The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. dundancy System Monitor and Control.

Similar documents
The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. Removable fan trays System is 100% field maintainable

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

High Power Outdoor. GaAs Solid State Power Amplifiers

High Power Outdoor. GaN Solid State Power Amplifiers

300W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

40W Ka-Band Compact Outdoor SSPA with AC Input Option B

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

125W Ku-Band Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

800W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

High Power Outdoor. GaN Solid State Power Amplifiers

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

Indoor Rack Mount. GaN Solid State Power Amplifiers 3RU Rack Height

Phase Combined Systems

328 Innovation Blvd. 2&3 The Matchyns, London Road, Rivenhall End

328 Innovation Blvd. 1 Wheaton Road, Witham

Mini Compact Outdoor GaN SSPAs in C-, X-, and Ku-Bands

4RU Rack Mountable. Solid State Power Amplifiers

Compact Outdoor Solid State Power Amplifiers in S-, C-, X-, and Ku-Bands

328 Innovation Blvd. 1 Wheaton Road, Witham

Ku-Band VSAT Block Up Converters

PowerMAX Redundant SSPA Systems. Soft-fail Redundancy Modular, Hot-swap Assemblies Indoor and Outdoor Packages

C-Band VSAT Block Up Converters

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

C-Band Redundant LNA Systems

X-Band Redundant LNA Systems

Redundant LNA Systems

INTRODUCTION STANDARD FEATURES. Option: High ambient temperature operation (up to 60 C) APPLICATION KU-BAND BOOSTER AMPLIFIER

KU-BAND OUTDOOR BLOCK CONVERTERS

Block Upconverters for Integration in High Power Amplifiers

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

VSAT Redundant System Solutions

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

PCN-1800 Series. VHF TV Transmitter. 2nd Edition

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Amplifier HF MHz

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

PARADISE DATACOM APPLICATION NOTE. Satellite Terminal System Planning using L Band Modems. AN_032 Issue 2

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

XR kw AM Medium Wave Broadcast Transmitter

Digital Microwave Radios

Figure 1: Overlapping of carriers into common spectral footprint. 328 Innovation Blvd. 1 Wheaton Road, Witham

End of Life. Optical Node Series (HL2) HLN3142C. HL2 Series PWRBlazer II Optical Nodes FEATURES PRODUCT OVERVIEW. arris.com

J kw AM Transmitter

High Power Amplifier, Solid State, Broadband MHz, 51dB Gain, SMA Female Connectors, 1dB GCP. RAMP M-51d-Sf-80W-e7

Mission Critical DAS Solution

2 GHz to 6 GHz, 500 W Power Amplifier HMC8113

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Solid State General Communication Power Amplifier

OX-204 at 10 MHz Ultra Low Phase Noise Oven Controlled Crystal Oscillator

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

Optical Delay Line Application Note

ModuMAX High Power Amplifier Advancements

1 KW TOTALLY SOLID STATE DIFFERENTIAL GPS TRANSMITTER ( khz)

SPA SMA DATA SHEET

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

Advanced Test Equipment Rentals ATEC (2832)

COMMUNICATION SATCOM / DATA LINK CAPABILITIES. Microwave solutions for your demanding requirements

Your Single Source for Advanced Microwave and RF Technologies. teledynemicrowave.com or

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

SFT DAB. DAB Transmitters up to 15 kw rms.

Technical Datasheet GT-1000B Microwave Power Amplifier. 100 MHz to 20 GHz. Broadband High-Power Instrumentation Amplifier Rev.

Outdoor Terrestrial Transmitter / Repeater

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

INSTRUCTION SHEET WIDEBAND POWER SENSOR MODEL Copyright 2008 by Bird Electronic Corporation Instruction Book P/N Rev.

FREEDOM Communications System Analyzer R8100 DATA SHEET

Opti Max Optical Node Series

Alcatel-Lucent MDR G H z F E D E R A L D I G I T A L R A D I O S

NA100 NA200 NA300. NA Series Frequency Agile Medium Wave Broadcast Transmitters

Product Guide. VIDA Oscillator Series. High Performance YIG Oscillator Westwind Blvd., Santa Rosa, CA Phone , FAX

SATELLITE GROUND SEGMENT

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

FMAM5032 DATA SHEET. 48 db Gain High Power High Gain Amplifier at 50 Watt Psat Operating From 500 MHz to 3 GHz with 52 dbm IP3 and SMA.

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

25, 50 and 100 kw Digital Solid-State AM Transmitters

SPECIFICATION FREQUENCY RANGE: IBS-6

FREEDOM Communications System Analyzer R8100 DATA SHEET

Airmux-400 Specifications

(ES) Equipements Scientifiques SA - Département Réseaux sans fil rue de Buzenval BP Garches Tél Fax.

NI PXIe-5601 Specifications

CUSTOM INTEGRATED ASSEMBLIES

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

IQgig-RF TM Model B Technical Specifications

Solid State Broadband High Power Amplifier

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Alcatel-Lucent MDR / 1 1 G H z D I G I T A L R A D I O S

DC-20 GHz Distributed Driver Amplifier. Parameter Min Typ Max Min Typ Max Units

Transcription:

Outdoor MAX The New Standard in Outdoor High Redundant Microwave Amplifier Systems Has Arrived 2.5 kw Ku-Band System configured with (8) 400W s FEATURES Output levels of up to: 7.1 kw in C-Band; 5.9 kw in X-Band; 3.0 kw in Ku-Band Each array of 4 HPAs features no active switching - all passive Combining Output sized for N+1 Redundancy System can be configured with any combination of 4 to 16 units Removable fan trays Teledyne Paradise Datacom 328 Innovation Blvd., Suite 100 State College, PA 16803 USA Tel: (814) 238-3450 Fax: (814) 238-3829 PAGE 1 OF 10 System is 100% field maintain- Optional L-Band Input with Reable dundancy System Monitor and Control RF Gain Adjustment emulates single Chassis (42-62 ) Ku-Band sysoperation tems (50-70 ) all others Legacy RS-485 M&C Ethernet Port with UDP, SNMP, System is field scalable: i.e., can start out with (4) modules and internal web browser in system and upgrade to (8) or capability (16) modules. Accurate Output measurement Reflected Monitor MAX is covered by U.S. Patent Nos. RF Output Sample Port 8,189,338 B2 and 8,411,477 B2 www.paradisedata.com Teledyne Paradise Datacom Ltd. 2&3 The Matchyns, London Road, Rivenhall End Witham, Essex CM8 3HA United Kingdom Tel: +44(0) 1376 515636 Fax: +44(0) 1376 533764 214835 REV A ECO 18375

Outdoor MAX System Operation The Outdoor MAX system maintains complete parallel redundancy down to the embedded control level. Therefore the loss of an entire amplifier will not interrupt remote communications with the system. Remote communications can be either RS-485 or Ethernet. The system will automatically correct its gain level in the event of one or more amplifier failures. The sophisticated system monitor and control allows the system to be locally or remotely operated as if it were a single chassis amplifier. The system control maintains a hierarchical management that allows the operator to interface to a single chassis of the multi-module array. Another feature unique to Teledyne Paradise Datacom s Outdoor MAX is the introduction of true rms output power measurement. Unlike other amplifier systems that utilize diode detection schemes, the Outdoor MAX reports the true rms output power of the system independent of the number of carriers and modulation schemes. Proprietary waveguide combining techniques are employed so that maximum power combining efficiency is optimized within the operating frequency band. System Output and Configurations The Outdoor MAX system is typically used as a self-redundant system. The output power is sized such that the loss of (1) RF module s power will still allow the system to maintain its minimum required output power. This type of system architecture is described as n+1 redundant. The system can be configured with any number of modules, but best overall efficiency is obtained with the popular binary combinations of 4, 8, or 16 modules. It is very easy to upgrade the MAX system from 4 modules to 8 or 16 modules in the field. It is not necessary to fully populate the system at the time of initial purchase. This provides the user a path to upgrade output power capability as system requirements grow, thus keeping capital investment minimized. For sizing redundant output power capability use the following guideline to determine the output power of the system with the loss of (1) module. 4 System - 3 of 4 s Operable = 2.5 loss in output power capability 8 System - 7 of 8 s Operable = 1.2 loss in output power capability 16 System - 15 of 16 s Operable = 0.6 loss in output power capability PAGE 2 OF 10 214835 REV A ECO 18375

Outdoor MAX Hitless Redundancy For mission critical systems in which no power outage can be tolerated, an eight module Outdoor MAX system can be operated with only four modules installed. In this way, the additional four modules can be installed without requiring the system to be powered off. The only disadvantage of operating the eight module Outdoor MAX system with four modules is the additional 3 loss that the four module (halfsystem) system experiences by going through the final hybrid combiner as shown at right. The overall output power is therefore actually 6 below what it would be with all eight modules present. Chassis Chassis Chassis Chassis Shorting plate on each waveguide extension 1 2 3 4 1 Σ 4-Way Combiner Δ IN IN Σ Detector 2-Way Combiner RF OUT If the module output power is sized such that this reduction in output power can be tolerated, the system shown at right is an effective means of scaling the system from four to eight modules and maintaining true hitless operation. 2 3 4 Σ 4-Way Combiner With parallel system architectures, the amplifier output power capability and gain will change as the number of active modules vary. The Outdoor MAX system is designed with an Auto-Gain Control mode so that the overall system gain will remain constant in the event of a single module failure. See the table below. System Type # s in System Gain Change Auto Gain Control On Gain Change Auto Gain Control Off Maximum Output 4 Units 3 of 4 0-2.5-2.5 4 Units 2 of 4-1.0-6.0-6.0 4 Units 1 of 4-7.0-12.0-12.0 8 Units 7 of 8 0-1.2-1.2 8 Units 6 of 8 0-2.4-2.4 8 Units 5 of 8 0-4.0-4.0 8 Units 4 of 8-1.0-6.0-6.0 8 Units 3 of 8-3.5-8.5-8.5 8 Units 2 of 8-7.5-12.5-12.5 16 Units 15 of 16 0-0.6-0.6 16 Units 14 of 16 0-1.2-1.2 16 Units 13 of 16 0-2.0-2.0 16 Units 12 of 16 0-2.5-2.5 PAGE 3 OF 10 214835 REV A ECO 18375

Outdoor MAX Population Options The Outdoor MAX system is available in a variety of system GaAs module configurations and output power levels. The system is based on Teledyne Paradise Datacom s High Outdoor. The units can be configured with a wide variety of frequency bands and power levels, and can be fitted with the following modules: C-Band: 400W, 500W, 600W X-Band: 350W, 500W Ku Band: 200W, 250W Hot Swappable Air Exhaust Fan Trays (2x) Hot Swappable Air Intake Fan Tray Single Unit Mechanical & Environmental Specifications PARAMETER NOTES LIMITS UNITS Size width X length X height 16.5 X 27.5 X 9.335 419 X 699 X 238 Weight 100 (45.5) lbs. (kg) Finish powder coat white Operating Temperature Ambient -40 to +60 C Relative Humidity Condensing 100 % Cooling System Integrated Forced air Ingress Protection Rating With connectors properly sealed IP54 Altitude No temperature de-rating up to 10,000 ft. (3,000 m) De-rate maximum temperature by 2 C per 1,000 ft (300 m) beyond 10,000 ft. Shock 50 g p-p, 11 msec pulses Vibration 3g rms 30 min. 5-2000 Hz inches mm PAGE 4 OF 10 214835 REV A ECO 18375

Outdoor MAX 4 C-Band Outdoor MAX System Specifications 4 (W) 3 Redundant 400 W 61.2 (1318) 60.2 (1047) 9600 58.8 (759) 57.8 (603) 500 W 62.2 (1660) 61.2 (1318) 11200 59.8 (955) 58.8 (759) 600 W 63.0 (1995) 62.2 (1660) 14800 60.6 (1148) 59.8 (955) 4 X-Band Outdoor MAX System Specifications 4 (W) 3 Redundant 350 W 60.7 (1175) 59.7 (933) 10800 58.3 (676) 57.3 (537) 500 W 62.2 (1660) 61.2 (1318) 16000 59.8 (955) 58.8 (759) 4 Ku-Band Outdoor MAX System Specifications 4 (W) 3 Redundant 200 W 58.2 (661) 57.2 (525) 10000 55.8 (380) 54.8 (302) 250 W 59.2 (832) 58.2 (661) 11200 56.8 (479) 55.8 (380) PAGE 5 OF 10 214835 REV A ECO 18375

Outdoor MAX 8 C-Band Outdoor MAX System Specifications 8 (W) 7 Redundant 400 W 64.0 (2512) 63.0 (1995) 19200 62.8 (1905) 61.8 (1514) 500 W 65.0 (3162) 64.0 (2512) 22400 63.8 (2399) 62.8 (1905) 600 W 66.0 (3981) 65.0 (3162) 29600 65.0 (3162) 64.0 (2512) 8 X-Band Outdoor MAX System Specifications 8 (W) 7 Redundant 350 W 63.5 (2239) 62.5 (1778) 21600 62.3 (1698) 61.3 (1349) 500 W 65.0 (3162) 64.0 (2512) 32000 63.8 (2399) 62.8 (1905) 8 Ku-Band Outdoor MAX System Specifications 8 (W) 7 Redundant 200 W 61.0 (1259) 60.0 (1000) 20000 59.8 (955) 58.8 (759) 250 W 62.0 (1585) 61.0 (1259) 22400 60.8 (1202) 59.8 (955) PAGE 6 OF 10 214835 REV A ECO 18375

Outdoor MAX 16 C-Band Outdoor MAX System Specifications 16 (W) 15 Redundant 400 W 66.7 (4677) 65.7 (3715) 38400 66.1 (4074) 65.1 (3236) 500 W 67.7 (5888) 66.7 (4677) 44800 67.1 (5129) 66.1 (4074) 600 W 68.5 (7079) 67.7 (5888) 59200 67.9 (6166) 67.1 (5129) 16 X-Band Outdoor MAX System Specifications 16 (W) 15 Redundant 350 W 66.2 (4169) 65.2 (3311) 43200 65.6 (3631) 64.6 (2884) 500 W 67.7 (5888) 66.7 (4677) 64000 67.1 (5129) 66.1 (4074) 16 Ku-Band Outdoor MAX System Specifications 16 (W) 15 Redundant 200 W 63.7 (2344) 62.7 (1862) 40000 63.1 (2042) 62.1 (1622) 250 W 64.7 (2951) 63.7 (2344) 44800 64.1 (2570) 63.1 (2042) PAGE 7 OF 10 214835 REV A ECO 18375

Outdoor MAX General Electrical Specifications PARAMETER NOTES LIMITS UNITS Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Adjustment Maximum, Ku-Band (Auto-Gain Off) Maximum, Ku-Band (Auto-Gain On) Maximum, C- & X-Bands (Auto-Gain Off) Maximum, C- & X-Bands (Auto-Gain On) full band per 40 MHz -40 C to +60 C 0.1 resolution 62 57 70 65 ± 1.0 ± 0.3 ± 1.5 20 /40 MHz Intermodulation Distortion 3 back off relative to P 1-25 c AM/PM Conversion @ rated P 1 3.5 / @ rated P 1-3 1.0 / Spurious Harmonics Input VSWR Output VSWR (@ P 1 ) (@ P 1 ) -65-50 1.30 : 1 2.00 : 1 Noise Figure at maximum gain 12 Group Delay Linear Parabolic Ripple 0.01 0.003 1.0 ns/mhz ns/mhz 2 ns p-p Noise Output Residual AM Noise Residual Phase Noise TX Band RX Band (C-Band, without filter) RX Band (X-Band, without filter) RX Band (X-Band, with filter) RX Band (Ku-Band without filter) RX Band (Ku-Band, with filter) Offset frequency from carrier 1 Hz 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz -75-155 -85-155 -85-155 -110-120 -130-135 -140-140 -140-90 -100-110 -120-125 -130 c c W/4 KHz W/4 KHz W/4 KHz W/4 KHz W/4 KHz W/4 KHz RF Leakage @ 1m, with module removed <0.001 mw/cm 2 True RF Detector Range P sat to (P sat - 20) Accuracy ± 0.5 m PAGE 8 OF 10 214835 REV A ECO 18375

Outdoor MAX L-Band Input Option The Outdoor MAX system can be configured for L-Band Input operation. For optimum RF phase combining over the entire bandwidth of a communication amplifier system, the frequency translation part of the system must be separated from the phase combined loop. Therefore, systems with L-Band input are configured with a separate L-Band block up converter system that feeds the MAX system. Simplified Block Diagram, Redundant Converter Assembly with Outdoor Controller The block up converter system is a 1:1 redundant block up converter assembly with internal redundancy control. The block up converters can be configured with internal or external reference oscillators. The Teledyne Paradise Datacom converter architecture allows a converter that is fitted with an internal reference oscillator to automatically detect and switch to an externally applied 10 MHz reference signal. When a fault is detected in the online converter, the redundancy controller drives the switch to place the standby BUC online without user intervention. If L-Band redundancy is not required, the system can be configured with a single thread block up converter. PAGE 9 OF 10 214835 REV A ECO 18375

Outdoor MAX System Part Number Configuration Matrix Configuration F Four (4) Units E Eight (8) Units S Sixteen (16) Units X Standalone Unit H USE STANDARD SELECTIONS FOR MODULE CONFIG. X Outdoor System High Outdoor s H P A K U 2 0 0 A F H X X X X Band C-Band CC X-Band XX Ku-Band KU ENTER THE SINGLE MODULE POWER LEVEL (in Watts) System Total, P sat Band (# modules) Single (4) - F (8) - E (16) - S C 1318 2512 4677 400 C 1660 3162 5888 500 C 1995 3981 7079 600 X 1175 2239 4169 350 X 1660 3162 5888 500 Ku 661 1259 2344 200 Ku 832 1585 2951 250 The example displayed in the System Part Number Configuration Matrix above shows a 4-unit 200W GaAs Ku-Band system operating at 14.00 to 14.50 GHz. This system does not include the optional Receive Band Reject Filter, AC Distribution Panel or Ethernet switch. The model number is HPAKU200AFHXXXX. Use and Disclosure of Data The items described herein are controlled by the U.S. Government and authorized for export only to the country of ultimate destination for use by the ultimate consignee or end-user (s) herein identified. They may not be resold, transferred, or otherwise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by U.S. law and regulations. Proprietary and Confidential The information contained in this document is the sole property of Teledyne Paradise Datacom. Any reproduction in part or as a whole without the written permission of Teledyne Paradise Datacom is prohibited. Configuration Modifier 3 X Standard (No Switch) E Ethernet Switch Configuration Modifier 2 X Standard (No Filter) R Receive Band Reject Filter Configuration Modifier 1 X Standard AC Distribution X Standard (None) A AC Distribution Panel Frequency Sub Band C-Band 5.850-6.425 GHz A 5.850-6.725 GHz B 5.750-6.670 GHz C 6.425-6.725 GHz E 6.725-7.025 GHz F 5.750-6.475 GHz G 5.715-5.790 GHz H 5.740-6.650 GHz J X-Band 7.900-8.400 GHz A 7.700-8.400 GHz D Ku-Band 14.00-14.50 GHz A 13.75-14.50 GHz B 12.75-13.25 GHz F Specifications are subject to change without notice. PAGE 10 OF 10 214835 REV A ECO 18375