FSEC APPROVAL # XL15-NT

Similar documents
60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

SOLAR PV MICROINVERTER/ACM STANDARD PLAN - COMPREHENSIVE Microinverter and ACM Systems for One- and Two- Family Dwellings

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

CP /240-MC4 User Manual

Upsolar Smart Modules

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

HD WAVE INVERTERS. (+34) Skype

Your Origin SLIVER system will be supplied with one of the following sets of panels:

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

Installation/User Manual

Supplemental Calculation Sheets for Inverter #2

APPENDIX V PRODUCT SHEETS

Application Note: String sizing Conext CL Series

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Quality criteria and certificates

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Installation requirements

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Photovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved.

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual

Tel: Fax:

Zelio Control Measurement Relays

RESIDENTIAL SOLAR ROOF TOP EXPEDITED PERMITTING GUIDELINE. 10 KW OR LESS

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

Power Supplies 3. SDN-C Compact DIN Rail Series

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

DC PV Arc fault detection Unit

New Tools for PV Array Commissioning and Troubleshooting

Planning and Building Services Solar PV Standard Plan Simplified Central/String Inverter Systems (One- and Two-Family Dwellings)

Sunny Smile with Hyundai

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only*

INTELLIMETER REGISTER

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Test Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China

ABB central inverters PVI-55.0/ PVI-165.0/ PVI-275.0/ to 330 kw

Solmetric PVA-600 PV Analyzer

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

Type CP-S, CP-C & CP-A Switch mode

Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable

Array. Source-circuit configuration is arguably the most

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS ULTRA CORE PLUS

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

MAJORSINE Power Inverter

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer

Certificate of Compliance

Code Red: Notable Changes in the 2011 NEC

Features PVI-55.0 PVI PVI-165.0/220.0 PVI-275.0/330.0 GENERAL SPECIFICATIONS CENTRALIZED MODELS PLUS

Energy Management Service

Calculating AC Line Voltage Drop for S230 Microinverters with Engage Cables

System Components and Accessories

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

New Tools for PV Array Commissioning and Troubleshooting

VI 3 - i TABLE OF CONTENTS

Gutor PxW AC UPS Designed for North American Market

CONTINUING EDUC ATION

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

This document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB

Article 225: Outside Branch Circuits And Feeders

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

New Tools for PV Array Commissioning and Troubleshooting

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

Grounding Recommendations for On Site Power Systems

Power Processor - Series 700F 10KVA to 150KVA

MINI-PS AC/24DC/1.3

Short Circuit Current Calculations

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Switching Power Supply Type SPP1 60W Enclosed type

Test Report. File No.: SHV01032/18-02 Test Report No.:

HLC-1000 High-limit Humidity Control

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

C-Band Redundant LNA Systems

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

8V General information. 2 Order data 8V

StatiVolt. Inverter UPS Systems. Features. Contents

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

X-Band Redundant LNA Systems

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

Transcription:

AC GEC 4 IN SERIES TO UTILITY METER IN SERIES F-2 35A SW 60A SOLAR MODULE POWER BOX PM-25 270W 2 3 4 JUNCTION BOX 2 7 INVERTER I 6,000W 5 6 3 TO MAIN SERVICE ENTRANCE RE F. MODULES FSEC APPROVAL # XL5-NT90-02 REF. QTY. MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM-25 25 AXITEC AC-270M/56-60S 270W 244W 9.4A 8.80A 39.3V 30.9V -0.26V/ C (-0.32%/ C) 6A QT Y. MAKE AND MODEL I SOLAR EDGE SE6000A-US (240V) 240V INVERTERS AC VOLTAGE GROUND MAX OCPD RATING RATED MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY POWER FLOATIN 40A 6,000W 25A 8A 500V 97.5% G POWER OPTIMIZERS REF. QTY. MODEL RATED INPUT POWER MAX OUTPUT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY PO-25 25 SOLAR EDGE P300 300W 5A 0.0A 48V 98.8% DISCONNECTS REF. QTY. MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW SQUARE D D222NRB OR EQUIV. 60A 240VAC SYSTEM SUMMARY STRING # STRING #2 POWERBOX MAX OUTPUT CURRENT 5A 5A OPTIMIZERS IN SERIES 4 NOMINAL STRING VOLTAGE 350V 350V ARRAY OPERATING CURRENT 25A 25A ARRAY STC POWER 6,750W ARRAY PTC POWER 6,098W MAX AC CURRENT 25A MAX AC POWER 6,000W DERATED (CEC) AC POWER 5,874W I TYPICA D L 2 2 2 3 4 CONDUCTOR CONDUIT CURRENT-CARR YING CONDUCTORS IN CONDUIT 2 3 4 5 6 7 NOTES OCPDS REF. QTY. RATED CURRENT MAX VOLTAGE F-2 2 35A 240VAC THE OUTPUT VOLTAGE OF THE POWER OPTIMIZERS ARE REGULATED BY THE INVERTER. THEY ARE NOT IMPACTED BY THE NUMBER OF MODULES IN THE STRING. THE CONTINUOUS CURRENT OF A SINGLE STRING IS EQUAL TO THE MAXIMUM OUTPUT CURRENT OF THE OPTIMIZER. THE SOLAR EDGE INVERTER IS EQUIPPED WITH A RAPID SHUTDOWN FEATURE WHICH CONFORMS TO NEC 690.2 (204), WHICH REQUIRES THAT A RAPID SHUTDOWN FEATURE EXISTS TO DE-ENERGIZE PV SOURCE CIRCUITS FROM ALL SOURCES TO LESS THAN 30 VOLTS WITHIN 0 SECONDS. UNGROUNDED SYSTEM DC CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS. DC POSITIVE SHALL BE RED (OR MARKED RED) AND DC NEGATIVE SHALL BE BLACK (OR MARKED BLACK) DC VOLTAGE RANGE OF THE ARRAY IS REGULATED BY INVERTER AND WILL BE CONSTANT AT 350V. MAX DC VOLTAGE OF THE PV MODULE IS EXPECTED TO BE 42V AT 2 C (2 C - 25 C) X -0.26V/C + 39.26V = 42V). THE SOLAR EDGE INVERTER IS NON-ISOLATED. NEITHER THE NEGATIVE NOR POSITIVE CONDUCTOR IS GROUNDED AND THEREFORE NO DC GEC IS REQUIRED. INTEGRATED DC DISCONNECT IS PROVIDED WITH INVERTER. DISCONNECT IS LISTED FOR USE WITH SOLAR EDGE UL 74 LISTED STRING INVERTERS. OUTPUT OF INVERTER IS CONNECTED TO UTILITY ON LINE SIDE OF SERVICE DISCONNECT. CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS OCPD EGC 0 AWG PV 6 AWG BARE, FREE AIR N/A N/A WIRE, 0 AWG THWN-2, 0.5" DIA. 0 AWG THWN-2, 4 N/A FLEXIBLE STEEL 8 AWG THWN-2, 0 AWG THWN-2, 0.5" DIA. EMT 2 N/A 8 AWG THWN-2, 0 AWG THWN-2, 0.5" DIA. EMT 2 35A X 2 TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (25%) BASE AMP. DERATED TERM. TEMP. AMP. @ LENGT VOLTAGE AMP. RATING TERMINAL H DROP 0.7 (56 C) 0 5A 8.75A 55A 39.05A 75 C 50A 40FT 0.43% 0.76 (54 C) 0.8 5A 8.75A 40A 232A 60 C 30A 50FT 0.53% 0.96 (34 C) 0 25A 325A 55A 58A 60 C 40A 0FT 0.6% 0.96 (34 C) 0 25A 325A 55A 58A 75 C 50A 0FT 0.6% GROUNDING NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR 3 THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE 4 CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED 5 CONNECTIONS POINTS IDENTIFIED ON THE MODULE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) 6 SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF 7 #0AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 8 SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER PHENOLIC PLACARDS: APPLY TO RACEWAYS & JUNCTION BOX: WARNING PHTOVOLTAIC POWER SOURCE APPLY TO COLLECTION PANEL & AC DISCONNECT: WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.54 PERMANENT LABLE: APPLY TO AC DICONNECT & POINT OF INTERCONNECTION PHOTOVOLTAIC POWER SOURCE APPLY TO DC DISCONNECT: WARNING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED 25 240 AC OUTPUT CURRENT = AMP AC OPERATING VOLTAGE = VOLT PV- NEC 690.53 PERMANENT LABLE: APPLY TO INVERTER DC DISCONNECT: WARNING, DC SHOCK HAZARD () MAXIMUM POWERPOINT CURRENT, Impp = AMP (2) MAXIMUM POWERPOINT VOLTAGE, Vmpp = VOLT SINGLE-LINE DIAGRAM SCALE: NTS 8.8 350 500 5 (3) MAXIMUM SYSTEM VOLTAGE, Voc = VOLT (4) MAXIMUM CIRCUIT CURRENT, Isc = AMP THIS DOCUMENT HAS BEEN CREATED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PHOTOVOLTAIC POWER SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHOULD NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION MANUALS. INSTALLER SHALL INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURER INSTALLATION MANUALS. NOTHING IN THIS DOCUMENT SHOULD BE INTERPRETED IN A WAY THAT OVERRIDES THE INSTRUCTIONS IN MANUFACTURER INSTALLATION MANUALS.

NEC Code Compliance Report Maximum System Voltage Test Solar Edge inverter w/25 Axitec AC-270M/56-60S (270W)s Wire, Conduit, and OCPD Code Compliance Validation #: DC Circuit Circuit: Series String Output to Junction Box Array Properties Array Type Distributed MPPT System Inverter Array System Description Solar Edge inverter w/25 Axitec AC-270M/56-60S (270W)s Module AC-270M/56-60S (270W) Highest number of modules in series in a PV Source Circuit Design Low Temp. 2 C Module Voc 39.26V Temp. Coefficient Voc -0.26V/C A. Maximum Voltage of PV Source Circuit see Article 690.7(A) and Article 690.7(A) 46V NEC Article 690.7 requires that if the PV module manufacturer provides a temperature coefficient of open-circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE 'Extreme Annual Mean Minimum Design Dry Bulb Temperature' as the design low temperature. Using these values, the module Voc (39.26V) will increase to 46V at the design low temperature ( 2 C). (2 C - 25 C) X -0.26V/C + 39.26V = 46V The total Voc for the string is 46V. 46V X = 46V B. Maximum Voltage of DC Output Circuit see Article 690.7(C) 350V NEC Article 690.7(B) requires that all PV circuits have a voltage that does not exceed 600V. This system's DC Output Circuits are fed by Solar Edge P300 DC-to-DC converter optimization devices. Each device is connected to a single AC-270M/56-60S (270W) PV Module. The voltage of this circuit is regulated by the inverter at a constant 350V. PV Source Circuit maximum Voc must not exceed 600V 46V < 600V = true DC Output Circuit voltage must not exceed 600V 350V < 600V = true 0 AWG PV Wire, Copper Equipment Ground 6 AWG Bare, Copper OCPD(s) N/A Free Air Lowest Terminal Temperature 75 C Maximum Wire Temperature 56 C Power Source Description String of 4 Solar Edge P300 power optimizers, each connected to a AC-270M/56-60S (270W) PV module Power Source Rated Current 5A Power Source Rated Voltage 350V Module Series Fuse 6A Total Number of Series Strings 2 A. Continuous Current 5A The continuous current of this series string of power optimizers is equal to the rated maximum output current of the optimizer. Rated Max. Output Current of optimizer is 5A B. Base Ampacity 55A see Table 30.7 free air is 55A. C. Conditions of Use Ampacity 39.05A The temperature factor for 90 C insulation at 56 C is 0.7 The fill factor for conductors in free air is Ampacity (55A) multiplied by the temperature factor (0.7) and by the conduit fill factor (). 55A X 0.7 X = 39.05A System must meet requirements for not having series fuse (Article 690.8(B)(2)) This DC source circuit utilizes module-level power optimizers that provide internal current limitation as described in NEC article 690.8(B)(2). These devices have been certified to provide zero backfeed current to the PV source circuit, and zero backfeed current to the rest of the string. or equal to the Continuous Current (Article ) 39.05A >= 5A = true 55A > 8.75A = true 50A >= 5A X 25 = true 6 AWG >= 2 AWG = true EGC must meet NEC requirements for physical protection (Article 690.46) 6 AWG >= 6 AWG = true D. Ampacity at Terminal 50A The lowest terminal temperature rating for this segment is 75 C. The base ampacity of this conductor at 75 C is 50A. E. Minimum Required EGC Size 2 AWG see Table 250.22 and Article 690.45(A) The smallest EGC size allowed by Table 250.22 is 2 AWG. According to Article 690.45(A), it is not necessary to increase EGC when conductors are oversized for voltage drop considerations if the circuits are PV source circuits. DRAWN: SB CHECK: AG

#2: DC Source Circuit: Junction Box to Inverter #3: Inverter Output: Inverter to Utility Disconnect 0 AWG THWN-2, Copper Equipment Ground 0 AWG THWN-2, Copper OCPD(s) N/A 0.5" dia. Flexible Steel Lowest Terminal Temperature 60 C Maximum Wire Temperature 54 C Power Source Description String of 4 Solar Edge P300 power optimizers, each connected to a AC-270M/56-60S (270W) PV module Power Source Rated Current 5A Power Source Rated Voltage 350V Module Series Fuse 6A Total Number of Series Strings 2 A. Continuous Current 5A The continuous current of this series string of power optimizers is equal to the rated maximum output current of the optimizer. Rated Max. Output Current of optimizer is 5A B. Base Ampacity 40A see Table 30.6 conduit is 40A. C. Conditions of Use Ampacity 272A The temperature factor for 90 C insulation at 56 C is 0.7 The fill factor for a conduit that has 4 wires is 0.8. Ampacity (40A) multiplied by the temperature factor (0.7) and by the conduit fill factor (0.8). 40A X 0.7 X 0.8 = 272A D. Ampacity at Terminal 30A The lowest terminal temperature rating for this segment is 60 C. The base ampacity of this conductor at 60 C is 30A. E. Minimum Required EGC Size 2 AWG see Table 250.22 and Article 690.45(A) The smallest EGC size allowed by Table 250.22 is 2 AWG. According to Article 690.45(A), it is not necessary to increase EGC when conductors are oversized for voltage drop considerations if the circuits are PV source circuits. F. Minimum Recommended Conduit Size see Article 300.7 0.5" dia. The total area of all conductors is 0.266in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0. Qty Description Size Type Area Total Area 4 0 AWG THWN-2 0.02in² 0.0844in² 2 Equipment Ground 0 AWG THWN-2 0.02in² 0.0422in² 6 0.266in² 0.266in² / 0.4 = 0.365in² (Corresponding to a diameter of 0.5") System must meet requirements for not having series fuse (Article 690.8(B)(2)) This DC source circuit utilizes module-level power optimizers that provide internal current limitation as described in NEC article 690.8(B)(2). These devices have been certified to provide zero backfeed current to the PV source circuit, and zero backfeed current to the rest of the string. or equal to the Continuous Current (Article ) 272A >= 5A = true 40A > 8.75A = true 30A >= 5A X 25 = true 0 AWG >= 2 AWG = true Conduit must meet NEC recommendation for minimum size (Article 300.7) 0.5in. >= 0.5in. = true 8 AWG THWN-2, Copper Equipment Ground 0 AWG THWN-2, Copper OCPD(s) N/A 0.5" dia. EMT Lowest Terminal Temperature 60 C Maximum Wire Temperature 34 C Power Source Description Solar Edge SE6000A-US 6000W Inverter Power Source Rated Current 25A Power Source Rated Voltage 240V Inverter Max OCPD rating 40A A. Continuous Current 25A Equipment maximum rated output current is 25A B. Base Ampacity 55A see Table 30.6 conduit is 55A. C. Conditions of Use Ampacity 58A The temperature factor for 90 C insulation at 34 C is 0.9 The fill factor for a conduit that has 2 wires is Ampacity (55A) multiplied by the temperature factor (0.96) and by the conduit fill factor (). 55A X 0.96 X = 58A D. Ampacity at Terminal 40A The lowest terminal temperature rating for this segment is 60 C. The base ampacity of this conductor at 60 C is 40A. E. Minimum Allowed OCPD 3A see Article 23 NEC Code requires that the OCPD be rated for no less than 25 times the Continuous Current of the circuit. 25A X 25 = 325A rounded down to 3A F. Minimum Required EGC Size 0 AWG see Table 250.22 The smallest EGC size allowed by Table 250.22 is 0 AWG. G. Minimum Recommended Conduit Size see Article 300.7 0.5" dia. The total area of all conductors is 0.54in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0. Qty Description Size Type Area Total Area 2 8 AWG THWN-2 0.0366in² 0.0732in² Neutral 0 AWG THWN-2 0.02in² 0.02in² Equipment Ground 0 AWG THWN-2 0.02in² 0.02in² 4 0.54in² 0.54in² / 0.4 = 0.2885in² (Corresponding to a diameter of 0.5") 7. OCPD rating must be at least 25% of Continuous Current (Article 23) 35A >= 25A X 25 = true OCPD rating, or rating of next smaller OCPD (Article 240.3) 58A >= 35A (OCPD ) = true or equal to the Continuous Current (Article ) 58A >= 25A = true 55A > 325A = true 40A >= 25A X 25 = true 0 AWG >= 0 AWG = true Conduit must meet NEC recommendation for minimum size (Article 300.7) 0.5in. >= 0.5in. = true DRAWN: SB CHECK: AG

#4: Utility Disconnect Output: Utility Disconnect to Point of Connection 8 AWG THWN-2, Copper Equipment Ground 0 AWG THWN-2, Copper OCPD(s) 35A X 2 0.5" dia. EMT Lowest Terminal Temperature 75 C Maximum Wire Temperature 34 C Power Source Description Solar Edge SE6000A-US 6000W Inverter Power Source Rated Current 25A Power Source Rated Voltage 240V G. Minimum Recommended Conduit Size see Article 300.7 0.5" dia. The total area of all conductors is 0.54in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0. Qty Description Size Type Area Total Area 2 8 AWG THWN-2 0.0366in² 0.0732in² Neutral 0 AWG THWN-2 0.02in² 0.02in² Equipment Ground 0 AWG THWN-2 0.02in² 0.02in² 4 0.54in² 0.54in² / 0.4 = 0.2885in² (Corresponding to a diameter of 0.5") A. Continuous Current 25A Equipment maximum rated output current is 25A B. Base Ampacity 55A see Table 30.6 conduit is 55A. C. Conditions of Use Ampacity 58A The temperature factor for 90 C insulation at 34 C is 0.9 The fill factor for a conduit that has 2 wires is Ampacity (55A) multiplied by the temperature factor (0.96) and by the conduit fill factor (). 55A X 0.96 X = 58A D. Ampacity at Terminal 50A The lowest terminal temperature rating for this segment is 75 C. The base ampacity of this conductor at 75 C is 50A. E. Minimum Allowed OCPD 3A see Article 23 7. OCPD rating must be at least 25% of Continuous Current (Article 23) 35A >= 25A X 25 = true OCPD rating, or rating of next smaller OCPD (Article 240.3) 58A >= 35A (OCPD ) = true or equal to the Continuous Current (Article ) 58A >= 25A = true 55A > 325A = true 50A >= 25A X 25 = true 0 AWG >= 0 AWG = true Conduit must meet NEC recommendation for minimum size (Article 300.7) 0.5in. >= 0.5in. = true NEC Code requires that the OCPD be rated for no less than 25 times the Continuous Current of the circuit. 25A X 25 = 325A rounded down to 3A F. Minimum Required EGC Size 0 AWG see Table 250.22 The smallest EGC size allowed by Table 250.22 is 0 AWG. DRAWN: SB CHECK: AG

FSEC APPROVAL # XL5-NT90-02, MODEL AC-270M/56-60S AC-270M/56-60S AC-275M/56-60S AC-280M/56-60S AC-285M/56-60S AC-290M/56-60S AXIpremium Distributed by: AC-270M/56-60S AC-275M/56-60S AC-280M/56-60S AC-285M/56-60S AC-290M/56-60S AXIpremium 60 cell / monocrystalline photovoltaic modules High performance photovoltaic modules The advantages: 2 Years 2 years manufacturer s warranty 25 YEARS 85% Electrical data (at standard conditions (STC) irradiance 0 watt/m 2, spectrum AM 5 at a cell temperature of 25 C) Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion Pmpp Umpp Impp Isc Uoc efficiency AC-270M/56-60S 270 Wp 30,94 V 8,80 A 9,4 A 39,26 V 6,60 % AC-275M/56-60S 275 Wp 3,20 V 8,86 A 9,50 A 39,32 V 6,90 % AC-280M/56-60S 280 Wp 3,50 V 8,95 A 9,55 A 39,45 V 7,2 % AC-285M/56-60S 285 Wp 3,59 V 9,09 A 9,68 A 39,56 V 7,52 % AC-290M/56-60S 290 Wp 3,7 V 9,6 A 9,70 A 39,70 V 7,83 % A-Max Wp Highest performance due to specifically selected technologies and materials Guaranteed positive power tolerance from 0-5 Wp by individual measurement Design Frontside 3,2 mm hardened, low-reflection white glass Cells 60 monocrystalline high efficiency cells 56 mm x 56 mm (6 ) Backside Composite film Frame 35 mm silver anodized aluminium frame Limit values System voltage 0 VDC NOCT (nominal operating cell temperature)* 45 C +/-2K Max. load-carrying capacity 5400 N/m 2 Reverse current feed IR 6,0 A 400 Pa % Soft Grip warranted module performance IP 67 % 97% 90% 85% 80% Maximum 5400 Pa snow load % electroluminescence inspection High stability due to AXITEC-Soft-Grip-Seam aluminium frame construction High quality junction box and connector systems Exclusive linear AXITEC high performance guarantee! 5 years manufacturer s guarantee on 90 % of the nominal performance 25 years manufacturer s guarantee on 85 % of the nominal performance AXITEC Warranty Added Value! commercial level warranty 0% Years 5 0 5 20 25 85% 80% Fig. similar 60M56EN6025A Mechanical data L x W x H Weight 640 x 992 x 35 mm 8,0 kg with frame Power connection Socket Protection Class IP67 (3 bypass diodes) Wire approx., m, 4 mm 2 Plug-in system Plug/socket IP67 M2 360 M 860 8-(Ø 6,5 x 0) mounting holes 2 x Ø 6,5 grounding holes 954 35 All dimensions in mm Permissible operating temperature (No external voltages greater than Uoc may be applied to the module) * NOCT, irradiance 800 W/m 2 ; AM,5; wind speed m/s; Temperature 20 C Temperature coefficients Voltage Uoc Current Isc Output Pmpp -40 C to 85 C / -40F to 85F -0,30 %/K 0,04 %/K -0,40 %/K Low-light performance (Example for AC-260M/56-60S) I-U characteristic curve Current Ipp Voltage Upp 200 W/m 2,7 A 30,00 V 400 W/m 2 3,4 A 30,0 V 600 W/m 2 5,8 A 30,8 V 800 W/m 2 6,89 A 30,36 V 0 W/m 2 8,60 A 30,42 V Packaging Module pieces per pallet 30 Module pieces per HC-container 840 Technical data are subject to change without prior notice, errors excepted. The measurement tolerances are +/-3%

SolarEdge Power Optimizer Module Add-On For North America P300 / P400 / P405 PV power optimization at the module-level Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety POWER OPTIMIZER (2) It is not allowed to mix P405 with P300/P400/P600/P700 in one string. P300 (for 60-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power () 300 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 80 25 Vdc MPPT Operating Range 8-48 8-80 5-05 Vdc Maximum Short Circuit Current (Isc) 0 Adc Maximum DC Input Current 5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 5 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer Vdc STANDARD COMPLIANCE EMC FCC Part5 Class B, IEC60-6-2, IEC60-6-3 Safety IEC6209- (class II safety), UL74 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 0 Vdc Pxxx-2 series 4 x 22 x 40.5 / 55 x 8.34 x 59 mm / in Dimensions (W x L x H) 28 x 52 x 27.5 / 28 x 52 x 35 / 28 x 52 x 48 / Pxxx-5 series 5 x 97 x 08 5 x 97 x 37 5 x 97 x 89 mm / in Weight (including cables) Pxxx-2 series 950 / gr / lb Pxxx-5 series 770 / 7 930 / 05 930 / 05 gr / lb Input Connector MC4 Compatible Output Wire Type / Connector Double Insulated; MC4 Compatible Output Wire Length 0.95 / 0 2 / 9 m / ft Operating Temperature Range -40 - +85 / -40 - +85 C / F Protection Pxxx-2 series IP65 / NEMA4 Pxxx-5 series IP68 / NEMA6P Relative Humidity 0 - % () Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER (2) SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optimizers) 8 0 8 Maximum String Length (Power Optimizers) 25 25 50 Maximum Power per String 5250 6000 2750 W Parallel Strings of Different Lengths or Orientations Yes www.solaredge.us SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 2/204 V.0 Subject to change without notice.

SolarEdge Single Phase Inverters For North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE00A-US / SE400A-US 2-25 The best choice for SolarEdge enabled systems Integrated arc fault protection for NEC 20 690. compliance Rapid shutdown for NEC 204 690.2 Superior efficiency (98%) Small, lightweight and easy to install on provided bracket Built-in module-level monitoring Internet connection through Ethernet or Wireless Outdoor and indoor installation Fixed voltage inverter, DC/AC conversion only Pre-assembled Safety Switch for faster installation Optional revenue grade data, ANSI C INVERTERS Single Phase Inverters for North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A-US / SE00A-US / SE400A-US SE3000A-US SE3800A-US SE5000A-US SE6000A-US SE7600A-US SE00A- US SE400A-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 00 @240V 400 VA Max. AC Power Output 3300 450 5400 @ 208V 0800 @ 208V 6000 8350 5450 @240V 0950 @240V 2000 VA AC Output Voltage Min.-Nom.-Max. () 83-208 - 229 Vac - - 3 - - 3 - AC Output Voltage Min.-Nom.-Max. () 2-240 - 264 Vac 3 3 3 3 3 3 3 AC Frequency Min.-Nom.-Max. () 59.3-60 - 60.5 Hz Max. Continuous Output Current 5 6 24 @ 208V 48 @ 208V 25 32 2 @ 240V 42 @ 240V 47.5 A GFDI Threshold A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Yes INPUT Maximum DC Power (STC) 4050 5 6750 8 0250 3500 5350 W Transformer-less, Ungrounded Yes Max. Input Voltage 500 Vdc Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Vdc Max. Input Current (2) 9.5 3 5 @ 208V 33 @ 208V 8 23 5 @ 240V 30.5 @ 240V 35 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 % CEC Weighted Efficiency 97.5 98 97 @ 208V 97 @ 208V 97.5 97.5 98 @ 240V 97.5 @ 240V 97.5 % Nighttime Power Consumption < 5 < 4 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, RS232, Ethernet, ZigBee (optional) Revenue Grade Data, ANSI C Optional (3) Rapid Shutdown NEC 204 690.2 Yes STANDARD COMPLIANCE Safety UL74, UL699B, UL998, CSA 22 Grid Connection Standards IEEE547 Emissions FCC part5 class B INSTALLATION SPECIFICATIONS AC output conduit size / AWG range 3/4 minimum / 6-6 AWG 3/4 minimum / 8-3 AWG DC input conduit size / # of strings / 3/4 minimum / -3 strings / 3/4 minimum / -2 strings / 6-6 AWG AWG range 4-6 AWG Dimensions with Safety Switch 30.5 x 5 x 0.5 / in / 30.5 x 5 x 7.2 / 775 x 35 x 84 (HxWxD) 775 x 35 x 260 mm Weight with Safety Switch 52 / 22 57 / 27 88.4 / 40. lb / kg Cooling Natural Convection Natural convection and internal fan (user replaceable) Fans (user replaceable) Noise < 25 < 50 dba Min.-Max. Operating Temperature Range -3 to +40 / -25 to +60 (-40 to +60 version available (4) ) F / C Protection NEMA 3R () For other regional settings please contact SolarEdge support. (2) A higher current source may be used; the inverter will limit its input current to the values stated. (3) Revenue grade inverter P/N: SExxxxA-US000NNR2 (for 7600W inverter:se7600a-us002nnr2). (4) -40 version P/N: SExxxxA-US000NNU4 (for 7600W inverter:se7600a-us002nnu4). www.solaredge.us SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 0/20 V.0 Subject to change without notice.