Qualification Test Report Summary for the Smiths Connectors Solderless EMI Filtered Connector. STR #569 Revision N/C 2/09/09

Similar documents
QUALIFICATION TEST SUMMARY REPORT ESR-9414 Qualification Type Testing of Amphenol Corporation s 2M805 Series Connector

Sabritec Qualification Test Report Summary

PERFORMANCE SPECIFICATION SHEET

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION. This specification defines the performance, test, quality and reliability requirements of the PwrBlade ULTRA product.

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION

DETAIL SPECIFICATION SHEET

Mar07 Rev B

MAY 14 Rev B

Serial ATA (SATA) Connector

Amphenol Amphenol Taiwan Corporation Sheet 1 of 14

PRODUCT SPECIFICATION

PERFORMANCE SPECIFICATION SHEET CONNECTOR, PLUG, ELECTRICAL, TRIAXIAL, RADIO FREQUENCY (SERIES TRB, PIN CONTACT, CLASS 2)

Feb 13 Rev F

3M IDC Ribbon Cable Socket. Series 891

Qualification Test Report SlimSeal SSL Connector


PRODUCT SPECIFICATION. This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors.

3M High Routability External MiniSAS Cable Assembly 8G26 Series Product Specification Revised

Qualification Test Report Mini-Universal MATE-N-LOK* Connector

GS Product Specification. 1 of 19 N. QSFP+ Cable to Board Connector System 1.0 SCOPE 2.0 PRODUCT DESCRIPTION

PRODUCT SPECIFICATION

This specification covers performance, tests and quality requirements for MINIPAK* HDL Board Mount Receptacle or Plug Connector System.

DETAIL SPECIFICATION SHEET

Mar11 Rev D

Product Data Sheet. 3M Serial Advanced Technology Attachment (SATA) Boardmount Plug, Receptacle and Cable Assemblies

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION

NOV 18 Rev B


DETAIL SPECIFICATION SHEET

Mar11 Rev J

PRODUCT SPECIFICATION

Date: December 10 th, Titre / Title HIGH RELIABILITY RF COAXIAL CONNECTORS SMA 2.9 TYPE, 50 OHMS (FEMALE CONTACT)

SPECIFICATION AND PERFORMANCE CHARACTERISTICS SERIAL ATA CABLE ASSEMBLIES

MILITARY SPECIFICATION SHEET COILS, RADIO FREQUENCY, MOLDED, ENCAPSULATED, VARIABLE, MICRO-MINIATURE, IRON CORE, TYPES LT11V001 TO LT11V021 INCL.

PRODUCT SPECIFICATION

SEP 15 Rev A

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943


FIELD CORRELATED LIFE TEST SUPPLEMENT TO SAE/USCAR-2 SUMMARY OF CONTENTS 1. SCOPE OUTLINE REFERENCED DOCUMENTS EQUIPMENT...

MILITARY SPECIFICATION SHEET TRANSFORMER, POWER, STEP-DOWN, AUTOTRANSFORMER. Inactive for new design after 13 March 1991

FILTER RACK & PANEL. connectors

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

DETAIL SPECIFICATION SHEET

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

SECTION 7 R114 / R115 / R116 / R117 / R112

USS RF I plug Connector series

PRODUCT SPECIFICATION

RF COAXIAL CONNECTORS, BASED ON TYPE SMP. ESCC Detail Specification No. 3402/0xx

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

Date: May 17 th, 16. Titre / Title HIGH RELIABILITY RF COAXIAL CONNECTORS SMP TYPE, 50 OHMS

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO INCHES OUTSIDE DIAMETER, 50 OHMS

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY AND MICROPHONE, DYNAMIC, M26542/9-01 AND M-133/U

Date: April 27 th, 07. Titre / Title HIGH RELIABILITY RF COAXIAL CONNECTORS SMA TYPE, 50 OHMS (FEMALE CONTACT)

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH

DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 10 AMPERES, 2 PDT TYPE I, MAGNETIC LATCH, STUD MOUNTED, SOLDER HOOKS, HERMETICALLY SEALED

Test Report. Ochito 10G Ethernet contacts Glenair Part #s: & Qualification Test Report

JULY 15 Rev A

Date: November 8 th, Titre / Title HIGH RELIABILITY. RF COAXIAL CONNECTORS for SMP Lock connectors GENERIC SPECIFICATION

Space Level Screening Services

I-PEX MHF3 Micro Coaxial Connector Mating Heigh: 1.5mm MAX

PRODUCT SPECIFICATION. Single and Multi-Port Jack Assemblies 1 of 26 L

OPEN BASE STATION ARCHITECTURE INITIATIVE

I-PEX MHF Micro Coaxial Connector Applicable Cable for O.D. 1.37mm Cable

RF COAXIAL CONNECTORS

JANUARY 30, 2012 TEST REPORT #211630B MIXED FLOWING GAS TESTING IPS1/IPT1 CONNECTOR SERIES SAMTEC, INC.

SMA - 50 Ohm Connectors

WIRE WOUND CHIP INDUCTORS HCI SERIES HCI 0805 F T 1R0 K - Introductions. Features. Part Number Code HCI SERIES

DETAIL SPECIFICATION SHEET

Screening and Qualification Inspection for Coaxial Attenuators

CONNECTORS, ELECTRICAL, CIRCULAR, TRIPLE-START SELF-LOCKING COUPLING, SCOOP-PROOF, REMOVABLE CRIMP CONTACTS BASED ON MIL-C SERIES III

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPES 7203 AND 7203A

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET TRANSFORMERS, AUDIO FREQUENCY, MICRO-MINIATURE

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, FLANGE MOUNTING, MINIATURE, CLASSES E, F, G AND R

HIGH RELIABILITY SEMI-RIGID COAXIAL CABLE ASSEMBLIES

DEFENSE LOGISTICS AGENCY DLA LAND AND MARITIME POST OFFICE BOX 3990 COLUMBUS, OH

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, MODULAR, TYPE IV, CONNECTOR, 200 CONTACT, CENTER

Switch, DIP, Standard 7100 Series

SMA 50 Ohm Connectors Alphabetical Index INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE ON REQUEST

PRODUCT SPECIFICATION

PERFORMANCE SPECIFICATION SHEET SWITCH, ASSEMBLIES, SENSITIVE, TRIGGER, 7 AMPERES, UNSEALED

FIGURE 1. Design, dimensions, and circuit diagram.

SMB Connectors. RF Coax Connectors. Product Facts

RF COAXIAL PHASE SHIFTER SMA DC to 18 GHz DETAIL SPECIFICATION

DETAIL SPECIFICATION SHEET


PERFORMANCE SPECIFICATION SHEET SWITCH, SENSITIVE, LIMIT, HERMETIC SEAL

18093-PS PHIHONG TECHNOLOGY CO., LTD. General Specification PSM (DC)

DETAIL SPECIFICATION SHEET

Product Specification. 3M Cable Assemblies for QSFP+ FDR Applications, Copper

SECTION 5 SWITCHING CONNECTORS/MOEBIUS MC-CARD/RP-MCX R199/R299 SIMPLIFICATION IS OUR INNOVATON. Visit for more information

3M TM High Routability Internal MiniSAS Cable Assembly, Series 8F36

WIRE WOUND CHIP INDUCTORS SWI SERIES

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, SINGLE HOLE MOUNT, MINIATURE, CLASSES E, F, G, H AND R

TEST SUMMARY MINI-FIT JR. CONNECTOR SYSTEM STANDARD AND BLIND MATE INTERFACE (BMI) (WIRE TO PCB AND WIRE TO WIRE)

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, FLANGE MOUNTING, MINIATURE, CLASSES E, F, G AND R

Transcription:

for the Smiths Connectors Solderless EMI Filtered Connector Revision N/C 2/09/09

Revision Page Paragraph Description of Revision Approval Letter Number / Appendix Date N/C - - Original Release 2/6/2009 2

Table of Contents 1 Scope... 5 2 Order of Precedence... 5 3 Description of Test Articles... 5 4 Standard Ambient Test Conditions... 5 5 References...5 6 Test Equipment and Facilities... 5 6.1 Test Equipment... 5 6.2 Facilities... 6 7 Calibration... 6 8 Test Sequence... 6 9 Test Results...7 10.0 Test Procedures 8 10.1 Initial Electrical Tests... 10 10.1.1 Dielectric Withstanding Voltage... 10 10.1.2 Insulation Resistance... 10 10.1.3 Attenuation... 11 10.1.4 Ground Resistance... 11 10.1.5 Capacitance... 11 10.2 Temperature Cycling... 11 10.3 Ground Resistance... 11 10.4 Capacitance... 11 10.5 Insulation Resistance at Elevated Temperature... 11 10.6 Dielectric Withstanding Voltage (DWV at Sea Level and Altitude)... 12 10.7 Ground Resistance... 13 10.8 Capacitance... 14 10.9 Durability... 14 10.10 Ground Resistance... 14 10.11 Capacitance... 14 10.12 Vibration... 14 10.13 Ground Resistance... 14 10.14 Capacitance... 15 10.15 Shock... 15 10.16 Ground Resistance... 15 10.17 Capacitance... 15 3

10.18 Attenuation... 15 10.19 Humidity... 15 10.20 Insulation Resistance... 16 10.21 Dielectric Withstanding Voltage... 16 10.22 Insert Retention... 17 10.23 Contact Retention... 17 10.24 Final Inspection... 18 10.24.1 Dielectric Withstanding Voltage... 18 10.24.2 Insulation Resistance... 19 10.24.3 Attenuation... 19 10.24.4 Ground Resistance... 19 10.24.5 Capacitance... 19 Appendix A Customer Use Drawing (116431-5349)... 20 4

1 Scope The purpose of this document is to summarize the test results documented in Smiths Connectors Report (QTR) 679, which defined the test samples, test sequence, and test methods, used in the qualification of Sabritec s solderless filter connector design to the requirements as applicable from MIL-DTL-38999. 2 Order of Precedence In case of a conflict between the text of this document and the applicable referenced documents, the text of this document shall take precedence. 3 Description of Test Articles Smiths Connectors internal part number, customer part number, quantity tested, and a general description of articles that were tested to the requirements of this document are as in Table 1. Table 1: Connector Part Numbers and Descriptions. Customer Part Quantity General Description Part Number Number 116431-5349 N/A 5 Solderless filter connector 4 Standard Ambient Test Conditions All tests and examinations specified by this qualification test procedure were continued under any combination of conditions within the ranges stated in this paragraph, unless specified otherwise. Temperature: 21 C to 27 C Relative Humidity: 20% to 80% Barometric Pressure: 725 +50/ 70 mm Hg 5 References MIL-STD-1344 Test Methods for Electrical Connectors MIL-STD-202 Test Methods for Electronic and Electrical Components Parts 6 Test Equipment and Facilities 6.1 Test Equipment Table 2 lists the equipment used during the performance of the testing completed herein. 5

Table 2: Test Equipment Manufacturer Description and Model Smiths Connectors S/N Megohmmeter Insulation Resistance Model 1863 296 Sun System Chamber for Temp. Cycling Test Model EC11 274 Sun System Chamber for Temp. Cycling Test Model EC13HA 299 Associated Research AC/DC Hypot Tester for DWV Model 4450DT 130 Mitutoyo Caliper for visual inspect Model 505-637-50 059 CTI DWV, IR, and Capacitance Test System Model 4087 347 Derek Vacuum Tech. Vacuum chamber for Altitude Test Model N/A N/A Cecomp Electronics Falcon ARM760B manometer gauge Model N/A 991 Thermotron Humidity Chamber Model N/A 058 Chatillon Push-Pull Test Model TCM-500 044 Chatillon Force Gauge Model DPP10 249 Bake Test Indicator Model N/A 114 Agilent Technology RF Analyzer Model E5071B 1353 HP RF Analyzer Model 8713B 1540 Analogic Multimeter Model DP100 037 Topward Electric Instrument Co. Power Supply Model TPS-2000 099 6.2 Facilities Smiths Connectors used its own facilities for testing and that of National Technical Systems (NTS), Fullerton, CA. 7 Calibration All test equipment used in the performance of the tests required herein were calibrated in accordance with ANSI/NCSL Z540-1-1994. Records of all equipment are maintained in accordance with ANSI/NCSL Z540-1-1994 and made available for review. Unless otherwise specified, Smiths Connectors Quality Assurance verified that all test data and collection methods were accurate and reliable. 8 Test Sequence The test procedures were conducted as one (1) group of test sequences. The group consisted of Sabritec s Solderless Filter Design Connector part number 116431-5349 which is based on MIL- DTL-38999, Series III, Size 25, Arrangement 35, pin interface with pc-tail terminations. The front interface dimensions of this receptacle connector fully meet the requirements of MIL-DTL-38999. The connectors went through the listed tests in the order specified. 6

Table 3: Test Sequence Test Procedure (QTP #679) Paragraph Reference 9.1 Initial Electrical Tests 9.2 Temperature Cycling 9.3 Ground Resistance 9.4 Capacitance 9.5 Insulation Resistance at Elevated Temperature 9.6 Dielectric Withstanding Voltage (Sea Level and Altitude) 9.7 Ground Resistance 9.8 Capacitance 9.9 Durability 9.10 Ground Resistance 9.11 Capacitance 9.12 Vibration 9.13 Ground Resistance 9.14 Capacitance 9.15 Shock 9.16 Ground Resistance 9.17 Capacitance 9.18 Attenuation 9.19 Humidity 9.20 Insulation Resistance 9.21 Dielectric Withstanding Voltage 9.22 Insert Retention 9.23 Contact Retention 9.24 Final Inspection 9 Test Results Test Procedure Initial Electrical Tests Dielectric Withstanding Voltage Initial Electrical Tests Insulation Resistance Initial Electrical Tests Attenuation Initial Electrical Tests Ground Resistance Para. Ref. /Fail Criteria (from original QTR #679) 9.1.1 DWV was tested per the requirements of MIL- STD-1344, method 3001, test conditions I (sea level). The magnitude of voltage was 500 VDC minimum. 9.1.2 Connectors did have a minimum insulation resistance of 5 Giga ohms at 200 VDC, when tested in accordance with MIL-STD-1344, Method 3003. 9.1.3 Each connector was subjected to Attenuation per the requirements of MIL-STD-220B. Only the contact with the lowest capacitance value for each filter band was tested for attenuation with the provided data sheet. 9.1.4 In accordance with MIL-STD-202, Method 307, the maximum resistance for grounded contacts was 5 milliohms when measured from contact to connector shell. Results 7

Initial Electrical Tests Capacitance Temperature Cycling 9.1.5 In accordance with MIL-STD-202, Method 305, test frequency 1 KHz +/- 0.1 KHz, and test voltage 1.0 VAC (RMS), the capacitance did meet the values as specified in Table 4 at ambient temperature. The capacitance measurements did have an allowable tolerance of ±20%. Pins 4, 11, 16, 23, 59, 60, 64, 69, 70, 106, 113, 118, and 125 are grounded to the shell. All other pins have a capacitance of 20,000 pf ± 20%. 9.2 Mated connectors were subjected to the temperature cycling of MIL-STD-1344, Method 1003, test condition A, except that steps 2 and 4 were of 2 minutes maximum duration. The temperatures of step 1 were 55 o C to +125 o C. Ground 9.3 See paragraph 9.1.4. Resistance Capacitance 9.4 See paragraph 9.1.5. Insulation Resistance at Elevated Temperature Dielectric Withstanding Voltage (Sea Level and Altitude) 9.5 Connectors did have a minimum insulation resistance of 1 Giga ohms, when tested in accordance with MIL-STD-1344, Method 3003, at 125 o C at the 200 VDC. 9.6 DWV was tested per the requirements of MIL- STD-1344, method 3001, test conditions I (sea level) and IV (altitude, 70,000ft). The magnitude of voltages was 500 VDC at sea level and 300 VDC at 70,000 feet. Ground 9.7 See paragraph 9.1.4. Resistance Capacitance 9.8 See paragraph 9.1.5. Durability 9.9 Connectors were subjected to 500 mating cycles at a maximum rate of 300 cycles/hour. The mating and unmating was accomplished so that the plug and receptacle were completely separated during each cycle. The test connectors showed no defects detrimental to the operation of the connectors. Ground 9.10 See paragraph 9.1.4. Resistance Capacitance 9.11 See paragraph 9.1.5. Vibration 9.12 Connectors have met the requirements for vibration in accordance with MIL-STD-1344, Method 2005, Test Condition VI, Letter J for 8 hours with no electrical discontinuity and no disengagement of mated connectors. The characteristics of Test Condition Letter J can be seen in Table 7 below. This test was performed at an outside test lab. Ground 9.13 See paragraph 9.1.4. Resistance Capacitance 9.14 See paragraph 9.1.5. 8

Shock 9.15 Connectors have met the requirements for shock in accordance with MIL-STD-1344, Method 2004, Test Condition D with no electrical discontinuity and no disengagement of mated connectors. A detector capable of detecting a discontinuity of 1 microsecond was used. This test was performed at an outside test lab. Ground 9.16 See paragraph 9.1.4. Resistance Capacitance 9.17 See paragraph 9.1.5. Attenuation 9.18 Each connector was subjected to Attenuation per the requirements of MIL-STD-220B. Only the contact with the lowest capacitance value for each filter band was tested for attenuation with the provided data sheet. Humidity 9.19 Wired and mated connectors were subjected to the Humidity test specified in method 1002 of MIL- STD-1344. The following details applied: Test condition letter Type II The mated connectors were mounted in the vertical position. Step 7a was performed in the last 5 cycles. Three hours minimum after the start of step 7a during the final cycle and while the connectors were still subjected to high humidity, the insulation resistance was measured when the chamber temperature reached 20 C ±5 and condensation was observed on the connector. For qualification testing, insulation resistance was made on 50 percent of the circuits. Outer circuits were measured to the connector shell. Wired and mated connectors showed no deterioration which would adversely affect performance of the connector. Following the test, and during the final cycle, insulation resistance was 100 mega ohms or greater. Note: Connector was tested with rear pc-tails sealed in a block with an o-ring to seal the surface as this configuration would normally be utilized by the user in a similar fashion. Insulation 9.20 See paragraph 9.1.2. Resistance Dielectric Withstanding 9.21 DWV was tested per the requirements of MIL- STD-1344, method 3001, test conditions I (sea Voltage level). The magnitude of voltages was 500 VDC. Insert Retention 9.22 Insert retention was tested per the requirements of MIL-STD-1344, method 2010, unless otherwise specified. The minimum contact retention force and/or maximum deflection followed the requirements of MIL-DTL-38999. Contact Retention 9.23 Contact Retention was tested per the requirements of MIL-STD-1344, method 2007, unless otherwise specified. The minimum contact 9

retention force and/or maximum deflection followed the requirements of MIL-DTL-38999. Final Inspection Dielectric Withstanding Voltage Final Inspection Dielectric Withstanding Voltage Final Inspection Dielectric Withstanding Voltage Final Inspection Dielectric Withstanding Voltage Final Inspection Capacitance 9.24.1 See paragraph 9.1.1. 9.24.2 See paragraph 9.1.2. 9.24.3 See paragraph 9.1.3. 9.24.4 See paragraph 9.1.4. 9.24.5 See paragraph 9.1.5. 10.0 Test Procedures 10.1 Initial Electrical Tests 10.1.1 Dielectric Withstanding Voltage DWV was tested per the requirements of MIL-STD-1344, method 3001, test conditions I (sea level). The magnitude of voltage was 500 VDC minimum. Connector assemblies were tested for the requirements of Dielectric Withstanding Voltage. The test voltage for connectors was applied between the most closely spaced contacts and between connector shell and the contact closest to the shell. Test voltage was 500 Vdc. The test voltage was raised from zero to the specified value as uniformly as possible, at a rate of approximately 500 volts rms per second, for 5-10 seconds between each contact and the shell, leakage current did not exceed 500 microamperes. Connector assemblies met the requirements of Dielectric Withstanding Voltage. 10.1.2 Insulation Resistance Connectors had a minimum insulation resistance of 5 Giga ohms at 200 VDC, when tested in accordance with MIL-STD-1344, Method 3003. Connector assemblies have met the requirements for the Insulation Resistance testing. The test voltage was at 200 VDC, ±10 percent, and maintained a minimum insulation resistance of 5 Giga ohms. 10

10.1.3 Attenuation Each connector was subjected to Attenuation per the requirements of MIL-STD-220B. Only the contact with the lowest capacitance value for each filter band was tested for attenuation with the provided data sheet. Connector assemblies have met the requirements for the Attenuation at Ambient Temperature testing. Discrete measurements were made at 0.5, 1, 5, 20, 100, 500, and 1000 MHz. 10.1.4 Ground Resistance In accordance with MIL-STD-202, Method 307, the maximum resistance for grounded contacts was 5 milliohms when measured from contact to connector shell. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307. 10.1.5 Capacitance In accordance with MIL-STD-202, Method 305, test frequency 1 KHz +/- 0.1 KHz, and test voltage 1.0 VAC (RMS), the capacitance did meet the values as specified in Table 4 at ambient temperature. The capacitance measurements did have an allowable tolerance of ±20%. Table 4 Capacitance Values Contact Locations Capacitance (nf) 4, 11, 16, 23, 59, 60, 64, 69, 70, 106, Ground 113, 118, 125 All others 20 nf Connector assemblies have met the requirements for the Capacitance to Ground testing. 10.2 Temperature Cycling Mated connectors were subjected to the temperature cycling of MIL-STD-1344, Method 1003, test condition A, except that steps 2 and 4 were of 2 minutes maximum duration. The temperatures of step 1 were 55 o C to +125 o C. Connectors have met the requirements for the Temperature Cycling. 10.3 Ground Resistance Refer to paragraph 10.1.4. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307s. 10.4 Capacitance Refer to paragraph 10.1.5 Connector assemblies have met the requirements for the Capacitance to Ground testing. 11

Smiths Connectors 10.5 Insulation Resistance at Elevated Temperature Connectors had a minimum insulation resistance of 1 Giga ohms, when tested in accordance with MIL-STD-1344, Method 3003, at 125 oc at the 200 VDC. Figure 1 Insulation Resistance at Elevated Temperature Connector assemblies have met the requirements for the Insulation Resistance testing at Elevated Temperature The test voltage was at 200 VDC, ±10 percent, and maintained a minimum insulation resistance of 5 Giga ohms. 10.6 Dielectric Withstanding Voltage (DWV at Sea Level and Altitude) DWV was tested per the requirements of MIL-STD-1344, method 3001, test conditions I (sea level) and IV (altitude, 70,000ft). The magnitude of voltages is specified in Table 5 below. 12

Smiths Connectors Table 5 DWV at Sea Level and Altitude Altitude Level Sea Level 70,000 ft Voltage Requirement 500VDC 300 VDC Figure 2 DWV at Altitude Connector assemblies were tested for the requirements of Dielectric Withstanding Voltage at Sea Level and Altitude. The test voltage for connectors was applied between the most closely spaced contacts and between connector shell and the contact closest to the shell. Test voltage was 500 Vdc @ Sea Level and 300 VDC @ 70,000 ft. The test voltage was raised from zero to the specified value as uniformly as possible, at a rate of approximately 500 volts rms per second, for 5-10 seconds between each contact and the shell, leakage current did not exceed 500 microamperes. Connector assemblies met the requirements of Dielectric Withstanding Voltage. 10.7 Ground Resistance Refer to paragraph 10.1.4. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307. 13

10.8 Capacitance Refer to paragraph 10.1.5 Connector assemblies have met the requirements for the Capacitance to Ground testing. 10.9 Durability Connectors were subjected to 500 mating cycles at a maximum rate of 300 cycles/hour. The mating and unmating was accomplished so that the plug and receptacle are completely separated during each cycle. The connectors showed no defects detrimental to the operation of the connectors. 10.10 Ground Resistance Refer to paragraph 10.1.4. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307. 10.11 Capacitance Refer to paragraph 10.1.5 Connector assemblies have met the requirements for the Capacitance to Ground testing. 10.12 Vibration Connectors have met the requirements for vibration in accordance with MIL-STD-1344, Method 2005, Test Condition VI, Letter J for 8 hours with no electrical discontinuity and no disengagement of mated connectors. The characteristics of Test Condition Letter J can be seen in Table 7 below. This test was performed at an outside test lab. Table 6 Values for Test Condition VI Characteristics Test Condition Letter Power spectral density Overall G rms J 1.0 41.7 The connector passed the Vibration requirements stated above. This vibration test was performed at NTS. 10.13 Ground Resistance Refer to paragraph 10.1.4. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307. 14

10.14 Capacitance Refer to paragraph 10.1.5 Connector assemblies have met the requirements for the Capacitance to Ground testing. 10.15 Shock Connectors met the requirements for shock in accordance with MIL-STD-1344, Method 2004, Test Condition D with no electrical discontinuity and no disengagement of mated connectors. A detector capable of detecting a discontinuity of 1 microsecond was used. This test was performed at an outside test lab. The connectors passed the shock test requirements stated above. This test was performed at NTS. 10.16 Ground Resistance Refer to paragraph 10.1.4. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307. 10.17 Capacitance Refer to paragraph 10.1.5 Connector assemblies have met the requirements for the Capacitance to Ground testing. 10.18 Attenuation Each connector was subjected to Attenuation per the requirements of MIL-STD-220B. Only the contact with the lowest capacitance value for each filter band was tested for attenuation with the provided data sheet. Connector assemblies have met the requirements for the Attenuation at Ambient Temperature testing. Discrete measurements were made at 0.5, 1, 5, 20, 100, 500, and 1000 MHz. 10.19 Humidity Wired and mated connectors were subjected to the Humidity test specified in method 1002 of MIL-STD-1344. The following details applied: Test condition letter Type II The mated connectors were mounted in the vertical position Step 7a was performed in the last 5 cycles Three hours minimum after the start of step 7a during the final cycle and while the connectors are still subjected to high humidity, the insulation resistance was measured when the chamber temperature reaches 20 C ±5 and condensation was observed on the connector. For qualification testing, insulation resistance measurements were made on 50 percent of the circuits. Outer circuits were measured to the connector shell. 15

Smiths Connectors Wired and mated connectors showed no deterioration which would adversely affect performance of the connector. Following the test, and during the final cycle, insulation resistance was 100 mega ohms or greater. Figure 3 Humidity Connector assemblies have met the requirements for the Humidity testing. Wired and mated connectors showed no signs of deterioration. 10.20 Insulation Resistance Connectors did have a minimum insulation resistance of 5 Giga ohms at 200 VDC, when tested in accordance with MIL-STD-1344, Method 3003. Connector assemblies have met the requirements for the Insulation Resistance testing at Elevated Temperature The test voltage was at 200 VDC, ±10 percent, and maintained a minimum insulation resistance of 5 Giga ohms. 10.21 Dielectric Withstanding Voltage Refer to paragraph 9.9, sea level condition only. Connector assemblies were tested for the requirements of Dielectric Withstanding Voltage. The test voltage for connectors was applied between the most closely spaced contacts and between connector shell and the contact closest to the shell. Test voltage was 500 Vdc. The test voltage 16

was raised from zero to the specified value as uniformly as possible, at a rate of approximately 500 volts rms per second, for 5-10 seconds between each contact and the shell, leakage current did not exceed 500 microamperes. Connector assemblies met the requirements of Dielectric Withstanding Voltage. 10.22 Insert Retention Insert retention was tested per the requirements of MIL-STD-1344, method 2010, unless otherwise specified. The minimum contact retention force and/or maximum deflection followed the requirements of MIL-DTL-38999. Figure 4 Insert Retention Connector assemblies were tested for the requirements of Insert Retention. Connector assemblies met the requirements of Insert Retention. 10.23 Contact Retention Contact Retention was tested per the requirements of MIL-STD-1344, method 2007, unless otherwise specified. The minimum contact retention force and/or maximum deflection followed the requirements of MIL-DTL-38999. 17

Figure 5 Contact Retention Connector assemblies were tested for the requirements of Contact Retention. Connector assemblies met the requirements of Contact Retention. 10.24 Final Inspection 10.24.1 Dielectric Withstanding Voltage Refer to paragraph 10.1.1. Connector assemblies were tested for the requirements of Dielectric Withstanding Voltage. The test voltage for connectors was applied between the most closely spaced contacts and between connector shell and the contact closest to the shell. Test voltage was 500 Vdc. The test voltage was raised from zero to the specified value as uniformly as possible, at a rate of approximately 500 volts rms per second, for 5-10 seconds between each contact and the shell, leakage current did not exceed 500 microamperes. Connector assemblies met the requirements of Dielectric Withstanding Voltage. 18

10.24.2 Insulation Resistance Refer to paragraph 10.1.2. Connector assemblies have met the requirements for the Insulation Resistance testing at Elevated Temperature The test voltage was at 200 VDC, ±10 percent, and maintained a minimum insulation resistance of 5 Giga ohms. 10.24.3 Attenuation Refer to paragraph 10.1.3. Connector assemblies have met the requirements for the Attenuation at Ambient Temperature testing. Discrete measurements were made at 0.5, 1, 5, 20, 100, 500, and 1000 MHz. 10.24.4 Ground Resistance Refer to paragraph 10.1.4. The Connectors have met the requirements for the Ground Resistance testing. The Ground Resistance was measured in accordance with MIL-STD-202, Method 307. 10.24.5 Capacitance Refer to paragraph 10.1.5. Connector assemblies have met the requirements for the Capacitance to Ground testing. 19

Appendix A Customer Use Drawing (116431-5349) 20