Direct solenoid and solenoid pilot operated valves

Similar documents
Pressure Transducer FP2000

Proportional pressure controller

MATHCOUNTS. 100 Classroom Lessons. August Prepared by

Proportional pressure controller

FX-500 Low Jitter Frequency Translator

FX-700 Low Jitter Frequency Translator

Proportional pressure controller. Pressure range PSI/BAR. D Differential pressure G Gage pressure X X X - X X. Cover options

1905 LMI. Transmission Laser Modules. KeyFeatures Up to 20mW output power. Applications. For moreinfo

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Proportional pressure controller

Bloodhound Working Dog (16/pp) quiltartdesigns.blogspot.com

Directional valves Electrically operated Series 563, 565, 567. Brochure

Power Distribution Module 54.05

Proportional pressure controller

Lower ground floor information

FINDINGS. May 2, Courtney Wilton Portland Public Schools 501 North Dixon Portland, Oregon 97227

DF-Series Pneumatic Couplings

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

190S A N D 2 C A16 C TE

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

S-band 500kW Magnetron

5 to 220 Volt DEVICES FOR BIPOLAR APPLICATIONS

MOBY-D Family Matrix

190S A N D 2 C A16 C TE

SMBJ5.0 THRU SMBJ440CA

Description. Block Diagram LFN (6) Charge Pump. Feedback Divider CBRCLK (4) Figure 1. Functional block diagram

Desktop I/O Simulator

MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS THE FUTURE OF CONTROL TM

STANDARD ELECTRIC LINEAR SERVOACTUATION PACKAGES

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Direct Operated Proportional DC Valve Series D1FP

600W SURFACE MOUNT TRANSIENT VOLTAGE SUPPRESSOR SMB(DO-214AA) PACKAGE. SMBJ Series WILLAS ELECTRONIC CORP.


Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Designs (PD) LD P KER CHIPS

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 6410A

4Post Trakslider Instructions

Electronically controlled proportional pressure regulating valves

Transient Voltage Suppressors (TVS) Data Sheet

Inscription Area/Color Labeling Accessories W H Order No. Price Packing Illustration Description mm mm 1 Pkg. 1 Pkg.

Function Block DIGITAL PLL. Within +/- 5ppm / 10 years (Internal TCXO Stability) 1 External Reference Frequency Range: 10MHz +/- 100Hz

THE FUTURE OF CONTROLTM MM1/MM2 CONTROL VALVES CLOSED LOOP PROPORTIONAL PRESSURE CONTROLS

PT7M7803/ / μp Supervisor Circuits

V26 Chassis Part Replacement Instructions Optical Engine Electrical Chassis HDD (PVR) PWB s

Rosen Aviation Capability List

PT7M CL/CH /NL Voltage Detector

Standard Coils and Proportional Valve Coils

MIL-Spec Application Guide

PROPORTIONAL PRESSURE CONTROLS TECNORD

WO 2008/ A3 PCT. (19) World Intellectual Property Organization International Bureau

FX-702 Low Jitter VCSO Frequency Translator Previous Part Numbers FX-703, FX-730

3RH1 contactor relays, 4- and 8-pole

February Superfast Surrey - Gainshare Deployment Postcodes

Red: PAINTED ITEMS Blue: KITS IPDA2

4/3 Proportional Directional Valve, Size SAE 10

PROPORTIONAL PRESSURE CONTROLS TECNORD

!"#$%& '()#"#-#"*+,(-# «!"#$% " $&'()*+,$)& -."/01*&$"2 3' $+ 8'$/"$+». -(/+% &'*"%0 (1'#&# 2*'(0,.#-%'3 % #"*+,(-#

Proportional Directional Valves with Feedback KBFDG4V-5-2C75N45-Z-M1-PC7-H7-12-EN123/EN150. Pressures to 315 bar (4500 psi)

Document # Logos: Purch-11B Purchasing Use ONLY: How to Change a Vendor in Logos Original Author Karrie Revolinski Date 5/10/13 Updated Author Date

Single Zener diodes in a SOD323F package. Table 1. Quick reference data Symbol Parameter Conditions Min Typ Max Unit V F forward voltage I F = 100 ma

7) 1. Nf7# 8) 1. Nf8# 9) 1. Nd6# 10) 1... exd4# 11) 1. Rc7# 12) 1. Rc4# 7) 1. Ne4# 8) 1... Rxg3# 10) 1. Bxb5# 11) 1... Rc2# 12) 1.

SONET / SDH. Block Diagram. COutput Output XTAL HPLL. Figure 1 - Block Diagram

Transient Voltage Suppression Diodes Surface Mount 600W > SMBJ series. SMBJ Series. SMBJ Series

Light-strip indicator

March 1, Courtney Wilton Portland Public Schools 501 North Dixon Portland, OR 97227

RESET output (push-pull)

5 to 70 Volt DEVICES FOR BIPOLAR APPLICATIONS

INSTALLATION INSTRUCTION Supersedes: N1.8Y (399) N1.8Y (699)

IB IL 24/230 DOR 4/W-PC IB IL 24/230 DOR 4/W-PC-PAC

How to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

DIN (NFPA/ISO/CETOP) NG6 (3) NG10

SMBJ SERIES RTCA DO-160G COMPLIANT PRODUCT 600 WATT TVS COMPONENT APPLICATIONS DO-214AA PACKAGE MECHANICAL CHARACTERISTICS FEATURES PIN CONFIGURATIONS

Visa Smart Debit/Credit Certificate Authority Public Keys

1943 RAM. Ultra-Low Power Consumption

3TK28 Safety Relays. General data. 7/70 Siemens LV

Transient Voltage Suppression Diodes Surface Mount 600W > SMBJ series

Open Type Without Enclosure

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

MODEL 1450A/02-AH Synthesizer

Transient Voltage Suppression Diodes Surface Mount 600W > SMBJ-HR series. Bi-directional. Features 5.0 W 100 A 3.5V/5.0 V. -55 to 150 C 20 C/W

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

DATASHEET 1943 RAM. Active Components Pump Laser Modules 1064 CHP Key Features. Applications. For moreinfo

CG1-N C02-3 CM1-N B02-3 CM1-N C02-3 CP1-N C01-3 CP2-N C01-3

Base Mounted Plug-in Unit

D.C. Hydraulic Power Systems

Single Zener diodes in a SOD123 package

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Electronic Pressure Measurement

Open Type Without Enclosure

Alcatel 1915 LMM WDM ps/nm application 10 Gbit/s digital Laser Module with integrated electro-absorption Modulator

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

DATA SHEET. BZX884 series Voltage regulator diodes DISCRETE SEMICONDUCTORS. Product data sheet Supersedes data of 2003 May Mar 26 BOTTOM VIEW

LD ma very low quiescent current linear regulator IC. applications. Description. Features SOT23-5L. DFN4 1x1

An Application for a CPCN for the Okanagan Transmission Reinforcement (OTR) Project No

Electrohydraulic Actuator Type PVEP / PVEP-F

Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Ceramic Chip Capacitors / Array SAMPLE KIT. Product-ID: CC-E12

Passage Desking System

SONET / SDH. Block Diagram. COutput Output XTAL HPLL. NC OE Gnd. Figure 1 - Block Diagram

Transcription:

Direct solenoid and solenoid pilot operated valves Series 5 Individual mounting Series Inline Bonded spool Air return Manual operator Solenoid 4-way pilot with balanced poppet 33 34 36 3 37 38 5 67 69 44 46 4 47 48P 3 1 48 400 9 SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Various manual operators. Optional memory spring. Normally closed or normally open valve function. May be plugged for -way operation. Internal or external pilot. 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 63 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 5 SPOOL CONFIGURATIONS INTERNAL PILOT 10 1 INTERNAL PILOT 10 1 NORMALLY CLOSED 3 WAY NORMALLY OPEN 3 WAY 64 Consult Precautions page 37 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series 5 Function Port size Flow (Max) Individual mounting Series 3/ NO-NC, / NO-NC 1/8-1/4 1.5 C v Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting force both ways.. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Port size 1/8 NPTF 1/4 NPTF 1/8 NPTF 1/4 NPTF Pilot air Internal External SOLENOID OPERATOR 10 NO Valve 3 1 1 5A-31-A0A-XX-X-XXX-XXX 5A-31-B0A-XX-X-XXX-XXX 5A-31-A0B-XX-X-XXX-XXX 5A-31-B0B-XX-X-XXX-XXX Single Operator 10 NC Valve 1 5A-11-A0A-XX-X-XXX-XXX 5A-11-B0A-XX-X-XXX-XXX 5A-11-A0B-XX-X-XXX-XXX 5A-11-B0B-XX-X-XXX-XXX DM-D XXX-XXX * Double Operator NO Valve NC Valve 10 1 10 1 5A-41-A0A-XX-X-XXX-XXX 5A-1-A0A-XX-X-XXX-XXX 5A-41-B0A-XX-X-XXX-XXX 5A-1-B0A-XX-X-XXX-XXX 5A-41-A0B-XX-X-XXX-XXX 5A-1-A0B-XX-X-XXX-XXX 5A-41-B0B-XX-X-XXX-XXX 5A-1-B0B-XX-X-XXX-XXX 33 34 36 3 37 38 5 67 69 44 46 4 47 48P XX Voltage X Wire length X Manual operator XX JA 110/50, 10/60 (.9W) A 18 (Flying leads) 1 Non-locking recessed KA JB 0/50, 40/60 (.9W) B 4 (Flying leads) Locking recessed KD JC 4/60 (.9W) J Connector JB FB 4 VDC (1.8W) JD DA 4 VDC (5.4W) DF 4 VDC (1.7W) BA SOLENOID OPERATOR GM-G XXX-XXX ** XX Voltage X Wire length X Manual operator XX DC 4 VDC (1.8W) A 18 1 Non-locking recessed BA DD 4 VDC (.5W) B 4 Locking recessed BT DF 4 VDC (4.0W) C 36 KA * Other options available, see page 309. KT ** Other options available, see page 313. OPTIONS 5A-31-A0A-XX-X-XXX-XXX For memory spring, replace by 4 (single solenoid only) Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 48 400 9 93 ISO 01 ISO 0 ISO 1 ISO ISO 3 65 Consult Precautions page 37 before use, installation or service of MAC Valves..

100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 5 TECHNICAL DATA Fluid : Pressure range : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal Pilot : 0 to 10 PSI External Pilot : Vacuum to 10 PSI Not required, if used select a medium aniline point lubricant (between 180 F and 10 F) 40 µ 0 F to 10 F (-18 C to +50 C) 1/8" : (1. C v ) 1/4" : (1.5 C v ) Class A continuous duty, # AWG x 18 lead wires -15% to +10% of nominal voltage Consult factory ~Inrush: 10.9 VA Holding: 7.7 VA = 1.8 to 1.7 W 4V=/5.4W Energize: 7.3 ms De-energize: 5.3 ms 10/60 Energize: 8-1 ms De-energize: 7-11 ms Options : BSPP threads DIMENSIONS Dimensions shown are metric (mm) #10-3 OR M5 (OPTIONAL EXTERNAL PILOT PORT) 4,5 1,0 3,5 DIA. THR U, TYP. () 79,0 4,0 44,0 17,0 7,0 13,0 5,0 TYP. () 1,6 15,5 6,5 4,5 66 Consult Precautions page 37 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE -DM- D XX X-X XX 1 3 4 - Pilot operated valves 5, 67, 9, 93, 400, ISO1, ISO, ISO3 Series OPTIONS AVAILABLE FOR 309 Consult Precautions page 37 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE D-XX X-X XX VOLTAGE DA 4 VDC (5.4W) DB 1 VDC (5.4W) DC 1 VDC (7.5W) DD 4 VDC (7.3W) DE 1 VDC (1.7W) DF 4 VDC (1.7W) DK 110 VDC (4.7W) DJ 8 VDC (5.W) DL 64 VDC (6.0W) DM 36 VDC (5.3W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 110 VDC (7.3W) DT 75 VDC (5.6W) DP 48 VDC (5.8W) FA 1 VDC (1.8W) FB 4 VDC (1.8W) FE 1 VDC (.4W) FF 4 VDC (.4W) JA 10/60, 110/50 (.9W) JB 40/60, 0/50 (.9W) JC 4/60, 4/50 (3.7W) JD 100/60, 100/50, 110/60 (3.9W) JE 0/60 (3.4W) JF 40/50 (.8W) JG 00/60, 00/50 (3.9W). WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires A 18" B 4" C 36" D 48" E 7" F 96" 4. ELECTRICAL CONNECTION D-XX X-X XX ELECTRICAL CONNECTION BA* Flying leads (grommet) BK* BA with protection diode BL* BA with protection varistor BM** Flying leads (solenoid plug-in) BN** BM with protection diode BP** BM with protection varistor BG** BM with ground BH** BM with protection diode & ground BJ** BM with protection varistor & ground CA* 1/" NPS conduit with flying leads CM* 1/" NPS metal conduit with flying leads CN* 1/" NPS metal conduit with flying leads & ground JB Rectangular connector JD JB with light JM Rectangular connector (male only) KA Mini square connector KB KA with protection diode KC KA with protection varistor KD KA with light KE KA with light and protection diode KF KA with light and protection varistor KG KA with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) TA Dual tabs with receptacles TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose A through F ** From Lead wire length options choose 0 through F Note: When coil is above 30 volts, a ground wire is required. Applies to options with flying leads. 3. MANUAL OPERATOR D-XX X-X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed Locking recessed 3 Non-locking extended 4 Locking extended 310 Consult Precautions page 37 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE -GM- G XX X-X XX 1 3 4 OPTIONS AVAILABLE FOR - Solenoid valves 5 & 400 Series 313 Consult Precautions page 37 before use, installation or service of MAC Valves..

OPTIONS 1. VOLTAGE 4. ELECTRICAL CONNECTION G-XX X-X XX VOLTAGE DC 4 VDC (1.8 W) DD 4 VDC (.5 W) DE 4 VDC (3.0 W) DF 4 VDC (4.0 W) DJ 1 VDC (1.8 W) DK 1 VDC (.5 W) DM 1 VDC (3.0 W) DN 1 VDC (4.0 W) G-XX X-X XX. WIRE LENGTH WIRE LENGTH 0 No lead wire (use only with "KJ" & "KM" elecrical connectors) A 18" B 4" C 36" D 48" E 7" F 96" G 10" H 144" 3. MANUAL OPERATOR G-XX X-X XX BA BB BC BD BE BF BG BH *BN *BP *BR *BS BT BU BV BW *BX *BY ELECTRICAL CONNECTION Flying leads BA with ground wire BA with light parallel to leads BA with light parallel to leads & ground wire BA with suppression diode BA with suppression diode & ground wire BA with suppression diode plus light parallel to leads BA with suppression diode plus light parallel to leads & ground wire BA with suppression diode plus blocking diode BA with suppression diode plus blocking diode & ground wire BA with suppression diode plus blocking diode & light parallel to leads BA with suppression diode plus blocking diode & light parallel to leads & ground wire BA with light on top BA with light on top & ground wire BA with suppression diode plus light on top BA with suppression diode plus light on top & ground wire BA with suppression diode plus blocking diode & light on top BA with suppression diode plus blocking diode & light on top & ground wire G-XX X-X XX MANUAL OPERATOR 1 Non-locking recessed Locking recessed 3 Non-locking extended 4 Locking extended G-XX X-X XX GA GB GC GD GE GF GG GH KA KB KE KF KJ KM *KN *KP KT KU KV KW *KX *KY SOLENOID PLUG-IN CONNECTOR WITH LEADS MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assembly KA with ground wire KA with suppression diode KA with suppression diode & ground wire Plug-in housing without wire assembly ('KA' without wire assembly) Plug-in housing without wire assembly ('KB' without wire assembly) KA with suppression diode plus blocking diode KA with suppression diode plus blocking diode & ground wire KA with light on top KA with light on top & ground wire KA with suppression diode plus light on top Note: Blocking diode is located in the lead wire KA with suppression diode plus light & ground wire KA with suppression diode plus blocking diode & light on top KA with suppression diode plus blocking diode & light on top & ground wire 314 Consult Precautions page 37 before use, installation or service of MAC Valves..