Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Similar documents
Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-E 24/0.75

Power supply CP-D 24/1.3

Power supply CP-E 24/2.5

Power supply CP-D 12/2.1

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply

CP-T range Product group picture

CP-E range Benefits and advantages

CP-T range Benefits and advantages

Electronic timer CT-TGD.22

Electronic timer CT-SDD.22

Primary switch mode power supplies Product group picture

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Type CP-S, CP-C & CP-A Switch mode

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Control module CP-A CM

Three-phase monitoring relay

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Switching power supplies CP range, Linear power supplies CP-L range. Content

MINI-PS AC/24DC/1.3

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

QUINT-PS-24DC/24DC/10

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relay CM-PFS

Three-phase monitoring relays CM-PFE and CM-PFE.2

Control module CP-A CM

Liquid level monitoring relay CM-ENS.2x

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

MINI-PS AC/2X15DC/1

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Analog signal converters CC-E I/I

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Three-phase monitoring relay CM-PVE

QUINT-PS AC/24DC/40

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

QUINT-PS/ 3AC/24DC/10

Three-phase monitoring relay CM-PBE

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Electronic timer CT-MFS.21

Three-phase monitoring relay

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

QUINT-PS/ 3AC/24DC/40

Power supply CP-C.1 24/10.0 Product revision M F High-performance primary switch mode power supply

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

QUINT-PS/ 1AC/24DC/20

Electronic timer CT-SDE

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Analog signal converters CC range

Transcription:

2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer - adjustment of the output voltage single/parallel - sliding switch - adjustment of single or parallel operation Circuit diagram Features Rated output voltage 12 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 10 A Rated output power 120 W Supply range 115/230 V AC (90-132 V AC, 186-264 V AC, 210-370 V DC), auto select Typical efficiency of 84 % Low power dissipation and low heating Free convection cooling (no forced cooling with ventilators) Ambient temperature range during operation -25...+70 C Open-circuit, overload and short-circuit stable Integrated input fuse Redundancy unit CP-A RU offering true redundancy, available as accessory LEDs for status indication Approvals A UL 508, CAN/CSA C22.2 No.14 Approval refers to rated input voltage U IN H UL 60950, CAN/CSA C22.2 No.60950 Approval refers to rated input voltage U IN D GOST Marks a CE b C-Tick pending Order data Type Rated input voltage Rated output voltage / current CP-E 12/10.0 115 / 230 V AC auto select Order code 12 V DC / 10 A 1SVR 427 035 R1000 Order data - Accessories Type Description Order code CP-A RU Redundancy unit The CP-A RU provides decoupling of two CP-E power supply units < 48 V and 5 A. 1SVR 427 071 R0000 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped with two generous capacitors, which ensure mains buffering of at least 30 ms (at 230 V AC). That is why the devices can be used worldwide also in high fluctuating networks and battery-powered plants. 1

Operating mode By means of the potentiometer OUTPUT Adjust the output voltage can be adjusted within a range of 11.4 to 14.5 V DC. Thus, the power supply can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. The green LED OUTPUT OK is lightening during proper operation, i.e. when the output voltage is more than 75 %. The red LED OUTPUT LOW is lightening when the output voltage is less than 70 % of the rated output voltage. Switch single/parallel for selection of single or parallel operation. Installation Mounting The switch mode power supply can be snapped on a DIN rail according to EN 50022 as shown in the accompanying picture. For that the device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. 2CDC 272 017 F0b08 Demounting Remove the switch mode power supply as shown in the accompanying picture. For that the latching lever is pulled downwards by means of the screwdriver. Alternatively you can press the unlock button to release the device. Then in both cases the device can be unhinged from the mounting rail edge and removed. 2CDC 272 018 F0b08 Mounting position The devices have to be mounted horizontally with the input terminals on the bottom. In order to ensure a sufficient convection, the minimum distance to other modules should not be less than 25 mm in vertical and horizontal direction. 2CDC 272 019 F0b08 2

Installation Electrical connection Connect the input terminals L and N. The protective earth conductor PE must be connected. The installation must be executed acc. to EN 60950, provide a suitable disconnecting device (e. g. line protection switch) in the supply line. The input side is protected by an internal input fuse. Rate the lines for the maximum output current (considering the short-circuit current) or provide a separate fuse protection. We recommend to choose the cable section as large as possible in order to minimize voltage drops. Observe the polarity. The device is overload, short-circuit and open-circuit proof. The secondary side of the power supply unit is electrically isolated from the input and internally not earthed (SELV) and can therefore be earthed by the user according to the needs with L+ or L- (PELV). Connection diagram L- L- L+ L+ No Func. L L+ PWM N L- PE PE N L 2CDC 272 022 F0b08 L+, L- Output voltage L, N Input voltage No Function not connected PE Protective earth Safety instructions and warnings The device must be installed by qualified persons only and in accordance with the specific national regulations (e.g., VDE, etc.). The devices are maintenance-free chassis-mounted units. Disconnect system from supply network! Before any installation, maintenance or modification work: Disconnect the system from the supply network and protect against switching on. Before start of operation: Attention! Improper installation/operation may impair safety and cause operational difficulties or destruction of the unit. Before operation the following must be ensured: Connect to main according t the specific national regulations. Power supply cables and unit must be sufficiently fused. A disconnecting device has to be provided for the end product to disengage unit and supply cables from supply mains if required. The protective earth conductor must be connected to the terminal (Protection class I) The secondary side of the power supply unit is not earthed and can be earthed by the user according to the needs with L+ or L-. Rate the output lines for the output current of the power supply and connect thme with the correct polarity. In order to ensure sufficient air-cooling the distance to other devices has to be considered. In operation: Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shocks (danger to life)! Risk of burns: Depending on the operation conditions the enclosure can become very hot. The internal fuse is not user-replaceable. If the internal fuse blows, most probably the device is defective. In this case, an examination of the switch mode power supply by the manufacturer is necessary. Attention! High voltage! Danger to life! The power supplies contain components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit, and do not open the unit. With some units of this range the output is capable of providing hazardous energy. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. 3

Technical data Data at T a = 25 C, U IN = 230 V AC and rated values, if nothing else indicated Type CP-E 12/10.0 Input circuit L, N Rated input voltage U IN 115 / 230 V AC auto select Input voltage range 90-132 V AC, 186-264 V AC / 210-370 V DC Frequency range AC 47-63 Hz Typical input current at 115 V AC 2.8 A at 230 V AC 1.4 A Typical power consumption 143 W Inrush current at 115 V AC 24 A (max. 5 ms) at 230 V AC 48 A (max. 5 ms) Power failure buffering at 115 V AC min. 25 ms at 230 V AC min. 30 ms Internal input fuse 3.15 A slow-acting / 250 V AC Indication of operational states Output voltage OUTPUT OK: green LED V: output voltage OK OUTPUT LOW: red LED V: output voltage too low Output circuit L+, L+, L-, L- Rated output voltage 12 V DC Tolerance of the output voltage 0...+1 % Adjustment range of the output voltage 11.4-14.5 V DC Rated output power 120 W Rated output current I r T a 60 C 10 A Derating of the output current 60 C < T a 70 C 2.5 %/ C Maximum deviation with 1 % (single mode) load change statical 5 % (parallel mode) change of input voltage within the input voltage range 0.5 % Control time < 2 ms Starting time after applying the supply voltage at I r max. 1 s Response time at rated load Residual ripple and switching peaks BW = 20 MHz 50 mv Parallel connection configurable, to increase power, up to 3 devices, reduction: (number of devices x I r x) x 0.9 Series connection yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 22 V DC Power factor correction (PFC) yes Output circuit - No-load, overload and short-circuit behaviour Output curve U/I curve Short-circuit protection continuous short-circuit proof Short-circuit behaviour continuation with output power limitation Overload protection output power limitation No-load protection continuous no-load stability Starting of capacitive loads unlimited 4

Type CP-E 12/10.0 Gerneral data Efficiency typ. 84 % Duty time 100 % Dimensions (W x H x D) 63.2 x 123.6 x 123.6 mm [2.49 x 4.87 x 4.87 in] Weight 1 kg (2.20 lb) Material of enclosure Metall Mounting DIN rail (EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.98 in / 0.98 in) Degree of protection enclosure / terminals IP20 / IP20 Protection class I Electrical connection - input circuit / output circuit Wire size fi ne-strand with wire end ferrule 0.2-4 mm² (24-11 AWG) fi ne-strand without wire end ferrule rigid 0.2-6 mm² (24-10 AWG) Stripping length 8 mm (0.31 in) Tightening torque input / output 1 Nm / 0.6 Nm Environmental data Ambient temperature range operation -25 +70 C rated load -25...+60 C storage -25 +85 C Damp heat (cyclic) (IEC/EN 60068-2-30) 95 % without condensation Vibration (sinusoidal) (IEC/EN 60068-2-6) Shock (half-sine) (IEC/EN 60068-2-27) Isolation data Rated insulation voltage U i input circuit / output circuit 3 kv AC Pollution degree 2 Standards Product standard Low Voltage Directive 2006/95/EG EMC directive 2004/108/EG RoHS directive 2002/95/EG Electrical safety IEC/EN 60950-1 Protective low voltage SELV Electromagnetic compatibility Interference immunity IEC/EN 61000-6-2 electrostatic discharge (ESD) IEC/EN 61000-4-2 electromagnetic field (HF radiation resistance) IEC/EN 61000-4-3 fast transients (Burst) IEC/EN 61000-4-4 powerful impulses (Surge) IEC/EN 61000-4-5 HF line emission IEC/EN 61000-4-6 Interference emission IEC/EN 61000-6-3 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 5

Technical diagrams Output behaviour Uout [V] 14 12 10 8 6 4 2 2 4 6 8 10 12 14 16 Iout [A] 2CDC 272 005 F0b08 Output curve at T a = 25 C The switch mode power supply CP-E 12/10.0 is able to supply at 12 V DC output voltage and at an ambient temperature of: 60 C a continuous output current of approx. 10 A at ambient temperatures of: 60 C < T a 70 C the output power has to be reduced by 2.5 % per C temperature increase. If the switch mode power supply is loaded with an output current > 10 A, the operating point is passing through the U/I characteristic curve shown. Temperature behaviour Pout [%] 100 90 80 70 60 50 40 30 20 10-25 60 70 Ta [ C] 2CDC 272 011 F0208 Temperature curve at rated load Dimensions in mm 123,6 [4.87 ] 63,2 [2.49 ] 116,6 [4.59 ] 123,6 [4.87 ] 2CDC 272 002 F0b08 CP-E 12/10.0 6

Dimensions accessories in mm 144,5 [5.69 ] 60,0 [2.36 ] 137,0 [5.39 ] 56,5 [2.22 ] 130,0 [5.12 ] 135,5 [5.33 ] 2CDC 272 015 F0b07 CP-A RU Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x Power Supply Units Application manual 2CDC 114 048 M020x Redundancy unit CP-A RU 2CDC 114 036 D0202 You can find the documentation in the internet under www.abb.com/lowvoltage Control Products... 7

ABB STOTZ-KONTAKT GmbH As part of the on-going product improvement, ABB reserves the right to modify the characteristics of the products described in this document. The information given is non-contractual. For further details please contact (www.abb.com/contacts) the ABB company marketing these products in your country. Document number: 2CDC 114 059 D0201 (07/2008) Eppelheimer Strasse 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage Control Products Contact: http://www.abb.com/contacts Low Voltage Products and Systems