Losses in Power Electronic Converters

Similar documents
New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters

Module 7. Electrical Machine Drives. Version 2 EE IIT, Kharagpur 1

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

IMPORTANCE OF VSC IN HVDC

Space Vector PWM and Model Predictive Control for Voltage Source Inverter Control

Active Rectifier in Microgrid

COMPARISON STUDY OF THREE PHASE CASCADED H-BRIDGE MULTI LEVEL INVERTER BY USING DTC INDUCTION MOTOR DRIVES

UNIT-III STATOR SIDE CONTROLLED INDUCTION MOTOR DRIVE

Analysis of Hybrid Renewable Energy System using NPC Inverter

Analysis of Hybrid Renewable Energy System using NPC Inverter

Investigation of negative sequence injection capability in H-bridge Multilevel STATCOM

A Comparative Study between DPC and DPC-SVM Controllers Using dspace (DS1104)

ELEC387 Power electronics

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

Investigation of Magnetic Field and Radial Force Harmonics in a Hydrogenerator Connected to a Three-Level NPC Converter

CONTROL SCHEME OF STAND-ALONE WIND POWER SUPPLY SYSTEM WITH BATTERY ENERGY STORAGE SYSTEM

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

Hybrid PWM switching scheme for a three level neutral point clamped inverter

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

A Novel Voltage and Frequency Control Scheme for a Wind Turbine Driven Isolated Asynchronous Generator

High Voltage DC Transmission 2

SYNCHRONOUS MACHINES

Conventional Single-Switch Forward Converter Design

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

CHAPTER 6 BRIDGELESS PFC CUK CONVERTER FED PMBLDC MOTOR

Direct AC/AC power converter for wind power application

Reduction of flicker effect in wind power plants with doubly fed machines

CHAPTER 3 DC-DC CONVERTER TOPOLOGIES

Harmonics Reduction in a Wind Energy Conversion System with a Permanent Magnet Synchronous Generator

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Self-Excitation and Voltage Control of an Induction Generator in an Independent Wind Energy Conversion System

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

Development of a Single-Phase PWM AC Controller

ISSN Vol.03,Issue.07, August-2015, Pages:

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Investigation of D-Statcom Operation in Electric Distribution System

Harmonic Reduction of Arc Furnaces Using D-Statcom

PSPWM Control Strategy and SRF Method of Cascaded H-Bridge MLI based DSTATCOM for Enhancement of Power Quality

LOW VOLTAGE RIDE - THROUGH CAPABILITY OF WIND FARMS

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

Chapter 2 Shunt Active Power Filter

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Pak. J. Biotechnol. Vol. 13 (special issue on Innovations in information Embedded and communication Systems) Pp (2016)

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques

Harmonic Reduction in Induction Motor: Multilevel Inverter

Power Electronics Converters for Variable Speed Pump Storage

Laboratory Investigation of Variable Speed Control of Synchronous Generator With a Boost Converter for Wind Turbine Applications

WILEY CONTROL OF POWER INVERTERS IN RENEWABLE ENERGY AND SMART GRID INTEGRATION. Qing-Chang Zhong. Tomas Hornik IEEE PRESS

Modeling and Simulation of Five Phase Induction Motor Fed with Five Phase Inverter Topologies

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

Control Of Shunt Active Filter Based On Instantaneous Power Theory

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Improving Passive Filter Compensation Performance With Active Techniques

Speed Control of Induction Motor using Multilevel Inverter

Harnessing of wind power in the present era system

International Journal of Advancements in Research & Technology, Volume 7, Issue 4, April-2018 ISSN

Design and Simulation of Passive Filter

Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

POWER- SWITCHING CONVERTERS Medium and High Power

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 8 Issue 1 APRIL 2014.

Generalized Multilevel Current-Source PWM Inverter with No-Isolated Switching Devices

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

Model Predictive Control of Matrixconverter Fed Induction Generator for Wind Turbine

Exercise 3. Doubly-Fed Induction Generators EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Doubly-fed induction generator operation

DOWNLOAD PDF POWER ELECTRONICS DEVICES DRIVERS AND APPLICATIONS

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

CASCADED H-BRIDGE MULTILEVEL INVERTER FOR INDUCTION MOTOR DRIVES

Voltage Regulated Five Level Inverter Fed Wind Energy Conversion System using PMSG

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

International Journal of Advance Engineering and Research Development

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Design and implementation of Open & Close Loop Speed control of Three Phase Induction Motor Using PI Controller

Resonant Controller to Minimize THD for PWM Inverter

Dr.Arkan A.Hussein Power Electronics Fourth Class. 3-Phase Voltage Source Inverter With Square Wave Output

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

Voltage Balancing Control of Improved ZVS FBTL Converter for WECS

A Novel Cascaded Multilevel Inverter Using A Single DC Source

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

CHAPTER 2 VSI FED INDUCTION MOTOR DRIVE

Compensation of Distribution Feeder Loading With Power Factor Correction by Using D-STATCOM

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Generation of Voltage Reference Signal in Closed-Loop Control of STATCOM

Literature Review. Chapter 2

Unipolar and Bipolar PWM Inverter

Module 5. DC to AC Converters. Version 2 EE IIT, Kharagpur 1

Conventional Paper-II-2013

Transcription:

Losses in Power Electronic Converters Stephan Meier Division of Electrical Machines and Power Electronics EME Department of Electrical Engineering ETS Royal Institute of Technology KTH Teknikringen 33 SE- 44 Stockholm Abstract This work is the proposed solution for Task, Problem, in the Nordic PhD course on Wind Power, held in Smøla, Norway, between June 5-, 5. It discusses the converter losses and the expected costs of the back-to-back converter in a doubly-fed induction generator (DFIG) in a wind turbine application. Two different topologies of back-to-back converters are considered: A conventional two-level converter and a three-level diode-clamped converter. I. INTRODUCTION During the past few years, variable-speed wind turbines have become the dominant type among newly-installed units. Variable-speed wind turbines are designed to achieve maximum aerodynamic efficiency over a wide range of wind speeds by continuously adapting the rotational speed of the wind turbine to the wind speed. The advantages of variable-speed wind turbines are an increased energy capture, improved power quality and reduced mechanical stress on the structure. In order to achieve variable-speed operation of the wind turbine, the electric system is getting more complicated. In recent years, mainly back-to-back converters are being used in the power conversion field for wind turbines. One solution is to use a fullscale back-to-back converter that allows full variable-speed operation of the wind turbine at the cost of a large, expensive and lossy frequency converter that is rated at nominal generator power. This configuration is used by e.g. Enercon. Another solution is to equip the variable-speed wind turbine with a DFIG. In the DFIG wind turbine configuration, the stator of the wound-rotor induction generator is directly connected to the collection grid whereas the rotor windings are connected to a back-to-back converter over slip rings. However, this solution does only provide a limited speed range, depending on the rating of the frequency converter. A manufacturer using this configuration is e.g. Vestas. The advantage of applying back-to-back converters in the power conversion field for wind turbines is that these converters are completely programmable and due to it, they are very versatile. This allows different control strategies to control the active power flow and to both provide reactive power to the induction generator and to achieve the compensation of reactive power on the line side. According to [], the DFIG system has the advantage that the back-to-back converter needs only to be dimensioned with a fraction of the rated turbine power depending on the required speed range. Both the costs and the conduction and switching losses of the semiconductor valves are approximately proportional to the converter rating and are thus decreasing with the same proportion. Also the converter filters and the filters for electromagnetic interference (EMI) can be relaxed as they only have to be rated proportional to the converter rating, which signifies an additional large cost reduction. The disadvantage of applying back-to-back converters is that these electronic devices are relatively expensive and that they introduce additional losses in the system due to the conduction and switching losses of the semiconductor valves. Recently, a new and promising technology was introduced, the multilevel converters. These type of converters promise improvements in the harmonic quality of the output voltage which is an advantage because the output filters of the system can be relaxed. But at first sight, these converters seem to increase the cost and the losses of the converters, as the number of components increases compared to the conventional two-level converters. Therefore, this work presents a study of the losses and the expected costs of two different back-to-back converter topologies; a conventional two-level converter and a threelevel diode-clamped converter. At first, the problem is defined properly and it is determined what power flows that can be expected in both the rotor-side and the line-side voltage source converter (VSC). Then, the two considered topologies are presented and the harmonic spectrum in the respective output voltages are analyzed. Finally, a comprehensive simulation of the losses in the back-to-back converter is presented. A basic cost comparison and a summary of the main findings concludes this work. II. PROBLEM DEFINITION The active and reactive power flows have to be determined in order to know the operation status of the back-to-back converter. Therefore, it is essential to have a generator model and a basic control system for the two VSCs. The parameters of the wound-rotor induction generator are given in p.u.-values and it is very convenient to normalize the voltage-current equations of the DFIG. In this section, it is also described how the base values for the simulation were chosen and how the

variables have to be scaled during a transformation between P r different reference frames. PSfrag replacements Q s P r Q r A. Generator model In order to determine the power flows, currents and voltages for different operating conditions, i.e. for different rotor speeds, it is necessary to develop a generator model. The wound-rotor induction generator used in the DFIG system comprises a three-phase stator winding and a three-phase rotor winding, which is fed via slip rings. The used generator model is chosen according to [], neglecting the stator and rotor transients which are not important in this context. The equations that describe the voltage-current relationship of a doubly-fed induction generator are given in p.u.-values as: u ds = R s i ds + ω s ((L sσ + L m ) i qs + L m i qr ) u qs = R s i qs ω s ((L sσ + L m ) i ds + L m i dr ) u dr = R r i dr + sω s ((L rσ + L m ) i qr + L m i qs ) u qr = R r i qr sω s ((L rσ + L m ) i dr + L m i ds ) () In these equations, a synchronous two-phase dq-reference frame is used, that is fixed to the space vector of the stator voltage. This is a convenient alternative because the DFIG operates as a generator being fed with constant stator voltage (in the dq-reference frame). Hence, the stator voltage and current are given for line operation of the DFIG system. The equations for determining active and reactive power flows, which are defined according to Figure, are given as: P s = u ds i ds + u qs i qs P r = u dr i dr + u qr i qr Q s = u qs i ds u ds i qs Q r = u qr i dr u dr i qr () The absolute values of the stator and rotor voltages, respective currents, can be calculated as: u s = u ds + u qs u r = u dr + u qr i s = i qs + i ds i r = i qr + i dr (3) The power factors cos φ on the rotor and stator side are defined as: cos φ s = P s S s = P s P s + Q s cos φ r = P r P r = S r P r + Q r = P s u s i s = P r u r i r (4) P = P s + P r, Q = Fig.. P s, Q s Active and reactive power flows in the DFIG system. TABLE I PARAMETERS OF THE WOUND-ROTOR INDUCTION GENERATOR. Parameter Value [p.u.] Magnetising inductance L m 4. Stator leakage inductance L sσ. Rotor leakage inductance L rσ. Stator resistance R s.5 Rotor resistance R r.5 Stator connection Delta Rotor connection Star B. Simulation parameters and their normalization For this work, it is assumed that the rated power S N of the wind turbine is MVA. The collection grid voltage U N at the connection point is 69 V, which is a common choice for wind turbines. The normalized p.u.-values of the woundrotor induction generator can be found in Table I. It is very convenient to work with normalized values as the control system and the design process get independent of the actual generator size. The peak phase voltage and peak phase current are chosen as the base values, base on which the other base values of the model can be calculated as shown in Table II. It has to be considered that all quantities are given in the rotating dq-reference frame, and that the stator windings are delta connected while the rotor windings are star connected. The transformation from the stationary three-phase abc-reference frame to the rotating two-phase dq-reference frame via the stationary two-phase αβ-reference frame is given as (valid for both currents and voltages): u α = ( u a 3 u b ) u c ( u β = ) 3 3 3 u b u c (5) u d = u α cos θ u β sin θ u q = u β cos θ + u α sin θ (6) where θ is the angular position of the rotating dq-reference frame relative to the stationary αβ-reference frame. However, the dq-quantities have to be scaled in order to get the same amplitudes as the phase quantities according to Table III [3].

TABLE II MODEL BASE VALUES. Parameter Equation Value Base voltage U base = U N 563.4 V 3 PSfrag replacements Base power S base = S N = 3 U basei base MVA Base current I base = S base 3U base = U base I base.8 ka Base impedance Z base.48 Ω Base angular frequency ω base = πf N 34 rad/s TABLE III SCALING FACTORS FOR REFERENCE FRAME TRANSFORMATIONS. Active, reactive power [p.u.].8.6.4.. P s Q r P Q s P r.3.....3 Slip Fig.. Active and reactive power of the rotor and stator as a function of the slip. Parameter Scaling factor Stator voltages u ds, u qs, u s 3 3 =.385 Rotor voltages u dr, u qr, u r =.667 3 3 Stator currents i ds, i qs, i s =.55 3 Rotor currents i dr, i qr, i r 3 =.667 Stator power P s, Q s, S s 3 =.667 Rotor power P r, Q r, S r 3 =.667 C. DFIG vector control In order to get the operation conditions for different operation points, i.e. for different rotor speeds, a basic vector control scheme was implemented. Its main purpose is to guarantee stable operation and enable the independent control of active and reactive power of the back-to-back converter. The controller is using the generator model equations derived in the previous section in the rotating dq-reference frame. The desired rotor voltage command is determined in order to control the active and reactive rotor power by controlling the rotor currents. The line-side converter is controlling the DClink voltage and the reactive power of the total DFIG system, which is assumed to have unity power factor, i.e. it is neither absorbing nor generating reactive power (Q = ). In this study, it is assumed that the mechanical rotor speed is required to have the possibility to change from.7 to.3 times the synchronous generator speed, which corresponds to a slip range between -.3 to +.3. The slip s of the induction generator is given as s = ω s ω mech ω s = ω r ω s, (7) where ω s is the electrical angular frequency of the stator quantities (which is constant and equal to the base angular frequency ω base ), ω mech is the mechanical angular frequency of the rotor shaft and ω r is the electrical angular frequency of the rotor quantities. This equation is valid for an induction generator with two poles (one pole pair). The number of electrical poles in the induction generator does not influence its electrical behavior but changes the requirement on the gear ratio in the gear box of the wind turbine. It can be noticed that the electrical angular rotor frequency at zero slip becomes zero, which means that a pure DC current will flow in the rotor. Figure shows the active and reactive rotor and stator power over the required speed range. It can be noticed that the active rotor power P r is flowing through the back-to-back converter, as it cannot generate, consume or store active power (apart from the losses that inherently appear). The total active power generated by the doubly-fed induction generator is the sum of the rotor and stator active power P = P s + P r. With the chosen DFIG control scheme, the active stator power is kept constant over the whole speed range while the rotor power is proportional to the slip. In contrary to the active power, the back-to-back converter can generate or consume reactive power, which is utilized in order to get unity power factor at the connection point of the wind turbine. It can be seen that the back-to-back converter operates as a generator of active power above synchronous speed and delivers active power to the grid. At a slip of s =.3, the wind turbine delivers rated active power to the collection grid. Contrary, below synchronous speed, the back-to-back converter by-passes active power from the grid into the rotor circuit and the active power delivered to the grid becomes approximatively half the rated power at a slip of s =.3. Figure 3 shows the rotor and stator voltages and currents over the required speed range. It can be seen that the stator voltage is as expected p.u. Also the stator and rotor currents are constant over the whole speed range, while the rotor voltage is approximately proportional to the absolute value of the slip and becomes zero for zero slip. III. CONSIDERED TOPOLOGIES The considered topologies for the back-to-back converter are a conventional two-level converter as shown in Figure 4 and a three-level diode-clamped converter as shown in Figure 6. The two-level topology is widely used in VSC transmission systems and in back-to-back converters in DFIG wind turbines at a wide range of power levels. Figure 5 shows the output waveform of the two-level converter which is either positive or negative. p.u. voltage corresponds to half the DC-link voltage. In order to improve the quality of the voltage output, a pulse width modulation (PWM) switching 3

.9 u s.8 placements Voltage, current [p.u.].7.6.5.4.3 i s i r.. u r.3.....3 Slip Fig. 4. Conventional two-level converter. Fig. 3. Voltage and current of the rotor and stator as a function of the slip. scheme is used that produces a waveform with a dominant fundamental component with the compromise that significant higher-order harmonics are also generated, as shown in the harmonic spectrum of the two-level converter in Figure 5. The applied PWM switching scheme is a carrier-based control method with a switching frequency of 5 Hz (frequency modulation ratio p = ). The amplitude modulation ratio in Figure 5 is m a =.94, which corresponds to the operation point of the line-side VSC in the back-to-back converter. By splitting up the DC capacitor and the insulated gate bipolar transistor (IGBT) valves and with the help of additional diodes, a three-level diode-clamped converter as shown in Figure 6 can be formed. The output waveform comprises three voltage levels, i.e. p.u.,, - p.u. as shown in Figure 7. p.u. voltage corresponds to half the DC-link voltage that is the voltage above one of the bus-splitting capacitors. As for the two-level converter, a carrier-based PWM switching scheme with an identical frequency and amplitude modulation ratio is appplied in order to be able to compare the results with the two-level converter topology. Figure 7 shows the harmonic content in the waveform, which has a considerably lower total harmonic distortion (THD). It should be noticed that the effective switching frequency of the IGBT valves is only half the one in the two-level converter topology. This is due to the splitting of the valves and the characteristics of the control method. The advantages and disadvantages of the two-, respectively three-level converter topologies can be summerized according to Table VI. The conduction and switching losses as well as the converter costs and the capacitor size are further investigated in this work. A. Choice of components Table V shows the characteristics of the back-to-back converters and the choice of the IGBT semiconductor components from Semikron [4] and the DC link capacitors from Evox Riva [5]. Please refer to the corresponding datasheets for further information about the chosen components. Voltage [p.u.] Amplitude [p.u.].5.5 Fig. 5..8.6.4. 4 6 8 4 6 8 Time [ms] 3 4 5 6 7 8 9 Harmonic number Output waveform and harmonic spectrum of the two-level converter. Fig. 6. Three-level diode-clamped converter. TABLE IV COMPARISON BETWEEN TWO- AND THREE-LEVEL CONVERTERS. Characteristic Two-level Three-level Circuitry Very simple More complex Control Very simple More problematic Capacitor size Small Large IGBT duty Equal Different IGBT blocking voltage Large Small (half) Harmonic content Large Small Switching losses High Relatively low Footprint (size) Small Somewhat larger 4

Voltage [p.u.] Amplitude [p.u.].5.5 4 6 8 4 6 8 Time [ms].8.6.4. 3 4 5 6 7 8 9 Harmonic number Fig. 7. Output waveform and harmonic spectrum of the three-level diodeclamped converter. DC link voltage Semiconductor components [4] TABLE V CHOICE OF COMPONENTS. IGBT module (-level rotor-side): IGBT module (-level line-side): IGBT module (3-level rotor-side): IGBT module (3-level line-side): Clamping diode module (3-level): DC link capacitors [5] -level (3 series-capacitors à 4 V): 3-level (6 series-capacitors à V): IV. LOSSES V SKM 5GA3D SKM 4GA3D SKM 4GB66D SKM 3GB66D SKKD 5F PEHVV447AM 4.7 mf PEH69RV5VM mf The losses are calculated in Matlab under the assumption that the three-phase currents on the rotor- and line- side are perfectly sinusoidal, which can be assumed as the current ripple in average will not generate any additional losses. The total losses consist of conduction and switching losses in the IGBT and clamping diode modules. The conduction losses P cond depend on the on-state voltage drop across the device and the current through it. They can be calculated from the on-state threshold voltage V ce, the onstate slope resistance r ce, and the device current I ce according to f ( P cond = f Vce I ce (t) + r ce Ice (t)) dt (8) t= Both the on-state slope resistance and the threshold voltage depend on the device temperature and were chosen according to the typical values given in the datasheets. The switching losses consist of turn-on and turn-off losses of the IGBTs, the anti-parallel diodes and the clamping diodes in the three-phase converter topology. The switching losses can be calculated from the characteristic turn-on and turn-off energy (E on, respectively E off ) given in the datasheets. Unfortunately, the switching losses for the antiparallel diodes are not mentioned and could therefore not be included in this study. Also the losses from the reverse recovery energy E rr have to be considered. A reverse recovery current is required in order to sweep out the excess carriers in the anti-parallel diode and allow it to block a negative polarity voltage. The switching losses are also dependent on the switched current and the device temperature. The switching losses P sw can be calculated by summing up the switching events during a fundamental period according to ( P sw = f Eon (I ce ) + E off (I ce ) + ) E rr (I ce ) (9) A. Results of the loss comparison The results of the loss comparison between the two- and three-level converter topologies is shown in Table VI. Different operation points corresponding to slip levels between -.3 and.3 are investigated. The total losses are divided in switching losses, IGBT conduction losses and diode conduction losses and presented both for the rotor- and line-side converter. The conclusions from Table VI can be summerized as follows: The total losses of the three-level converter are approximately % bigger for all points of operation. This is mainly due to the dominating conduction losses, which are increasing by approximately 3 % compared to the conventional two-level converter. The conduction losses are contributing with over 9 % to the total losses. The switching losses of the three-level converter are approximately 6 % smaller for all points of operation. This is a huge improvement but does not influence the total losses due to their relatively low significance at the chosen switching frequency of 5 Hz. However, for increasing switching frequencies, the switching losses are getting more important. Another advantage of the threelevel converter is that the low harmonic content allows to decrease the switching frequency considerably compared to the two-level converter, which will further decrease the switching losses. It is also interesting to see how the distribution of the conduction losses between the IGBT and their antiparallel diodes changes depending on the operation point and the line- or rotor-side converter. It is also noticeable that the total losses are the smallest when the DFIG system is operating near the synchronous speed. The total losses are slightly increasing with an increasing slip. V. COST COMPARISON A cost comparison ist not simple and would require further design consideration in order to get accurate results. However, it is possible to estimate the thendency by watching at the rating of the semiconductor devices and the size of the DClink capacitors. 5

TABLE VI LOSS COMPARISON BETWEEN TWO- AND THREE-LEVEL CONVERTER TOPOLOGIES FOR DIFFERENT OPERATION POINTS. Slip s.3.. -. -. -.3 Shaft speed ω mech.7 ω s.8 ω s.9 ω s ω s. ω s. ω s.3 ω s Electrical phase quantities of the rotor-side converter Voltage u r [ ˆV] 94. 96. 97.5. 99. 97. 95.8 Current i r [Â] 475.5 475.5 475.5 475.5 475.5 475.5 475.5 cos φ r -.7 -.7 -.7 N.A..76.73.7 Electrical phase quantities of the line-side converter Voltage u s [ ˆV] 563.4 563.4 563.4 563.4 563.4 563.4 563.4 Current i s [Â] 374. 349.3 33.8 38. 333.9 349.3 374. cos φ s -.48 -.34 -.8..8.34.48 Losses in the rotor-side converter Topology level 3level level 3level level 3level level 3level level 3level level 3level level 3level Switching losses [W] 35 35 35 3 3 98 35 5 35 5 35 5 IGBT conduction [W] 49 66 33 538 5 43 3 39 99 6 888 4 784 9 Diode conduction [W] 57 885 648 75 84 75 879 36 953 475 8 589 Total [W] 95 648 66 64 35 637 74 7 75 673 46 666 7 66 Losses in the line-side converter Topology level 3level level 3level level 3level level 3level level 3level level 3level level 3level Switching losses [W] 5 9 34 9 6 96 6 93 34 94 49 95 IGBT conduction [W] 56 65 593 694 646 756 733 858 855 998 9 73 8 397 Diode conduction [W] 944 35 79 38 67 965 578 833 5 737 467 67 439 69 Total [W] 753 3 69 94 54 83 53 788 593 88 7 939 897 Total losses in the DFIG back-to-back converter Switching losses [W] 555 539 53 5 54 94 53 44 539 44 554 45 Difference [%] -6-6 -6-64 -54-55 -56 Conduction losses [W] 3493 455 3346 437 345 455 365 496 337 457 337 436 346 4536 Difference [%] +3 +3 +3 +3 +3 +3 +3 Total losses [W] 448 477 3885 4583 3776 446 386 449 3768 45 3856 465 44 478 Difference [%] +8 +8 +8 +8 +9 +9 +9 The rating of the semiconductor devices is comparable for the two different converter topologies. The three-level converter, however, has an additional clamping diode module for each VSC. The costs for the gate drive and control system are also increasing somewhat for the three-level converter, as the number of IGBTs is twice the one in the two-level converter and the control of mainly the DC capacitor voltage is more complex as it is shown below. The DC capacitor volume will also affect the costs for the two converter topologies. It has to be calculated in order to limit the voltage ripple to a comparable level. An acceptable voltage ripple is 5 %. The size of the capacitance is then determined by the capacitor current, which is shown in Figure 8 for the twoand three-level converters. It can be seen that the short-time average current in the two-level converter is approximately zero, unlike for the three-level converter, where it is varying considerably. This is due to the different duty ratios of the semiconductor devices. As expected, this fact has a strong influence on the voltage ripple, as shown in Figure 9. While the voltage ripple can easily be limited to below 5 % for the twolevel converter, it is not possible for the three-level converter. Even the largest available capacitor with mf does not limit the voltage ripple to below 4 %. It can be noticed that the DC-link voltage has to be actively controlled by the line-side VSC in order to keep it in a reasonable range. A comparison for the chosen configuration shows that the capacitor size is twice as large for the three-level compared to the twolevel converter topology. Both implemented capacitors have the same dimensions (75 mm diameter, 45 mm length), but the number of required components differs with a factor two. In order to do an appropriate cost comparison, it would also be essential not only to consider the initial costs but also the costs due to increased or decreased system losses. However, this is out of the scope of this work. VI. CONCLUSIONS A conventional two-level and a three-level diode-clamped converter have been introduced for the application in the backto-back converter of a DFIG wind turbine. A comprehensive loss evaluation showed that the system losses are lower for the two-level converter for any point of operation. This is valid 6

level converter 4 Capacitor current [A] 4 6..4.6.8...4.6.8. 4 3 level diode clamped converter Capacitor current [A] 4 6..4.6.8...4.6.8. Fig. 8. Capacitor current for the - and 3-level converter topologies. 3 level converter DC capacitor voltage [V] 9 8 7 6..4.6.8...4.6.8. 75 3 level diode clamped converter DC capacitor voltage [V] 7 65 6 55 5 45...3.4.5.6.7 Fig. 9. Capacitor voltage for the - and 3-level converter topologies. for the investigated switching frequency of 5 Hz, where the conduction losses are dominating over the switching losses. It was also shown that the initial costs of the three-level converter are somewhat increased due to the larger DC-link capacitors required. The future will show if and in what applications the obvious advantages of multi-level converters can stand up to the simplicity and robustness of conventional two-level converters. REFERENCES [] S. Müller, M. Deicke, R. W. de Doncker, Doubly Fed Induction Generator Systems for Wind Turbines, IEEE Industry Applications Magazine, May/June. [] Wind Power in Power Systems, Editor T. Ackermann, John Wiley & Sons, Ltd. 5. [3] R. Pena, J. C. Clare, G. M. Asher, Doubly Fed Induction Generator using Back-to-back PWM Converters and its Application to Variable- Speed Wind-Energy Generation, IEE Proc.-Electr. Power Appl., Vol. 43, No. 3, May 996. [4] Semikron, http://www.semikron.com. [5] Evox Riva, http://www.evox-rifa.com/europe/index.html 7