )

Connection and performance of two-way CLT plates

ADDENDUM (February 2014) 2012 NDS Changes John Buddy Showalter, P.E., Bradford K. Douglas, P.E., Philip Line, P.E., and Peter Mazikins, P.Eng.

European Technical Approval ETA-11/0283

Joint analysis in wood trusses

Hans J. Blaß Professor Karlsruhe Institute of Technology Karlsruhe 76297, Germany

European Technical Approval ETA-13/0630

Erstantie 2, FIN Villähde Tel , Fax

VERSA-LAM. An Introduction to VERSA-LAM Products

Connection and Tension Member Design

STUDY OF PEEL AND SHEAR STRENGTH OF ADHESIVE JOINT BETWEEN PINE WOOD AND CFRP TAPE

Behaviour of fibre reinforced composite beams with mechanical joints

Internal threaded version: HSC-I carbon steel internal version HSC-IR Stainless steel version (A4) Hilti anchor design software

Effect of Vertical Load under Cyclic Lateral Load Test for Evaluating Sugi CLT Wall Panel

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

Ductility of large-scale dowelled CLT connections under monotonic and cyclic loading

THE ENGINEERED WOOD ASSOCIATION

The Influence of Nails and Plasterboard on the Racking Resistance of Stud Walls

Behaviour of tensile strength and displacement concerning Big Screw Joint with Cross Laminated Panel

Tension Perpendicular to Grain Strength of Wood, Laminated Veneer Lumber (LVL), and Cross-Banded LVL (LVL-C)

4.0 MECHANICAL TESTS. 4.2 Structural tests of cedar shingles

Load tables for a transport anchor system with Würth ASSY 3.0 combi self-tapping screws = 12 mm as defined under ETA-11/0190 (6/27/2013)

BauBuche Fasteners and connections

Load tables for a transport anchor system with Würth ASSY 3.0 combi self-tapping screws = 12 mm as defined under ETA-11/0190 (6/27/2013)

Timber Rivet Connections Design Process for a Hanger Connection

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

Design Nailed and Wood Screwed Connections with Spreadsheet. Course Content

WOODEN BUILDINGS 6.1 INTRODUCTION 6.2 TYPICAL DAMAGE AND FAILURE OF WOODEN BUILDINGS. Chapter 6

European Technical Approval ETA-10/0038

Transcription:

Glued laminated timber beams repair. Master s Degree Extended Abstract Ricardo Cardoso Henriques da Silva Keywords: glulam, delamination, self-tapping screw, plywood, repair November 2014

1. INTRODUCTION Glued laminated timber elements ate regularly used in construction. Their fabric method allows the possibility to obtain beams with a wide range of sizes and shapes. However, these elements are susceptible to the occurrence of delamination due to fabric errors such as an inadequate surface preparation of the lamellas (before collage) or incorrect glue amount used to bond the lamellas amongst other errors or bad design of the structure (loads, class services). The delamination of glued laminated timber beams decreases the load-carrying capacity of the beams, as well as their modulus of elasticity causing bigger deformations. This problem leads to an early failure of the glued laminated timber beams, being necessary to repair the structure. As the removal of timber elements is a very costly and time consuming option, on-site repair is a much more desirable approach towards to rehabilitate the structure. Previous studies have developed numerous techniques using self-tapping screw amongst other connections with metal fasteners, plates, and new materials Glass fiber-reinforced polymers (GFRP) and Carbon fiber-reinforced polymers (CFRP) to reduce costs and develop faster and simpler techniques. The main objective of this dissertation is to evaluate the effectiveness of a fast, simple and nonintrusive on-site repair of glued laminated beams with delamination, previously tested to failure. The repair in this dissertation was executed using self-tapping stainless steel screws applied vertically to the beams, with plywood plates. 2. MATERIALS AND METHODS 2.1. Experimental program A total of 21 industrial produced beams with 3,090m x 0,175m x 0,095m were tested, presenting intentionally various kinds of delamination: i) 3 beams without any type of delamination caller reference beams or A beams (A1 to A3); ii) 6 beams with short delamination reaching the totality of the cross-section glue lines in the edges of the beam with a 0,320m length value, called B beams (B1 to B6); iii) 6 beams with long delamination reaching the totality of the cross-section glue lines in the edges of the beam with a 0,720m length value, called C beams (C1 to C6); iv) 6 beams with delamination on all the glue lines reaching 2/3 of the cross-section width, in the whole length of the beam. The beams used in this experimental project were produced using cluster pine (Pinus pinaster, Ait.), with a moisture content of 14%, composed by 5 lamellas with a thickness of 3,5cm. Fig. 1 shows a scheme of the beams geometry, and Fig. 2 and Fig. 3 shows the delamination on beams B/C and D respectively. The experimental project involved the following beams: A1, A2, A3, B1, B3, B6, C1, C2, C3 and D1 to D6 (D3, D4 and D5 not repaired because these beams were used in another experiment). 1

L (m) 3,090 b (m) 0,095 h (m) 0,175 Figure 1. Beams geometry and dimensions L d = 0,32m (B) or L d = 0,72m (C) Figure 2. Delamination scheme of "B" and "C" beams (delaminations marked as thick black lines) Figure 3. Delamination scheme of D beams (delaminations marked as thick black lines) In order to achieve the proposed objectives, it was used the following experimental program: first the beams were submitted to a 4 point bending test, applying symmetric loads, in accordance with the European standard EN 408:2004 [1]; after the bending tests the beams were repaired according to the type of failure (shear or bending failure); then the repaired beams were submitted again to a 4 point bending test. The materials used in the beams repair were the following: self-tapping steel screws HBS10160 and HBS10240 provided by Rothoblaas illustrated in Fig. 4, and Okoumé plywood plates with 2,392m x 0,095m x 0,027m, provided by JULAR Madeiras. 2

Figure 4. Self-tapping screws HBS10240 (up) and HBS10160 (down) 2.2. Beams industrial fabric The beams used were manufactured in a specialized fabric and montage of glued laminated timber company, following the general proceedings in wood selection, surface preparation, collage, cramping pressure and curing [2, 3]. The collage of the lamellas was performed with a Melamine-Urea- Formaldehyde glue named KOMARTEX M provided by Colquímica. This glue was also used in the fabric of the finger-joints. To simulate real delamination in the glue lines tape was palces between the lamellas before they were glued together in order to prevent the adhesion between the lamellas ensuring the desired shape and dimension for the delamination with a natural proceeding instead using saw blades (introduces tension). This procedures was previously tested in laboratory, The beams were manufactures with a greater length that the desired one, allowing after the fabric of the beams to cut out about 20cm of the edges, rejecting the beam ends where is more difficult to assure an uniform cramping pressure. Fig. 5 shows the presence of tape between the lamellas in a tested beam (D6). Figure 5. Presence of tape between lamellas The glue line strength and integrity were evaluated through blocks shear tests and delamination tests, according to the respective standards [4] and [5], analysing the results and verifying if those results are in accordance with the requisites given by the standard EN 386:2001 [2]. These tests were performed at LNEC with industrial control equipment, and the specimens used were obtained from the removed edges of the A and D beams. Fig. 6 illustrates the specimens used in both tests (24 thinner specimens on the right used in the shear block tests, and the other 9 on the left used in the delamination tests). 3

Figure 6. Specimens used in delamination and shear blocks tests 2.3. Bending tests As written before, all the beams were submitted to a 4 point bending test performed at LNEC as descript in the standard EN 408:2004 [1], using six Linear Variable Differential Transformers (LVDTs) on the load application points, on the supports and two in the middle point on the beam (Figures 7 and 8). The equipment used was the following: load application machine of SHIMADZU CORPORATION, model AG-IS; six LVDTs; and a DataLogger of the RDP brand. Figure 7. Bending test (beam A1) Figure 8. LVDTs positioning in the bending tests [1] 4

2.4. Repair Design The beams repair design was perform and calculated so that the failure force of the repaired beams was equal to the average failure force obtained in the A beams (45kN). It was decided apply the same repair method to all the beams, with just slightly adjustments on the position of the reinforcement, according to the type of failure occurred. Fig. 9 shows the failures obtained in the tested beams, where the blue lines represent the failure lines, the black lines represent delamination, and the dark brown lines represent the glue lines. Figure 9.Failures occurred The repair method consisted in using the screws to transmit shear stresses, and the plywood plates centred in the lamellas failure zone to transmit tensile stresses caused by bending forces. Only screws were applied in the beams D1 and D3 due to shear failure (horizontal splits). The plywood plated should be necessary only in the central third of the beams where there are greater bending forces. However, given that the anchorage length of the plywood plates in some cases created the overlap of the two methods, it was decided to use the same screws, applied as in the shear repair, to fix the plywood plates to the beam. It was chosen to insert the screw perpendicular to the lamellas, instead of inserting them at an angle (which creates a better repair), using pre-drilling, because this method is easier to apply in on-site repairs to a high density wood such as in this case. 5

2.4.1. Shear stresses transmission The values used in the calculations are shown in Fig. 10, measures during the tests. Figure 10. Distance between elements The shear failure repair was performed with the HBS10160 self-tapping screws with the characteristics presented in table 1. It was used a design force value F = 45kN, resulting in a shear force of 22,5kN. Table 1. HBS10160 self-tapping screws characteristics Parafusos HBS10160 F u,k (MPa) 1000,00 d1 (mm) 10,00 d2 (mm) 6,40 ds (mm) 7,00 Where F u,k is the characteristic tensile strength of the screw; d1 is the outer thread diameter, d2 is the inner thread diameter; and ds is the smooth shank diameter. It was assumed that the bond was performed by the screws connecting two halves of the beam crosssection, whereby it was applied the equations (8.6) in the chapter 8.2.2. of the Eurocode 5 [6]. In the following expressions t i is the timber or board thickness or penetration depth, with i either 1 or 2; f h,i,k is the characteristic embedment strength in timber member i; M y,r,k is the characteristic screw yield moment; F ax,rk is the characteristic axial withdrawal capacity of the screw. F v,rk is the characteristic load-carrying capacity per shear plane per screw, which will correspond to the first type of failure to occur (equation 1). According to the section 8.7.1. of the Eurocode 5 [6], in (1) the value of the diameter d of the screw to use in the calculations shall be an effective diameter d ef = 1,1 x d2 = 7,04mm. The diameter of the screws is larger than 6mm so it is possible to use the same rules applicable to bolted connections (section 8.5.1. of the EC5 [6]). In this case =0º (angle formed between the applied strength and the grain direction). 6

(1) f h,0,k is the characteristic embedment strength parallel to grain and f u,k is the characteristic tensile strength of the screws. f h,0,k = 0,082(1 0,01d ef ) 600 = 45,74 MPa (2) M y,rk = 0,3 f u,k d 2,6 ef = 0,3 1000 7,04 2,6 = 47952 Nmm (3) Since the screws have a total length of 160mm, the thicknesses to consider in the calculations are the following: t 1 = 87,50mm and t 2 = 72,50mm, corresponding to the elements connected to the head of screw and the tip of the threaded part of the screw respectively. β is the ratio between the embedment strength of the members: β = f h,2,k f h,1,k (4) Since the screws have a total length of 160mm, the thicknesses to use in the calculations ate the following: t 1 = 81,50mm and t 2 = 72,50mm corresponding to the elements connected to the head and to the tip of the threaded part of the screw respectively. And since those elements made of the same material β = 1. (a)23,34 (b)28,17 (c)10,75 + 100% 10,75 = 21,50 F v,rk = min (d)8,85 + 100% 8,85 = 17,70 (e)10,43 + 100% 10,43 = 20,86 { (f)6,39 + 100% 6,39 = 12,78 (5) Which results in F v,rk = 12,78 kn With this value, the next step consisted in calculating the spacing between screws to use on the beams. is the maximum shear stress and F c the resulting force from the shear stresses. 7

τ = ( F 2 ) 3 2 1 = 2,03 MPa (6) b h F c = τ b = 192,86 kn (7) #Parafusos por metro = F c F v,rk b = 15,09 15 (8) For a better distribution, it was decided to place the screws in 2 rows, as displayed in Fig. 11. Figure 11. Scheme of the screws spacing 2.4.2. Tensile stresses transmission To the bending moment in the middle of the beam (21,60kN), it is obtained the following associated force F M : σ M = M = 44,55 MPa (9) w with w = bh2 6 (10) F M = 1 2 σ M h 2 b = 185,14 kn (11) To make the bending stresses transmission, it was decided to use two plywood plates and the HBS10240 self-tapping screw (in the plywood zones) with the same characteristics as the screws used in the shear stresses transmission, just with a bigger length. Fig 12 illustrates the scheme of a bending failure repair in the A1 and C1 beams, to help understand the location of the plywood plates. (Legend: blue HBS10240; Gray HBS10160; orange Plywood plate; brown Beam) Figure 12. C1 and A1 repair schemes In these zones the connection was assumed to be a central wood element (beam) connected by the screws to other two elements (plywood plates), applying the equations (8.7) of the Eurocode 5 [6] (double shear) where the index 1 corresponds to the plywood plates, and index 2 to the beam. 8

(12) Where: t 1 = 27mm, t 2 = 175mm and d = d ef = 7,04mm. According to the catalog of the Okoumé Plywood used: ρ k = 600 kg/m 3 f h,1,k = 0,11(1 1,01d ef ) ρ k = 61,35 MPa (13) Resulting in β = 0,741 And then: (g) 11,66 (h) 28,17 F v,rk = min (j) 5,43 + 100% 5,43 = 10,85 {(k)6,84 + 100% 6,84 = 13,68 F v,rk = 10,85 kn Considering double shear and two rows of screws, applying the correction factor recommended in the Eurocode 5 [6] to take into account the efficiency loss of using multiple screws in a row, there must be used a minimum number of 10 screws per row on the plywood plates, on each side of the connection. The spacing between the screws used in the plywood was the same used in the shear failure repair. 3. RESULTS 3.1. Initial tests The table 2 shows the average results (per type of beam) obtained in the initial bending tests. The deformation δ correspondent to the failure is the displacement obtained by the testing machine, being this value just a qualitative number to use in comparisons. The other values were calculated through the intersection of the LVDTs data and the testing machine data, resulting in real numbers (quantitative and qualitative value). The legend of the following tables is: F rot is the load-carrying capacity of the beam; E m,g is the global modulus of elasticity in bending; σ rot is tensile stress in the lowest fibre of the beam in mid-section correspondent to failure; τ rot is maximum shear stress in the supports zone correspondent to failure. 9

Table 2. Average results obtained in the initial bending tests Vigas F rot (kn) δ (mm) E m,g (MPa ) σ rot (MPa) τ rot (MPa) A 46,53 49,05 12633 46,18 2,10 B 22,03 27,09 11140 21,82 0,99 C 9,84 34,33 3825 11,12 0,51 D 43,24 42,43 13370 42,82 1,95 These results confirm that delamination reaching the totality of the cross-section glue lines in the edges of the beam (beams B and C ) affected the mechanical performance of the beams (strength and elasticity) more as the delamination length of the delamination. The results obtained in the A and D beams are very similar showing that in this case the delamination in the D beams doesn t affect its performance because there are straight beams where the design values are conditioned by bending stresses. 3.2. Tests after repair Table 3 show the average results (per type of beam) obtained in the bending tests after the repairs. Table 3. Average results obtained in the bending tests after the repairs Vigas F rot (kn) δ (mm) E m,g (MPa) σ rot (MPa) τ rot (MPa) A 36,83 49,07 10368 26,73 1,41 B 38,12 75,94 7753 37,74 1,72 C 24,48 79,18 4651 24,23 1,10 D 37,15 55,99 9538 36,78 1,68 3.3. Results analysis To help analysing the effectiveness of the repairs, it is presented in table 4 the recovery of the mechanical properties of the beams through a percentage of the quotient of the values obtained before and after the repairs. Table 4. Average recovery of the mechanical properties Vigas F rot (kn) δ (mm) E m,g (MPa) σ rot (MPa) τ rot (MPa) A 80% 100% 81% 57% 67% B 182% 304% 70% 182% 182% C 251% 230% 122% 220% 220% D 87% 142% 65% 87% 87% Here is possible to verify that the repair was much more effective on the B and C beams, recovering and improving its initial results and characteristics, although the repair s effects are much more effective in the bending strength (and ductility) rather than in the elasticity. In beams A and D 10

the recovery of both strength and elasticity are very similar in both type of beams, where the bending strength recovery was very effective (80% and 87% for beams A and D respectively). 4. DISCUSSION AND CONCLUSIONS Based on the obtained results it is possible to conclude that with the repair method used in this experimental work it is possible to recover the bending strength of the beams after their collapse, especially in beams with delamination in the edges reaching the totality of the cross-section glue lines. It was verified that the effectiveness of the repair was higher the lower deterioration suffered by the beam in caused by tensile failure of the lowest lamellas. Also, the repair method used was more effective recovering the shear stresses transmission capacity than recovering the tensile stresses transmission capacity. The results also show that it wasn t possible to recover the original elasticity of the beams as shown in figure 13 illustrating the graphics obtained in the bending tests before and after repair of the beams D1 and D2. Figure 13. Graphic comparison of the bending tests before and after repair, of the beams D1 and D2 The elasticity recovery would have been probably higher if the screws were to be introduces in pairs at an angle to the delamination direction. That was not possible to do, because it is a method of a hard technical execution on-site with cluster pine with a relatively high density. 11

5. References [1] EN 408:2004 - Timber structures - Structural timber and glued laminated timber - Determination of some physical and mechanical properties [2] EN 386:2001, Glued laminated timber: Performance requirements and minimum production requirements [3] EN 14080:2005 - Timber structures; Glued laminated timber Requirements [4] EN 392:1995 - Glued laminated timber: Shear test of glue lines [5] EN 391:2001 - Glued laminated timber: Delamination test of glue lines [6] EN 1995-1-1:2004/A1:2008: Eurocode 5 Design of timber structures. Part 1-1: General - Common rules and rules for buildings. CEN, Comité Européen de Normalisation, Bruxelas, 2008 12