Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Similar documents
Installation Instructions 3040 (05-09) 9/16 9/ /32 9/32. Checking Adjustments

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

ASSA ABLOY. Model W91 Overhead Concealed Wood Frame Installation Instructions IMPORTANT: BEFORE INSTALLING: TO DETERMINE HAND OF YOUR DOOR:

Installation Instructions. Installation Type

Installation Instructions. Installation Type

DC3210. Recommended Closer Size

7130(F) Series Mortise Exit Devices Installation Instructions

1510(F) Surface Vertical Rod Exit Devices Installation Instructions

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Owner s Maintenance Section

1500(F) Rim Exit Devices Installation Instructions

1530(F) Mortise Exit Devices Installation Instructions

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

ED5200(A) Series Rim Exit Devices

PFD-22 Top OHC Patch Fitting & PFD-10 Bottom Patch Fitting Installation Instructions

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Installation Instructions

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

316R Series Installation Instructions

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

THRESHOLDS. Finishing Touch for Floor Closer Installations

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

Instructions for the installation of Ellison Bronze balanced door models #137 & 138

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

*18758* 2030 Series. 1 Installation. 2 Adjustment. 3 Hold Open Information BACKCHECK. * Hold open tracks. Installation Instructions

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

PIVOT DOOR 3400P INSTALLATION INSTRUCTIONS

Senior Swing. Caution

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Troubleshooting The Product You Have

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Installation Instructions ED4400, ED4400M & ED4400MA Series Surface Vertical Rod Exit Devices

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Installing Your Electronic Deadbolt

WD WD7000 Series

CRL JACKSON 900 SERIES

INSTALLATION INSTRUCTIONS Frames and Entrance Doors

Checkmate Stops & Holders. Absolute Door Control and Entire Opening Protection

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

s tops & holder s Absolute Door Control and Entire Opening Protection

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Preference Collection and Treatment Console INSTALLATION GUIDE

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Overhead Concealed Closers

Specialty Closers. High-End Residential High-End Security Gate Solutions

TH955 & TH959. Heavy Duty Thumbpiece Trim For use with ED5000 Series Exit Device. Metal, Wood or Composite Doors

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

Shetland Stalls Installation Instructions

Swing Door Installation Manual

INSTALLATION INSTRUCTIONS

Shallow Depth Floor Closers. Complete Premium Door Control for Medium-Duty Interior Doors Where Concealment is Desired

Installation Instructions

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

How To Measure Your Finished Opening

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

ED3000 Series. Exit Device Parts Manual

BEFORE STARTING INSTALLATION

Heavy-Duty Bypass Track System

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

INSTALLATION INSTRUCTIONS

Double Frameless Swing Door QCI5247

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

SolidStep 3.0 OEM INSTALLATION MANUAL

Series 9000 Panel Door; In-Line, Corner and Permanent Wall Application

ESA-300 Full Breakout

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

WPS crew Doors Installation instructions

Heavy Wall Applied Stop Tube Frame and Door Installation

MORTISE LOCK INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Tools Required. * When installing on a fire door, please see instructions below. *

5200 Series Door Closer Installation Instructions

Installation Instructions

Victory Fire Door Inspections

ESA-200 Fixed Sidelite

INSTALLATION INSTRUCTIONS

Finish Hardware. Contents. Section 10

ICU TRACKLESS SLIDING DOOR

Installation Instructions for 45H & 47H Mortise Locks

2. Skid should contain the following: A door & jamb B casing C seal cover kit & D extension jamb set (if ordered), E hardware box.

SECTION FINISH HARDWARE

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

LC200DS1 Double Stud Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

Transcription:

RIXSON ASSA ABLOY 3/4 Template Jamb 1/8 2- R. Max. 1-7/16 1-1/32 2-2-3/4 7/8 Dia. C L 1-1/4 Dia. Installation Instructions 50 (06-09) Finish Plate 340 TOP PIVOT Pivot Shown Engaged 9/16 1/16 1/4 1-15/32 15/32 21/32 1/4-20 x " FHMS or #14 x 1/2" FHWS Floor Plate 50 Floor Closer Center Hung Single or Double Acting Non-Handed 6-3/4 JAMB PORTION 4-1/2 12-24 x " FHMS or #12 x 1-1/4" FHWS 1-1/8 DOOR PORTION Floor Plate 4-1 5- Cement Case 1-5/16 1/4-20 x " FHMS or #14 x 1-1/2" FHWS 1-1/4 1-3/8 Min. Clearance Required for, Plate H and Shims 7/8 Door Mortised 1-9/16 Deep for 1/8 2- Provide 3/8 Dia. Hole 1-1/16 (11/16 w/ Threshold) Plate 10-3/4 7-7/16 Fasten Front Mounting Screws First 19-1/4 7/16 With Threshold Use Top (2) Holes Cement Case With Floor Plate Use Bottom (2) Holes 1-9/16 2 4-3/8 WITH FLOOR PLATE Set Cement Case Flush with Finished Floor See Note 5 Door Mortised Deep for A 1/4 Threshold 1-1 1/2 Threshold 1-9/16 See Note 5 B A B 1-1/8 7/8 2-3/4 19-1/8 Threshold 1-1/4 1/4-20 x 1 FHMS or #14 x 2 FWHS (4 Places) Conversion from inches to metric: inch x 25.4. C L 1-25/32 1-7/32 1-1 1-13/32 2-3/32 3-1 ARM PLATE H 11/32 2 See Note 4 Tighten Screw Firmly Washer Adapter WITH THRESHOLD Set Cement Case Flush with Finished Floor Notes: 1. Do not scale drawing. 2. Suitable reinforcing by others. 3. Rixson design threshold available on request. 4. Tighten adjusting screw to notched V line on arm to acquire standard initial location of door. Screw moves door towards and away from jamb to equalize door clearances. 5. Provide dia. holes for alignment screws (2 places). 6. Do not remove grind plate until closer is installed. 7. External stop by others required. 8. All dimensions given in inches.

PAGE 2 How To Determine Hand of Door LH RH Top Pivot Jamb Portion Top Pivot Door Portion IMPORTANT: Use plumb line to make sure that center line of top pivot pin lines up with center line of closer spindle. Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. Adjusting Screw Plate H Alignment Screws Installation Instructions 1. Locating Closer Door Jamb Position Centerline of Door and A. Measure 2-3/4 out from door jamb on centerline of door. This is the location of the spindle center. 2-3/4 From Face of Jamb to C of L 2. Install Cement Case in Floor LEVEL IN BOTH DIRECTIONS A. Cement case is set flush with finished floor. B. Set cement case with closer in floor and block in position. C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. E. Grout in cement case with closer. Cement should not get between closer and case.

3. Install Top Pivot and Closer PAGE 3 A. Install top pivot in door per template. DOOR B. Install top pivot in jamb per template. Plate H Closer in Floor C. Centerline of pivot pin should line up with centerline of spindle. Use plumb line to assure accuracy. If center lines don t line up, loosen hold down screws (4) and reposition closer. Tighten hold down screws closest to spindle first. Then tighten screws at cylinder end. Note: Closer must be lifted approx. 1/8 before repositioning. D. Mortise door for arm, arm plate H, and wood door arm plate. Refer to template. E. Drill two dia. holes for arm alignment screws. Drill 3/8 hole at heel edge of door for adjusting screw. F. Install arm, arm plate H, and shims if required. Attach arm alignment screws and washers to hold arm in place. 4. Hang Door Top Pivot Pin Centerline of Door 30 Pin Retracting Screw CAUTION: Closer is shipped with "valve" screws down. DO NOT FORCE VALVE DOWN. A. Close both valve screws. NEVER FORCE VALVE SCREW DOWN AS THIS WILL DAMAGE TIP SEATING. B. With arm on spindle, turn spindle until arm is in 30 open position (see illustration). C. Set door on spindle. DO NOT ATTEMPT TO CLOSE DOOR. D. Align two portions of top pivot and turn pin retracting screw clockwise to engage top pivot pin. E. Open door to 60 or more and turn valve screws counterclockwise. Door will then close. F. If necessary, turn adjusting screw at bottom of heel edge of door to equalize side jamb clearances. Adjusting Screw G. Adjust arm alignment screws equally from each side to center door in doorway. Alignment Screws

Closer Adjustment PAGE 4 + - BACK CHECK DELAY F S STROKE LATCH F S F S Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. A. The stroke valve allows adjustment from open to 15. B. The latch valve allows adjustment from 15 to closed position. C. IMPORTANT: Back check valve option must be adjusted to vary resistance from light to firm at 70 of door opening. D. The delay valve option allows closing speed adjustment from open position to 65. Repairs, parts replacement or internal adjustments must be done by a Rixson authorized repair agency. Consult for an authorized repair agency in your area. Rixson is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. RIXSON ASSA ABLOY

RIXSON 3/4 ASSA ABLOY Template 1/8 1-7/16 1-1/32 2-2-3/4 7/8 Dia. 1-1/4 Dia. TOP PIVOT Installation Instructions 50W (06-09) Finish Plate 9/16 1/16 1/4 1-15/32 15/32 21/32 1/4-20 x " FHMS or #14 x 1/2" FHWS W50 Floor Closer Center Hung Single or Double Acting Non-Handed Wood Door Installation 6-3/4 JAMB PORTION 12-24 x " FHMS or #12 x 1-1/4" FHWS 1-1/8 DOOR PORTION 4-1 5-1-5/16 1/4-20 x " FHMS or #14 x 1-1/2" FHWS 1-1/4 Jamb 2- R. Max. C L Floor Plate 4-1/2 Provide 9/16 Dia. Hole for Alignment Screw Floor Plate 1-3/8 Min. Clearance Required for, Plate H and Shims 1-1/4 Door Mortised 1-7/8 Deep for Cement Case Shim Plate 7/16 Wood Door Plate Shoulder Collar Fasten Front Mounting Screws First 19-1/4 1/8 2-9* 2-1/4* 7-7/16 *Mortised Provide 3/8 Dia. Hole Use Top (2) Holes Cement Case 2 4-3/8 WITH FLOOR PLATE Set Cement Case Flush with Finished Floor Provide 9/16 Dia. Hole for Alignment Screw Door Mortised Deep for A B 1/4 Threshold 1-3/4 1-1/8 1/2 Threshold 1-1/2 7/8 B A 2-3/4 19-1/8 Threshold 2-3/32 1-25/32 9/16 1-1 C L 4-7/32 1-7/32 C L Door 1-13/32 6-7/32 10-1/2 WOOD DOOR ARM PLATE Conversion from inches to metric: inch x 25.4. #14 x 2-1/2 FWHS (6 Places) 11/16 1-3/8 See Note 4 Tighten Screw Firmly WITH THRESHOLD Set Cement Case Flush with Finished Floor Notes: 1. Do not scale drawing. 2. Suitable reinforcing by others. 3. Rixson design threshold available on request. 4. Tighten adjusting screw to notched V line on arm to acquire standard initial location of door. Screw moves door towards and away from jamb to equalize door clearances. 5. Auxiliary stop required. 6. All dimensions given in inches.

PAGE 2 How To Determine Hand of Door LH RH Top Pivot Jamb Portion Top Pivot Door Portion Shim Plate H IMPORTANT: Use plumb line to make sure that center line of top pivot pin lines up with center line of closer spindle. Wood Door Plate Face a door swinging open away from you. If it opens to the right, it is right hand. If it opens to the left, it is left hand. Adjusting Screw Plate H Alignment Screws Installation Instructions 1. Locating Closer Door Jamb Position Centerline of Door and A. Measure 2-3/4 out from door jamb on centerline of door. This is the location of the spindle center. 2-3/4 From Face of Jamb to C of L 2. Install Cement Case in Floor LEVEL IN BOTH DIRECTIONS A. Cement case is set flush with finished floor. B. Set cement case in floor and block in position. C. Case should be parallel with center line of door. D. CEMENT CASE SHOULD BE LEVEL. Place levels per Illustration. E. Grout in cement case with closer. Cement should not get between closer and case.

3. Install Top Pivot and Closer PAGE 3 A. Install top pivot in door per template. DOOR B. Install top pivot in jamb per template. Shim Plate H Closer in Floor Wood Door Plate C. Centerline of pivot pin should line up with centerline of spindle. Use plumb line to assure accuracy. If center lines don t line up, loosen hold down screws (4) and reposition closer. Tighten hold down screws closest to spindle first. Then tighten screws at cylinder end. Note: Closer must be lifted approx. 1/8 before repositioning. D. Mortise door for arm, arm plate H, and wood door arm plate. Refer to template. E. Drill two 9/16 dia. holes for arm alignment screws. Drill 3/8 hole at heel edge of door for adjusting screw. F. Attach arm to spindle using spindle screw supplied and tighten securely. Install arm plate H, wood door arm plate, and shim. 4. Hang Door Top Pivot Pin Centerline of Door 30 Pin Retracting Screw CAUTION: Closer is shipped with "valve" screws down. DO NOT FORCE VALVE DOWN. A. Close both valve screws. NEVER FORCE VALVE SCREW DOWN AS THIS WILL DAMAGE TIP SEATING. B. With arm on spindle, turn spindle until arm is in 30 open position (see illustration). C. Set door on spindle. DO NOT ATTEMPT TO CLOSE DOOR. D. Align two portions of top pivot and turn pin retracting screw clockwise to engage top pivot pin. E. Open door to 60 or more and turn valve screws counterclockwise. Door will then close. F. If necessary, turn adjusting screw at bottom of heel edge of door to equalize side jamb clearances. Adjusting Screw G. Adjust arm alignment screws equally from each side to center door in doorway. Alignment Screws

Closer Adjustment PAGE 4 + - BACK CHECK DELAY F S STROKE LATCH F S F S Closing speeds can be adjusted to suit local conditions and requirements. Label on closer face designates the purpose of each adjustment screw. Adjustments are for speed control. A. The stroke valve allows adjustment from open to 15. B. The latch valve allows adjustment from 15 to closed position. C. IMPORTANT: Back check valve option must be adjusted to vary resistance from light to firm at 70 of door opening. D. The delay valve option allows closing speed adjustment from open position to 65. Repairs, parts replacement or internal adjustments must be done by a Rixson authorized repair agency. Consult for an authorized repair agency in your area. Rixson is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright 2005, 2009, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. RIXSON ASSA ABLOY