AC 1000 Single-Slot T1 Mini Repeater Apparatus Case

Similar documents
High-Speed Voice and Data Link Repeater

Wire Transmission Only with Sealing Current (4W TO W/SC) Channel Unit

kbps Asynchronous Data Channel Unit

W FXS LS/GS Channel Unit 600 Ohms

Data Channel Interface W/SC Generator

Wire Foreign Exchange Office with Loop to E&M Conversion (2W FXO LP/E&M) Channel Unit

Wire Line Amplifier

Figure FXS Front Panel. Figure FXS Front Panel

/04 2-Wire Foreign Exchange Office (2W FXO) Channel Units

Wire Loop Signaling Repeater, Loop Start Only

Wire Duplex (2W DX) Channel Unit

OnSite 19 /15U Wall Rack Model WR-15U

OnSite 19 /15U Wall Rack Model WR-15U

Screw Hole. Figure 1 TOOLING ASSISTANCE CENTER PRODUCT INFORMATION

Balishutters. INSTALLATION guide FOR L-FRAME MOUNT INSTALL OPTIONS B OR C

W Universal SF (USF) Channel Unit

compile system INSTALLATION GUIDE Updated January 2019

CFC Series Cable Replacement Kit. for CFP Series Carbon Fiber Boom Poles. Owner s Manual

Round or Square Chicago Plenum Down Light Housing with Lamp

PORTROD WALL MOUNTED HEIGHT ROD

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

S E L E C T I O N. Arm Curl. User manual

MPA-9000 Universal Ceiling Projector Mount Kit

GB-AVSTOR5 Ceiling Equipment Storage Box with Pipe Coupler

Hand Crimp Tool Operating Instruction And Specifications Sheet Order No Eng. No. RHT 7050 (Replaces )

Application Tooling Specification Sheet

PHTM200 - Phantom 200 Flat Screen Wall Mount with Wafer Thin Projection Fits Screens up to 50 lbs with 200mm Mounting Patterns

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

Application Tooling Specification Sheet

PERSONAL RECORD KEEPING

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

Application Tooling Specification

Application Tooling Specification

WVC100E WVC100 INSTALLATION & OPERATION GUIDE. Weatherproof Stereo Volume Controls

Application Tooling Specification

Door window. Front door window, assembly overview

Order Number

LCD LIFT Flat Panel Display System Installation Manual. Table of Contents

Panel Grille Suspended Ceiling Installation Guide

FP-4855 Flat Panel Television Stand ASSEMBLY INSTRUCTIONS

Application Tooling Specification Sheet

Cluster Block Housings and Contacts

Order Number

INSTALLATION & OPERATION GUIDE. SVC100R High-Power Sliding Volume Control

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

PRO- CRIMPER* III Hand Crimping

VirtualEdge SwingRack Wall-mount 19/23" Equipment Rack (Model VESR-24)

NetShelter VX. Four-Post Open Frame. User s Manual

Hand Crimp Tool Operating Instruction and Specifications Sheet Part No Eng. No. RHT 5770 (Replaces and )

* * APPLICABLE MODELS: 2014 > MAZDA 3

Hand Crimp Tool Operating Instruction Sheet and Specifications Part No Eng. No. RHT 2749-CC (Replaces )

PERSONAL RECORD KEEPING

Models 2230 and 2240

Vinyl Sliding Glass Door Assembly Instructions

SELECTIVE CALL INTERCOM SYSTEM MODEL: IM-5000 MASTER STATION

AMPSEAL* Automotive Plug Connector and Header Assembly

NetShelter VS Enclosure. User s Manual

MaxLite Linear Strip ECO Series

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

INSTALLATION INSTRUCTIONS Small Flat Panel Mounts Model: F-Series

Application Tooling Specification Sheet

Application Tooling Specification

Signal Mirror Installation Instructions

INSTALLATION INSTRUCTIONS

Application Tooling Specification Sheet

S&C Scada-Mate Switching Systems Outdoor Distribution Interrupter Replacement 14.4 kv through 34.5 kv

1.0 Tool Components and Operation Instructions

Tilting Flat Panel Wall Mount Installation Guide

Please Do Not Return This Product To The Store!

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

3 Shielded Compact Ribbon (SCR) Wiremount Plug, XX, and Shell Kit, F200-XXX

Signal Mirror Installation Instructions Toyota Tacoma

Signal Mirror Installation Instructions Honda Odyssey

3M Locator Plate

Thank you for purchasing out product! *Please read these instructions and follow them step by step. *

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

Application Tooling Specification Sheet

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

Application Tooling Specification Sheet

SCOPE Perma-Seal Terminals and Splices AWG (Rings, Spades, Hooks, 3 and 4-Ways, and Splices). RHT-5770 Hand Crimp Tool

BX2173 Installation Instructions Ford Focus (including the 2.3L engine) 2003 Ford Focus SVT

STEP BY STEP INSTALLATION INSTRUCTIONS. Pleated Shades. Easy Lift Cordless

OPERATOR S MANUAL Model 58B Prefeed / Dereeler

Senior Swing. Caution

High Current Pin and Socket Contacts 31 JUL 13 Rev C

Wiring Techniques for Wiring a Lamp

Speaker Mount Center Channel Speaker Adapter (PAC-301)

Plug-n-Show Stake Down Pixel Tree Kit 16 strips of 25 pixels Assembly Instructions

Application Tooling Specification Sheet

LC200WT Security Wall Mount with Tilt for up to 32" Flat Screens

HAND CRIMP TOOL Specification Sheet Order No

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

N ETWOR KS FHX 8-PORT FIBER ENCLOSURE USER MANUAL

Assembly Instructions for model: VMPR1

600G2 Internal Sliding Adapter Panel Shelf Instructions

Agilent N2902A 9000 Series Oscilloscope Rack Mount Kit

Midmark Stainless Steel Cages Setup Manual

GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

Transcription:

Telecommunications Group Section AC1 000 00 Equipment Issue Fourth Printing, August 200 AC 1000 Single-Slot T1 Mini Repeater Apparatus Case CLEI Code: T1RCVUFRA CPR: 100 CONTENTS PAGE Part 1. GENERAL............................................................................. 2 Part 2. INSPECTION........................................................................... 2 Part. ESCRIPTION......................................................................... Part. MOUNTING............................................................................ Part. INSTALLER CONNECTIONS............................................................. Part. TECHNICAL ASSISTANCE.............................................................. 7 Part 7. WARRANTY & CUSTOMER SERVICE.................................................... 7 Part. SPECIFICATIONS & APPROVALS....................................................... Figure 1. AC 1000 Apparatus Case 200 Charles Industries Ltd. CLEI is a trademark of Bell Communications Research, Inc. All rights reserved. Printed in United States of America. The availability of features and technical specifications herein subject to change without notice. Page 1 of

1. GENERAL 1.1 ocument Purpose This document provides general and installation information for the Charles Industries AC 1000 Single-Slot T1 Apparatus Case, shown in Figure 1. 1.2 ocument Status This document is updated to change the termonology rubber grommets to grommets. Figure 2 and Figure have been updated to show the correct grommets. 1. Equipment Function The AC 1000 Apparatus Case provides mounting for one 2-type (unprotected), one 2-type (protected) T1 span line mini repeater, or one 270 SmartSpan repeater. (The 2-type repeater is recommended due to the secondary surge protection provided in these units. In all cases, building entrance primary protection MUST be provided per local practice.) The AC 1000 can be used to provision S1 service offerings where cable losses dictate the need for a regenerator at or near the customer s premises. The AC 1000 is used in lieu of larger apparatus housings and provides S1 service at a reduced cost. 1. Equipment Location/Mounting The AC 1000 Apparatus Case is designed for indoor mounting at or near the customer s premises, and is typically mounted on a wood backboard. 1. Equipment Features The AC 1000 case features the following: Light-weight all-aluminum case material Trim, stackable, piggy-back design saves wall space and provides snug fit for mini repeaters Interior card-edge connector for mini repeater Interior terminal block for input, output and fault locate connections Wiring diagram label for terminal screw functions on inside cover Top cap for repeater protection Two cable ties 2. INSPECTION 2.1 Inspect for amages Inspect the equipment thoroughly upon delivery. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company. 2.2 Equipment Identification Charles Industries equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment. Each time a major engineering design change is made on the equipment, the issue number is advanced by 1 and imprinted on subsequent units manufactured. Therefore, be sure to include both the model number and its issue number when making inquiries about the equipment. 2

. ESCRIPTION The aluminum AC 1000 Single-Slot T1 Apparatus Case consists of three basic parts: a case base, a snap-on case cover, and a top repeater-access cap, which, when removed, provides access to the mini repeater card slot..1 Repeater-Access Cap The snap-on repeater-access cap (item A, Figure 2) functions as a dust or environmental cover, and is designed to fit over the top opening of the case. A =Repeater access cap A C B C =Case cover =Case base =Mounting tabs () E B F E G G ÍÍ ÍÍ H E F G H I J L M N =Piggy-back stacking tabs & screws (2) =Wiring iagram Label =Repeater stability tabs =Mini repeater connector =Terminal block =Ground stud =Security screws & slots =Wire access slots (2) =Ground wire slot =Grommets N L M I J L Four Stacked Cases ÇÇ N.2 Case Base Figure 2. AC 1000 Apparatus Case The case base (item C, Figure 2) contains the following features: 12-pin female card-edge connector (item H, Figure 2), for terminating the plug-in mini repeater (repeater connector contacts are gold-plated) Screw-type terminal block (item I, Figure 2), for terminating wire pairs to the repeater, including input, output, and fault locate output connections for both side 1 and side 2 of the repeater (the AC 1000 is shipped/pre-wired with jumpered fault locate outputs 2 and 7 strapped to ground) Ground stud, conveniently located at bottom end by wire entrance to facilitate connection to an approved ground source Three slots at the bottom; one slot for ground cable access and two keyhole-type with grommets for line/wire access

Four mounting tabs (ears) Two slotted screws (one on each side), which mate with slots in the housing cover to provide security and protection of internal electronics.. Case Cover The case cover (item B, Figure 2) fits snugly over the case base, when the screw slots on the sides are properly aligned with the corresponding security screws on the sides of the case base. The front of the case cover is silkscreened with the company and equipment identification information, and on the inside of the cover is a wiring diagram label, as shown in Figure 2 and Figure. Also on the front are two piggy-back stacking tabs (item E Figure 2), one on each side, for securing apparatus cases together when multiple cases are stacked on top of each other. (To stack up to four cases together, see Mounting.) 1 GR 2 FLT. LOCATE SIE 1 TIP-OUT SIE 1 RING-OUT TIP-IN SIE 1 RING-IN 7 FLT. LOCATE SIE 2 TIP-OUT RING-OUT SIE 2 10 F.L. COMM-GR 11 TIP-IN 12 RING-IN SIE 2 NOTES: 1) REMOVE STRAPS FROM TERMINALS 2 & 7 WHEN FAULT LOCATE IS USE. 2) BIIRECTIONAL SHOWN. Figure. Interior View of Cover, Bottom Half. MOUNTING The AC 1000 is typically mounted on a wood backboard at the customer s location. Use the following steps to mount the case(s: Step Action 1. Locate the specified mounting location for the AC 1000 case or select a mounting location as close to the cable protector as possible. 2. Remove the case cap(s) and cover(s), but do not completely remove the side security screws (item, Figure 2).. Position the case base on the backboard and mark the four mounting hole locations.. Using four appropriate wood screws, secure the case base to the backboard at the marked locations. Note: epending on the type of wood backboard used, it may be necessary to provide a pilot hole for the wood screws.. If installing only one AC 1000 case, proceed to Part, Installer Connections.

Step Action. When installing more than one AC 1000 case in a stacked or piggy-back fashion (see Figure 2), first perform Steps 1 through 7 in Part for the bottom case before stacking the next case on top of it. Once the connections are made to the already-mounted bottom case and the cover is installed, remove the two piggy-back stacking screws (item F, Figure 2) from the bottom case cover. With the cover removed from the top or second case, place the top case base in front of the bottom case, carefully aligning the stacking tabs of the bottom case cover with the stacking tabs of the top case base. Secure the two together with the stacking tab screws just removed, one on each side. Then perform Steps 1 7 in Part for the top case. Repeat entire procedure for a third and fourth case, if desired. 7. After all units are mounted (Part ) and wired (Part ), the repeater-access cap(s) can be re-attached to the case(s). O NOT stack more than four () units. CAUTION Card Edge Connector 12 7 1 Installer Connection Terminal Strip Cable tie Ground Stud for cable shield ground connection Grommet OUTPUT Shielded single pair wire or shielded multi pair cable INPUT Figure. Interior View of Base, Bottom Half. INSTALLER CONNECTIONS Follow the steps below to make the installer connections to the AC 1000 Apparatus Case. Step Action 1. Access the Interior Screw Terminal Block If not already done, first slide off the top repeater access-cap and then remove the case cover. To remove the case cover, first loosen the two slotted screws (one on each side of the case) using a flatblade screwdriver, and then firmly lift off the case cover. 2. Prepare Wire Ends The terminal block accepts 1 through 2 AWG copper wire. Strip 1/2-inch of insulation from the wire ends to be connected.

Step Action. Route the Wires Route the stripped wires through the two / -inch holes (through the protective grommets) at the bottom of the case. (The middle slot directly below the ground stud is for the ground wire and does not require a grommet.). Connect Wires to Terminal Strip Make the appropriate connections per the wiring diagram shown in Figure. A quick-reference wiring diagram label is provided on the inside of the case cover. Note that the jumpered fault locate outputs at terminals 2 and 7 should always be strapped to ground, as shown in Figure, unless an external fault locate filter is specified.. Connect Ground Wire A ground stud at the bottom center of the case base is used for connecting the ground wire and the ground shield of the transmit and receive pairs. Alternately the shields can be tied to positions 1 and 10 on the terminal block, which are internally connected to ground. Note: The cable pair shields MUST only be grounded at one end. Note: Only one 1-gauge (minimum) earth ground wire is required for up to four stacked units.. Install Cable Ties After all wiring connections are complete, further secure the wires on each side with the two cable ties provided, as shown in Figure. 7. Close the Apparatus Case After the wiring connections have been made, re-attach the cover to the base by aligning the side security slots on the cover with the side security screws on the base and then pressing together until they snap closed. Firmly tighten the two security screws on the case cover, one on each side.. Insert Mini Repeater With the mini repeater s card edge close to the case base, slide the mini repeater into the apparatus case through the top slot opening, Firmly but gently push the mini repeater into the card-edge connector at the bottom of the case slot.. Install Repeater-Access Cap When wiring is complete and the mini repeater is installed, further protect the apparatus case by installing the snap-on, top repeater-access cap. CAUTION Install and remove repeater with care. o not force a repeater into place. If excessive resistance is encountered while installing, remove the repeater to check for proper alignment and an unobstructed insertion path and connector.

T1 REPEATER BIIRECTIONAL OPERATION NOTE 1 1 SIE 1 OUT SIE 2 OUT 1 F.L. SIE 1 2 1 SIE 1 IN F.L. SIE 2 F.L. COMMON 7 10 2 SIE 2 IN 11 12 1 2 7 10 11 12 2 7 10 11 12 11 12 SHIEL T R T R OUTPUT SIE 1 INPUT SIE 1 Case Ground (Installer ground connection) T R T R OUTPUT SIE 2 NOTE 2 INPUT SIE 2 NOTE 2 NOTE 1: Units are shipped with jumpered fault locate outputs 2 and 7 strapped to ground. Remove straps for external fault locate filter applications. NOTE 2: If unidirectional repeaters are used, the side 2 (only) regenerator inputs and outputs are reversed from that shown. The customer and office side connections are also reversed for side 2. Figure. Wiring iagram of AC 1000 Equipped with Bi-directional (two-way) Repeaters. TECHNICAL ASSISTANCE If technical assistance is required, contact Charles Industries Technical Services Center at: 7 0 00 7 0 (FAX) 00 07 00 techserv@charlesindustries.com (e-mail) 7. WARRANTY & CUSTOMER SERVICE 7.1 Warranty Charles Industries, Ltd. offers an industry-leading, -year warranty on products manufactured by Charles Industries. Contact your local Sales Representative at the address or telephone numbers below for warranty details. The warranty provisions are subject to change without notice. The terms and conditions applicable to any specific sale of product shall be defined in the resulting sales contract. Charles Industries, Ltd. 00 Apollo rive Rolling Meadows, Illinois 000 0 7 0 00 (Main Office) 7 0 21 (FAX) 7

7.2 Field Repairs (In-Warranty Units) Field repairs involving the replacement of components within a unit are not recommended and may void the warranty and compatibility with any applicable regulatory or agency requirements. If a unit needs repair, contact Charles Industries, Ltd. for replacement or repair instructions, or follow the Repair Service Procedure below. 7. Advanced Replacement Service (In-Warranty Units) Charles Industries, Ltd. offers an advanced replacement service if a replacement unit is required as soon as possible. With this service, the unit will be shipped in the fastest manner consistent with the urgency of the situation. In most cases, there are no charges for in-warranty repairs, except for the transportation charges of the unit and for a testing and handling charge for units returned with no trouble found. Upon receipt of the advanced replacement unit, return the out-of-service unit in the carton in which the replacement was shipped, using the preaddressed shipping label provided. Call your customer service representative at the telephone number above for more details. 7. Standard Repair and Replacement Service (Both In-Warranty and Out-Of-Warranty Units) Charles Industries, Ltd. offers a standard repair or exchange service for units either in- or out-of-warranty. With this service, units may be shipped to Charles Industries for either repair and quality testing or exchanged for a replacement unit, as determined by Charles Industries. Follow the Repair Service Procedure below to return units and to secure a repair or replacement. A handling charge applies for equipment returned with no trouble found. To obtain more details of this service and a schedule of prices, contact the CI Service Center at 217 2 2 (FAX 217 2 2). Repair Service Procedure 1. Prepare, complete, and enclose a purchase order in the box with the equipment to be returned. 2. Include the following information: Company name and address Contact name and phone number Inventory of equipment being shipped Particulars as to the nature of the failure Return shipping address. Ship the equipment, purchase order, and above-listed information, transportation prepaid, to the service center address shown below. CI Service Center 0 N.E. 1th St., P.O. Box Casey, IL 220 20. Most repaired or replaced units will be returned within 0 or days, depending on the product type and availability of repair parts. Repaired units are warranted for either 0 days from the date of repair or for the remaining unexpired portion of the original warranty, whichever is longer.. SPECIFICATIONS & APPROVALS.1 Regulatory/Agency Approvals The following regulatory agency approvals apply to the AC 1000. UL Listed under Underwriters Laboratories Standard 1, Second Edition. Compliance is restricted to inside plant wiring. Field repairs may void compliance..2 Electrical Specifications The electrical characteristics of the AC 1000 are as follows: Compatible with T1, T1C, T1, and T1G Carrier Systems.

. Physical Specifications The physical characteristics of the AC 1000 are shown in Table 1. Table 1. Physical Specifications Feature U.S. Metric Height (incl. cap).7 inches 2. centimeters Width (incl. mounting tabs).7 inches. centimeters epth (incl. stacking screws) 1 inch 2. centimeters Weight (without repeater) 7 ounces 1. grams Temperature 2 to 120 F 0 to C Humidity To % (no condensation)