Principle of Pulse Oximeter. SpO2 = HbO2/ (HbO2+ Hb)*100% (1)

Similar documents
Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( Pulse Oximetry: The story so far

An Advanced Architecture & Instrumentation for Developing the System of Monitoring a Vital Sign (Oxygen Saturation) of a Patient.

City, University of London Institutional Repository

DESIGN AND PROTOTYPING OF A MINIATURIZED SENSOR

D5.1 Report on the design of a fibre sensor based on NIRS

E-health Project Examination: Introduction of an Applicable Pulse Oximeter

Masimo Corporation 40 Parker Irvine, California Tel Fax

SFH Photoplethysmography Sensor

PhO 2. Smartphone based Blood Oxygen Level Measurement using Near-IR and RED Wave-guided Light

The OXY100C outputs four signals simultaneously, as shown in this graph: O 2 Saturation (beat-by-beat, CH 1) Pulse Waveform (beat-by-beat, CH 5)

PULSE OXIMETRY MODULE TO IMPLEMENT IN TEAM MONITOR OF VITAL SIGNS

Pulse Oximetry. Principles of oximetry

WRIST BAND PULSE OXIMETER

Design of the Pulse Oximetry Measurement Circuit and Its Sensing System Based On CMOS

City, University of London Institutional Repository

Design of Wearable Pulse Oximeter Sensor Module for Capturing PPG Signals

Signal Extraction Technology

PHYSIOLOGICAL SIGNALS AND VEHICLE PARAMETERS MONITORING SYSTEM FOR EMERGENCY PATIENT TRANSPORTATION

A Technology Overview of the Nellcor OxiMax Pulse Oximetry System

LOW POWER WIRELESS PULSE OXIMETER TERMINAL

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

PHOTOPLETHYSMOGRAPHIC DETECTOR FOR PERIPHERAL PULSE REGISTRATION

DESIGN OF A PHOTOPLETHYSMOGRAPHY BASED PULSE RATE DETECTOR

MASIMO RADICAL 7 Signal Extraction Pulse CO-Oximeter

HIGH RESOLUTION HADAMARD TRANSFORM OXIMETRY. D. Barschdorff, E. Starke

Intelligent Pillow for Heart Rate Monitor

Design of a Low-cost Pulse Oximeter

(51) Int Cl.: A61B 5/00 ( ) G06F 17/00 ( )

Design of Signal Conditioning Circuit for Photoelectric Sensor. , Zhennan Zhang

REMOTE HEALTH MONITORING SYSTEM USING PIC MICROCONTROLLER

INTEGRATION OF LOW COST SpO2 SENSOR IN A WEARABLE MONITOR

Sensors. CSE 666 Lecture Slides SUNY at Buffalo

Design of the Diffuse Optical Tomography Device

Instructions to User

Noninvasive PoC Anemia Detection Device

The Study on the Method of Eliminating Errors of PSD

ELR 4202C Project: Finger Pulse Display Module

Chapter 2. Design and development of blood volume pulse sensor and heart rate meter. Abstract

APPLICATION OF HEART PHOTOPLETHYSMOGRAPHY

Design of Ultrasonic Liquid Level Sensor Based on STM32 with MODBUS Protocol

Quad Rat Vitals Monitor. Client: Dr. Alex Converse. Advisor: Dr. Tom Yen. Group Members: Jack Ho Team Leader. Nathan Werbeckes Communicator

THE PULSE OXIMETRY DATA TRANSFER SYSTEM FOR WIRELESS

Wireless Sensor Networks. EP2980

A multiplexed electronic architecture for. opto-electronic patch sensor to effectively monitor heart rate and oxygen saturation.

(12) United States Patent

Innovative Experimental Low Cost Electronics Operated Instrumentation for Wearable Health Systems with High Resolution Physiological Measurements

United States Court of Appeals for the Federal Circuit

Keywords: Electronic Patch, Wireless Reflectance Pulse Oximetry, SpO2, Heart Rate, Body Temperature.

School of Electronic Science and Engineering, Nanjing University of Posts and Telecommunications, Nanjing, , China

Experimental Analysis of Luminescence in Printed Materials

Pulse Oximetry Dave Hoff Roy Zhang Tad Stalter Mike Carlson

Noncontact simultaneous dual wavelength photoplethysmography: A further step toward noncontact pulse oximetry

Design Considerations for Wrist- Wearable Heart Rate Monitors

6.111 Final Project Proposal HeartAware

zforce AIR Touch Sensor Specifications

Quad Rat Vitals Monitor

Dec. 21, 1993 (JP Japan O72 (51] Int. Cl... A61B5/00. (52) U.S.C /633; 356/41 (58) Field of Search /633, 664; 356/41

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

The Novel Integrating Sphere Type Near-Infrared Moisture Determination Instrument Based on LabVIEW

PRODUCT SHEET. fnir 2000C Imager fnir2000s Imager fnir2000p Imager

Distant pulse oximetry based on skin region extraction and multi-spectral measurement

BioTechnology. An Indian Journal FULL PAPER. Trade Science Inc. Research on the monitoring method of fiber bragg grating seismic waves ABSTRACT

Health and Fitness Analog solution. Wenbin Zhu Medical BDM June, 2015

P.O. Pro WIRELESS REFLECTANCE PULSE OXIMETER Design 2. December 1, 2004 Team # 3 James Hart Sofia Iddir Rob Mahar Naomi Thonakkaraparayil

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

Design & Implementation of Pulseoxymeter to Measures the Oxygen Saturation in Blood

Clinical evaluation of a novel adaptive algorithm for automated control of oxygen therapy in preterm infants on non-invasive respiratory support

EnviteC OEM compatible sensors The secure alternative in SpO 2 monitoring Choosing the right sensor is critical Modern health care practices a

(12) United States Patent (10) Patent No.: US 6,385,471 B1

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

ULS24 Frequently Asked Questions

OxSim Sp02 Simulator Operator's Manual

HUMAN BODY MONITORING SYSTEM USING WSN WITH GSM AND GPS

A Measurement of the Photon Detection Efficiency of Silicon Photomultipliers

Measure the roll-off frequency of an acousto-optic modulator

Improved Radiometry for LED Arrays

Low-cost photoplethysmograph solutions using the Raspberry Pi

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Improving the Collection Efficiency of Raman Scattering

Novel optical Measurement System for Laser Transmittance. and Reflectance of Materials*

OMEGAMONITOR BOM-L1 TR W

JEPPIAAR SRR Engineering College Padur, Ch

Design and Development of a Wireless Pulse Oximeter System

in the Computer Interpretation of Pulse Oximetry Data Farid U.Dowla, Paul G. Skolcowski and Richard R. Leach, Jr. Lawren= Livemre National Laboratoxy

A Novel Ring Shaped Photodiode for Reflectance Pulse Oximetry in Wireless Applications

AN2944 Application note

Analysis of Present State of the Digital Power Meter Field Calibration Technology

Research and Design on IGBT Induction Heating Power Supply

A Narrow-Band Tunable Diode Laser System with Grating Feedback

PCS-150 / PCI-200 High Speed Boxcar Modules

Silicon Photodiodes - SXUV Series with Platinum Silicide Front Entrance Windows

Laser Diodeexcitationsystem Controlled By Software For Photothermal Applications

Available online at ScienceDirect. Procedia Manufacturing 3 (2015 )

Optical Attenuation Sensor for Process Control

Next Generation Biometric Sensing in Wearable Devices

Clini-Ox II FINGERTIP PULSE OXIMETER. Instructions to User. Item # 18708

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Optical Fibre Amplifiers Continued

Development of an Optical Heart Rate Monitor using a Microchip PIC24-microcontroller based development board

Transcription:

Design of Pulse Oximeter Simulator Calibration Equipment Pu Zhang, Jing Chen, Yuandi Yang National Institute of Metrology, East of North Third Ring Road, Beijing, China,100013 Abstract -Saturation of peripheral oxygen (SpO 2 ) is one of the most important parameters of vital signs. Pulse oximeter which based on near-infrared spectroscopy is commonly used as a non-invasive method to measure SpO 2 [1],Currently, medical device manufacturers as well as metrology measurement agencies in China usually use pulse oximeter simulator as the commonly accepted functional calibration equipment for pulse oximeters. So far, there is no experimental protocol or devices can be used to test the accuracy and reliability of a pulse oximeter simulator, therefore, a set of new metrology apparatus with the name of pulse oximeter simulator calibration equipment have been designed in order to make a traceable system for the calibration or verification of pulse oximeter simulators. The principles and some research methods of this pulse oximeter simulator calibration equipment will be discussed in this paper. Besides that, many experiments have been applied in order to guarantee the accuracy as well as traceability of this set of equipment spectra of red and infrared light, as shown in Fig.2. LED Sensor, which seems like a finger clip, is an important component of pulse oximeter. One side is LEDs that emitting red (around 660nm) and infrared light (around 940nm) alternately, while the other side is a photodiode for receiving attenuated light and then translate into electrical signal, see Fig. 3. As shown in Fig. 1 and 3[2]. Fig. 1. Physical Principle of Pulse Oximeter - (a) I. INTRODUCTION Principle of Pulse Oximeter SpO 2 is determined by the relative proportions of oxygenated hemoglobin (HbO 2 ) and reduced hemoglobin (Hb) in arterial blood. SpO2 = HbO2/ (HbO2+ Hb)*100% (1) Pulse oximeter is based on two physical principles: (a) the presence of a pulsatile signal generated by arterial blood, which is relatively independent of non-pulsatile arterialblood, venous and capillary blood, and other tissues, as shown in Fig.1; (b) the fact that HbO2 and Hb have different absorption Fig. 2. Physical Principle of Pulse Oximeter - (b)

Currently, according to some statistics, about 100 R-SpO 2 curves or more are commercially used, as shown in Fig.4. However, these curves possess one characteristic in common, that is R value is in approximately inverse proportion with SpO 2. Fig. 3. LED Sensor of Pulse Oximeter After passing through finger, the variable absorption by arterial blood is considered as the AC signal, while the constant absorption by venous, capillary blood, and other tissues is considered as the "DC signal". Therefore, based on Lamber-Beer Law, the main algorithm, normally named as R-SpO 2 curve are simply summarized: 1) Calculating the absorption ratio (R value) between red and infrared light, different manufacturers usually adopt red and infrared light with various wavelength : R = ( AC / DC) ( AC / DC) IR RED (2) 2) Actually, the corresponding relation between R value and SpO 2 is on the bases of a great amount of clinical test data and statistic analyses, the constant A,B,C are all empirical values from each manufacturer. SpO 2 = C B R A* 2 * R (3) The Principle of Pulse Oximeter Simulator Pulse oximeter simulator is used to simulate the light attenuation during passing through human fingers by blood absorption. The test probe, which seems like an artificial finger, is a typical optical unit. One side with photodiode is used for detecting the red and infrared light signals, while the other side is equipped with LEDs[3]. After detecting the light from light sensors of pulse oximeter, the micro-processor system controls the LEDs emitting corresponding light intensity with certain frequency according to the default SpO2 and pulse rate values, as shown in Fig. 5. Fig. 5. Principle of Pulse Oximeter Simulator Fig. 4. some typical R-SpO2 curves II. DESIGNING PULSE OXIMETER SIMULATOR CALIBRATION EQUIPMENT This set of pulse oximeter simulator calibration equipment consists about three main parts, there are standard sensors, a hardware unit and a computer which is equipped with specialized software. After connecting with pulse oximeter simulator, the whole equipment can be used to measure the accuracy and

reliability of SpO 2 and plus rate values which are stimulated by pulse oximeter simulator, as shown in Fig.6. The hardware unit makes the stability of standard sensor (light sources emitting and attenuated light detecting) better than 0.5%. Fig. 6. Design of Pulse Oximeter Simulator Calibration Equipment A. Standard Sensors As different R-SpO 2 curves get different wavelengthes of red and infrared light, therefore, 4 standard sensors are prepared for Nellcor, Omeda, BCI and Masimo cureves, which are widely used ones. Moreover, Standard sensors can be renewed according to the further requirement.in order to accommodate dissimilar sizes of test probes of pulse oximeter simulators, standard sensors are designed with two important characteristics: thickness adjustable and light proof[4]. B. Hardware Unit In this part, the SCM plays a leading role in system controlling. For example, generating signals with certain frequency in order to make the standard sensor emitting red and infrared light alternatively, and after receiving the attenuated light from light activated diode, the operational amplifier as well as the photoelectric converter will transfer the light into voltage signals which are then input into Data Acquisition Card for further processing. Besides that, negative feedback circuit is applied in order to make the standard sensors emitting stable light sources. C. Computer with Specialized Software This specialized software has got two general functions, one is data processing, and the other is automated experimentation flow. For data processing, the software program not only abstracts and separates light signals that received by standard sensors, but also calculates the R value, which is corresponding to SpO2 value, from the attenuated light signals. Finally, the calculated results (both SpO2 and pulse rate values) will be compared with the default values from the pulse oximeter simulator and displayed on the user interface, meanwhile, all of the test data can be saved and printed in the form of test report. The purpose of designing the pulse oximeter simulator calibration equipment is to form a complete traceability system for the test of SpO 2 as well as pulse rate value. In order to guarantee the accuracy together with traceability of this set of equipment, a lot of experimentations have been carried out. For the test of SpO 2 value, which is verified by standard illuminant and neutral density filters, it can be traced to National Measurement Standard of Primary Photometric. While the pulse rate value, which can be verified by standard signal generator, could be traced to National Measurement Standard of Primary Frequency in China. Since this set of equipment has been designed and completed, it realizes an integrated chain for the metrology of the pulse oximeter and its correlative instruments, as shown in Fig. 7. Fig. 7. Integrated Chain of Traceability

III. EXPERIMENTAL DATA ANALYSIS As different R-SpO 2 curves have distinct sensors, take the sensor of Necllor curve for example, it provides the 660nm red light and the 890nm infrared light. As the simulator imitates the intensity attenuation informationof red and infrared light, consequently, if the standard sensor provides stable and normative optical trigger according to the corresponding curve, the pulse oximeter simulator can be calibrated. In other words, stability is the key indicator for the standard equipment. In this section, several experiments are used to detect the accuracy and stability of this equipment. A. The accuracy of standard sensor's wavelength Nominal Measure TABLE II ACCURACY OF SpO 2 Tollere 30 50 60 70 80 90 100 -nce ±1 30 50 60. 70 80 90 100 3 0 0 0.5 1 0 0 0 ±0.67 TABLE III STABILITY OF SENSOR 0.1% 10 30 50 70 90 110 uation uatio 0.1 0.2 0.2 0.1 0.3 0.2 0.3 1% 10 30 50 70 90 110 uation Fig. 8. wavelength test As shown in Fig.8, the part of experiment should be tested about every month, if the wavelength is not accurate, the standard sensor must be adjusted. B. The detection of standard sensor In this part, signal generator is used to test the accuracy and stability of pulse rate, standard light source and neutral density filters are together with the use of checking light stability and accuracy of the sensor. TABLE I ACCURACY OF PULSE RATE Nominal 30 50 100 150 200 300 400 Tollere -nce ±1 Measure Mean 30 50 100 151 200 300 400 0 0 0 1 0 0 0 ±1 uatio 0.3 0.3 0.2 0.4 0.1 0.2 0.4 5% 10% 10 30 50 70 90 110 uation uatio 0.1 0.3 0.2 0.2 0.2 0.3 0.3 10 30 50 70 90 110 uation uatio 0.2 0.1 0.1 0.2 0.2 0.2 0.2 IV. CONCLUSION Designing a set of pulse oximeter simulator calibration equipment is a challenge for metrology engineers. According to all the analysis and results

above, pulse oximeter simulator calibration equipment can be used to calibrate the value of SpO 2 as well as pulse rate of pulse oximeter simulator. The stability of light source is better than 0.5%, and on the basis of theoretical analysis and lots of experimentation, the whole equipment gets the measurement range of SpO 2 (30-100%, with the precision of 1%), and has a mean difference (bias) of < 1%, while the measurement range of pulse rate is (0-400BPM, with the precision of 0.1BPM), and has a mean difference (bias) of < 1BPM. This set of pulse oximeter simulator calibration equipment can be traced to Primary Photometric and Primary Frerquency of National Measurement Standards in China, and it has also been figured as an intending National Measurement Standard for Pulse Oximeter Simulators. REFERENCES [1] Jubran A: Pulse Oximeter. In: Tobin MJ (ed). Principles and Practice of Intensive Care Monitoring. New York: McGraw Hill, Inc.; 1998. pp.261 287. [2] Hornberger Ch, A prototype device for standardized calibration of pulse oximeters II.J ClinMonit 2002; 17: pp.203-209. [3] Natasha Stabile, Karen J. Reynolds. Technological Review of Pulse Oximeter Simulators. Journal of Clinical Engineering, Fall 2002; pp. 287-297 [4] Marco Fernandez, Evaluation of A New pulse Oximeter Sensor. American Journal of Critical Care. 2007;16: pp.146-152.