Artigo Original. Development and commissioning of a test system based on a TEM cell for RF exposure

Similar documents
INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

A GTEM BEST PRACTICE GUIDE APPLYING IEC TO THE USE OF GTEM CELLS

Comparison of IC Conducted Emission Measurement Methods

E-Field Uniformity Test Volume In Gtem Cell Based On Labview

A Complete Simulation of a Radiated Emission Test according to IEC

Localization and Identifying EMC interference Sources of a Microwave Transmission Module

Electromagnetic Compatibility ( EMC )

Road vehicles Component test methods for electrical disturbances from narrowband radiated electromagnetic energy. Part 3:

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

Transient calibration of electric field sensors

Modeling and Practical Suggestions to Improve ESD Immunity Test Repeatability

Physical RF Circuit Techniques and Their Implications on Future Power Module and Power Electronic Design

MEASUREMENTS OF COUPLING THROUGH BRAIDED SHIELD VIA NEW CONDUCTED IMMUNITY TECH- NIQUE

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

Internal Model of X2Y Chip Technology

Double-Ridged Waveguide Horn

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

GTEM For emission and immunity testing according to IEC/EN Introduction

Performance Analysis of Different Ultra Wideband Planar Monopole Antennas as EMI sensors

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

Γ L = Γ S =

Correlation Between Measured and Simulated Parameters of a Proposed Transfer Standard

2/18/ Transmission Lines and Waveguides 1/3. and Waveguides. Transmission Line A two conductor structure that can support a TEM wave.

SENSITIVITY AND UNCERTAINTY ANALYSIS FOR CALCULABLE ANTENNA FACTOR OF THE DIRECT-FEED BICONICAL ANTENNA

Final Report. Bilateral Comparison on Electric Field Measurements Between TÜBİTAK UME and SASO NMCC GULFMET.EM.RF-S1. UME-EM-D

Suppression Techniques using X2Y as a Broadband EMI Filter IEEE International Symposium on EMC, Boston, MA

Trees, vegetation, buildings etc.

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

EE 3324 Electromagnetics Laboratory

9 Specifications. Specifications NOMINAL CHARACTERISTICS

The Measurement and Uncertainty Analysis of Antenna Factor of Microwave Antennas Based on Standard Site Method

EMC Amplifiers Going Beyond the Basics to Ensure Successful Immunity Tests

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

A Study of Conducted-Emission Stable Source Applied to the EMC US and EU Standards

DESIGN OF A NOVEL BROADBAND EMC DOUBLE RIDGED GUIDE HORN ANTENNA

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

COAXIAL / CIRCULAR HORN ANTENNA FOR A STANDARD

INVESTIGATION OF THE LONGITUDINAL FIELD COMPONENT INSIDE THE GTEM 1750

Verifying Simulation Results with Measurements. Scott Piper General Motors

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/157

Measuring the EMC on RF-connectors and connecting hardware. Tube in tube test procedure

Predicting Module Level RF Emissions from IC Emissions Measurements using a 1 GHz TEM or GTEM Cell A Review of Related Published Technical Papers 1

Politecnico di Torino. Porto Institutional Repository

INVENTION DISCLOSURE- ELECTRONICS SUBJECT MATTER IMPEDANCE MATCHING ANTENNA-INTEGRATED HIGH-EFFICIENCY ENERGY HARVESTING CIRCUIT

GTEM cells. Emissions and immunity testing in a single, shielded environment

Broadband and Gain Enhanced Bowtie Antenna with AMC Ground

Course Introduction Purpose Objectives Content Learning Time

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

GTEM For emission and immunity testing according to IEC/EN Introduction

Design of a Rectangular Spiral Antenna for Wi-Fi Application

Methodology for MMIC Layout Design

Microstrip Filter Design

Application Note 5525

Analysis of a Co-axial Fed Printed Antenna for WLAN Applications

EMC Seminar Series All about EMC Testing and Measurement Seminar 1

Analysis of Crack Detection in Metallic and Non-metallic Surfaces Using FDTD Method

Technology in Balance

Characterization of medical devices electromagnetic immunity to environmental RF fields.

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

COMPACT DESIGN AND SIMULATION OF LOW PASS MICROWAVE FILTER ON MICROSTRIP TRANSMISSION LINE AT 2.4 GHz

INTERNATIONAL STANDARD

Methods for Evaluating the Shielding Effectiveness of Textiles

FISCHER CUSTOM COMMUNICATIONS, INC.

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

AMPLIFIER RESEARCH... APPLICATION NOTE: 20

Optimized shield design for reduction of EMF from wireless power transfer systems

Overview of the ATLAS Electromagnetic Compatibility Policy

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

Investigation of a Voltage Probe in Microstrip Technology

THE TWIN standards SAE J1752/3 [1] and IEC 61967

High frequency electomagnetic field irradiation. Andrea Contin

Screening Attenuation of Long Cables

Evaluating VNA post-calibration residual errors using the ripple technique at millimetre wavelengths in rectangular waveguide

Lab E2: B-field of a Solenoid. In the case that the B-field is uniform and perpendicular to the area, (1) reduces to

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

THE ELECTROMETRIC AC-DC TRANSFER STANDARD AS PRIMARY STANDARD AT IEN FOR AC VOLTAGES FROM 300 V TO 1000 V

A New TEM Horn Antenna Designing Based on Plexiglass Antenna Cap

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY DHAB S/124

ATSC 3.0 Ready Designing Antennas for Higher OFDM PAPR

TECHNICAL REPORT: CVEL Special Considerations for PCB Heatsink Radiation Estimation. Xinbo He and Dr. Todd Hubing Clemson University

TRANSMITTING ANTENNA WITH DUAL CIRCULAR POLARISATION FOR INDOOR ANTENNA MEASUREMENT RANGE

University of Pennsylvania Department of Electrical and Systems Engineering ESE319

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

Analysis of a PCB-Chassis System Including Different Sizes of Multiple Planes Based on SPICE

Design a U-sloted Microstrip Antenna for Indoor and Outdoor Wireless LAN

Waveguides. Metal Waveguides. Dielectric Waveguides

Characteristics of Biconical Antennas Used for EMC Measurements

Introduction: Planar Transmission Lines

An explanation for the magic low frequency magnetic field shielding effectiveness of thin conductive foil with a relative permeability of 1

Higher Order Mode Suppression in Triaxial Cells

Analysis and design of microstrip to balanced stripline transitions

Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference

Effectively Using the EM 6992 Near Field Probe Kit to Troubleshoot EMI Issues

SHIELDING EFFECTIVENESS

Electromagnetic Compatibility

Design of back-to-back tapered line transition

Considerations about Radiated Emission Tests in Anechoic Chambers that do not fulfil the NSA Requirements

Critical Study of Open-ended Coaxial Sensor by Finite Element Method (FEM)

Transcription:

Volume 27, Suplemento 1, p. 25-30, 2011 Artigo Original DOI: 10.4322/rbeb.2012.012 Development and commissioning of a test system based on a TEM cell for RF exposure Daniele Desideri, Alvise Maschio* Abstract In the development of a low-cost two-port TEM cell, a new analytical model of the capacitance of the terminations has been performed. The model has been verified by calcula ting the termination capacitance by means of a commercial 3D code. A TEM cell modified in accordance with the obtained results has been tested, with reference to the voltage standing wave ratio (VSWR) parameter, and the obtained improvements on VSWR versus frequency are reported. The TEM cell is the principal part of a test system for RF exposure (up to 230 MHz), including signal generator, power amplifier, dual directional coupler, 50 Ω load attenuator and 1 GHz bandwidth oscilloscope, whose commissioning has been performed. A numerical analysis has been performed also for calculating the stationary electric field in the TEM cell. Experimental measurements of electric field inside the TEM cell, by means of an electric field meter (100 khz - 6 GHz broadband) were done, and the results are in good agreement with the numerical data. Keywords TEM cell, VSWR measurements, Electric field measurements, Biological RF test system. Desenvolvimento e comisssionamento de um sistema de teste baseado em célula TEM para exposição RF Resumo Este trabalho descreve o desenvolvimento de um célula TEM de baixo custo com duas portas. Um novo modelo analítico para as capacitâncias de suas terminações é também demonstrado. O modelo foi avaliado calculando-se a capacitância da terminação por meio de um código de análises de elementos finitos 3D comercial. Uma célula TEM modificada de acordo com os resultados foi testada, e as melhorias obtidas em termos da taxa de onda estacionária de tensão (TOET) em relação à frequência são descritas. A célula TEM é a parte principal de um sistema de teste para exposição de RF (até 230 MHz), que inclui ainda gerador de sinais, amplificador de potência, acoplador direcional dual, atenuador de carga de 50 Ω e um osciloscópio com largura de banda 1 GHz. A análise numérica foi também realizada para o cálculo do campo elétrico estacionário na célula TEM. Um medidor de campo elétrico (100 khz - 6 GHz) foi utilizado para medições experimentais no interior da célula TEM, e os resultados obtidos mostraram ser concordantes com os dados numéricos. Palavras-chave Célula TEM, Medições de TOET, Medições de campo elétrico, Sistema de teste RF. *e-mail: alvise.maschio@dii.unipd.it Recebido: 04/02/2010 / Aceito: 16/07/2010

26 Desideri D, Maschio A Introduction TEM cell is a way of producing a plane electromagnetic wave with known characteristics and good accuracy in a shielded environment; moreover high electric field values are obtained with a low cost system. Originally proposed in 1974 (Crawford, 1974), it is now largely used for calibration of RF probes (Italian guide CEI, 2001), and in the electromagnetic compatibility field (International..., 2003). Biomedical applications are important too, both for thermal and non-thermal effects investigation (Dlugosz and Trzaska, 2006; Popovic et al., 1998; Racuciu et al., 2007; Wu et al., 2007). A rectangular coaxial two-port TEM cell for RF analyses has been designed and built at the Department of Electrical Engineering of the University of Padova; the design criteria and the results of preliminary tests were reported in (Desideri et al., 2007; Desideri and Maschio, 2008). The critical effects of the shape of the septum terminations were put in evidence by the preliminary tests, so that a very careful evaluation of the capacitance of the terminations, which is the fundamental parameter in determining the characteristic impedance of this part of the TEM cell, has been performed. In this paper the analytical model used for the evaluation of the termination capacitance is presented. The results of the calculations performed with a commercial 3D code for the validation of the analytical calculations and the evaluation of the pattern of the electric field inside the TEM cell are also presented. Further, the procedure for the commissioning of the test system is reported, and the main experimental results in terms of Voltage Standing Wave Ratio (VSWR) and electric field pattern are presented. Final remarks and conclusions are given in the end. Methods Termination capacitance: analytical model The TEM cell was designed for a maximum size of equipment under test (EUT) of about 270 220 60 mm (Desideri et al., 2007). The planned highest test frequency with only a TEM mode was 230 MHz. A schematic outline of the TEM cell with the indication of the reference axes is given in Figure 1. The dimensions of the central part of the TEM cell are given in the following: cell width a = 450 mm; septum width w = 364 mm; distance between the septum and the floor h = 179.25 mm; length L = 462 mm, giving a maximum EUT of 0.6 L 0.6 w 0.33 h (Standard IEC 61000-4-20). The septum is in brass, 1.5 mm thick, with a final part in copper, 0.6 mm thick. The quality of the TEM cell is related to the VSWR, which is defined as: 1 +Γ VSWR = 1 Γ (1) where Γ is the ratio between the amplitudes of the reflected voltage wave and the incident voltage wave respectively: a value of VSWR not greater than 1.2 can be considered as good. An improved version has been developed in order to achieve a value of VSWR not greater than 1.2 in Figure 1. Side view and cross-section of the TEM cell outline with reference axes.

Development and commissioning of a test system 27 the largest possible frequency range of the TEM cell. The analysis has been focused on the terminations. A detailed analytical evaluation of the capacitances of the terminations has been performed, considering both a distributed capacitance along the termination length and a concentrated frontal edge capacitance at the end of the termination, in order to obtain a characteristic impedance, in the average, equal to the value of the central part (50 Ω). Distributed termination capacitance The terminations of the septum have been well centered and precisely filed to the correct value according to the formula of the capacitance per unit length (C l ) (Cruzan and Garver, 1964): Figure 2. Rectangular cross-section of the terminations. 2 π g * C = 4ε 0 ln 1+ coth + π 2 h * + b * w* b* 2ε 0 + 2ε 0 = C 1+ C 2 + C 3 h* g* (2) where the quantities b*, h*, w*, g* are shown in Figure 2, which shows the rectangular cross-section of the terminations. The formula is the sum of three terms. The term C l2 is the contribution due to the central part and the term C l3 is the side contribution due to the septum thickness: both derive from the parallel plate capacitance equation. The term C l1 instead is related to the edge effect, which is not included in the other two terms. In this TEM cell, with b* = 0.6 mm, h* = 17.7 mm, w* = 35.6 mm, g* = 4.7 mm, C l is equal to 66.6 pf/m. Frontal edge capacitance A rectangular septum termination is assumed in Figure 3. A central side view of the septum termination is reported in Figure 3a. The configuration is similar to the one depicted in Figure 2 and therefore (3), derived from (2), has been used for the estimation of the frontal edge capacitance: 2 πd b* C = 2ε ln 1+ coth +ε w* 0 0 π 2 h* + b* d (3) where the quantities b*, d, h* and w* are shown in Figure 3. The values of b*, h* and w* are given below. This frontal edge capacitance has been divided by the distance d, and the result has been treated as a capacitance per unit length: the hypothesis was that, taking its value equal to the C l of (1), a 50 Ω characteristic impedance could be obtained. With d equal to 1 mm and 7 mm respectively, and Figure 3. TEM cell: a) central side view, and b) central plan view. the other parameters as previously taken, frontal edge capacitances C equals to 1.20 pf and 0.45 pf respectively were found. It is noticed that the ratio of C/d, with d equal to 7 mm, is almost equal to

28 Desideri D, Maschio A the Cℓ previously reported. In addition, in order to obtain a gradual connection between the septum and the connector, a linear termination (dashed line in Figure 3b), has been adopted. The hypothesis was that this triangular geometry with height 2d had almost the same capacitance of the rectangular septum termination with distance d. Results TEM cell: DC numerical analysis When x = 0 mm, the module of z component of the electric field is about 10% higher at z = 80 mm than at z = 150 mm. The numerical data at x = 90 mm are almost equal to the ones at x = 0 mm (Figure 4). Commissioning of the test system The test system set-up is shown in Figure 5. A signal generator with a power RF amplifier (35 W nominal output CW power, 10 khz - 250 MHz frequency response) is connected to the TEM cell by a dual directional coupler (10 khz - 400 MHz frequency A 3D finite element commercial code (Maxwell 3D) has been used in stationary conditions for a comparison with (2) and for the evaluation of the stationary electric field inside the TEM cell. Frontal edge capacitance: numerical analysis A first numerical analysis has been performed considering only the terminations of the TEM cell, joined together, and evaluating the capacitance between the septum and the outer conductor. In this case the total capacitance value is due to the contribution of the two frontal edge plus the two distributed termination capacitances. At first, the geometry depicted in Figure 3b (continuous line), and including the septum transition between brass and copper, has been numerically analyzed, in two cases: with d equal to 1 mm (and length of 124 mm) and d equal to 7 mm (and length of 112 mm). The resulting capacitances were of 10.7 pf and 8.4 pf respectively, in very good agreement with the values obtained by the analytical formulas. Then the numerical analysis of the geometry depicted in Figure 3b (dashed line - gradual connection) has been considered (including the hole for the connector) and the result compared with the equivalent rectangular septum termination, with the same area. The triangular geometry with height 2d has almost the same capacitance of the rectangular septum termination with distance d (Figure 3). Figure 4. Electric field at a) x = 0 mm, and b) x = 90 mm. 3D numerical analysis of the TEM cell The same code has been used for the numerical calculation of the electric field with the complete geometry of the TEM cell. About sixty thousands tetrahedra have been used in the simulation and Figures 4a,b show some results at x = 0 mm and x = 90 mm respectively. The z and y components of the electric field are shown, while the x component has not been reported, being negligible in both cases. The numerical data have been calculated with a voltage of 1 V between septum and outer conductor. Figure 5. RF test system.

Development and commissioning of a test system range). The voltages proportional to the incident and reflected voltage waves are reported on a 1 GHz bandwidth oscilloscope. On the other port of the TEM cell a 50 Ω load attenuator is connected and the voltage signal is shown on the oscilloscope. The frequency range of the test system is 10 khz - 230 MHz. For the measurement of the electric field inside the two-port TEM cell, an electric field probe (100 khz - 6 GHz broadband) has been used. VSWR measurements The VSWR has been measured; the values obtained are reported as a function of frequency in Figure 6. The values have been measured with linear terminations (Figure 3b), at different values of d. The frequency range, where VSWR is not greater than 1.2, increases with d from 2.5 mm up to 5 mm; it remains almost constant from 5 to 7 mm. The maximum frequency, with VSWR not greater than 1.2, has been obtained at 177 MHz. At the highest frequencies, the best values of VSWR were obtained with d = 7 mm. Figure 6. VSWR vs frequency. Electromagnetic field measurements The electric field has been measured in a few positions by means of an electric field meter (100 khz - 6 GHz broadband) (Figure 7). The probe has a cubical house 32 mm side and three sensor-protection caps 43 mm height. In the following, the nominal measurement point is the barycentre of the cubical housing. The not negligible dimensions of the sensors may give a difference between measured and actual value in the reference measurement point. The measurements have been done at two frequencies (50 MHz and 180 MHz), under the septum at two heights (z = 150 mm and z = 80 mm), at two different sections (the central one, i.e. x = 0, and at x = 90 mm), and at two values of y (y = 0 and at a distance of 115 mm from the lateral sides of the TEM cell). All the reported values are RMS values, and measurements have been performed keeping a 25 VRMS voltage at the 50 Ω load attenuator. The measured data are in good agreement with the stationary numerical results. As an example, at x = 0, y = 0, the z-component of the electric field has been measured equal to 136 V/m (f = 50 MHz) and 143 V/m (f = 180 MHz) at z = 150 mm, while at z = 80 mm, it resulted equal to 153 V/m (f = 50 MHz) and 164 V/m (f = 180 MHz), with corresponding numerical results, scaled at 25 V, of 128 V/m at z = 150 mm and 142 V/m at z = 80 mm. Figure 7. Electromagnetic field test probe. Conclusions The improvement in the design and construction of a low-cost two port TEM cell has been described. The two terminations of the TEM cell have been modified according to a design criterion based on analytical formulas verified with a 3D computer simulation. The TEM cell has been included in an RF (up to 230 MHz) exposure test system, whose commissioning is reported. In particular, values of VSWR not greater than 1.2 have been measured in a large part of the frequency range (up to 177 MHz). The electric field inside the TEM cell have been calculated by a stationary 3D code and the numerical results have been experimentally validated. With such a system, studies of the effects, both thermal and non-thermal, on biologic samples can be performed. 29

30 Desideri D, Maschio A References Comitato Elettrotecnico Italiano - CEI. CEI 211-7: guide for the measurement and the evaluation of electromagnetic fields in the frequency range 10 khz - 300 GHz, with reference to the human exposure. Milano: CEI; 2001. In italian. Crawford ML. Generation of standard EM fields using TEM transmission cells. IEEE Transactions on Electromagnetic Compatibility. 1974; 16(4):189-95. http://dx.doi.org/10.1109/ TEMC.1974.303364 Cruzan OR, Garver RV. Characteristic impedance of rectangular coaxial transmission lines. IEEE Transactions on Microwave Theory and Technique. 1964; 12(5):488-95. http://dx.doi.org/10.1109/tmtt.1964.1125864 Desideri D, Maschio A. Preliminary tests on a low cost two-port TEM cell. Acta Electrotehnica. 2008; (Special Issue):298-301. Desideri D, Maschio A, Zuccato A. Design of a new low cost two-port TEM cell. In: ISEF 2007: Proceedings of the 13th International Sympium on Electromagnetic Fields in Mechatronics, Electrical and Electronic Engineering, 2007, Prague. ISBN 978-80-01-03784-3. Prague; 2007. Dlugosz T, Trzaska H. TEM cell in biomedical experiments. In: EMFS: Proceedings of the 4th International Workshop on Biological Effects, 2006, Crete. Crete; 2006. v. 1, p. 89-95. International Electrotechnical Commission - IEC. Electromagnetic compatibility (EMC) - part 4-20: testing and measurement techniques - emission and immunity testing in transverse electromagnetic (TEM) waveguides. IEC; 2003. IEC 61000-4-20. Geneva. Popovic M, Hagness SC, Taflove A. Finite-difference timedomain analysis of a complete transverse electromagnetic cell loaded with liquid biological media in culture dishes. IEEE Transactions on Biomedical Engineering. ; 45(8):1067-76, 1998. PMid:9691582. http://dx.doi.org/10.1109/10.704876 Racuciu M, Miclaus S, Creanga DE. Non thermal continuous and modulated RF field effects on vegetal tissue developed from exposed seeds. In: EHE 07: Proceedings of the 2nd International Conference on Electromagnetic Fields, Health and Environment, 2007, Wroclaw. Amsterdam: IOS Press; 2008. p. 142-48. Wu B-I, Cox FCAI, Kong JA. Experimental methodology for non-thermal effects of electromagnetic radiation on biologics. Journal of Electromagnetic Waves and Applications. 2007; 21(4):533-48. http://dx.doi.org/10.1163/156939307780616829 Authors Daniele Desideri, Alvise Maschio Department of Electrical Engineering, University of Padova, Via Gradenigo 6/a, I-35131, Padova, Italy