Level gauges Series LT Level indicator, switch and transmitter for liquids

Similar documents
Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Target disk flowmeter for liquids and gases

Metal tube variable area flowmeters for gases, liquids and steam

KFS. Flap-type flow meter. Design and range of application

The transducer component converts the measured signal and displays the actual value.

Digital conductivity transmitter

FLOMID FX Electromagnetic Flowmeter

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Design and applications

Digital inductive conductivity transmitter

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

ED701 General Industry Pressure Transmitter

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Instruction Manual TABLE OF CONTENTS 1 PRINCIPLE OF OPERATION Limitations INSTALLATION Mains connection...

Flow Measurement SITRANS F M

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Resistance thermometers for process technology

Magnetic level indicators made in Australia under licence to Weka AG of Switzerland.

Coriolis Massflowmeter

2-Wire. Level Gauge BM 702

OEM radar transmitter, for aggressive media level measurement

SATRON VB Pressure Transmitter

Radar Level Measurement micropilot FMR 130 for stilling wells

Non-Submersible Industrial Pressure Transducer

Liquid density: from 0,6 g/ml on. Plastic Level Switch NKP Download PDF datasheet

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

FLOAT LEVEL SENSOR TFC. Applications. Reference. Features

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

OPTIMASS 1000 Technical Datasheet

Page Type Resolution (mm) min. max. Output

GUIDED WAVE RADAR TRANSMITTER

TMU. Coriolis Mass Flow Meter. for liquids and gas

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

ATG SERIES Growco Servo Tank Gauges

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Magnetic level switches ERH-xx-20

SM-15. Features. Plastic Flowmeters as per the Variable Area Principle. Description: Application:

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Ambient Conditions. Operating Conditions. Pressure

RCM DIRECT READING FLOWMETER

S103C ELECTROMAGNETIC FLOW METERS. Main application fields MOUNTING

Digital flow transmitter for continuous flow measurement

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Positioner with HART Communication Type 3780

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

OPTIFLUX 5000 Technical Datasheet

Electro-Magnetic Flowmeters COPA-XE

A New Generation of Pressure Transmitters

Sitron Capacitive Level Sensors

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

ECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch

Level measurement Radar

Full Metal Variable Area Flowmeter and Counter Model BGF

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

SALES SERVICE +358 (0)

Relative and absolute pressure transmitter type 528

TIDALFLUX 2300 F Technical Datasheet

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Coriolis Massflowmeter

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

OPTIFLUX 5000 Technical Datasheet

Sales department and calibratiom facilities. R+D, Manufacturing and assembly workshop

OPTIWAVE 1010 Technical Datasheet

Digital flow ELEMENT transmitter for continuous flow measurement

Electromagnetic Flow Transmitter

Rod probe With coaxial tube reference probe

ENRAF SERVO GAUGE 854 ATG Setting the standard in gauging.

Magnetic Inductive Flowmeter

INSTALLATION AND OPERATION MANUAL

Indumax CLS50/CLS50D. Technical Information

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Relative and absolute pressure transmitter type 528

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

Echotel Model 910 Ultrasonic Level Switch

The Radar Level Meters can be installed both in metallic or non metallic tanks; their use is not harmful to humans or environment.

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Georg Fischer Piping Systems Point, Ultrasonic & Radar Level Products

ECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S

Echotel Model 910 Ultrasonic Level Switch

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Coriolis Mass Flow Meter Model TM

Level Measurement With REFLEX RADAR

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

A New Generation of Pressure Transmitters

Transcription:

Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance Measuring range: from 150 mm to 15 m Accuracy: ±4 mm measured value Connections: - EN 1092-1 or ANSI flanges. Other flange standards on request (JIS,...) - BSP or NPT threaded connections - Sanitary couplings according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP Materials: EN 1.4404 (AISI 316L), PVC, PP, PVDF, PTFE, PVC-C. Others on request Local indication: - By means of external float in a glass tube - By means of magnetic strips Options: - Switches. Optional with Ex d IIC T6 Explosion Proof Enclosure (ATEX certified) - Electronic transmitter with 4-20 ma analog output for safe or hazardous area (Ex ia IIC T6 protection, ATEX certified). HART, PROFIBUS, FIELDBUS protocols available on request

Working principle According to communicating vessels principle. A float submersed in a chamber communicated with the tank whose liquid level needs to be measured floats on liquid surface and moves together with it, as level increases or decreases. The float is designed for the specific working liquid density and shows the tank level by means of magnetic coupling with an external float or with a magnetic strips rail (depending on model). Both of them are mounted externally and isolated of the level gauge chamber. Applications Chemical and petrochemical industries Process industry Thermal plants and cryogenic installations Ship industry Boilers Storage installations Models LT.../ : indication by means of external float in a borosilicate glass tube. Graduated scale in cm included. Maximum liquid temperature for AISI 316L versions: 400ºC LTL.../ : indication by means of bi-color magnetic strips (red-white) mounted in an anodized aluminium rail with polycarbonate cover. Optional graduated scale in cm. Maximum liquid temperature for AISI 316L versions: 250ºC Technical data Accuracy: ±4 mm measured value Scale in cm for LT models For LTL models, scale in cm available on request Liquid density: 0.55... 2 kg/l (others on request) Liquid viscosity: 1500 cst maximum Measuring range: 150 mm... 15 m Liquid temperature: - LTL106: -20ºC... 250ºC - LT106: -20ºC... 400ºC, depending on config. - LT... LTL14 / PVC: 0ºC... 45ºC - LT... LTL14 / PP: -10ºC... 90ºC - LT... LTL14 / PVDF: -20ºC... 145ºC - LT... LTL15 / PTFE: -20ºC... 150ºC Working pressure: - Models in AISI 316L: PN16... PN40 (up to 100 bar max. on request) - Models in PVC, PVC-C, PP, PVDF: PN10 - Models in PTFE: PN16... PN40 Connections: - EN 1092-1 or ANSI flanges. Other flange standards on request (JIS,...) - BSP or NPT threaded connections (for LT LTL116) - Sanitary couplings according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP (for LT LTL106) Mounting: vertical, tank side Certificate Type Approval for ship, offshore and industry in general, models LTL106 and LTL116 (up to PN25 / ANSI 150# RF) by Lloyd s Register LT... LTL106 LT... LTL116 LT... LTL14 LT... LTL15 body in AISI 316L, flanged connection body in AISI 316L, threaded connection body in PVC, PVC-C, PP or PVDF body in SS 316L with internal PTFE coating Limit switches and transmitters LT... LTL-APR: adjustable reed switches LT... LTL-AAR: adjustable reed switches (high temperature version) LT... LTL-AMM: adjustable micro-switches LT... LTL-AMD: adjustable inductive switches (+ relays on request) All switches can be supplied in Ex d IIC T6 version on request LTE: Resistive sensor transmitter 0... 4-20 ma: - TR2420: 24 VDC 2-wire system, compact mounted - TR420: 24, 125, 220 VAC, 50/60 Hz / 24 VDC 4-wire system, DIN rail mounted HART, PROFIBUS, FIELDBUS protocols, and Ex version available on request LTDR: Guided radar transmitter 4-20 ma, 4-wire system. Ex version available on request 2

Level gauges Series LT Mounting The lower dimension LD, LP or LPV of series LT level gauges is variable depending on working liquid density. The lower the density, the longer this dimension. In order to remove the float due to a change in density of for maintenance purposes, a minimum distance LMS, longer or equal to LD distance, must be kept between the lowest side of the level gauge and the floor. Model LT... LTL / SS (PN16... 40) LT... LTL / PVC (PN10) LT... LTL / PP (PN10) LT... LTL / PVDF (PN10) Liquid density kg/l Without drain (LD) Lower dimension With drain (LP) With drain + valve (LPV) 0.55... 0.59 430 445 580 0.60... 0.91 340 355 490 0.92 260 275 410 0.60... 0.79 400 525 0.80... 0.89 310 435 0.90 240 365 Without vent (LS) Upper dimension With vent (LV) With vent + valve (LVV) 130 155 290 150 140 265 0.75 240 365 150 165 290 0.80... 0.99 355 480 1.00 245 370 150 165 290 Materials Models LT Models LTL DETAIL A Nº Description Models LT Models LTL EN 1.4404 PVC PP PVDF PTFE EN 1.4404 PVC PP PVDF PTFE 1 Body EN 1.4404 PVC PP PVDF PTFE + PTFE + EN 1.4404 PVC PP PVDF EN 1.4404 EN 1.4404 2.1 Guide tube Borosilicate glass 2.2 Mag strips rail Aluminium + Polycarbonate 3 Float EN 1.4404 / EN 1.4404 / PVC PP PVDF PTFE Titanium Titanium PVC PP PVDF PTFE 4.1 External float PP / Aluminium 4.2 Mag strips POM resin 5 Connection EN 1.4404 PVC PP PVDF PTFE EN 1.4404 PVC PP PVDF PTFE 6 Gasket Belpa Belpa NBR / Viton / EPDM PTFE CSA-50 CSA-50 NBR / Viton / EPDM PTFE 7 End connection EN 1.4404 PVC PP PVDF PTFE EN 1.4404 PVC PP PVDF PTFE 3

Float types Material Liquid density Maximum pressure kg/l bar Titanium 0.55... 0.83 PN40 EN 1.4404 0.84... 2.00 PN40 EN 1.4404 0.77... 2.00 PN63 EN 1.4404 0.81... 2.00 100 PVC 0.60... 2.00 PN10 PP 0.75... 2.00 PN10 PVDF 0.80... 2.00 PN10 EN 1.4404 Titanium Plastic Dimensions and specific technical data Models LT... LTL106... 116 / LT... LTL17 Technical data Material: EN 1.4404 (AISI 316L) Measuring range: 150... 15000 mm (supplied in separate sections for measuring ranges longer than 5500 mm; one single section on request). Longer ranges on request. Liquid temperature: -20ºC... 250ºC: magnetic strips indication -20ºC... 400ºC: glass tube indication Working pressure: PN16... PN40 (up to 100 bar max. on request) Connections: - LT... LTL106: DN15... DN50 EN 1092-1 flanges (other flange standards and sizes on request) - LT... LTL116: G½... G2 threaded connection (other thread standards and sizes on request) Limit switches: LT... LTL-APR / AAR / AMM / AMD Ex d IIC T6 version on request Transmitter LTE 0... 4-20 ma or guided radar LTDR LT LTL106 LT LTL116 4 Separate sections Heating-cooling chamber

Level gauges Series LT Special models LT... LTL17 LT... LTL17P LT... LTL17J LT... LTL17Y Models LT... LTL15 / PTFE Technical data Material: EN 1.4404 (AISI 316L) with internal PTFE coating Measuring range: 6000 mm max. Longer ranges on request Liquid temperature: -20ºC... 150ºC Working pressure: PN16... PN40 Connections: DN15... DN50 EN 1092-1 flanges (other flange standards and sizes on request) Limit switches: LT... LTL-APR / AMM / AMD Ex d IIC T6 version on request Transmitter LTE 0... 4-20 ma or guided radar LTDR Models LT... LTL14 / PP, PVC, PVC-C, PVDF Technical data Material: PP, PVC, PVDF Measuring range: 6000 mm max. Longer ranges on request Liquid temperature: PVC: 0ºC... 45ºC PP: -10ºC... 90ºC / PVDF: -20ºC... 145ºC Working pressure: PN10 Connections: DN15... DN50 EN 1092-1 flanges (other flange standards and sizes on request) Limit switches: LT... LTL-APR / AMM / AMD Ex d IIC T6 version on request Transmitter LTE 0... 4-20 ma or guided radar LTDR 5

Limit switches Adjustable switch LT... LTL-APR SPDT bi-stable reed switch IP65 polycarbonate housing Contact rating: 0.5 A 220 VAC 60 VA Hysteresis: ±6 mm Liquid temperature: -20ºC... 200ºC Ambient temperature: -10ºC... 70ºC Suitable for hazardous area, considered as Simple apparatus Ex d IIC T6 version All switches can be supplied with Ex d IIC T6 Explosion Proof Enclosure on request, ATEX certified LT... LTL-APR Adjustable switch LT... LTL-AAR SPDT bi-stable reed switch Aluminium housing & thermal separator for high temperature Contact rating: 0.5 A 220 VAC 60 VA Hysteresis: ±6 mm Liquid temperature: -20ºC... 400ºC Ambient temperature: -10ºC... 70ºC Suitable for hazardous area, considered as Simple apparatus LT... LTL-AAR Adjustable switch LT... LTL-AMM SPDT bi-stable micro-switch IP65 coated aluminium housing Contact rating: 3 A 220 VAC Hysteresis: ±6 mm Liquid temperature: -20ºC... 200ºC Ambient temperature: -25ºC... 80ºC Mechanical life: 20 x 10 6 operations Suitable for hazardous area, considered as Simple apparatus LT... LTL-AMM / AMD Adjustable switch LT LTL-AMD NAMUR (EN 60947-5-6) 3.5 mm slot type inductive detector activated by vane, mounted in an aluminium housing. Power supply: 8 VDC Hysteresis: ±6 mm Liquid temperature: -20ºC... 200ºC Ambient temperature: -25ºC... +70ºC ATEX certification Ex ia IIC T6 Control relay (on request) NAMUR (EN 60947-5-6) for 1 or 2 inductive detectors. Power supply: 24 253 VAC 50-60 Hz / 24 300 VDC Input: NAMUR Ex ia IIC Output: 1 or 2 relay contacts Output rating: 2 A 250 VAC 100 VA / 1 A 24 VDC Ambient temperature: -25ºC... +70ºC ATEX version Ex d IIC T6 6

Level gauges Series LT Transmitters Transmitter LTE 0... 4-20 ma Transmitter composed of a resistive sensor based on a reed and resistances chain, mounted on a printed circuit placed inside a guide tube. Not wetted by the process liquid. Variations in level inside the tank move the internal LT or LTL float, which by means of magnetic coupling changes the value of the resistance of the resistive sensor in correspondence to the measured liquid level. These variations of resistance are processed by an electronic converter in order to obtain a 0... 4-20 ma current output proportional to liquid level. Technical data LTE Connection by means of IP65 connector, IP67 polycarbonate housing or IP65 aluminium housing Distance between reed switches: 10 mm Liquid temperature: -20ºC... 250ºC Ambient temperature: -20ºC... 60ºC 2-wire system For 2-wire system, the TR2420 resistance/ma converter is supplied, in an IP67 plastic housing or optionally in an IP65 aluminium housing compact mounted on the sensor head. Technical data TR2420 Power supply: 12... 36 VDC, safe area version Power consumption: 0.8 W Output: 4-20 ma Programmable locally or by means of USB cable and software Winsmeter TR available for download at www.tecfluid.com Also available with 2-wire system: TR2420Ex: hazardous area version ATEX Ex ia IIC T6 Power supply: 8... 30 VDC TR2420H (HART protocol), TR2420P (Profibus protocol) or TR2420F (Fieldbus protocol). Also available in combination with their Ex versions Transmitter LTDR LTDR uses TDR (Time Domain Reflectometry) technology. Low-energy, high-frequency electromagnetic impulses, generated by the sensor s circuitry, are propagated along the probe which is immerged in the liquid to be measured. When these impulses hit the surface of the liquid, part of the impulse energy is reflected back up the probe to the circuitry which then calculates the fluid level from the time difference between the impulses sent and the impulses reflected. The sensor can output the analyzed level as a continuous measurement reading through its analog output, or it can convert the values into freely positionable switching output signals. LTDR Sensors are also known as Guided Radars or Guided Wave Radars. For more details, see LTDR guided radar level transmitter datasheet. Available at www.tecfluid.com 4-wire system For 4-wire system the TR420 resistance/ma converter is supplied, DIN 46277 rail mounted. Technical data TR420 Power supply: 24, 110, 230, 240 VAC 50/60 Hz / 24 VDC Power consumption: <1 VA Outputs: 0-20 ma, 4-20 ma, 0-5 V, 0-10 V, 1-5 V, 2-10 V TR420 (remote converter Ω/mA) 7

PRESENCE IN MORE THAN 50 COUNTRIES ALL OVER THE WORLD R-CT-LT Rev. 2 english version Tecfluid S.A. Quality Management System ISO 9001 certified by Narcís Monturiol 33 08960 Sant Just Desvern Barcelona Pressure Equipment Directive 97/23/CE certified by Tel: +34 93 372 45 11 Precision Fax: +34 Fluid 93 Controls 473 44 49 s.r.l. ATEX European Directive 94/9/CE certified by Via tecfluid@tecfluid.com G. Watt, 37 20143 www.tecfluid.com Milano Tel. 0289159270 / Fax 0289159271 HART is a registered trademark of HART Communication Foundation e-mail: precision@precisionfluid.it The technical data described in this specification sheet is subject to modification without notification if the technical innovations in the manufacturing processes so require. VITON is a registered trademark of DuPont Dow Elastomers BELPA is a registered trademark of Montero FyE S.A. TRI-CLAMP is a registered trademark of Alfa Laval Inc.