Intel Corporation. Corporate Product Regulations. Ferrite Clamp/Tube Analysis CISPR/G/143/CDV. 22 December 1999

Similar documents
T A B L E O F C O N T E N T S DESCRIPTION PAGE

Sunlight Supply, Inc.

ENGINEERING TEST REPORT

Sunlight Supply, Inc.

Sunlight Supply, Inc.

Compliance Engineering Ireland Ltd

TEST REPORT. Table of Contents

Test Site Services, Inc. P.O. Box 766 Marlboro, MA U.S.A. Phone/Fax: (508)

C E R T I F I C A T I O N

APPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer

C E R T I F I C A T I O N

FCC Part 15 Subpart B

TEST REPORT. Table of Contents

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

Spurious Emissions & Emission Mark Report

FCC Rules and Regulations / Intentional Radiators. Operational in the MHz, MHz, MHz, and

STC Test Report. The Hong Kong Standards and Testing Centre Ltd.

Global EMC Inc. Labs EMC & RF Test Report TVTXP916A04

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

STC Test Report. Date: Page 2 of 25 No.: MH The Hong Kong Standards and Testing Centre Ltd.

FCC CLASS B COMPLIANCE REPORT (DoC)

ENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): BB-BONE-000 IN ACCORDANCE WITH: CFR 47, PART 15, SUBPART B, CLASS B VERIFICATION

FCC 47 CFR PART 15 SUBPART B

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

STC Test Report. Date : Page 1 of 13 No. : HM161169

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Declaration of Conformity (DoC)

FCC 47 CFR PART 15 SUBPART B TEST REPORT

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

QI HARDWARE INC. Ben NanoNote. Model: Ben NanoNote September Report No.: (This report supersedes NONE)

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

Stimwave Technologies, Inc.

CERTIFICATE. Issued Date: Apr. 20, 2006 Report No.: 064L079-IT-US-P01V01

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

Matric Limited Hill City Road R.R. #1 Box 421A Seneca, PA 16346

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

9. MAXIMUM CONDUCTED OUTPUT POWER SPECTRAL DENSITY

HongAn TECHNOLOGY CO., LTD. Report Number: HA VI i

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR THE FUEL WEB, INC. GATEWAY MODULE MODEL: GWM-P-SHRF-1 FCC ID: PX5-GWM1001

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

REVISION HISTORY. The revision history for this document is shown in table. HCT-EM-1801-FC037 January 22, 2018 Initial Release

Page 1 of 20 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

C-Tick EMC TEST REPORT. For. AC/DC Switching Power Supply

Test Report No

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

EMC COMPLIANCE TEST REPORT

TRANSMITTER MODEL: KAS-2030M

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

King Pigeon Communication Co., Limited

Table of Contents Page Total Page 7 1. General Information

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

ENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): MB-PRO-MVK, MCU-430F5438A-MVK, AFE-BREAKOUT-MVK, RF-BREAKOUT-MVK, & RF-TCA8418-MVK

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

CERTIFICATE. Issued Date: Apr. 02, 2009 Report No.: R-ITUSP01V01

RF test report AU01+W02

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

FCC DoC TEST REPORT. TESTED : Sep. 01 to 02, 2010 APPLICANT : LOGITECH FAR EAST LTD.

TRANSMITTER Model: TX24

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

Report No.: 11A080304E-E Page 1 of 35. CE Test Report. (Declaration of Conformity) for. Electromagnetic Compatibility.

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

Quality Auditing Institute # Schoolhouse Street, Coquitlam, BC, V3K 4X9, Canada. ISO Accreditation:

ICES-003, Issue 5, August Radiated and Conducted Emissions VCCI. Member #: 2649 Registration #: A-0170 R-3273 C-3642 T-1756 G-233

Normalized Site Attenuation Test Report

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

416 Maetan 3-Dong, Yeongtong-Gu, Suwon-Si, Gyeonggi-Do, Korea,

Test Report. Product Name: Cable Modem Model No.: BEFCMU10 ver.3 FCC ID. : Q87-BEFCMU10V3

FCC Verification TEST REPORT

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Electromagnetic Compatibility Test Report. Datamax Corp

Honeywell, Automation and Control Solutions

Nemko Canada Inc., 303 River Road, R.R. 5, Ottawa, Ontario, Canada, K1V 1H2

Page 1 of 19 No.: HM TEST REPORT FCC PART 15 SUBPART C CERTIFICATION REPORT FOR LOW POWER TRANSMITTER. TEST REPORT No.

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

ECHOSTAR 54.0 BRISBANE VOICE REMOTE 2017 MODEL: URC-2027BC0-R

Test Report. Product Name : Access Point Model No.: MS-6809 FCC ID.: I4L-MS6809

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

DATE: 25 September 2012 I.T.L. (PRODUCT TESTING) LTD. FCC EMC Test Report. (Equipment Authorization Under FCC Verification Process) for

FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR DUAL RADIO OUTDOOR ACCESS POINT MODEL NUMBER: AP-ONE FCC ID: SWX-AP1R2

EMC Test Report. Information Technology Equipment Class B Digital Device. FCC Part 15 Industry Canada ICES-003 Issue 4

EMC Test Report AP5130DN. Report Number: SYBH(E) EB. Reliability Laboratory of Huawei Technologies Co., Ltd.

DRAFT. Element Materials Technology. UltraTEV Plus2 FCC : MHz Radio. Report # ELEM NVLAP LAB CODE:

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

FCC Test Report. Report No.: AGC FE01 2AAP6UB15MSKB. Attestation of Global Compliance (Shenzhen) Co., Ltd

Verification Test Report

Application for FCC Certificate On Behalf of LG Electronics U.S.A., Inc. LCD Monitor. Model No.: E2242VA. Serial No.

Test Report. Product Name : IPC Model No.

Satec Ltd. 3-Phase Power Meter PM135

TEST REPORT. Table of Contents

TEST REPORT FROM RFI GLOBAL SERVICES LTD

F C C - TESTREPORT REPORT NO.: FCC-02/

Transcription:

Intel Corporation Corporate Product Regulations Ferrite Clamp/Tube Analysis CISPR/G/143/CDV 22 December 1999 Ghery S. Pettit, NCE Intel Corporation 2800 Center Drive DuPont, Washington 98327 (253) 371-5515

Table of Contents Section Page # I. Introduction...1 II. Test Program...1 III. Test Facility, Equipment and Process...1 IV. Test Results...4 System Emissions - No Ferrite Clamps on Power Cords...4 System Emissions - Ferrite Clamps on Power Cords...5 Intel DuPont Site EMC Lab - No Ferrites on Power Cords...6 Intel DuPont Site EMC Lab - Ferrites on Power Cords...7 Intel Oregon Site EMC Lab - No Ferrites on Power Cords...8 Intel Oregon Site EMC Lab - Ferrites on Power Cords...9 CKC Laboratories Tillamook EMC Lab - No Ferrites on Power Cords...10 CKC Laboratories Tillamook EMC Lab - Ferrites on Power Cords...11 Northwest EMC Lab - No Ferrites on Power Cords...12 Northwest EMC Lab - Ferrites on Power Cords...13 Acme Testing EMC Lab - No Ferrites on Power Cords...14 Acme Testing EMC Lab - Ferrites on Power Cords...15 V. Data Analysis...16 VI. Conclusions...20 VII. Recommendations...20 VIII. Acknowledgements...20 IX. Photographs...20 EUT Front View...21 Rear/Side View w/ Ferrite Clamps on Power Cords...22 Rear/Side View w/o Ferrite Clamps on Power Cords...23

I. Introduction CISPR/G/143/CDV proposes amending CISPR Publication 22, 3rd Edition, to include the use of ferrite clamps or tubes on all cables leaving the turntable when performing radiated emissions measurements. The stated purpose of this change is to improve repeatability between different test laboratories. II. Test Program The test program reported in this document was designed to provide a quick indication of the effectiveness of placing ferrite clamps or tubes on cables which leave the turntable on reducing measurement uncertainty between laboratories. One pair of tests was run at each of four laboratories. Each pair consisted of a test with and without ferrite clamps installed on the cables leaving the turntable. The test system investigated was an Intel NetPC with an NEC MultiSync C400 monitor, Keytronic keyboard and Logitech mouse. Other I/O ports on the computer were left unconnected. The ferrite clamps used were a Schaffner CDN 725 and a Schaffner INA 726. These ferrite clamps are part of the Intel DuPont Site EMC laboratory's IEC 61000-4-6 test system. III. Test Facility, Equipment and Process Testing was performed at the following EMC laboratories in the Pacific Northwest region of the United States: The Intel DuPont Site EMC Laboratory's 3 meter RF semi-anechoic chamber. This chamber is sized to allow full 1 to 4 meter height scans using broad band antennas and has a 2 meter diameter turntable. The chamber is listed with the FCC for class B certification testing of personal computer systems and peripherals. The Intel DuPont Site EMC Laboratory is accredited by A2LA and BSMI (Taiwan) and is approved by the New Zealand Ministry of Commerce, GOST, VCCI (PLC and OATS facilities only) and NEMKO (Test by Manufacturer program). This chamber was used to generate the list of frequencies to be measured at the Open Area Test Sites (OATS) for each of the laboratories. A Rohde & Schwarz ESBI receiver, Miteq preamplifier and Chase CBL-6112 BiLog antenna were used for the tests, operating under the control of Rohde & Schwarz ES-K1 software. The frequency range of 30 to 1000 MHz was scanned at 24 turntable positions (15 degree increments), at antenna heights of 100, 250 and 400 cm and at both horizontal and vertical polarities to find signals emitted by the EUT. 15 signals were then identified by the software based on user supplied criteria. These signals were re-measured at the worst case turntable position, antenna height and polarity (from the steps previously checked) to determine their precise frequency. Each signal was then fully maximized by rotating the turntable through a complete 360 degree circle and scanning the antenna from 1 to 4 meters at the worst case Page 1 of 23

polarity. Once the signal is maximized, a measurement is taken with the quasi-peak detector. This process was repeated with and without the ferrite clamps installed on each of the power cords (PC and monitor). The frequency lists from the two tests were merged into a single list which was used at each of the five OATS facilities for testing with and without ferrite clamps on the power cords. OATS Facilities: Intel DuPont Site EMC Laboratory, DuPont, Washington 10 meter OATS with a 57 by 67 foot ground plane, elevated about 1 foot above grade. The ground screen is 1/4 inch wire mesh, galvanized after weaving hardware cloth. The ground plane around the turntable area, extending beyond the fiberglass reinforced plastic dome is solid sheet metal, welded periodically at the joints. A Hewlett Packard 8546A receiver is used with an EMCO 3143 Biconilog antenna for measurements up to 1 GHz. Power to the EUT is provided via receptacles mounted to the concrete platform under the center of the turntable. These receptacles are fed from the control building via underground conduits. Intel Oregon Site EMC Laboratory, Hillsboro, Oregon 10 meter OATS with a 57 by 67 foot ground plane, elevated about 6 inches above grade on one side, with the grade sloping away, resulting in the ground plane being about 30 inches above grade on the other side. The ground screen is 1/4 inch wire mesh, galvanized after weaving hardware cloth. The ground plane around the turntable area, extending beyond the fiberglass reinforced plastic dome is solid sheet metal, welded periodically at the joints. A Hewlett Packard 8566B spectrum analyzer with a Hewlett Packard 85685A pre-selector and a Hewlett Packard 85650A quasi peak adapter is used with EMCO 3110B and 3146 antennas for measurements up to 1 GHz. Power to the EUT is provided via receptacles mounted to the concrete platform under the center of the turntable. These receptacles are fed from the control building via conduits routed under the ground plane platform. The Intel Oregon Site EMC Laboratory is accredited by A2LA, listed with the FCC (OATS and PLC test stands), registered with the VCCI, NEMKO TBM approved, approved by the New Zealand MOC, accredited by the BSMI and is GOST approved. Northwest EMC, Newberg, Oregon 10 meter OATS with a 24 by 66 foot ground plane, elevated about 12 inches above grade. The ground screen is 1/4 inch wire mesh, galvanized after weaving hardware cloth. A Hewlett Packard 8568B spectrum analyzer with a Hewlett 85650A quasi peak adapter is used with EMCO 3110B and 3146 antennas for measurements up to 1 GHz. Power to the EUT is provided Page 2 of 23

via an extension cord routed through the center of the turntable. This cord is fed from the control building via conduits routed under ground. Northwest EMC is accredited by NIST NVLAP, listed with the FCC, registered with the VCCI, NEMKO approved, approved by the New Zealand MOC, accredited by the BSMI and is GOST approved. CKC Laboratories, Tillamook, Oregon 30 meter OATS with a 34 by 145 foot ground plane, elevated about 42 inches above grade. The ground screen is 1/4 inch wire mesh, galvanized after weaving hardware cloth. Wire mesh is extended from both sides of the ground plane down to grade at about a 60 degree angle to minimize refraction at the edges of the ground plane. A Hewlett Packard 8568B spectrum analyzer with a Hewlett Packard 85650A quasi peak adapter is used a Chase CBL 6111 antenna for measurements up to 1 GHz. Power to the EUT is provided via receptacles in a metal box on top of the turntable, near the center. These receptacles are fed from a circuit breaker panel mounted under the ground plane. CKC Laboratories is accredited by A2LA, listed with the FCC, registered with the VCCI, NEMKO approved, approved by the New Zealand MOC, accredited by Austel and DAR. Acme Testing, Acme, Washington 30 meter OATS with a 20 by 50 meter ground plane, at grade. The ground screen is 1/4 inch wire mesh, galvanized after weaving hardware cloth. The ground plane around the turntable area is solid sheet metal, welded periodically at the joints. A Hewlett Packard 8567A spectrum analyzer with a Hewlett Packard 85685A pre-selector and a Hewlett Packard 85650A quasi peak adapter and LN1000A preamplifier is used with EMCO 3110B and 3146 antennas for measurements up to 1 GHz. Power to the EUT is provided via receptacles mounted in the face of the turntable. Acme Testing is accredited by A2LA and listed with the FCC. Page 3 of 23

IV. Test Results The following graphs show the emissions from the system, with and without ferrite clamps, as measured in the Intel DuPont EMC Laboratory 3 meter RF semi-anechoic chamber. These tests were performed on December 10 to develop the list of frequencies measured at the various OATS facilities. The red Xs show the level and frequency of the final quasi-peak measurements for the top 15 signals for the test. These two lists of 15 frequencies were merged to create the list of 18 frequencies measured at each OATS facility. Level [dbµv/m] 60 50 x 40 x x xx x x x x x x x x 30 x 20 10 30M40M50M 70M 100M 200M 300M400M 600M 1G Frequency [Hz] x xmes 971911i_fin QP MES 971911i_pre PK LIM EN55022 10m/3m xtrpl System Emissions - No Ferrite Clamps on Power Cords Page 4 of 23

Level [dbµv/m] 60 50 40 x x x x x x xx x x x x 30 x x 20 10 30M40M50M 70M 100M 200M 300M400M 600M 1G Frequency [Hz] x xmes 971911h_fin QP MES 971911h_pre PK LIM EN55022 10m/3m xtrpl System Emissions - Ferrite Clamps on Power Cords Page 5 of 23

The following results were obtained during testing on December 14, 1999 at the Intel DuPont Site EMC Laboratory 10 meter OATS. Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 28.1 14.3 30-1.9 398 202 Vert 41.90 18.6 10.0 30-11.4 119 110 Vert 47.70 19.4 8.5 30-10.6 117 162 Vert 133.50 36.1 10.0 30 6.1 117 141 Vert 141.35 30.6 11.3 30 0.6 117 200 Vert 186.15 25.2 11.6 30-4.8 364 332 Horz 188.45 30.8 11.7 30 0.8 119 203 Vert 204.15 33.7 12.4 30 3.7 117 196 Vert 212.00 Ambient 30 219.85 32.7 13.0 30 2.7 119 309 Vert 227.70 31.7 13.3 30 1.7 271 217 Horz 243.40 33.9 13.7 37-3.1 281 226 Horz 259.10 35.7 14.3 37-1.3 281 64 Horz 267.00 36.5 14.7 37-0.5 301 223 Horz 274.80 35.2 15.1 37-1.8 218 209 Horz 282.65 40.8 15.41 37 3.8 228 211 Horz 290.70 17.8 15.7 37-19.2 216 220 Horz 298.40 38.2 16.0 37 1.2 218 211 Horz Intel DuPont Site EMC Lab - No Ferrites on Power Cords Page 6 of 23

Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 23.1 14.3 30-6.9 115 107 Vert 41.90 19.1 10.0 30-10.9 117 344 Vert 47.70 17.3 8.5 30-12.7 118 28 Vert 133.50 36.4 10.0 30 6.4 117 130 Vert 141.35 30.6 11.3 30 0.6 117 215 Vert 186.15 22.3 11.6 30-7.7 118 66 Vert 188.45 30.6 11.7 30 0.6 117 253 Vert 204.15 32.1 12.4 30 2.1 117 189 Vert 212.00 Ambient 30 219.85 33.8 13.0 30 3.8 117 298 Vert 227.70 31.5 13.3 30 1.5 332 195 Horz 243.40 32.2 13.7 37-4.8 364 209 Horz 259.10 33.0 14.3 37-4.0 323 209 Horz 267.00 37.0 14.7 37 0.0 280 211 Horz 274.80 34.8 15.1 37-2.2 260 194 Horz 282.65 40.5 15.4 37 3.5 239 217 Horz 290.70 20.8 15.7 37-16.2 333 203 Horz 298.40 38.4 16.0 37 1.4 208 209 Horz Intel DuPont Site EMC Lab - Ferrites on Power Cords Page 7 of 23

The following results were obtained during testing on December 16, 1999 at the Intel Oregon Site EMC Laboratory. Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 31.2 14.2 30 1.2 V 41.90 Ambient 30 47.70 26.1 10.9 30-3.9 V 133.50 39.9 13.3 30 9.9 V 141.35 32.8 13.4 30 2.8 V 186.15 24.2 15.5 30-5.8 H 188.45 32.1 15.6 30 2.1 V 204.15 33.8 12.4 30 3.8 V 212.00 29.7 12.2 30-0.3 V 219.85 33.2 12.0 30 3.2 V 227.70 33.1 12.2 30 3.1 V 243.40 33.3 12.7 37-3.7 V 259.10 33.8 13.8 37-3.2 H 267.00 38.1 14.0 37 1.1 H 274.80 37.1 14.4 37 0.1 H 282.65 43.4 14.9 37 6.4 H 290.70 34.7 15.2 37-2.3 H 298.40 39.8 15.7 37 2.8 H Intel Oregon Site EMC Lab - No Ferrites on Power Cords Page 8 of 23

Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 24.1 14.2 30-5.9 V 41.90 30 47.70 21.1 10.9 30-8.9 V 133.50 34.8 13.3 30 4.8 V 141.35 32.7 13.4 30 2.7 V 186.15 24.2 15.5 30-5.8 H 188.45 30.8 15.6 30 0.8 V 204.15 33.4 12.4 30 3.4 V 212.00 29.9 14.2 30-0.1 V 219.85 33.7 12.0 30 3.7 V 227.70 33.0 12.2 30 3.0 V 243.40 34.0 12.7 37-3.0 V 259.10 35.9 13.8 37-1.1 V 267.00 37.3 14.0 37 0.3 H 274.80 36.2 14.4 37-0.8 H 282.65 39.8 14.9 37 2.8 H 290.70 33.7 15.2 37-3.3 H 298.40 39.4 15.7 37 2.4 H Intel Oregon Site EMC Lab - Ferrites on Power Cords Page 9 of 23

The following results were obtained during testing on December 17, 1999 at the CKC Laboratories Tillamook EMC Laboratory. Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 24.1-6.8 30-5.9 V 41.90 15.2-13.3 30-14.8 V 47.70 19.9-16.6 30-10.1 V 133.50 36.4-12.9 30 6.4 V 141.35 28.8-13.0 30-1.2 V 186.15 20.4-14.0 30-9.6 V 188.45 29.3-14.6 30-0.7 H 204.15 29.5-14.0 30-0.5 V 212.00 23.6-13.4 30-6.4 V 219.85 30.1-12.6 30 0.1 H 227.70 29.2-12.0 30-0.8 H 243.40 33.4-10.6 37-3.6 H 259.10 34.1-10.0 37-2.9 H 267.00 34.0-9.9 37-3.0 H 274.80 39.0-9.7 37 2.0 H 282.65 33.4-9.4 37-3.6 H 290.70 35.4-9.3 37-1.6 V 298.40 36.0-9.2 37-1.0 H CKC Laboratories Tillamook EMC Lab - No Ferrites on Power Cords Page 10 of 23

Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 22.7-6.8 30-7.3 V 41.90 13.6-13.1 30-16.4 V 47.70 11.5-16.2 30-18.5 V 133.50 34.1-12.9 30 4.1 V 141.35 28.3-12.9 30-1.7 V 186.15 25.3-14.8 30-4.7 H 188.45 28.1-14.6 30-1.9 H 204.15 28.2-14.0 30-1.8 V 212.00 23.8-13.4 30-6.2 V 219.85 31.6-12.6 30 1.6 V 227.70 29.8-12.0 30-0.2 H 243.40 34.3-10.6 37-2.7 H 259.10 35.9-10.0 37-1.1 H 267.00 32.5-9.9 37-4.5 H 274.80 37.8-9.7 37 0.8 H 282.65 34.7-9.4 37-2.3 H 290.70 36.3-9.3 37-0.7 H 298.40 36.7-9.2 37-0.3 H CKC Laboratories Tillamook EMC Lab - Ferrites on Power Cords Page 11 of 23

The following results were obtained during testing on December 20, 1999 at the Northwest EMC Laboratory. Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 Ambient 30 41.90 Ambient 30 47.70 Ambient 30 133.50 37.2-16.3 30 7.2 1.0 267 V 141.35 31.3-16.5 30 1.3 1.8 289 V 186.15 Ambient 30 188.45 32.6-11.6 30 2.6 1.5 267 V 204.15 34.7-17.3 30 4.7 1.0 241 V 212.00 30.4-17.4 30 0.4 4.0 66 H 219.85 32.8-17.6 30 2.8 1.0 239 V 227.70 33.5-17.6 30 3.5 3.4 211 V 243.40 34.6-16.6 37-2.4 3.0 228 H 259.10 31.3-15.9 37-5.7 4.0 159 V 267.00 37.9-15.5 37 0.9 2.8 253 H 274.80 34.6-15.1 37-2.4 3.0 111 H 282.65 38.4-14.5 37 1.4 4.0 150 V 290.70 28.3-12.8 37-8.7 4.0 158 V 298.40 31.9-13.1 37-5.1 2.8 193 H Northwest EMC Lab - No Ferrites on Power Cords Page 12 of 23

Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 Ambient 30 41.90 Ambient 30 47.70 Ambient 30 133.50 37.0-16.3 30 7.0 1.0 220 V 141.35 31.5-16.5 30 1.5 1.0 303 V 186.15 Ambient 30 188.45 33.4-11.6 30 3.4 1.0 244 V 204.15 34.3-17.3 30 4.3 1.0 227 V 212.00 29.7-17.4 30-0.3 1.0 308 V 219.85 33.7-17.6 30 3.7 1.0 250 V 227.70 32.4-17.6 30 2.4 4.0 215 H 243.40 33.9-16.6 37-3.1 3.0 24 H 259.10 30.6-15.9 37-6.4 1.0 274 V 267.00 36.9-15.5 37-0.1 3.0 300 H 274.80 33.3-15.1 37-3.7 3.0 195 H 282.65 39.6-14.5 37 2.6 3 207 H 290.70 28.0-14.2 37-9.0 3.6 202 H 298.40 33.3-13.1 37-3.7 2.7 202 H Northwest EMC Lab - Ferrites on Power Cords Page 13 of 23

The following results were obtained during testing on December 21, 1999 at the Acme Testing EMC Laboratory. Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 Ambient 30 41.90 14.6-17.1 30-15.4 155 V 47.70 20.6-19.4 30-9.4 125 V 133.50 34.7-16.0 30 4.7 105 V 141.35 20.7-15.7 30-9.3 175 V 186.15 21.3-14.1 30-8.7 90 V 188.45 28.9-13.9 30-1.1 245 V 204.15 30.8-19.0 30 0.8 140 V 212.00 26.5-19.4 30-3.5 85 V 219.85 31.7-19.9 30 1.7 200 V 227.70 32.4-20.2 30 2.4 145 V 243.40 31.3-20.0 37-5.7 150 V 259.10 29.5-19.1 37-7.5 160 V 267.00 34.0-18.5 37-3.0 160 V 274.80 28.7-17.8 37-8.3 350 H 282.65 35.3-17.3 37-1.7 140 H 290.70 27.1-16.7 37-9.9 140 H 298.50 32.5-16.2 37-4.5 120 H Acme Testing EMC Lab - No Ferrites on Power Cords Page 14 of 23

Frequency Level Transd Limit Margin Height Azimuth Pol MHz dbµv/m db dbµv/m db cm deg 30.95 Ambient 30 41.90 14.5-17.1 30-15.5 210 V 47.70 13.6-19.4 30-16.4 210 V 133.50 34.7-16.0 30 4.7 210 V 141.35 19.8-15.7 30-10.2 190 V 186.15 22.5-14.1 30-7.5 95 V 188.45 28.5-13.9 30-1.5 250 V 204.15 30.1-19.0 30 0.1 140 V 212.00 27.1-19.4 30-2.9 85 V 219.85 30.8-19.9 30 0.8 190 V 227.70 30.9-20.2 30 0.9 150 V 243.40 30.8-20.0 37-6.2 160 V 259.10 29.1-19.1 37-7.9 165 V 267.00 33.6-18.5 37-3.4 155 V 274.80 29.3-17.8 37-7.7 170 V 282.65 34.9-17.3 37-2.1 185 V 290.70 28.2-16.7 37-8.8 155 V 298.40 33.8-16.2 37-3.2 100 V Acme Testing EMC Lab - Ferrites on Power Cords Page 15 of 23

V. Data Analysis The first table shows the impact of adding the ferrite clamps to the power cords at each of the laboratories by frequency. As can be seen, most signals from the system assembled for this test are minimally impacted by the addition of ferrite clamps to the power cords. The major impact is to the broad band signals below 50 MHz. Change by adding ferrite Frequency Intel DP Intel OR CKC NW EMC Acme MHz 30.95-5.0-7.1-1.4 41.90 0.5-1.6-0.1 47.70-2.1-5.0-8.4-7.0 133.50 0.3-5.1-2.3-0.2 0.0 141.35 0.0-0.1-0.5 0.2-0.9 186.15-3.0 0.0 4.9 1.2 188.45-0.2-1.3-1.2 0.8-0.4 204.15-1.7-0.4-1.3-0.4-0.7 212.00 0.2 0.2-0.7 0.6 219.85 1.1 0.5 1.5 0.9-0.9 227.70-0.2-0.1 0.6-1.1-1.5 243.40-1.7 0.7 0.9-0.7-0.5 259.10-2.7 2.1 1.8-0.7-0.4 267.00 0.5-0.8-1.5-1.0-0.4 274.80-0.4-0.9-1.2-1.3 0.6 282.65-0.3-3.6 1.3 1.2-0.4 290.70 3.0-1.0 0.9-0.3 1.1 298.40 0.1-0.4 0.7 1.4 1.3 Page 16 of 23

Without ferrite clamps installed on the power cords, the following margin to the CISPR 22 Class B limit information was obtained. With a few exceptions, agreement between the laboratories was very good for these emissions from the test sample. The widest spread is generally at frequencies below 50 MHz where this EUT had broad band emissions which changed radically when ferrite clamps were added to the power cords. Statistics w/o Ferrites Frequency Max Min Mean St. Dev. MHz Margin Margin Margin Margin 30.95-5.9 1.2-2.2 3.6 41.90-15.4-11.4-13.9 2.2 47.70-10.6-3.9-8.5 3.1 133.50 4.7 9.9 6.9 1.9 141.35-9.3 2.8-1.2 4.8 186.15-9.6-4.8-7.2 2.3 188.45-1.1 2.6 0.7 1.6 204.15-0.5 4.7 2.5 2.2 212.00-6.4 0.4-2.5 3.1 219.85 0.1 3.2 2.1 1.2 227.70-0.8 3.5 2.0 1.7 243.40 1.3 4.6 3.3 1.2 259.10-0.5 5.7 2.9 2.5 267.00 4.0 8.1 6.1 2.0 274.80-1.3 9.0 4.9 3.9 282.65 3.4 13.4 8.3 4.0 290.70-12.2 5.4-1.3 7.1 298.40 1.9 9.8 5.7 3.5 Page 17 of 23

As was noted with no ferrite clamps, agreement between the 5 laboratories is fairly good for this test sample. 141.35 MHz has a larger standard deviation and total spread due to readings at one laboratory. Likewise, the high spread and standard deviation at 290.70 MHz is due to one laboratory (a different one than at 141.35 MHz). Statistics w/ Ferrites Frequency Max Min Mean St. Dev. MHz Margin Margin Margin Margin 30.95-7.3-5.9-6.7 0.7 41.90-16.4-10.9-14.3 3.0 47.70-18.5-8.9-14.1 4.2 133.50 4.1 7.0 5.4 1.2 141.35-10.2 2.7-1.4 5.2 186.15-7.7-4.7-6.4 1.4 188.45-1.9 3.4 0.3 2.1 204.15-1.8 4.3 1.6 2.5 212.00-6.2-0.1-2.4 2.9 219.85 0.8 3.8 2.7 1.4 227.70-0.2 3.0 1.5 1.3 243.40 0.8 4.3 3.0 1.5 259.10-0.9 5.9 2.9 3.1 267.00 2.5 7.3 5.5 2.2 274.80-0.7 7.8 4.3 3.2 282.65 4.7 10.5 7.9 2.8 290.70-9.2 6.3-0.6 6.0 298.40 3.3 9.4 6.3 2.7 Page 18 of 23

This table shows the impact of adding ferrite clamps to the power cords in terms of mean margins and standard deviations between labs. With the exception of the broad band signals below 50 MHz, very little change is noted by adding the ferrite clamps to the power cords. Mean and Standard Deviation w/ and w/o Ferrites Frequency Mean Margin Mean Margin Difference Margin Margin Difference MHz w/o Ferrite w/ Ferrite db St. Dev. St. Dev. db db db w/o Ferrite w/ Ferrite db db 30.95-2.2-6.7-4.5 3.6 0.7-2.8 41.90-13.9-14.3-0.4 2.2 3.0 0.8 47.70-8.5-14.1-5.6 3.1 4.2 1.1 133.50 6.9 5.4-1.5 1.9 1.2-0.7 141.35-1.2-1.4-0.3 4.8 5.2 0.4 186.15-7.2-6.4 0.8 2.3 1.4-0.9 188.45 0.7 0.3-0.5 1.6 2.1 0.5 204.15 2.5 1.6-0.9 2.2 2.5 0.2 212.00-2.5-2.4 0.1 3.1 2.9-0.3 219.85 2.1 2.7 0.6 1.2 1.4 0.2 227.70 2.0 1.5-0.5 1.7 1.3-0.4 243.40 3.3 3.0-0.3 1.2 1.5 0.3 259.10 2.9 2.9 0.0 2.5 3.1 0.6 267.00 6.1 5.5-0.6 2.0 2.2 0.2 274.80 4.9 4.3-0.6 3.9 3.2-0.6 282.65 8.3 7.9-0.4 4.0 2.8-1.2 290.70-1.3-0.6 0.7 7.1 6.0-1.1 298.40 5.7 6.3 0.6 3.5 2.7-0.8 Page 19 of 23

VI. Conclusions The results show that the ferrite clamps used in the tests (Schaffner CDN 725 EM Clamp and Schaffner INA 726 Isolation Clamp) do have significant impacts on the measured radiated emissions levels. The results show that the addition of ferrite clamps to power cords does not significantly reduce the measurement variation between the 5 laboratories with the single system tested for most of the emissions measured from the system. Broad band emissions below 50 MHz which are most heavily impacted by the addition of the ferrite clamps to the power cords are the only ones which appeared to benefit to any degree. The greatest reduction in standard deviation between having ferrite clamps on the power cords and not having ferrite clamps on the power cords was 2.8 db. Some standard deviations increased. The vast majority changed by less than 1.0 db. This proposal would create a large gap between CISPR 22 and ANSI C63.4 and negate 15 years of efforts to harmonize the test methods in the two standards. The data in this report does not provide a compelling argument to support the creation of this gap. VII. Recommendations The results of this study do not support the proposal in CISPR/G/143/CDV. Further experimentation is required with a number of different system configurations with power and I/O cables leaving the turntable to better evaluate this proposal. With the limited data contained in this report the proposal contained in CISPR/G/143/CDV cannot be supported, nor can it be definitively rejected. Unless and until compelling data can be gathered which shows the benefits of this proposal, the U.S. should cast a NO vote on the resulting FDIS. VIII. Acknowledgements The author would like to thank the staff and management of the following laboratories for their prompt scheduling of time for these tests: Intel Corporation DuPont Site EMC Laboratory, DuPont, Washington Intel Corporation Oregon Site EMC Laboratory, Hillsboro, Oregon CKC Laboratories, Tillamook, Oregon Northwest EMC, Newberg, Oregon Acme Testing, Acme, Washington IX. Photographs The following photographs show the system, with and without the ferrite clamps. Page 20 of 23

. EUT Front View Page 21 of 23

Rear/Side View w/ Ferrite Clamps on Power Cords Page 22 of 23

Rear/Side View w/o Ferrite Clamps on Power Cords Page 23 of 23