Turbine Temperature Test Set

Similar documents
TT-1000A TURBINE TEMPERATURE TEST SET USER INSTRUCTION MANUAL M/N: TT-1000A P/N: Doc. P/N: Revision E September 19, 2014

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

MODEL W Power Amplifier

Process Calibrator. TechChek 820

PIECAL 820 FIELD CALIBRATION PROCEDURE

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

731A seismic accelerometer and P31 power unit/amplifier Operating guide

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Printing Humidity/Temperature Meter

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

M-1000D DIGITAL MULTIMETER

32 CHANNEL SELECTABLE CH MHZ DOWN VOLUME

AD-8100 & AD-8200 Servo Amplifiers

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

AC/DC Current Oscilloscope Probe Model SL261

Model Biconical Antenna. User Manual

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

742A Series Resistance Standards

Model 4007DDS. 7 MHz Sweep Function Generator

Model 863 Quad Timing Filter Amplifier Operating and Service Manual

Model Operating Manual

Digi-Stop. User Manual for: Digi-Stop. Digital Readout Firmware version d & Higher

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

41P Portable Calibrator User Manual

PIECAL 211 Automated Universal RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Model 428 Detector Bias Supply Operating and Service Manual

AMM-1022 Digital Multimeter USER`S MANUAL

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Multifunction AC/DC Voltage Tester

Automated Thermocouple & RTD Calibrator

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

User s Guide ASSISTIVE LISTENING SYSTEMS

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

3 CHANNEL LOAD CELL SIGNAL CONDITIONER. Owner's Manual

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

Model Biconical Antenna. User Manual

Model Hz to 10MHz Precision Phasemeter. Operating Manual

Professional UHF Rechargeable Wireless Microphone System POWER ON/OFF BATTERY CHARGE. Green Light (Full) Better Music Builder DOWN VOLUME

PIE 525B. Automated Thermocouple & RTD Calibrator Operating Instructions. Practical Instrument Electronics

Resonance indicator LEDº. » Transducer connection. Button B º. » LCD display. Power/fine frequency º. frequency set

DIGIT & POINTER MULTIMETER

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Exhaust Gas Technologies Thermocouple Amplifier Datasheet Single Channel Dual Channel Quad Channel

Thank you very much for choosing Shuguang Audio Classic Series vacuum tube amplifier

Distribution Amplifiers 1

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

NU2. Dual UHF Wireless System. Item ref: UK, UK, UK, UK User Manual. Version 1.0

IMP-2A ELECTRODE IMPEDANCE TESTER SINGLE CHANNEL

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

User s Guide. Model MA A AC Mini Clamp-on Meter

Model 9302 Amplifier-Discriminator Operating and Service Manual

OPERATOR S MANUAL Model 77E Pneumatic Cable Stripper

USB-TC Instructions. Description

Assistive Listening Systems. RX-6 User s Guide

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Model BiConiLog Antenna. User Manual

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Warning, refer to accompanying documents V CAT II Overvoltage category II device. CSA Canadian Standards Association

DM-45 Digital Multimeter

Compact Signal Calibrator

FST Series HUMIDITY-TEMPERATURE TRANSMITTERS INSTRUCTION MANUAL

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

Digi-Stop. Installation & Operation

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

User s Manual For PAMS. Portable Attenuation Measurement System /

Dawson DDM190. Digital Multimeter User s Manual

201AP Charge Amplifier User Manual

MEGOHMMETER. User Manual

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE

AV30MX-2 Operation Manual

MODEL TS-113 VOLT-OHM-MILLIAMMETER. Operator s Manual WARNING READ AND UNDERSTAND THIS MANUAL BEFORE USING THE INSTRUMENT

LCT100. Load Cell Tester User s Guide (v1711) Anyload Transducer Co. Ltd Website:

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Media Storage Systems Fixed Media Cabinets

Cat. No. H8861 Model: RCL-S-STAT

200B Clipper Module User Manual

USER'S MANUAL DMR-6700

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

TT-2Dx USER'S MANUAL

Analog Technologies. Multimeter 15B and17b

MS2109A AC/DC Clamp Meter. User Manual. Contents

Ambient Level Controller

NOVALYNX CORPORATION MODEL 110-WS-16TH TEMPERATURE AND RELATIVE HUMIDITY SENSOR INSTRUCTION MANUAL

Double-Ridged Waveguide Horn Antennas

411LA Broadband Power Amplifier

Transcription:

TT1200 Turbine Temperature Test Set USER INSTRUCTION MANUAL BARFIELD M/N TT1200 56-101-00920 Revision D November 7, 2014 BARFIELD, INC. Corporate Headquarters 4101 Northwest 29th Street Miami, Florida 33142 www.barfieldinc.com Email: gsesales@barfieldinc.com Copyright 2014 Barfield Inc. All Rights Reserved.

CONTACT INFORMATION Users are requested to notify the manufacturer of any discrepancy, omission, or error found in this manual. Inquiries should include specific questions and reference the publication title, number, chapter, page, figure, paragraph, and effective date. Please send comments to: TECHNICAL CUSTOMER SUPPORT - GSTE BARFIELD, INC. P.O. BOX 025367 MIAMI, FL 33102-5367 USA Telephone (305) 894-5400 (800) 321-1039 Fax (305) 894-5401 Email gsesales@barfieldinc.com 56-101-00920-D Nov / 7 / 14 Contact Page ii

ATTENTION Although every effort has been made to provide the end user of this equipment with the most current and accurate information, it may be necessary to revise this manual in the future. Please be sure to complete and return the enclosed OWNER WARRANTY REGISTRATION CARD to Barfield in order to validate the warranty and to ensure that you will receive updated information when published. You MUST have your name and address on file at Barfield as a registered user of this equipment, to be able to obtain the service covered by the warranty. Visit the company website, http://barfieldinc.com/, for publication updates. Please send the Registration Card to: Barfield, Inc. P.O. Box 025367 Miami, FL 33102-5367 USA 56-101-00920-D Nov / 7 / 14 Attention Page iii

REVISION RECORD REV. ECO # REV. DATE DESCRIPTION OF CHANGE A N/A Jan. 24, 1995 Initial Release B --- Oct. 20, 2000 Added Addendum A (Option A). Revised Table of Contents accordingly. C 260-00729 Sep. 15, 2008 Updated Company Logo and Format D 260-01059 Nov. 7, 2014 Updated Barfield logo 56-101-00920-D Nov / 7 / 14 REV Page iv

MAINTENANCE AND REPAIR INFORMATION The manufacturer of this equipment does not recommend the user to attempt any maintenance or repair. In case of malfunction, contact the manufacturer, to obtain the list of approved repair facilities worldwide, ensuring that this equipment will be serviced using proper procedures and certified instruments. BARFIELD PRODUCT SUPPORT DIVISION Telephone (305) 894-5400 (800) 321-1039 Fax (305) 894-5401 Shipping Address: Barfield, Inc. 4101 NW 29th Street Miami, Florida 33142 USA Mailing Address: Barfield, Inc. P.O. Box 025367 Miami, FL 33102-5367 USA 56-101-00920-D Nov / 7 / 14 Maint. Page v

This page intentionally left blank. 56-101-00920-D Nov / 7 / 14 Blank Page vi

TABLE OF CONTENTS Contact Information Attention Page Revision Record Maintenance and Repair Information Table of Contents PAGE CHAPTER 1: GENERAL INFORMATION 1. Purpose of Manual... 1 2. General Description of the Test Set... 1 3. Switching Functions... 2 4. Recertification... 4 CHAPTER 2: OPERATION 1. General Operating Instructions... 5 2. System Lead Resistance Measurement... 6 3. Thermocouple Resistance Test Procedure... 7 4. Insulation Testing Procedure... 8 5. Indicator Test Procedure (With Specified Lead Resistance)... 8 6. Potentiometric or Servoed Indicator Test Procedure (Without Lead Resistance)... 9 7. Temperature Measurement Test Procedure... 11 CHAPTER 3: SPECIFICATIONS AND CAPABILITIES 1. Physical Data... 12 2. Specifications... 12 3. Capabilities... 13 CHAPTER 4: RECEIVING, SHIPPING, AND STORAGE 1. Receiving... 14 2. Shipping... 14 3. Storage... 14 56-101-00920-D Nov / 7 / 14 TOC Page vii

This page intentionally left blank. 56-101-00920-D Nov / 7 / 14 Blank Page viii

CHAPTER 1: GENERAL INFORMATION 1. PURPOSE OF MANUAL A. This publication contains the description and the operating procedures for the: TT1200 DIGITAL TURBINE TEMPERATURE TEST SET, P/N 101-00920 Fig. 1. Manufactured by: BARFIELD, INC. 4101 NW 29th Street Miami Florida 33142 USA B. This manual is developed to address the above Test Set especially designed to test and calibrate Chromel-Alumel (CH-AL) temperature indicating systems. It contains complete instructions for maintenance inspection, testing, troubleshooting, and calibration of systems installed on aircraft engines. 2. GENERAL DESCRIPTION OF THE TEST SET The TT1200 provides the means for quickly troubleshooting aircraft temperature indicating systems. It has sufficient sensitivity and accuracy to test thermocouple and system resistance, insulation, and indicator calibration. It features portability, simplicity of operation, direct reading, and multi-function versatility. A. TT1200 Features (1) Specifically designed to meet all requirements for testing aircraft Chromel-Alumel (CH-AL) temperature measuring systems and provides an accurate display of thermocouple outputs in degrees Celsius ( C). (2) Thermocouple and lead resistance measurements to 0.001 ohm and insulation measurements up to 200 megohms. (3) Simulates thermocouple outputs and system lead resistances from 2 to 25 ohms. (4) Completely self-contained, self-monitoring, easily portable temperature and resistance measuring and simulating device for all CH-AL systems with the capability to bench test indicators. 56-101-00920-D CH. 1 Nov / 7 / 14 Page 1 of 14

(5) Human engineered for maximum ease of operation and maintenance with state of the art low battery drain circuitry with automatic ambient test point temperature correction. (6) A large, 9mm (0.35") high characters, 4 1/2 digit Liquid Crystal Display (LCD) with pre-programmed legends. (7) Carrying Case features; (a) Fabricated from high impact plastic. (b) Provides a pouch on the rear for test lead storage. (c) The lid contains a placard of abridged operating instructions for the experienced technician. NOTE: For nonexperienced personnel it is advisable to become familiar with this publication, the TT1200, and the aircraft system before performing any test or checks. 3. SWITCHING FUNCTIONS (Ref. Fig. 1) A. The ON/OFF toggle switch (1) applies power for all functions. B. The RANGE switch (2), a 4 position rotary switch, permits selection of the resistance and insulation ranges, 20Ω, 200Ω 2KΩ and 20KΩ for RES MEAS or 200KΩ, 2MΩ, 20MΩ and 200MΩ for INS MEAS. The fourth position is also used for 0 ohm system resistance for the IND TEST function. C. The PTM (Press To Measure) pushbutton (3), when depressed activates the TT1200 excitation and measuring circuitry when the FUNCTION switch is set to the RES MEAS or INS MEAS positions. D. The PTS (Press To Set) pushbutton (4), when depressed with test leads shorted and the FUNCTION switch in the RES MEAS position connects the SYS RES potentiometer for system resistance adjustment. E. The SYStem RESistance control knob (5), a 10 turn potentiometer used to adjust system lead resistance, 2 to 25 ohms, when test leads are shorted and the PTS pushbutton is depressed. F. The TEST connector (6) provides the means for connecting the TT1200's standard leads or specifically designed interface cabling. 56-101-00920-D CH. 1 Nov / 7 / 14 Page 2 of 14

a Sabena technics company TT1200 FRONT PANEL LAYOUT Figure 1 56-101-00920-D CH. 1 Nov / 7 / 14 Page 3 of 14

G. The display (7) is a 4 1/2 digit LCD which provides all the readings with associated units and legends for low battery warning (BAT) and an open thermocouple circuit (OPEN). H. Two battery holders (8) house 4 each AA alkaline cells which provide power for all test set functions. I. The TEMP ADJ control knob (9), a 10 turn potentiometer permits coarse adjustment of the temperature or millivoltage while the FINE control (10), provides exact adjustment of the readings which are displayed on the LCD when the FUNCTION switch is in the IND TEST position. J. The o C/MV toggle switch (11) allows the user to configure the test set to display either o C or millivoltage when the FUNCTION switch is set to IND TEST or TEMP MEAS positions. The center position, MV (amb_ient comp_ensated), provides the operator with a millivoltage display that is based on a reference junction at 0 o C. The lower position, MV, may be thought of as a DVM function and provides the user with a display equivalent to having a DVM connected in parallel at the test set's Red and Black clips. K. The FUNCTION switch (12), a 4 position rotary switch that permits selection of the four principal test functions, RESistance MEASure, INSulation MEASure, INDicator TEST and TEMPerature MEASure. L. The 1 o C/.1 o C toggle switch (13) allows the user to set the test set's display resolution when the FUNCTION switch is set to IND TEST or TEMP MEAS and o C is selected. 4. RECERTIFICATION The Test Set P/N 101-00920 has a one-year recertification requirement. Maintenance required by this unit must be performed by qualified technicians in a shop equipped with the necessary tooling and facilities. 56-101-00920-D CH. 1 Nov / 7 / 14 Page 4 of 14

CHAPTER 2: OPERATION 1. GENERAL OPERATING INSTRUCTIONS Consult temperature indicator system and/or engine manufacturer's instructions for procedures and specifications. Read complete TT1200 Operation procedures before attempting to use the TT1200. A. Protective Circuits; (1) Although the TT1200 has input protection the test set should never be connected to an energized circuit. B. Preparation For Use: (1) Battery Installation / Replacement; C. Precautions (a) Using a coin or screwdriver remove the covers from the battery holders located in the upper right corner of the panel. Invert the TT1200 so that batteries slide out. With the TT1200 upright insert two AA alkaline batteries into each holder with the negative terminals down for all. (b) To check the 4 AA batteries set the FUNCTION switch to RES MEAS, the RANGE switch to 20 ohm position and short test lead clips together. (c) Depress the PTM pushbutton switch. If BAT is displayed replace the batteries as detailed above. (1) Do NOT press either pushbutton with test clips connected to the aircraft indicator. The current applied may damage the indicator. (2) Do NOT connect test clips to an energized circuit. Although the TT1200 is provided with protective devices, not all damaging potentials can be made completely safe. (3) Allow sufficient time for test clips to stabilize to the temperature of the terminals to which they are connected for temperature tests. (4) Measure system and thermocouple resistance with a cold engine for greatest accuracy. 56-101-00920-D CH. 2 Nov / 7 / 14 Page 5 of 14

(5) To conserve battery power, place ON/OFF switch to OFF when the test set is not in use. (6) BAT warning displayed indicates about 10% battery life of the batteries remain and they should be replaced. D. Hot Engine Testing A hot engine will cause thermocouples to generate a small potential which will produce errors in measured resistance values. This effect is inherent in any type resistance measuring instrument. The effect can be circumvented by taking two measurements; the first with test leads connected in one polarity, and then reversing the lead connections for the second measurement. The true value is equal to the average of the two readings (i.e., add the two readings and divide by two). The two readings must be taken in quick succession so that the thermocouple temperature will be the same for both readings. If the thermocouples are too hot, the readings will be too far from nominal to provide sufficient accuracy. In such a case, wait for the engine to cool further. 2. SYSTEM LEAD RESISTANCE TEST PROCEDURE A. Disconnect thermocouple leads from system temperature indicator. B. Carefully connect test lead clips to each of the lead wires insuring a good electrical connection. C. Set the FUNCTION switch to RES MEAS. D. Set the RANGE switch to 200 ohm. E. Setting of 1 o C/.1 o C switch is immaterial. F. Setting of o C/MV switch is immaterial. G. Place ON/OFF switch to ON and depress the PTM pushbutton switch. H. Display will indicate resistance in ohms to within ± 0.01 ohm. If a 1. is displayed, resistance is greater than 199.99 ohms or there is an open circuit. 56-101-00920-D CH. 2 Nov / 7 / 14 Page 6 of 14

I. Interchange RED and BLACK test clip connections and the display should repeat when the PTM pushbutton is depressed. If the reading does not repeat, the engine thermocouples may be hot. (Ref. Para. 1. D. above.) NOTE: Resistance must be within manufacturer's specifications. If results are slightly outside limits, repeat entire procedure to insure test failure is not due to human error. J. Place ON/OFF switch to OFF, disconnect the TT1200 and return aircraft to original configuration. 3. THERMOCOUPLE RESISTANCE TEST PROCEDURE A. Disconnect thermocouple leads from system temperature indicator. B. Carefully connect test lead clips to each of the lead wires insuring a good electrical connection. C. Set the FUNCTION switch to RES MEAS. D. Set the RANGE switch to 200 ohm. E. Setting of 1 o C/.1 o C switch is immaterial. F. Setting of o C/MV switch is immaterial. G. Place ON/OFF switch to ON and depress the PTM pushbutton switch. H. Display will indicate resistance in ohms to within ± 0.01 ohm. If a 1. is displayed, resistance is greater than 199.99 ohms or there is an open circuit. I. Interchange RED and BLACK test clip connections and the display should repeat when the PTM pushbutton is depressed. If the reading does not repeat, the engine thermocouples may be hot. (Ref. Para. 1. D. above.) NOTE: Resistance must be within manufacturer's specifications. If results are slightly outside limits, repeat entire procedure to insure test failure is not due to human error. J. Place ON/OFF switch to OFF, disconnect the TT1200 and return aircraft to original configuration. 56-101-00920-D CH. 2 Nov / 7 / 14 Page 7 of 14

4. INSULATION TESTING PROCEDURE A. Disconnect one or both leads at system temperature indicator. Then connect the BLACK lead clip to ground and the RED lead clip to one or both thermocouple system lead wires. (Ref. engine manufacturers' Maintenance Manual for specific hookup.) B. Set the FUNCTION switch to INS MEAS. C. Set the RANGE switch to 2M ohm or as desired. D. Setting of 1 o C/.1 o C switch is immaterial. E. Setting of o C/MV switch is immaterial. F. Place ON/OFF switch to ON and depress the PTM pushbutton switch. G. Display will indicate insulation resistance in 1,000,000's of ohms (megohms). If a 1. is displayed, resistance is greater than 1.999 megohms or there is an open circuit. NOTE: Resistance to ground must not be less than manufacturer's specifications. H. Place ON/OFF switch to OFF, disconnect the TT1200 and return aircraft to original configuration. 5. INDICATOR TEST PROCEDURE (With Specified Lead Resistance) A. Set the FUNCTION switch to RES MEAS. B. Set the RANGE switch to 200 ohm. C. Place ON/OFF switch to ON. D. Short test lead clips together and depress the PTS pushbutton while adjusting SYS RES control knob for displayed system resistance to be simulated. E. Set the FUNCTION switch to IND TEST. F. Set 1 o C/.1 o C switch as desired. G. Set o C/MV switch to o C or as desired. H. Disconnect aircraft thermocouple leads from temperature indicator. 56-101-00920-D CH. 2 Nov / 7 / 14 Page 8 of 14

I. Connect test lead clips to indicator terminals, OBSERVING POLARITY. Alumel is negative (-) and connects to the TT1200 BLACK clip: Chromel is positive (+) and connects to the TT1200 RED clip. J. Set TEMP ADJ control for the desired test temperature as displayed on the digital indicator. It may be necessary to use the FINE control to achieve the exact settings. K. Compare readings of indicator under test with TT1200 indications. NOTE: Indicator must agree with TT1200 reading to within manufacturers' specifications. L. Place ON/OFF switch to OFF, disconnect the TT1200 and return aircraft to original configuration. 6. POTENTIOMETRIC OR SERVOED TYPE INDICATOR TEST PROCEDURE (Without Lead Resistance) A. General (1) The Potentiometric or Servoed indicator, as it is generally referred to may be recognized by its multiple pin electrical connector and the requirement of aircraft electrical power to operate. (2) Thermocouple lead resistance is not critical with this type of indicator, and usually need not be measured. B. System Lead Resistance Measurement: (1) Disconnect aircraft power to indicator. (Ref. Maintenance Manual) (2) Disconnect electrical connector at rear of indicator. (3) Connect TT1200 leads to probe pins sized to fit chromel and alumel pin sockets of aircraft plug removed from indicator. (4) Follow Para. 2. System Lead Resistance Test Procedure, steps C. through H above. NOTE: Lead resistance is not critical, generally in the order of 5 to 100 ohms. (Ref. Maintenance Manual for specific values.) 56-101-00920-D CH. 2 Nov / 7 / 14 Page 9 of 14

C. Thermocouple Resistance Measurement: (1) Disconnect aircraft power to indicator. (Ref. Maintenance Manual) (2) Follow Para. 3. Thermocouple Resistance Test Procedure above. D. Insulation Testing: (1) Disconnect aircraft power to indicator. (Ref. Maintenance Manual) (2) Disconnect electrical connector at rear of indicator (3) Follow Para. 4. Insulation Testing Procedure, steps B. thru F. above, using probe pins at aircraft plug or make connection at engine thermocouple terminal blocks. E. Indicator Test: (1) Disconnect aircraft power to indicator. (Ref. Maintenance Manual) (2) Disconnect leads from indicator at engine thermocouple terminal block. (3) Set the FUNCTION switch to IND TEST. (4) Set the RANGE switch to 20 K ohm - 0 Ω SYS RES. (5) Set 1 o C/.1 o C switch as desired. (6) Set o C/MV switch to o C or as desired. (7) Connect test lead clips to indicator leads OBSERVING POLARITY. Alumel is negative (-) and connects to the TT1200 BLACK clip: Chromel is positive (+) and connects to the TT1200 RED clip. (8) Place aircraft temperature indicating system power to ON. (9) Place ON/OFF switch to ON. (10) Rotate the TEMP ADJ control for desired test points as read on the TT1200 digital display.it may be necessary to use the FINE control to achieve the exact settings. (11) Compare readings of indicator under test with TT1200 indications. NOTE: Indicator must agree with TT1200 reading to within manufacturer's specifications. 56-101-00920-D CH. 2 Nov / 7 / 14 Page 10 of 14

(12) Place aircraft temperature indicating system power to OFF. (13) Place ON/OFF switch to OFF, disconnect the TT1200 and return aircraft to original configuration. 7. TEMPERATURE MEASUREMENT TEST PROCEDURE A. Set the FUNCTION switch to TEMP MEAS. B. Set the RANGE switch to 20 K ohm - 0 Ω SYS RES. C. Set 1 o C/.1 o C switch as desired. D. Set o C/MV switch to o C or as desired. CAUTION: AIRCRAFT INDICATORS OF THE D'ARSONVAL TYPE MUST NOT BE CONNECTED DURING THIS TEST. D'ARSONVAL INDICATORS MAY GENERALLY BE RECOGNIZED BY THE ABSENCE OF A MULTI-PIN CONNECTOR AND WILL USUALLY HAVE TWO TERMINAL POSTS OR TERMINAL SCREWS. E. Connect test lead clips to thermocouple leads OBSERVING POLARITY. Alumel is negative (-) and connects to the TT1200 BLACK clip: Chromel is positive (+) and connects to the TT1200 RED clip. F. Display will indicate thermocouple temperature directly in o C. NOTE: If the word OPEN is displayed, there is an open circuit in the thermocouple or lead wires. 56-101-00920-D CH. 2 Nov / 7 / 14 Page 11 of 14

CHAPTER 3: SPECIFICATIONS AND CAPABILITIES 1. PHYSICAL DATA A. Height: 6.5 in (16.5 cm) B. Width: 9.3 in (23.6 cm) C. Depth : 7.0 in (17.8 cm) D. Weight: 5.4 lbs (2.4 kg) 2. SPECIFICATIONS A. Temperature Measurement: (1) Type: K (CH-AL Thermocouple). (2) Range: 0 to 1200 o C certified, -50 to +1250 o C extended. (3) Accuracy: Typical measurement error at 25 o C ambient: less than ±0.3 o C. B. Lead Resistance: (1) Range; 0-19.999 ohms in 0.001 ohm increments. Range; 0-199.99 ohms in 0.01 ohm increments. Range; 0-1.9999 K ohms in 0.1 ohm increments. Range; 0-19.999 K ohms in 1 ohm increments. (2) Accuracy; ± 0.05% of reading ± 2 counts C. Insulation: (1) Range; 0-199.9 kω in 0.1K ohm increments. Range; 0-1.999 MΩ in 1K ohm increments. Range; 0-19.99 MΩ in 10K ohm increments. Range; 0-199.9 MΩ in 100K ohm increments. (2) Accuracy; ± 5% of reading ± 2 counts. (3) Excitation; 45V DC nominal. 56-101-00920-D CH. 3 Nov / 7 / 14 Page 12 of 14

D. Simulated System Resistance: (1) Adjustment Range; Less than 2.0 ohms to greater than 25 ohms. (2) Fixed Setting; Less than 0.1 ohm. 3. CAPABILITIES A. Measures and displays resistance of thermocouples, thermocouple rings and system lead circuits. B. Measures and displays insulation resistance of system wiring and other components. C. Simulates CH-AL thermocouples with or without simulated system lead resistance. D. Measures and displays values of CH-AL thermocouples in terms of degrees Celsius ( o C) temperature. E. Automatically compensates for ambient temperature at test lead connection junction point or indicates this cold junction temperature. 56-101-00920-D CH. 3 Nov / 7 / 14 Page 13 of 14

CHAPTER 4: RECEIVING, SHIPPING, AND STORAGE 1. RECEIVING No special unpacking procedures are necessary. It is recommended that factory shipping container and packing materials be retained should it become necessary, for any reason, to reship the Test Set. It is also recommended that the Test Set be carefully inspected for damage. If damaged, immediately notify both the carrier and manufacturer. 2. SHIPPING Use standard delicate electronic equipment packaging procedures when packing the Test Set for reshipment. 3. STORAGE Store in a cool dry place. 56-101-00920-D CH. 4 Nov / 7 / 14 Page 14 of 14