Alkco is a Philips group brand

Similar documents
Examination, Reading and Ambient lighting

REMEDI. LED Multi-function Bed Light

Ambient Indoor.

Supporting Healthcare Professionals While Enhancing the Patient Experience

Skyline Series. Overbed LED Light. Multiple Directional Light Configurations. 1 Amico Lights Corporation

VEER takes a detour from the ordinary, infusing texture and form into a sleek new direct/ indirect luminaire.

ENR# Enlighted remote (5) WC# wireless control dimming. Specify quantity. Requires 8" blank See integrated controls guide for more details.

E L E G A N C E A N D S O P H I S T I C AT I O N

RECESSED ASYMMETRIC MOUNT

PENDANT MOUNT - DIRECT

finish AP alu. paint D custom UNV * *Please consult factory

Slot 1:10 Scale 1-1/8" (29mm) A G H J. Slot Depth (see chart) (see chart) C K. Return Lip. (see chart)

WALL ASYMMETRIC MOUNT

WALL MOUNT - DIRECT/INDIRECT. Project. Type. Notes

WALL ASYMMETRIC MOUNT

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE NUMBER OF LAMPS VOLTAGE BALLAST ELECTRICAL MOUNTING FINISH CONTROLS OPTIONS


AREA LIGHTING HYPAK SERIES HYPAK - HP3 HYPAK - HP4

WALL HI-OUTPUT. Project. Type. Notes

PENDANT MOUNT ASYMMETRIC

RSS Rectilinear Suspended Series

WALL MOUNT - DIRECT. Project. Type. Notes PRODUCT ID NOM. LUMENS/FT CRI COLOR TEMP. SHIELDING LENGTH

Interior Accent. Lighting. Kaleidoshade 2

FINELITE 10 Year LED Warranty

Video Conference Indirect Wash Fluorescent Fixture

CEILING HI-OUTPUT. Project. Type. Notes

Catalog # Project. Comments. Prepared by

CEILING HI-OUTPUT. Project. Type. Notes

XL 5WAY LIGHT FIXTURE


Metal Halide - Ceramic, Medium Base ED17. H050 50w H070 70w H w H w HPS - Medium Base ED17

Catalog Number LSBT. Example: LSBT6C8T5WD1-BZ QMB. Optics. Type II Type III Type IV Type IV Automotive Type V Medium Type V Wide T2 T3 T4 T4A T5M T5W

(SMS MOUNT SHOWN) Prefix Mounting Optics Lamp Wattage Length Volts Finish Options & Accessories 14W 21W 28W 2' 3', 6' 4', 8' T5HO 2' 3', 6' 4', 8'

LOW LEVEL LE1/2/3. Lantern Bollard. Era. For pathways, courtyards and entrances.

RECESSED MOUNT. Project. Type. Notes

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

Emily Pendant PENDANT

Ceiling Suspended 7480x

Catalog # Project. Comments. Prepared by. Warranty Five year warranty [38mm] 2.71" [69mm]

Kayla Pendant Flush Lens PENDANT

PENDANT MOUNT - DIRECT

Sienna Pendant Drop Lens PENDANT

PENDANT MOUNT - DIRECT. Project. Type. Notes

CEILING HI-OUTPUT. Project: Type: Notes:

T8/T5, 2 X 2 FLUORESCENT RECESSED PARABOLIC WITH 1-1/2 DEEP LOUVERS. (Blank) - MVOLT (120/277) DESCRIPTION

VT & VTTB SERIES. Comfortably illuminates the participants while rendering an excellent video image.

Catalog # Project. Comments. Prepared by. Warranty Five year warranty. 51mm mm 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K

PENDANT MOUNT - DIRECT. Project. Type. Notes

CEILING LO-OUTPUT. Project. Type. Notes

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm 6 152mm -27 = 2700K -30 = 3000K -35 = 3500K -40 = 4000K

CEILING HI-OUTPUT. Project. Type. Notes

RECESSED MOUNT. Project. Type. Notes 1 9/16 PERFORMANCE PER LINEAR FOOT AT 4000K CONTROL SENSORS

HOLH x

Hig h Tra n smissio n L u min a ire s

Dire ct L in e a r L u min a ire s

FLUORESCENT/AREA: NEC/CEC EXPLOSIONPROOF. Applications. Illustrated Features

PENDANT MOUNT DIRECT. (2) D dimming (0-10V) 5% standard

T8/T5, 2 X 4 FLUORESCENT RECESSED PARABOLIC WITH 1-1/2 DEEP LOUVERS DESCRIPTION. Up to 1400 L. for T8 or BX ADV-7 - ADV-7 1 Advance Mark-7 3

RAIL / GRANDE RM2 & RM4 Series. by Metalumen

CAPELLA SERIES. Product Overview and Technical information>>

PENDANT MOUNT - DIRECT/INDIRECT

S u n V a l l e y L i g h t i n g S I G M ATM PATENT PENDING

LUXTRAN Luminaires for Tunnel Applications

VG Series LED Parking Structure Luminaire

WF6 LED - Switchable White

Video Conference Indirect Wash LED Fixture

Basics Series Retrofit LED. Economical 4", 5" and 6" Downlight Trims

AERODOME PARKING/ROADWAY (TYPE III)

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing

LUXTRAN Luminaires for Tunnel Applications

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes

Olivio Grande LED Candelabra Pole Top

Catalog # Project. Comments. Prepared by. Warranty Five year warranty mm mm mm mm

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

R6NC 6" LED Recessed Downlight: Universal New Construction Housing

PENDANT MOUNT - INDIRECT

CONE THROUGH MAXIMUM CANDELA 57.5 (Degrees Vertical)

DCD2 & Commercial Frame Commercial Recessed LED Downlight

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CHROMAWERX OUTPUT WATTAGE. LED - high performance LED

4 EXTRUDED RECTANGULAR SURFACE LX4S

DCD2 & Commercial Frame Commercial Recessed LED Downlight

Olivio Medio LED 5YEAR LED WARRANTY. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type:

Introduction Shank Road Pearland, Texas Fax:

PENDANT INDIRECT. Project. Type. Notes. Lumen/ft up: 1535 lm/ft Total Lumens: 6000 lm (for 4ft) Input Watts: 50.3 W (12.6W/ft) Efficacy: 119 lm/w

CANDELA. Product Data Sheet. LED Technology. Candela

WhiteOptics Reflector based on a highly reflective plastic substrate.

S I M P L I C I T Y A N D S O P H I S T I C AT I O N

Complete product = Frame + Engine + Trim. Series Lumens CRI CCT Beam Dimming Voltage. N Narrow (40 ) M Medium (55 ) W Wide (72 ) 3

PROJECT INFORMATION. Catalog No. REFLECTOR. DRIVER E Fixed Output ED 0-10V Dimming. UPLIGHT ST Solid Top (no uplight)

RTR / LED Troffer Conversion Kit

FFW / LED Flood / Wall Pack Combo

, V E R S AT I N T R I G U I N G S H A P E I L E O P T I C S

LED Luminaires 38 W W W. F I N E L I T E. C O M

Complete Product = Frame-in kit + Light engine + Reflector Order each separately. N Non-IC New construction. Z V Dimming L Lutron.

Panache. Recessed, Surface & Suspended

Linear Sign Lighter. LED and fluorescent lighting for signage, displays and architectural accents. Acuity Brands Juno Linear Sign Lighter

Designed for flexibility and performance, wherever people need durable outdoor luminaries. Paraflood Series

5G350 Nominal 33W 5G530 Nominal 48W 5G700 Nominal 64W 5G105 Nominal 97W 5G140 Nominal 126W K K. 1 DM or HL only. Cannot be combined.

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH3 - Series) imagination at work

Transcription:

Alkco is a Philips group brand

ERAcare is an integrated lighting solution for the patient room environment. It fulfills the requirements for Examination, Reading and Ambient lighting while also simplifying the day-to-day efforts of the healthcare professional and facility maintenance staff. Every aspect of the design is focused on ease of use. Patients and staff alike want the best in care and ERAcare can help meet those expectations.

care for the patient ERAcare delivers the recommended illumination levels for patient reading. The patient s visual comfort is enhanced by the soft, indirect ambient lighting. There are a variety of switching options for patient ease-of-use. Optical compartments are positioned to minimize glare. care for the healthcare professional ERAcare has no moving parts that need to be flipped or rotated. From its soft form to its antimicrobial finish, ERAcare is designed to compliment infectious control efforts. The recommended illumination levels for examination are met. LED night/chart lights and switches are positioned at either end of the luminaire and can be controlled individually or together. care for the facility staff The snap-in lenses provide tool-less lamp replacement. An optional bed shut-off switch minimizes the potential for luminaire damage from motorized patient beds. A removable ballast tray provides quick access to key electrical components.

Integrated Optical Solutions A Lamp Compartments A Ambient C Front Exam C B Reading D Rear Exam D B ERAcare utilizes four separate optical compartments to provide three key illumination requirements for the patient room Exam, Reading and Ambient. These varied functions are integrated into a compact cross-section and can be activated without the need to flip, rotate or mechanically move any part of the luminaire. The needs of the patient and healthcare staff are a flip of the switch away. Function Recommended Levels 1 ERAcare Levels Exam Illumination of the patient bed for examination 50-100 Avg. Footcandles 112 Avg. Footcandles 2 80 Avg. Footcandles 3 Reading Illumination of both the horizontal and angled reading planes 20-50 Avg. Footcandles 65 Avg. Footcandles (horizontal) 54 Avg. Footcandles (angled) Ambient General room illumination 5-10 Avg. Footcandles 12 Avg. Footcandles 1 Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities. 2 Achieved with utilizing the exam and reading optical compartments. 3 Achieved with utilizing the exam optical compartments only. 2 www.alkco.com

Product Details 5 1 4 3 3 2 The small cross-section helps ERAcare blend into the patient room environment. The soft curved form eliminates sharp corners, simplifies cleaning and reduces visual size. 5-1/2 (139.7mm) 8-15/16 (227.3mm) No flat surfaces to sit items on. The die cast end caps and extruded aluminum housing provides durability. 1 Internal linear prisms help maintain a smooth exterior surface that is easy to wipe down. 2 ERAcare s dual exam optical compartments promote better uniformity across the entire patient bed surface. 3 Multiple switching options are available to meet the needs of the installation. 4 The removable socket covers conceal the lamp socket and promote a uniform appearance of the illuminated lens. 5 The Bed Shut-off Switch option minimizes the potential for luminaire damage from motorized patient beds by disconnecting power to the bed when ERAcare is moved. As an option, a set of integrated LED chart/night lights are located at either end of the luminaire. Healthcare staff can conveniently operate these low level lights from both sides of the patient bed. ERAcare meets the most stringent illumination recommendations for exam and reading functions. See chart on page 2. The positive snap-in lenses provide tool-less lamp replacement. A removable ballast tray provides convenient access to key electrical components. ERAcare is available in four standard finishes all with an antimicrobial additive to inhibit the growth of microbes for the life of the product. ERAcare can be complimented with Alkco s WayGlo LED Night Lights. For more information on WayGlo or other Alkco Healthcare solutions, go to www.alkco.com or contact your local Alkco representative. Soft White Taupe Aluminum Almond WG1H WG1V WG2H WG2V www.alkco.com 3

Ambient ERAcare Candela Distribution (1) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing ambient lamp only. Report No.: ITL60756 Model No.: ECT5HO Efficiency: 80.9% 1800 1200 600 180 165 150 135 120 105 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Ambient Illumination Level Recommended Level* 5-10 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 ERAcare 12** * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the ambient optical compartment with (1) F54 T5HO lamp. 90 Visit www.alkco.com for complete Photometric Data LEGEND: 0-deg: 45-deg: 90-deg: Patient Room View 11.0 13.1 15.4 17.5 19.2 20.2 20.2 19.2 17.5 15.4 13.1 11.0 12.1 14.4 16.9 19.3 21.2 22.3 22.3 21.2 19.3 16.9 14.5 12.1 12.4 14.8 17.2 19.5 21.4 22.5 22.5 21.4 19.5 17.2 14.8 12.4 12.0 14.2 16.4 18.5 20.1 21.1 21.0 20.1 18.5 16.4 14.2 12.0 11.2 13.1 14.9 16.6 18.0 18.7 18.7 18.0 16.6 14.9 13.0 11.1 10.0 11.6 13.1 14.4 15.5 16.0 16.0 15.5 14.4 13.1 11.6 10.0 8.8 10.1 11.2 12.2 13.0 13.4 13.4 13.0 12.2 11.2 10.0 8.8 7.6 8.6 9.5 10.3 10.8 11.1 11.1 10.8 10.3 9.5 8.6 7.6 6.6 7.4 8.0 8.6 9.0 9.3 9.2 9.0 8.6 8.0 7.3 6.6 5.7 6.3 6.8 7.3 7.6 7.8 7.8 7.6 7.3 6.8 6.3 5.7 5.0 5.5 5.9 6.3 6.5 6.6 6.6 6.5 6.2 5.9 5.5 4.9 4.4 4.8 5.2 5.5 5.7 5.8 5.8 5.7 5.5 5.2 4.8 4.4 Illumination values calculated at 30 AFF. 4 www.alkco.com

Exam ERAcare Candela Distribution (3) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing 3 lamps (exam and reading). Report No.: ITL60757 Model No.: ECT5HO Efficiency: 64.1% 90 75 1300 60 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 Exam Illumination Level ecommended Level* R 50-100 (Patient bed positioned 30 AFF) ERAcare 112** 80*** 2600 45 3900 0 LEGEND: 0-deg: 45-deg: 90-deg: Patient Room View 15 30 * ** *** Visit www.alkco.com for complete Photometric Data Detail of Exam Surface 156 Exam Surface w ww.alkco.com Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities Achieved utilizing the exam and reading optical compartments with (3) F54 T5HO lamps Achieved utilizing the exam optical compartments with (2) F54 T5HO lamps 183 187 194 219 168 183 231 194 131 155 219 204 148 97.7 186 194 154 108 70.5 168 148 112 76.6 51.4 131 97.6 108 78.8 54.8 38.6 76.5 56.1 40.6 30.1 70.4 54.8 41.3 31.3 51.3 40.6 31.7 38.6 31.7 30.0 5

Horizontal Reading ERAcare Candela Distribution (1) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing reading lamp only. Report No.: ITL60755 Model No.: ECT5HO Efficiency: 74.8% 1300 90 75 60 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Reading Illumination Level (Horizontal Plane) Recommended Level* 20-50 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 ERAcare 65** 2600 45 * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the reading optical compartment with (1) F54 T5HO lamp. 3900 0 15 30 LEGEND: 0-deg: 45-deg: 90-deg: Visit www.alkco.com for complete Photometric Data Patient Room View Detail of Horizontal Reading Surface Horizontal Reading Surface 73.9 86.6 91.3 86.9 68.8 72.4 59.6 48.5 43.2 74.3 69.0 50.5 59.9 43.4 48.6 6 www.alkco.com

Angled Reading ERAcare Candela Distribution (1) 54W T5HO Fluorescent* 4450 lumens per lamp * Testing reading lamp only. Report No.: ITL60755 Model No.: ECT5HO Efficiency: 74.8% 1300 90 75 60 Room Parameters Room Size: 12 x 12 Ceiling Ht.: 8-6 Luminaire Mtg. Ht.: 6 AFF Room Reflectances: 80/50/20 Reading Illumination Level (45 Plane, 47 AFF) Recommended Level* 20-50 ERAcare 54** 2600 45 * Recommendations are from ANSI/IESNA RP-29-06, An IESNA Recommended Practice, Lighting for Hospitals and Health Care Facilities ** Achieved utilizing the reading optical compartment with (1) F54 T5HO lamp. 3900 0 15 30 LEGEND: 0-deg: 45-deg: 90-deg: Visit www.alkco.com for complete Photometric Data Patient Room View Detail of Angled Reading Surface 49.96 52.88 53.41 Angled Reading Surface 58.31 53.96 59.03 51.25 55.87 48.54 53.16 www.alkco.com 7

Product Specifications Luminaire Construction The exterior housing consists of an extruded aluminum body and die cast end caps. The back plate and ballast tray are formed from 18 gauge galvanized steel. Finish ERAcare can be specified in one of four standard polyester powder-coat paint finishes white, taupe, aluminum or almond. Custom finishes are available upon request. A color chip, to match, needs to be provided by the customer. All standard finishes have an antimicrobial additive to inhibit the growth of microbes. Reflectors ERAcare has four separate and unique reflectors roll-formed from specular aluminum. Lens The top ambient lens (top surface) and the front exam lens are both extruded acrylic with DR additive for flexibility over the life of the product. The bottom exam/reading lens is extruded from acrylic. Internal linear prisms help maintain a smooth exterior surface. Removable extruded aluminum socket covers are provided at the ends of each aperture opening to conceal the lamp socket and to create a more uniform appearance across the illuminated lens surface. Lamps ERAcare can be specified with either F54 T5HO, F28 T5 or F32 T8 linear fluorescent lamps. Philips Alto, low mercury lamps are supplied with the luminaire. 3500K is the standard color temperature but alternative color temperatures can be specified. ECO-FRIENDLY Switching The standard switching configuration is an on/off pull cord for the reading compartment with the ambient and exam compartments controlled from a remote wall switch (by others). An optional 4-position pull cord switch (HDS) for sequential control of the ambient and reading compartments is available. The exam function is controlled from a remote wall switch. Pull switches are supplied with a plastic pull cord that is latexfree, stain-resistant, and easy to clean with standard disinfectant. An optional low voltage relay (LVC), that is compatible with industry standard bed control systems (by others), can be field wired for either separate or sequential switching of the ambient and reading compartments. ERAcare can also be specified less switch (LS) with remote switching (by others) controlling all functions. Electrical Electronic high power factor ballasts, rated for 120 and 277 volts, are used. 347 volt ballasts available for T8 lamps only. Ballasts are thermally protected and have a Class A sound rating. T5 and T5HO ballasts have end-of-life protection. Listing UL and CUL Listed. ERAcare is also IBEW labeled. Agion antimicrobial has been listed with the U.S. Food and Drug Administration (FDA), certified by the National Sanitation Foundation (NSF) and registered with the U.S. Environmental Protection Agency (EPA). Installation The back plate is mounted over the electrical junction box or to electrical wiring whip and secured to the wall structure. The housing hooks onto the back plate and is secured with two screws. Lamp replacement is performed by removing the lens and one socket cover. Warranty Limited lifetime warranty on materials and workmanship. Standard manufacturers warranty applies on lamps and ballasts. 8 www.alkco.com

Dimensional Data 8-15/16 (227.3mm) 5-1/2 (139.7mm) Front View Side View 38 (965.2mm) 24 (609.6mm) 5-1/2 A (139.7mm) D B C Back View 16 (406.4mm) Cross Section A. Ambient lamp compartment B. Reading lamp compartment C. Exam lamp compartment D. Rear Exam lamp compartment ECT5HO 48-15/16 (1243.1mm) 48-15/16 ECT5 (1243.1mm) ECT8 (1292.22mm) 50-7/8 Ordering Information Sample Catalog No: ECT5HO - 277 - SWH - HDS - NL NOM. LENGTH Model Number ECT5HO (4) F54 T5HO (Med. Bipin) 4 ECT5 (4) F28 T5 (Med. Bipin) ECT8 (4) F32 T8 (Med. Bipin) Voltage 120 277 3471 1 2 3 4 Finish (standard color is SWH) SWH Soft White TPE Taupe AL Aluminum ALM Almond CC2 Custom Color 347v available for ECT8 only. Customer to provide color chip to match. Not available for 347v applications. Not available with EM1 option. Options HDS LVC3,4 LS EM13 NL3 NL-W3 SBF BSS3 PC 4-position pull cord switch for sequential control of ambient and reading compartments (120v only) Low voltage controller Less switch Emergency ballast LED night/chart light w/dual 3-position rocker switches (120v and 277v) LED night/chart light (remote switch by others), (120v and 277v) Slow blow fuse Bed shut-off switch (120v and 277v) Replacement 6 plastic pull cord (non-latex) Hg Some luminaires use fluorescent or high intensity discharge (HID) lamps that contain small amounts of mercury. Such lamps are labeled Contains Mercury and/or with the symbol Hg. Lamps that contain mercury must be disposed of in accordance with local requirements. Information regarding lamp recycling and disposal can be found at www.lamprecycle.org w ww.alkco.com 9

Alkco is a Philips group brand 11500 Melrose Avenue Franklin Park, IL 60131 Phone (847) 451-0700 Fax (847) 451-7512 www.alkco.com 2008 Philips Group. All rights reserved. Certain products illustrated in this catalog may be protected by applicable patents and patents pending. Alkco will aggressively defend all of its intellectual property. We reserve the right to change details of design, materials and finishes. Printed in the U.S.A. 10/08