Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C. TEL.: +886 2 8919 1230 FAX.: +886 2 8919 1231 Prepared by 244 No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C. TEL.: +886 2 2600 6861 FAX.: +886 2 2600 6859 Remark: The test report consists of 36 pages in total. It shall not be reproduced except in full, without the written approval of IETC. This document may be altered or revised by IETC only, and shall be noted in the revision section of the document. The test results in the report only to the tested sample.
Report No.: 9A042401C2 Page 2 of 36 Table of Contents 1 General Information 5 1.1 Description of Equipment Under Test 5 1.2 Summary of Test Results 6 1.3 Details of Tested Supporting System 7 1.4 Test Facility 8 1.5 Measurement Uncertainty 9 1.6 Measured Mode 10 1.7 Configuration of EUT Setup 10 1.8 Test Step of EUT 10 2 Power Line Conducted Emission 11 2.1 Instrument 11 2.2 Test Requirement 11 2.3 Test Procedures 11 2.4 Test Result 11 3 Radiated emission 14 3.1 Instrument 14 3.2 Test Requirement 14 3.3 Test Procedures 14 3.4 Test Result 14 4 Performance Criterion of Immunity Test 17 4.1 EN 50121-1 17 5 Electrostatic Discharge Test 18 5.1 Instrument 18 5.2 Test Requirement 18 5.3 Test Procedures 18 5.4 Test Result 18 6 Radio- Frequency, Electromagnetic Field Immunity Test 19 6.1 Instrument 19 6.2 Test Requirement 19 6.3 Test Procedures 19 6.4 Test Result 19 7 Transient Burst Susceptibility Test 20 7.1 Instrument 20 7.2 Test Requirement 20 7.3 Test Procedures 20 7.4 Test Result 20
Report No.: 9A042401C2 Page 3 of 36 8 Surges Test 21 8.1 Instrument 21 8.2 Test Requirement 21 8.3 Test Procedures 21 8.4 Test Result 21 9 Radio- Frequency, Conducted Disturbances Immunity Test 22 9.1 Instrument 22 9.2 Test Requirement 22 9.3 Test Procedures 22 9.4 Test Result 22 10 Power Frequency Magnetic Field Immunity Test 23 10.1 Instrument 23 10.2 Test Requirement 23 10.3 Test Procedures 23 10.4 Test Result 23 11 Pulsed magnetic field Immunity Test 24 11.1 Instrument 24 11.2 Test Requirement 24 11.3 Test Procedures 24 11.4 Test Result 24 12 Photographs of Test 25 12.1 Power Line Conducted Emission Measurement 25 12.2 Radiated Emission Measurement 26 12.3 Electrostatic Discharge Test Point 27 13 Photographs of EUT 28
Report No.: 9A042401C2 Page 5 of 36 1 General Information 1.1 Description of Equipment Under Test Product Model Number Applicant Manufacturer Power Supply : Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client : AWK-5222 Date of Receipt of Sample : Mar. 21, 2009 : MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C. : MOXA Inc. Fl.4, No.135, Lane 235, Pao-Chiao Rd., Shing Tien City, Taipei, R.O.C. : Input: 12 ~ 48VDC Date of Test : Mar. 21 ~ 24, 2009 Product Information : Interface/ Port: 1. LAN Port *2 2. RS-232 Console Port *1 3. DIDO Port *1 Additional Description : 1) The EUT is Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client. 2) The Model Number AWK-5222 is representative selected in the test and included in this report. 3) For more detail specification about EUT, please refer to the user s manual.
Report No.: 9A042401C2 Page 6 of 36 1.2 Summary of Test Results Report Clause Phenomenon EN 50121-4 Reference Clause(s) 2 Power Line Conducted Emission 5 3 Radiated Emission 5 Reference standard EN 61000-6-4 CISPR 16-2-1 CISPR 16-1-2 EN 61000-6-4 CISPR 16-2-3 Result Applicable Applicable 5 Electrostatic Discharge 6 EN 61000-4-2 Applicable 6 Radio- Frequency, Electromagnetic Field 6 EN 61000-4-3 Applicable 7 Transient Burst Susceptibility 6 EN 61000-4-4 Applicable 8 Surges 6 EN 61000-4-5 Applicable 9 Radio- Frequency, Conducted Disturbances 6 EN 61000-4-6 Applicable 10 Power frequency magnetic field 6 EN 61000-4-8 Applicable 11 Pulsed magnetic field 6 EN 61000-4-9 Applicable
Report No.: 9A042401C2 Page 7 of 36 1.3 Details of Tested Supporting System 1.3.1 Link PC PC23 Model Number : ASUS-M500 CPU Speed : Intel Celeron 430 EMC Compliance : BSMI R31018 Manufacturer : ASUS RAM : Nanya 1G DDR2 800 Hard Disk Driver : Seagate ST380815AS 80G Switching Power Supply : Detal GPS-300AB C 300W Power Cord : Non-shielded, Detachable, 1.8m, w/o core 1.3.2 Battery Model Number : HR9-12 Manufacturer : BB BATTERY 1.3.3 Cable Power Cord : Non-shielded Detachable, 1.8 m w/o core RJ45 Cable : Non-shielded Detachable, 1.6 m w/o core
Report No.: 9A042401C2 Page 8 of 36 1.4 Test Facility Site Description : Conduction 1 OATS 1 EMS Site Name of Firm : Company web : http://www.ietc.com.tw Site 1, 2 Location : No.5-2, Lin 1, Tin-Fu Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C. Site 3, 4 Location : No. 12, Ruei-Shu Valley, Ruei-Ping Tsun, Lin-Kou Hsiang, Taipei County, Taiwan, R.O.C. Site Filing : Federal Communication Commissions USA Registration No.: 96399 (OATS 1 & 2) Registration No.: 518958 (OATS 3 & 4) Designation No.: TW1020 Voluntary Control Council for Interference by Information Technology Equipment (VCCI) Japan Member No.: 1349 Registration No. (Conducted Room): C-1094 Registration No. (Conducted Room): T-271 Registration No. (OATS 1): R-1040 Registration No. (OATS 2): R-1041 Industry Canada (IC) OUR FILE: 46405-4437 Submission: 130946 Registration No. (OATS 1): 4437A-1 Registration No. (OATS 2): 4437A-2 Registration No. (OATS 3): 4437A-3 Registration No. (OATS 4): 4437A-4 Japan Electrical Safety & Environment Technology Laboratories (JET) Registration No.: 04S03-01 Site Accreditation : Bureau of Standards and Metrology and Inspection (BSMI) Taiwan, R.O.C. Accreditation No.: SL2-IN-E-0026 for CNS13438 / CISPR22 SL2-R1-E-0026 for CNS13439 / CISPR13 SL2-R2-E-0026 for CNS13439 / CISPR13 SL2-A1-E-0026 for CNS13783-1 / CISPR14-1 Taiwan Accreditation Foundation (TAF) Accreditation No.: 1113 TüV NORD Certificate No: TNTW0801R-01
Report No.: 9A042401C2 Page 9 of 36 1.5 Measurement Uncertainty No. Item Value 1 Power Line Conducted Emission (Conduction 1) 2.40 db 2 Power Line Conducted Emission (Conduction 2) 2.40 db 3 Disturbance Power Emission (Conduction 2) 3.10 db 4 Click disturbances Emission (Conduction 2) 2.40 db 5 Radiated Electromagnetic disturbance (Loop Antenna) 4.80 db 6 Radiated Emission Test (OATS 1) 3.14 db 7 Radiated Emission Test (OATS 2) 3.14 db 8 Radiated Emission Test (OATS 3) 3.14 db 9 Radiated Emission Test (OATS 4) 3.14 db 10 Radiated Emission Test (1GHz~18GHz) 3.20 db 11 Radiated Emission Test (18GHz~40GHz) 3.40 db
Report No.: 9A042401C2 Page 10 of 36 1.6 Measured Mode 1.6.1 The test mode for final test is as following: Mode 1: Working mode (DC Power Port) 1.7 Configuration of EUT Setup Battery Link PC EUT 1.8 Test Step of EUT 1.8.1 Setup the EUT and peripheral as above. 1.8.2 Turn on the power of all equipment. 1.8.3 PC executed "Ping.exe" to link with the EUT to receive and transmit data by UTP cable. 1.8.4 Executed the test.
Report No.: 9A042401C2 Page 11 of 36 2 Power Line Conducted Emission 2.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMI Test Receiver Rohde & Schwarz ESCS 30 830245/027 2009/08/19 Pulse Limiter Rohde & Schwarz ESH3-Z2 843602/02 2009/09/08 RF Cable HARBOUR RG400 CBL32 2010/03/16 L.I.S.N. Schwarzbeck NNLK8121 8121417 2009/07/21 L.I.S.N. Rohde & Schwarz ESH3-Z5 100176 2010/02/18 Note: The above equipments are within the valid calibration period. 2.2 Test Requirement Reference to EN 50121-4 clause 5 and EN 61000-6-4 table 1 Frequency (MHz) Q.P. (Quasi-Peak) A.V. (Average) 0.15 ~ 0.50 79 66 0.50 ~ 5.0 73 60 5.0 ~ 30 73 60 2.3 Test Procedures Reference to CISPR 16-2-1 clause 7.4.1 and CISPR 16-1-2 clause 4.3 2.4 Test Result PASS. The final test data is shown on as following pages.
Report No.: 9A042401C2 Page 12 of 36 EUT: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client CLIENT: MOXA Inc. MODEL: AWK-5222 RATING: DC 12V Temperature: 25.0 Humidity: 68 % Power Line Conducted Test Data POLARITY: Line DISTANCE: Serial No.: FILE/DATA#: MOXA Inc.emi/61 OPERATOR: Terry TEST SITE: Conduction1 Frequency Factor Meter Reading (dbµv) Emission Level (dbµv) Limits (dbµv) Margin (db) (MHz) (db) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average 0.201 0.15 45.70 46.22 45.85 46.37 63.57 53.57-17.72-7.20 0.384 0.17 34.23 34.15 34.40 34.32 58.19 48.19-23.79-13.87 0.603 0.11 34.80 34.27 34.91 34.38 56.00 46.00-21.09-11.62 1.009 0.12 34.61 34.68 34.73 34.80 56.00 46.00-21.27-11.20 16.541 0.74 36.68 34.20 37.42 34.94 60.00 50.00-22.58-15.06 18.912 0.81 49.90 49.00 50.71 49.81 60.00 50.00-9.29-0.19 Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss. Test Mode: Mode 1: Working Mode (DC Power Port)
Report No.: 9A042401C2 Page 13 of 36 EUT: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client CLIENT: MOXA Inc. MODEL: AWK-5222 RATING: DC 12V Temperature: 25.0 Humidity: 68 % Power Line Conducted Test Data POLARITY: Neutral DISTANCE: Serial No.: FILE/DATA#: MOXA Inc.emi/60 OPERATOR: Terry TEST SITE: Conduction1 Frequency Factor Meter Reading (dbµv) Emission Level (dbµv) Limits (dbµv) Margin (db) (MHz) (db) Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average Quasi-Peak Average 0.193 0.16 48.20 48.10 48.36 48.26 63.91 53.91-15.55-5.65 0.380 0.18 37.43 37.40 37.61 37.58 58.28 48.28-20.67-10.70 1.005 0.13 32.17 31.99 32.30 32.12 56.00 46.00-23.70-13.88 16.552 0.84 38.40 34.94 39.24 35.78 60.00 50.00-20.76-14.22 18.892 0.92 49.10 48.30 50.02 49.22 60.00 50.00-9.98-0.78 28.373 1.16 34.41 31.09 35.57 32.25 60.00 50.00-24.43-17.75 Remark: 1. All readings are Quasi-Peak and Average values. 2. Factor = Insertion Loss + Cable Loss. Test Mode: Mode 1: Working Mode (DC Power Port)
Report No.: 9A042401C2 Page 14 of 36 3 Radiated emission 3.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMI Test Receiver Rohde & Schwarz ESCS30 100135 2009/09/10 Bilog Antenna Schaffner CBL6111c 2804 2010/02/22 Pre-Amplifier Agilent 8447D 1937A01903 2009/12/08 RF Cable IETC CBL15 CBL15 2009/11/18 Note: The above equipments are within the valid calibration period. 3.2 Test Requirement Reference to EN 50121-4 clause 5 and EN 61000-6-4 table 1 Quasi-Peak Frequency (MHz) db(µv/m) 3.3 Test Procedures 30 ~ 230 40.0 230 ~ 1000 47.0 Reference to CISPR 16-2-3 3.4 Test Result PASS. The final test data is shown on as following pages.
Report No.: 9A042401C2 Page 15 of 36 EUT: Radiated Emission Measurement Data Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client POLARITY: Horizontal DISTANCE: 10 m CLIENT: MOXA Inc. MODEL: AWK-5222 RATING: DC 12V Temperature: 23.0 Serial No.: FILE/DATA#: MOXA Inc.emi/22 OPERATOR: Edison TEST SITE: OATS1 Humidity: 55 % Frequency Factor Meter Reading Emission Level Limits Margin (MHz) (db) (dbµv) (dbµv/m) (dbµv/m) (db) 250.000 ** -14.93 48.16 33.23 37.00-3.77 400.000 ** -10.21 39.90 29.69 37.00-7.31 500.000 ** -8.20 40.95 32.75 37.00-4.25 700.000 ** -3.00 33.26 30.26 37.00-6.74 800.000 ** -1.60 33.06 31.46 37.00-5.54 833.000 ** 0.21 28.26 28.47 37.00-8.53 900.000 ** 0.48 25.95 26.43 37.00-10.57 Remark: 1. * Mark means readings are Peak Values. 2. ** Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss Pre-amplifier. Test Mode: Mode 1: Working Mode (DC Power Port)
Report No.: 9A042401C2 Page 16 of 36 EUT: Radiated Emission Measurement Data Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client POLARITY: Vertical DISTANCE: 10 m CLIENT: MOXA Inc. MODEL: AWK-5222 RATING: DC 12V Temperature: 23.0 Serial No.: FILE/DATA#: MOXA Inc.emi/21 OPERATOR: Edison TEST SITE: OATS1 Humidity: 55 % Frequency Factor Meter Reading Emission Level Limits Margin (MHz) (db) (dbµv) (dbµv/m) (dbµv/m) (db) 250.001 ** -14.81 47.62 32.81 37.00-4.19 400.120 ** -9.92 38.26 28.34 37.00-8.66 500.000 ** -7.75 40.52 32.77 37.00-4.23 800.000 ** -1.75 29.85 28.10 37.00-8.90 833.240 ** 0.23 28.12 28.35 37.00-8.65 900.000 ** 0.44 31.25 31.69 37.00-5.31 Remark: 1. * Mark means readings are Peak Values. 2. ** Mark means readings are Quasi-Peak values. 3. Factor = Antenna Factor + Cable Loss Pre-amplifier. Test Mode: Mode 1: Working Mode (DC Power Port)
Report No.: 9A042401C2 Page 17 of 36 4 Performance Criterion of Immunity Test 4.1 EN 50121-1 Criterion A B C Description The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation, and from what the user may reasonably expect from the apparatus if used as intended. Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls.
Report No.: 9A042401C2 Page 18 of 36 5 Electrostatic Discharge Test 5.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date ESD Simulator EMC PARTNER ESD3000 241 2009/10/19 Note: The above equipments are within the valid calibration period. 5.2 Test Requirement Reference to EN 50121-4 clause 6 Air discharge: ±8 KV Contact discharge: ±6 kv Indirect discharge: ±6 kv Performance criterion: B 5.3 Test Procedures Reference to IEC 61000-4-2 clause 8 5.4 Test Result Temperature: 23.5 ; Humidity: 57 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN 50121-1: Air discharge ±2 kv, ±4 kv, ±8 kv, ±15 kv: A B C Contact discharge ±2 kv, ±4 kv, ±6 kv, ±8 kv: A B C Indirect discharge (HCP) ±2 kv, ±4 kv, ±6 kv, ±8 kv: A B C Indirect discharge (VCP Front, Left, Back, Right) ±2 kv, ±4 kv, ±6 kv, ±8 kv: A B C
Report No.: 9A042401C2 Page 19 of 36 6 Radio- Frequency, Electromagnetic Field Immunity Test 6.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date RF Power Amplifier (80MHz~1GHz) Frankonia FLG-200B 1038 N. C. R RF Power Amplifier (1GHz~3GHz) Frankonia FLG-50C 1013 N. C. R Directional Coupler (80MHz~1GHz) Werlatone C5982 37354 N. C. R Directional Coupler (1GHz~3GHz) Werlatone C6187 37355 N. C. R Bilog Antenna (20MHz~3GHz) Frankonia BTA-M 06012M N. C. R Signal Generator R&S SM300 101768 2009/10/14 RF Power Meter Anritsu ML2945A 736010 2009/10/16 Electric Field Probe Narda 2244/90.21 BF-0045 2010/11/06 Field-strength-meter Narda EMR-20 BC-0028 2010/11/06 Note: The above equipments are within the valid calibration period. 6.2 Test Requirement Reference to EN 50121-4 clause 6 The frequency steps: 1%, Log sweep, Dwell time: 3.0 sec. Frequency range: 80 to 1000 MHz, Field strength: 20 V/m, 80% AM (1kHz), (Note: For equipment mounted in network communication center a severity level of 10V/m may be used.) Frequency range: 1400 to 2100 MHz, Field strength: 10 V/m, 80% AM (1kHz), Frequency range: 2100 to 2500 MHz, Field strength: 5 V/m, 80% AM (1kHz), Performance criterion: A 6.3 Test Procedures Reference to IEC 61000-4-3 clause 8 6.4 Test Result Temperature: 23.0 ; Humidity: 57 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN 50121-1: Frequency range: 80 to 1000 MHz, Field strength: 20 V/m, 80% AM (1kHz), Performance criterion: A B C Frequency range: 1400 to 2100 MHz, Field strength: 10 V/m, 80% AM (1kHz), Performance criterion: A B C Frequency range: 2100 to 2500 MHz, Field strength: 5 V/m, 80% AM (1kHz), Performance criterion: A B C
Report No.: 9A042401C2 Page 20 of 36 7 Transient Burst Susceptibility Test 7.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMC Pro System KeyTek EMC Pro 0003231 2010/03/16 EFT Clamp KeyTek PRO-CCL-C 0003198 N. C. R. Note: The above equipments are within the valid calibration period. 7.2 Test Requirement Reference to EN 50121-4 clause 6 5 khz Repetition frequency ±2.0 kv input AC power ports. ±2.0 kv input DC power ports. ±2.0 kv for Signal ports. Performance criterion: A 7.3 Test Procedures Reference to IEC 61000-4-4 clause 8 7.4 Test Result Temperature: 23.5 ; Humidity: 57 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN 50121-1: ±4.0 kv input DC power port: Line+ Neutral + PE Performance criterion: A B C ±2.0 kv On I/O (input/output) signal, data and control port: RJ45 Performance criterion: A B C
Report No.: 9A042401C2 Page 21 of 36 8 Surges Test 8.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date EMC Pro Systems KeyTek EMC Pro 0003234 2010/03/15 Surge Telecom Box KeyTek CM-TELCD 0202316 N. C. R. Note: The above equipments are within the valid calibration period. 8.2 Test Requirement Reference to EN 50121-4 clause 6 Input AC power ports: Line to Neutral: ±1kV (peak), 1.2/50 us, 42Ω, 0.5µF Line (Neutral) to earth: ±2kV (peak), 1.2/50 us, 42Ω, 0.5µF Input DC power ports: Line to Neutral: ±1kV (peak), 1.2/50 us, 42Ω, 0.5µF Line (Neutral) to earth: ±2kV (peak), 1.2/50 us, 42Ω, 0.5µF Signal and telecommunication ports: ±2kV(peak): 1.2/50 us, 42Ω, 0.5µF Performance criterion: B 8.3 Test Procedures Reference to IEC 61000-4-5 clause 8 8.4 Test Result Temperature: 24.0 ; Humidity: 59 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN 50121-1: ±0.5 kv (peak) Input DC power port: Line to line Performance criterion: A B C ±1.0 kv (peak) Input DC power port: Line to line Performance criterion: A B C ±0.5 kv (peak) Input DC power port: Line to earth (ground) Performance criterion: A B C ±1.0kV(peak) Input DC power port: Line to earth (ground) Performance criterion: A B C ±2.0kV(peak) Input DC power port: Line to earth (ground) Performance criterion: A B C ±2.0kV(peak) Signal port: RJ45 Performance criterion: A B C
Report No.: 9A042401C2 Page 22 of 36 9 Radio- Frequency, Conducted Disturbances Immunity Test 9.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date Signal Generator R&S SMY02 829846/013 2009/07/20 Power Amplifier Frankonia CIT-10 162D1278 N. C. R. Coupler WERLATONE C2630 8067 N. C. R. Attenuator SCHAFFNER ATN6075 22300 N. C. R. M3 C.D.N FCC FCC-801-M3-25A 2045 N. C. R. M2 C.D.N SCHAFFNER M216 16394 N. C. R. EM-CLAMP SCHAFFNER KEMZ 801 17037 N. C. R. Note: The above equipments are within the valid calibration period. 9.2 Test Requirement Reference to EN 50121-4 clause 6 Frequency range: 0.15 to 80 MHz, Field strength: 10 V, 80% AM (1kHz) Input AC power ports. Input DC power ports. Signal and telecommunication ports. Performance criterion: A 9.3 Test Procedures Reference to EN 61000-4-6 clause 8 9.4 Test Result Temperature: 21.0 ; Humidity: 55 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN 50121-1: Frequency range: 0.15 to 80 MHz, Field strength: 10 V, 80% AM (1kHz), Input DC power port. Performance criterion: A B C Signal and telecommunication port. Performance criterion: A B C
Report No.: 9A042401C2 Page 23 of 36 10 Power Frequency Magnetic Field Immunity Test 10.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date Magnetic field generator PMM PMM1008 0000J00301 2010/09/04 Note: The above equipments are within the valid calibration period. 10.2 Test Requirement Reference to EN 50121-4 clause 6 AC Systems (100A/m) Power Frequency: 16.7Hz Power Frequency: 50Hz Power Frequency: DC 0Hz DC Systems (300A/m) Power Frequency: 16.7Hz Power Frequency: 50Hz Power Frequency: DC 0Hz Performance criterion: A Note: Test only applies to apparatus containing devices sensitive to magnetic fields e.g. Hall elements, electro-dynamic microphones etc. 10.3 Test Procedures Reference to EN 61000-4-8 clause 8 10.4 Test Result PASS. The EUT is not containing devices sensitive to magnetic fields.
Report No.: 9A042401C2 Page 24 of 36 11 Pulsed magnetic field Immunity Test 11.1 Instrument Instrument Manufacturer Model Serial No. Next Cal. Date Magnetic field generator PMM PMM1008 0000J00301 2010/09/04 Note: The above equipments are within the valid calibration period. 11.2 Test Requirement Reference to EN 50121-4 clause 6 Pulsed magnetic field: 300 A/m Performance criterion: B 11.3 Test Procedures Reference to EN 61000-4-9 clause 8 11.4 Test Result Temperature: 21.0 ; Humidity: 56 %; Atm pres: 101 Kpa; Test Engineer: Victor PASS. The performance criterion after tested EN 50121-1: Pulsed magnetic field: 300 A/m Performance criterion: A B C
Report No.: 9A042401C2 Page 25 of 36 12 Photographs of Test 12.1 Power Line Conducted Emission Measurement Front View Rear View
Report No.: 9A042401C2 Page 26 of 36 12.2 Radiated Emission Measurement Front View Rear View
Report No.: 9A042401C2 Page 27 of 36 12.3 Electrostatic Discharge Test Point View of Discharge Point-1 (Green: Air discharge; Red: Contact discharge) View of Discharge Point-2 (Green: Air discharge; Red: Contact discharge)
Report No.: 9A042401C2 Page 28 of 36 13 Photographs of EUT Front View of EUT Rear View of EUT
Report No.: 9A042401C2 Page 29 of 36 Inner View of EUT-1 Inner View of EUT-2
Report No.: 9A042401C2 Page 30 of 36 Inner View of EUT-3 Inner View of EUT-4
Report No.: 9A042401C2 Page 31 of 36 Inner View of EUT-5 Inner View of EUT-6
Report No.: 9A042401C2 Page 32 of 36 Front View of Main Board-1 Rear View of Main Board-1
Report No.: 9A042401C2 Page 33 of 36 Front View of Main Board-2 Rear View of Main Board-2
Report No.: 9A042401C2 Page 34 of 36 Front View of WLAN Board (Module A) Rear View of WLAN Board (Module A)
Report No.: 9A042401C2 Page 35 of 36 Front View of WLAN Board (Module B) Rear View of WLAN Board (Module B)
Report No.: 9A042401C2 Page 36 of 36 View of Antenna Antenna Connector