Chicago Plumber Licensure Examination Information

Similar documents
Introduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE

Credentials for Career Technical Education Teachers and/or Students

A. This Section includes plumbing fixtures and related components.

BUILDING DEPARTMENT CURRENT

SECTION PLUMBING FIXTURES

University of Houston Master Construction Specifications Insert Project Name SECTION MECHANICAL SCOPE OF WORK PART 1 - GENERAL

Plan Review and Standards

ERRATA AND REVISIONS to the CANADIAN PLUMBING CODE

Commercial Plumber Apprenticeship

NOTICE OF INCORPORATION United States Legal Document

Plumbing. Study Guide. Assessment: 3601 Plumbing Apprentice Technician. Aligned to NCCER National Standards

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

SECTION BASIC MATERIALS AND METHODS

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - FIXTURES AND TRIM

Existing and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.

Introduction to Site Layout Annotated Instructor s Guide. Module PREREQUISITES MODULE OVERVIEW OBJECTIVES PERFORMANCE TASKS

NCCER Progress Blvd, Alachua, Florida Phone: (888)

Cast Copper Alloy Solder Joint Drainage Fittings: DWV

Thermoplastic Valves Sewer Disconnect

PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

A/E REVIEW CHECKLIST PLUMBING/FIRE PROTECTION/SANITARY

RECORD GROUP NUMBER 156

Oil-Water Separator Design Checklist

Grease Interceptor Design Checklist

Related Drafting. (Construction related trades)

City of Lompoc Building & Safety Services Section 100 Civic Center Plaza Lompoc, CA Phone: Fax:

BUILDING PLAN REVIEW REQUIREMENTS

PINELLAS COUNTY CONSTRUCTION LICENSING BOARD

Students will learn to correctly prepare, assemble, and solvent weld ABS piping.

Facility Services Subgroup Preface for Divisions 21` through 28

TO WHOM IT MAY CONCERN:

Form No Assembly & Operating Instructions for: SAFETY PRECAUTIONS

JUDGING CRITERIA: Please refer to SkillsUSA Championships Technical Standards.

SECTION 39 - MANHOLES TABLE OF CONTENTS

CITY OF COLUMBIA DEPARTMENT OF UTILITIES AND ENGINEERING WASTEWATER COMPLIANCE FATS, OILS, AND GREASE REGISTRATION APPLICATION

Product Data (500) Wall thickness not to exceed 3"

GLENBROOK/GLENGUARD VITREOUS CHINA DRINKING FOUNTAIN/CUSPIDOR

7-1

Safety (OSHA 10 hour)

ASSIGNMENT 2. Textbook Assignment: 2-1. Levels are designed for which of the following purposes?

Plan Submittal and Review Checklist

OPERATING INSTRUCTIONS

Kitchen and Bath Design Planner

CRAFTSMAN EXAMINATION, JUNE 2008 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

SECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings

TYPE 3740XL EXTRA LARGE WET RUNNING CARTRIDGE SPLIT SEAL

New Multi-Family Buildings & Additions Plan Intake Submittal Checklist. Project Name: Site Address:

2250 S LOCUST APARTMENT IMPROVEMENTS EXPENSES

Non-Residential and Multi-Family Plan Check Submittal Requirements

Instructions for the installation of Handy Well Pump Models HWP-E, HWP and HWP-L. **Read thoroughly before you start!**

ADMINISTRATION DEPARTMENT Plant Management Division. An Inventory of Its State Office Building Drawings

COASTAL BEND COLLEGE WELDING SYLLABUS (Revised 8/10) Introduction to Blueprint Reading for Welders

LATTIMORE SHOWER SET INSTALLATION

PROJECT INSTRUCTIONS Roofing

TYPE 3740/3740D WET/DRY RUNNING CARTRIDGE SPLIT SEAL

WATER METERS M SERIES WATER METERS INSTALLATION, OPERATION AND MAINTENANCE GUIDE METAL M SERIES WATER METER PLASTIC M SERIES WATER METER

SECTION III SUBMITTALS AND APPROVALS

Prior to training with this module, it is recommended that the trainee shall have successfully completed Core Curriculum and Plumbing Level One.

B17. Sewer Site Plans BULLETIN

Technical Data February, 2016

Training Manual The Installation of Siphonic Pipework

CALLAS THERMOSTATIC SHOWER SET

Standard Specifications

M1.0 MECHNANICAL FLOOR PLAN

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series

Residential Construction Checklist Single and Two Family Construction

CSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

SUBMITTAL REQUIREMENTS FOR COMMERCIAL SIGNAGE PROJECTS

SECTION MECHANICAL IDENTIFICATION

SUBMITTAL REQUIREMENTS FOR COMMERCIAL BUILDING PROJECTS

Address: South Elgin, IL Phone: ( ) - Fax: ( ) - Cell: ( ) - Contractor Type: Phone: ( ) - Fax: ( ) - Cell: ( ) - Contact Type:

CHARLES COUNTY GOVERNMENT ITB NO ST. MARK S PUMP STATION UPGRADE

CITY OF LOVELAND HOMEOWNERS GUIDE FOR BUILDING PERMITS FOR HOME IMPROVEMENTS

SECTION MANHOLES

MAJOR GRADING PLAN CHECKLIST

BRASELTON WATER AND WASTEWATER DEPARTMENT CONSTRUCTION PLAN REVIEW CHECKLIST May 2006

ROOFING City of Grand Rapids Building Safety Division

Series 80 In-Line Mounted Centrifugal Pumps

SECTION FUEL OIL SYSTEM (PLUMBING)

PLUMBER APPRENTICESHIP PROGRAM

Installation and Maintenance Instructions

New Product Release: October 2014 Boone Racks

ADDENDUM #2 September 12, 2018

Single-Family Dwelling Submittal Requirements

Dewatering. Deep Wells Vacuum Wellpoints Eductor Wells Artesian Conditions System Design Water Treatment.

COMMERCIAL KITCHEN HOOD WORKSHEET/ CHECKLIST

Repair of Rotac Actuators

CUTTING THE PIPE: BLUE DUCT Pipe can be easily cut using a Circular Saw or Reciprocal Saw. Trim all edges as necessary.

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

SECTION 2 GENERAL REQUIREMENTS

Sheet Metal Worker Level 2

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

IX. FLARED JOINTS IX. FLARED JOINTS

WALKS AND SIDEWALKS REQUIREMENTS:

Residential Room Addition / Remodel Submittal Requirement Checklist

Series Inline Oscillating Saw

Transcription:

Chicago Plumber Licensure Examination Information This candidate guide should help you prepare for the Chicago plumber licensure examination. Part I contains general information about testing procedures. Part II outlines the content of the examination and recommends study materials. Part III includes sample questions to help you prepare for the test. Part I General Information PURPOSE OF THE EXAMINATIONS This examination is required for professional licensure of plumbers in the City of Chicago. You must pass this test to be licensed. TEST VALIDITY & TEST LENGTH The test is timed to be three hours in length. All test questions have been subjected to strict psychometric controls and reflect standards and practices validated by plumbers who are licensed in the City of Chicago. STUDY MATERIALS REFERENCES & CALCULATORS MISSING AN EXAMINATION SUCCESS/ LICENSURE FAILURE Study materials for this examination are described in Part II of this candidate guide. These sources may be purchased directly from the publishers, from Internet bookstores such as Amazon.com or Barnes and Noble (bn.com). References that may be required to answer questions on the test will be provided with the examination. No calculators or printed materials other than those provided at the test site may be used during the test. There are no "make-up" examinations. You may re-register for the next examination date. THERE ARE NO REFUNDS. Candidates who score 70 or higher will receive a PASS notice and an application for licensure. Candidates who score below 70 will receive a FAILURE notice and an application for re-examination. Candidates are encouraged to retake the examination; many candidates who initially fail such an exam pass on subsequent attempts. 2013, Continental Testing Services, Inc.

Page 2 Part II Test Content and Recommended Study Materials Plumbers must demonstrate that they are familiar with safe practices and procedures in their profession. Content areas and their relative importance in this test are outlined below. Relevant sections of the 2003 Chicago Plumbing Code are noted. Current editions of the Chicago Building Code also provide this information. I. Plumbing Theory, Practices & Job safety 20% of Examination Public health, Plumbing Math & Principles, Planning, Safety & OSHA Requirements, Tools & Equipment, Basic Electricity II. Code Requirements for Plumbers & Contractors 2% of Examination Chapter 4-332 III. Plumbing Systems 44% of Examination Chapter 18-29 Article I Administration Article II Definitions Article III General Regulations Article IV Fixtures, Faucets & Fixture Fittings Article V Water Heaters Article VI Water Supply & Distribution Article VII Sanitary Drainage Article VIII Indirect/Special Waste Article IX Vents Article X Traps, Separators and Interceptors Article XI Storm Drainage Article XII Swimming Pools IV. Rehabilitation Requirements 5% of Examination Chapter 13-200 420 Provisions for Buildings being Remodeled 460 Plumbing Requirements V. Drawings, Charts & Plans 8% of Examination Reading Blueprints, Locating Fixtures, Completing Building Plans to Code VI. Cutting & Assembling Plumbing System Components 12% of Examination Water Flow & Connection Requirements Materials, Sizing & Drainage Requirements Using Copper, Steel, Cast Iron, Plastic & Acid-Resistant Materials VII. Troubleshooting, Maintenance & Repairs 10% of Examination Repairing Fixtures & Appliances, Waste-Water Systems, Water Distribution Systems, Drainage & Vent systems

Page 3 Recommended Study Materials All questions in this examination are based on information provided in the following sources. Therefore, all candidates should become as familiar as possible with each of these references in preparation for this examination. Some information from these references that may be required to answer questions on the test will be provided with the examination. However, no calculators or printed materials other than those provided at the test site may be used during the test. Most publishers will accept telephone orders to be charged to a VISA, Mastercard or American Express account. These references also may be available from Internet bookstores such as Amazon.com or Barnes and Noble (bn.com). 1. 2006 Chicago Plumbing Code (Also available in current edition of Chicago Building Code; see content outline to identify relevant sections) Publisher Index Publishing Company Phone: (312) 644-7800 415 North State Street, Chicago, IL 60610 Website http://www.lawbulletin.com 2. Blankenbaker, E. Keith. Modern Plumbing, 6 th Edition (2005). Publisher Goodheart-Willcox Company, Inc. Phone: (708) 687-5000 18604 West Creek Drive, Tinley Park, IL 60477-6243 Website http://www.goodheartwillcox.com 3. Ripka, L.V., Plumbing Design and Installation, 3 rd Ed. (2006). Publisher: American Technical Publishers Phone: (708) 957-1100 1155 West 175th Street, Homewood, IL 60430 Website http://www.americantech.org 4. Smith, Lee, Guest, J. Russell, D Arcangelo, Bartholomew, & D Arcangelo, Benedict, Mathematics for Plumbers and Pipefitters, 7 th Ed., (2008) or 6 th Edition, (2004). Publisher: Delmar Publishing Company Phone: (800) 347-7707 Website: http://www.delmar.com 5. Guest, J. Russell, D Arcangelo, Bartholomew, & D Arcangelo, Benedict, Blueprint Reading and Drafting for Plumbers, 2 nd Ed, (2009) Available July 2008. Publisher: Delmar Publishing Company Phone: (800) 347-7707 Website: http://www.delmar.com 6. McConnell, Charles N., Audel Plumbers Pocket Manual, 10 th Edition ( 2004) Publisher: Macmillan Publishing Company Phone: (800) 755-7672 273 Polly Drummond Road, Newark, DE 19711

Page 4 Part III Sample Test All questions on these examinations are multiple choice with one correct answer and three incorrect choices. For this sample test only, correct answers and references are provided at the end of this section to help you prepare for is examination. 1. Which term refers to the point at which material removed from a trench will stay without sliding back into the trench? A. Excavation B. Trench shield C. Angle of repose D. Trench shoring 2. How many gallons of water are required to fill 2500 feet of a 6-inch water main? A. 306 B. 2447 C. 2255 D. 3670 3. Which of these is appropriate for use on fires involving flammable liquids such as gasoline, grease and oil? A. Class A fire extinguishers marked with a green triangle B. Class B fire extinguishers marked with a red square C. Class C fire extinguishers marked with a blue circle D. Class D fire extinguishers marked with a yellow star 4. What does the Chicago Plumbing Code specify prior to a service pipe inspection? A. The entire service pipe must be left accessible until after the inspection. B. The service pipe must be left exposed only within five feet of each end. C. The service pipe trench should be filled with stand and compacted with water. D. The service pipe must be supported by compacted sand prior to the inspection.

Page 5 5. What does the Chicago Plumbing Code specify for underground piping with solder joints? A. Silver brazing alloys B. 95/5 tin-antimony solder C. Any solder with less than 8% lead content D. Any solder with lead content equal to or less than 0.2% 6. Which of these does the Chicago Plumbing Code define as a minor repair? A. Replacing a broken house drain B. Removing obstructions from soil and sewer pipes C. Reinstallation of fixtures during a remodeling project D. Installation of new fixtures during a remodeling project 7. What does the Chicago Plumbing Code specify as the depth of a sump or receiving tank? A. A minimum of 30 inches B. A maximum of 30 inches C. A minimum of 36 inches D. A maximum of 42 inches 8. What does the Chicago Plumbing Code specify as the maximum horizontal length between a trap and its vent? A. 18 B. 24 C. 30 D. 60 9. What do Chicago Plumbing Code specifications require for the grease retention capacity of a grease interceptor or a grease trap? A. Capacity in pounds of grease retained must be twice the flow rate in gpm for the sink or receptor served. B. Capacity in pounds of grease retained must equal the flow rate in gpm from the sink or receptor served. C. At least 75% of the grease received must be retained. D. At least 98% of the grease received must be retained.

Page 6 10. What does the Chicago Plumbing Code specify for handicapped accessibility when doors are being replaced in a remodeled residential building that must meet the Rehabilitation Code? A. Any door that is replaced must be at least 32" wide. B. Any door that is replaced must be at least 30" wide. C. Doors to toilet rooms must be at least 32" wide. D. Doors to toilet rooms must be at least 30" wide. 11. Who determines what information is in rough-in sheets? A. The architect B. The building contractor C. The plumbing contractor D. The fixture manufacturer 12. Which of these is the architectural symbol for a soldered sanitary T? 13. What is the total pitch on a 75' long drain line that is installed at a grade of 3 / 4 " per 10'? A. 4 7 / 8 " B. 5 5 / 8 " C. 6 3 / 8 " D. 7 1 / 2 " 14. What is the pressure on test plug at the base of a 32' high stack when it is filled with water? A. 10.42 psi B. 13.89 psi C. 18.23 psi D. 62.50 psi

Page 7 15. Which of these accurately describes the drinking fountain in the above diagram? A. It is individually vented. B. It is crown vented. C. It is stack vented. D. It is not vented. 16. What should happen after a combination thermostat and EOC opens in an electric water heater? A. The thermostat should reset itself automatically. B. The heating elements must be recalibrated. C. The combined unit must be reset manually. D. The EOC must be replaced immediately. 17. Which of these is LEAST likely to cause a submersible pump to deliver little or no water while it operates? A. Worn pump parts B. A loose motor shaft C. Defective motor wiring or cable D. A pump intake screen blocked by mud or sand

Question 18 refers to the following diagram. Page 8 18. What is the end to end length of pipe W if H 1 measures 4'-7 1 / 2 ", H 2 is 3'-4", the vertical measure is 5'-11 1 / 2 ", and each offset is 10" for an assembly using 2" threaded pipe? A. 4'-7 1 / 2 " B. 4'-6 1 / 2 " C. 4'-8 3 / 4 " D. 4'-9 3 / 4 " Correct Answers and References Correct Question Answer References (See list on page 3 of this study guide) 1 C Blankenbaker page 37, Ripka (1994) page 19 2 D Blankenbaker pages 48-49, Smith pages 9, 168, 172 2500' = 30,000"; Vol = (30,000" x 3 2 x )/231 cu in/gal=3670 gallons 3 B Blankenbaker pages 34-35 4 A 2002 Chicago Building Code 18-29-601.2 & 601.3 5 D 2002 Chicago Building Code 18-29-605.14.3 6 B 2002 Chicago Building Code 18-29-202 7 A 2002 Chicago Building Code 18-29-1111.3 8 D 2002 Chicago Building Code 18-29-906.1 9 A 2002 Chicago Building Code 18-29-1003.3.6 & 1003.3.3 10 C 2002 Chicago Building Code 13-200-420 11 D Ripka (1994) pages 264-80, Guest pages 137-151 12 B Blankenbaker pages 108-109 13 B Smith pages 118-120;.75" x 75'/10' =.75" x 7.5 = 5.625" = 5 5 / 8 " 14 B Smith page 178; 32 x 0.434 psi = 13.89 psi 15 A Blankenbaker pages 123-127; Ripka (1994) pages 138-142 16 C McConnell page 18 17 C McConnell pages 147-150 18 D Smith pages 79-85, 218, 223, 234; W: c-c = 71 1 / 2 " 10" = 61 1 / 2 " e-e = 61 1 / 2 " [( 1 11 / 16 + 3 1 / 16 ) 2 ( 1 / 2 )]= 61 1 / 2 " 3 3 / 4 " = 57 3 / 4 " = 4' 9 3 / 4 "