Suspension System Technical Guide Data Center Ceiling Solutions

Similar documents
XL MAX. Suspension System Data Center Ceiling Solutions. Assembly and Installation Instructions

ULTIMA Create! Custom Images CEILING SYSTEMS. Between us, ideas become reality. ULTIMA Create! Custom Colors and Images

DESIGN. durable metal mesh panels. Intertwine Your

Design. durable metal mesh panels. Intertwine Your

METALWORKS Concealed. Installation Instructions

DESIGN. durable metal mesh panels. Intertwine Your

METALWORKS Mesh. intertwine your design

METALWORKS Linear (Interior & Exterior Applications)

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. International Version

METALWORKS Linear (Interior & Exterior Applications)

FORMATIONS Curves Clouds with AXIOM VECTOR Trim and Suspension System

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

METALWORKS Linear (Interior & Exterior Applications)

AXIOM Classic Trim. Assembly and Installation Instructions

AXIOM Classic Trim. Assembly and Installation Instructions 1. GENERAL

AXIOM Classic Trim Installation Instructions

metalworks Vector Assembly and Installation Instructions

DesignFlex Shapes Lyra, Calla, Optima, Ultima Panels

WOODWORKS. Linear Solid Panels. Installation Instructions CEILING SYSTEMS. 1. General

Soundscapes Shapes Acoustical Clouds

Trim (Aluminum Substrate)

friendly WOODWORKS Concealed Concealed Suspension Natural Variations, Constants, and Bamboo cloud KEY SELECTION ATTRIBUTES

METALWORKS TARTAN PANELS General Installation Instructions

WOODWORKS Concealed. Assembly and Installation Instructions

WOODWORKS Access Hook-on System

Classic Exposed Tee System (24" x 24", 24" x 48", and 24" x 72") Floating Clouds and Perimeter Wall Attachment

WOODWORKS Grille System

product family TechZone available with Optima, Ultima, MetalWorks and WoodWorks panels

WOODWORKS Linear Solid Panels

WOODWORKS Linear Solid Panels

ON-CENTER LINEAR LIGHTING WITH XAL Layout Guide

WoodWORKS Channeled Plank

Acoustical Infill Panels

INFUSIONS and METALWORKS Wings Accent and Acoustical Clouds

INTERIOR INSTALLATION

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

AUXILIARY FRAMING AND ACCESSORIES

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

Light Structural Main Runner Light Structural Infill Tees. Straight Connector. Strut Structural Tee thread

MPA-9000 Universal Ceiling Projector Mount Kit

CARRIER OVERHANG 1'-0" MAX PANEL LENGTH 3'-0" MIN - 16'-0" MAX (RECOMMENDED) SPECIFICATIONS (unless noted otherwise)

southpaw enterprises, inc.

Technical Data VARIABLES

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

Rayport G Eco Dealer Kit

Tools needed. Supplies Needed

METALWORKS Wings Accent and Acoustical Clouds Installation Instructions

Installation Guide 888-4WB TRAY

TECHZONE Ceiling Systems Selection Guide

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

southpaw enterprises, inc.

CEILING-MOUNTED MONORAIL ANCHOR TRACK SYSTEM Assembly and Operation Instruction Manual

ARMSTRONG METALWORKS BAFFLES Installation Guide

SolarMount (E)volution

APPENDIX A, UMC STANDARD 6-5 STANDARD FOR INSTALLATION OF FACTORY-MADE AIR DUCTS

Technical Data VARIABLES

Horizontal Array Bracket Installation Instructions

STRUCTURAL ATTACHMENTS

Manually adjustable blades Return air VAV cooling only VAV cooling and warm up heating TF-D TF-RA TB-C TB-CW

Beam and Purlin Clamps Beam Clamps

Slice. pat e n t p e n d i n g 2

Hospital Grade Welded Ceiling System

Superstrut Stainless Steel Channels and Accessories

Technical Data VARIABLES

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Hang-TITE Rod Hanger Screws

ASSORTMENTS BRONZECLASSWB Above assortment with one #99901 Cabinet, 17 extra dividers, all drawers pre-labeld inside and out.

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Swell. pat e n t p e n d i n g

REPORT HOLDER: INTERCORP DBA OF U.S. NITTO 641 NORTH POPLAR ORANGE, CALIFORNIA EVALUATION SUBJECT: STRONG POINT SCREWS

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

Product Guide Specification

Panel Grille Suspended Ceiling Installation Guide

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

How to Install the QuickHang Installation Kit

H DIMMING QS 0-10 V 1 % 2. RadioRA 2. Hi-lume 1 %, EcoSystem COLOR TEMPERATURE 3000 K / CRI > 80 5 QS 3500 K / CRI > K / CRI > 80 6

CI/SfB. October RockLink Integra. Installation system

Shearwall System Installation Guide

Inde-Pendants Family. 32L Surface Mount Cylinder Plaster Trim, Grid and Drywall Ceiling Types. Document No

Inc. BT Series. BW Series

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

Open Up Your View With CABLE SYSTEMS

UL 580 Construction No: ½ in Snap Lock w/ Clip

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

March 1, Fax:

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Installation Guide [OPTION B] MODEL # PRM4X8 Patent Pending

WOODWORKS Linear. Veneered Planks, Panels, Solid Wood Panels

Face Mount to Through-the-Post Mount

UL 580 Construction No: ½ in Mechanical Lock w/ Clip

Diva Acoustical Ceiling

CRASH RAIL INSTALLATION HEIGHT

Installation Guide. Overview

The Festival Assembly Instructions

KS SERIES - VERTICAL INSTALLATION

T-GRID SYSTEM WIDE CLEANROOM CEILING GRID SYSTEM

Wire Mesh Cable Tray System for Channeling of Cable Wiring

Box Edge Plus Steel Shelving Installation Instructions

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

Transcription:

Prelude xl Max Suspension System Technical Guide Data Center Ceiling Solutions For more information, call 1 877 ARMSTRONG 1

technical guide The Prelude XL Max suspension system for data center applications is a pre-engineered ceiling suspension system designed for improved air flow management, load carrying capacity, and adaptability in data centers of all sizes. The Prelude XL Max suspension system uses 3/8 inch threaded rod support and reconfigurable load connector clips to support cable trays, bus bars, and other components to provide maximum load carrying capacity and flexibility, while eliminating the need for a separate strut channel suspension system. Code Compliance You Can Trust Suspension system meets: ASTM C635 ASTM C636 ASTM E580 ICC-ES AC156 Seismic D, E, F configurations available Key Selection Attributes Prelude XL Max Suspension System Supports load from the face utilizing 3/8" threaded rod and integrated hanging clips to provide: Flexible and reconfigurable overhead cable tray and electrical distribution to meet client needs without a separate strut channel system. Eliminates unsightly threaded rod penetrations through the ceiling plane for improved access and aesthetics Reduced ceiling penetrations help minimize unwanted air infiltration 2 For more information, call 1 877 ARMSTRONG

Table of Contents 2 Code Compliance 2 Performance 4 How the System Works 5 Suspension System Components 6 Recommended Ceiling Panels 7 Installation Overview and Hardware 8 Installation/Layout Overview and Seismic Data 9 Point Load Data Center and Mid Point 10 Point Load Data Single and Dual Point Connection and Seismic Data Prelude XL Max suspension system with Ultima ceiling panels Prelude xl Max For more information, call 1 877 ARMSTRONG 3

how it works IHC Intersection Hanging Clip Used to increase main beam to cross tee connection strength and carry the ceiling system with 3/8" threaded rod from structure PMLC Prelude XL Max Load Connector Used to support bus bars, cable trays, and other components with 3/8" threaded rod along the suspension system face For additional information and technical guidelines, contact TechLine SM at 1 877 ARMSTRONG and select prompts 1-2-3. 3/8" threaded rod to structure (4' O.C. or as required) 2 3 Main Beam 6" Max Cross Tee Cable Tray (By others) Prelude XL Max Main Beams and Cross Tees face double bulb suspension system provides maximum load carrying capacity and Seismic D, E, F performance IJC Intersection Joint Clip Used when supporting load from a cross tee that isn t supported on both sides with the Intersection Hanging Clip SHC Supplemental Hanging Clip Used to carry the ceiling system with 3/8" threaded rod from any route location along the main beam when plenum obstructions prevent use of the IHC Clip TLMBS Top SHC Supplemental H Lock Main Beam Splice Clip Locks two main beams together for a secure connection. * Must be within 6" of an IHC or SHC 4 For more information, call 1 877 ARmSTRONG

suspension system components Item No. Face Profile Description Dimensions (Inches) Key Selection Attributes Prelude XL Max Suspension System 2' x 2' suspension system supports load from the face of the suspension system using 3/8" threaded rod and integrated hanging clips to provide: - Flexible and reconfigurable overhead cable tray and electrical distribution to meet client needs without a separate strut channel system - Eliminates unsightly threaded rod penetrations through the ceiling plane for improved access and aesthetics - Reduced ceiling penetrations help minimize unwanted air infiltration Hanger Spacing* Lbs./Lin. Ft. Fire Guard Seismic Category Prelude XL Max 4 Ft. Dots represent high level of performance. Scan here to watch the installation video Suspension system meets ASTM C635, ASTM C636, ASTM E580, ICC-ES AC156 with Seismic D, E, F available Custom colors available to coordinate with Ultima Create! ceiling panels Factory applied gasket option available 30-Year Limited System Warranty Visual SeleCTION performance Packaging 730145 12' HD Main Beam 144 x 15/16 x 2.44" 40.17 10 120 XL7345 4' Cross Tee 48 x 15/16 x 2.44" 40.17 30 120 XL7325 2' Cross Tee 24 x 15/16 x 2.44" 30 60 Pcs./ Ctn. Lin. Ft./ Ctn. Molding SWA9878HRC 7/8" 12' Structural Wall Angle 144 x 7/8 x 7/8" 12 144 * Simple Span Uniform Load accessories IHC Intersection Hanging Clip Used to increase main beam to cross tee connection strength and carry the ceiling system with 3/8" threaded rod from structure. * Steel rivets not included IHC 160 pcs FZIHC 50 pcs PMLC Prelude XL Max Load Connector Used to support bus bars, cable trays, and other components with 3/8" threaded rod along the suspension system face. PMLC 100 pcs FZPMLC 50 pcs IJC Intersection Joint Clip Used at all cross tee-to-cross tee or main beam-to-cross tee connections not using an IHC Clip. * Machine screws included IJC 250 pcs FZIJC 50 pcs XTAC Cross Tee Adapter Clip Securely attaches cross tees or main beams to the structural wall molding around the perimeter of the ceiling installation. XTAC 100 pcs FZXTAC 50 pcs SHC Supplemental Hanging Clip Used to carry the ceiling system with 3/8" threaded rod from any location along the main beam when plenum obstructions prevent use of the IHC Clip. * Machine screws included SHC 144 pcs FZSHC 50 pcs TLMBS Top Lock Main Beam Splice Clip Locks two main beams together for a secure connection. 10 pcs (included with item 730145 Main Beam) FZTLMBS 50 pcs PMHDC Prelude XL Max Hold Down Clip Attaches to the top bulb of the Prelude XL Max suspension system to hold ceiling panels in place; helps to prevent ceiling panel movement. PMHDC 100 pcs FZPMHDC 50 pcs details Color Selection Due to printing limitations, shade may vary from actual product. 7/8" (22mm) 7/8" Structural Wall Angle 2-11/25" (62mm) Prelude XL Max Main Beam & Cross Tee White (WH) RAL Colors Custom Colors White is standard color for main beams and cross tees. All clips are unfinished. Custom colors and finishes are available for main beams, cross tees, and load connector clips to coordinate with Create! ceiling panels and custom project colors. Contact Armstrong Customer Service 1 877 276 7876 7/8" (22mm) (24mm) For more information, call 1 877 ARmSTRONG 5

recommended ceiling panels Ultima Smooth, clean, durable finish Impact-resistant, Scratch-resistant, and Soil-resistant; safe for use with disinfectants Long-lasting water-repellency; Washable and Scrubbable Excellent sound absorption 30-Year Limited System Warranty against visible sag and mold/mildew Ultima CreATe! Create! panels are available in over 100 standard colors or any custom color! Digitally design your own original artwork and place your vision onto the ceiling plane in your design Suspension and Axiom perimeter trim options available in coordinating standard and custom colors Excellent sound absorption NRC 0.70 0.90 Product is directional Custom samples available Clean Room FL/VL Clean Rooms up to ISO Class 5 (Class 100) Durable Washable, Scrubbable, Soil-resistant Non-directional visual reduces installation time and scrap 30-Year Limited System Warranty against visible sag and mold/mildew Selected square lay-in Ceiling panels for DATA Center AppLICATIONS performance Dots represent high level of performance. Edge Profile Ultima Square Lay-in Item No. Dimensions (Inches) 1935* 24 x 24 x 3/4" 0.70 Acoustics Fire Rating Light Reflect Anti-Mold & Mildew Sag Resist UL Classified BioBlock+ Guard+ Humi- 38 Class A 0.86 Certified Low VOC Emissions Durability Water Repel Wash Scrub Impact Scratch Soil Primary (Embodied) Energy Below 11MJ/SF Recycled Content Recycle Program High 30 Yes Warranty No. of Years Beveled Tegular 1937 24 x 24 x 3/4" 0.70 38 Class A 0.86 High 30 Ultima Create! Square Lay-in Square Lay-in Z1935UC1 24 x 24 x 3/4" 0.70 38 Class A High 30 Clean Room FL Field Panel Class 5 (Class 100) Square Lay-in 1715 24 x 24 x 3/4" 0.55 35 Class A 0.79 High 30 Clean Room FL Border Panel Class 5 (Class 100) Square Lay-in 1720 24 x 24 x 5/8" N/A 35 Class A 0.79 Std 30 Clean Room VL Unperforated Class 5 (Class 100) Square Lay-in 868 24 x 24 x 5/8" N/A 40 Fire Guard 0.80 Std 30 * Create! colors available on item 1935 Item does not have painted edges Based on image/color coverage, NRC may vary slightly. Add two-letter color suffix to item when specifying or ordering standard Wood Looks items (e.g., Z1935UC1 L C). 6 For more information, call 1 877 ARMSTRONG

installation overview and hardware overview: Five Easy Installation Steps 1. Install threaded rod to deck 2. Slide the IHC onto main beam and attach to threaded rod. Splice not more than 6" from rod 3. Snap in cross tees and rivet the connection 4. Slide on and secure the load connectors 5. Screw attach load connectors #8 X 1/2" L (Min.) Sharp Point Truss #8 X 1/2" L (Min.) Head Screw Sharp Point Truss Head Screw Hex Locknuts Grade 2, 11/16" 3/8-16 Width, 35/64" Height Hex (MSC Locknuts Item #52592839) Grade 2, 11/16" Width, 35/64" Height (MSC Item #52592839) Hex Nuts ANSI/ASME B18.2.2, Grade 3/8-16 2, 11/16" Width, 23/64" Height Hex (MSC Nuts Item ANSI/ASME #87921425) B18.2.2, Grade 2, 11/16" Width, 23/64" Height 3/8"-16 Threaded Rod Low-strength Steel 3/8"-16 Threaded Rod Low-strength Prelude Steel XL Max PMLC Prelude XL Max Load Connector Suspension System PMLC Prelude XL Max Load Connector Prelude XL Max Load Connector (PMLC) Intersection Hanging Clip (IHC) IMPORTANT: Connections for load-carrying grid form a structural element. Please take time to understand and follow installation instructions to ensure rated load performance. IHC 160 pcs FZIHC 50 pcs Supplemental Hanging Clip (SHC) (MSC Hex Item Locknuts #52592839) Grade 2, 11/16" Width, 35/64" Height (MSC Item #52592839) Hex Nuts ANSI/ASME B18.2.2, Grade 2, 11/16" 3/8-16 Width, 23/64" Height Hex Nuts ANSI/ASME B18.2.2, Grade 2, 11/16" Width, 23/64" Height 3/8"-16 Threaded Rod Low-strength 3/8"-16 Steel Threaded Rod Low-strength Steel PMLC Prelude XL Max Load Connector PMLC Prelude XL Max Load Connector 3/8" Threaded Rod Low-strength 3/8" Steel Threaded Rod Low-strength Steel Hex Nuts ANSI/ASME B18.2.2, Grade 2, 11/16" 3/8-16 Width, 23/64" Hex Height Nuts ANSI/ASME B18.2.2, (MSC Grade Item 2, #87921425) 11/16" Width, 23/64" Height (MSC 3/8-16 Item #87921425) Hex Locknuts Grade 2, 11/16" Width, 3/8-16 35/64" Height (MSC Hex Item Locknuts #52592839) Grade 2, 11/16" Width, 35/64" Height (MSC Item #52592839) Blind Steel Pop Rivets 1/8" Dia. x.337" Blind Long Steel.126" Pop.186" Rivets Grip Range Shear 1/8" Strength: Dia. x.337" 260 lbs. Long IFI 114 Grade 30.126".186" Grip Range Size Code 43 Shear Strength: 260 lbs. IJC - Intersection (MSC Joint Item #76811066) IFI 114 Clip IJC - Intersection Joint Clip Grade 30 IHC Intersection Hanging Clip Size Code 43 (MSC Item #76811066) IHC Intersection Hanging Clip M #8 # Tr T 2'/ 2 PMLC 100 pcs FZPMLC 50 pcs Intersection Joint Clip (IJC) IJC 250 pcs FZIJC 50 pcs Intersection Joint Clip #8 #8 X 1/2" X 1/2" L (Min.) L (Min.) Sharp Sharp Point Point Truss Truss Head Head Screw Screw Hex Hex Locknuts Grade Grade 2, 2, 11/16" Width, Width, 35/64" 35/64" Height Height (MSC (MSC Item Item #52592839) 3/8-16 3/8-16 Hex Hex Nuts Nuts ANSI/ASME ANSI/ASME B18.2.2, B18.2.2, Grade 2, 11/16" Width, 23/64" Height Grade 2, 11/16" Width, 23/64" Height 3/8"-16 Threaded IJC - Intersection Rod Joint Low-strength Clip3/8"-16 Steel Threaded Rod Low-strength Steel PMLC Prelude XL Max Load Connector PMLC Prelude IJC - Intersection XL Max Load Joint Connector Clip Supplemental Hanging Clip (SHC) 3/8" Threaded Rod Low-strength Steel Hex Nuts 3/8" ANSI/ASME Threaded Rod B18.2.2, Low-strength Grade 2, 11/16" Steel Width, 23/64" Height Hex Nuts ANSI/ASME 3/8" Flat Washer, B18.2.2, 1/8" Thickness, 7/8" Width, Grade 2, 11/16" Width, Case Hardened Steel, 23/64" Height Grade C-1010 (MSC (MSC Item Item #87921425) #74213505) 3/8" Flat Washer, 1/8" Thickness, 3/8-16 7/8" Width, Hex Locknuts Grade 2, Case Hardened Metric: M5 Steel, 11/16" Width, 35/64" x 6mm, Height 0.8mm Grade C-1010 (MSC Item Pitch #52592839) Pan Head Machine (MSC Item Screw #74213505) DIN 7985; ISO 7045, Grade 4.8 Phillips Drive Metric: (MSC M5 3/8-16 x 6mm, Item #09169418) 0.8mm Pitch Pan * Apply Head Threadlocker Hex Locknuts Machine Screw DIN Blue 7985; 242 Grade ISO or 7045, Similiar 2, 11/16" Width, 35/64" Height (MSC Grade Item 4.8 Phillips #52592839) Drive (MSC Item #09169418) IJC - Intersection * Apply Threadlocker Joint Clip Metric: Blue M5 242 x or 6mm, Similiar 0.8mm Pitch Pan Head Machine IJC - Intersection Joint Clip Screw DIN 7985; ISO 7045, Grade 4.8 Phillips Drive *Hardware included Supplemental Hanging Clip (SHC) (MSC Item #09169418) * Apply Threadlocker Blue 242 or Similiar 3/8" Threaded Rod Low-strength Steel 3/8" Threaded Rod Low-strength 3/8-16 Steel Hex Nuts ANSI/ASME B18.2.2, 3/8" Threaded Rod Low-strength 3/8" Threaded Steel Rod Low-strength Steel 3/8" Threaded Rod 3/8" Threaded Rod Low-strength Low-strength Steel Steel Main Beam/4' Cross Tee Hex Nuts 3/8-16 ANSI/ASME B18.2.2, Hex Grade Nuts 2, ANSI/ASME 11/16" Width, 3/8-16 B18.2.2, 3/8-16 Main Beam/4' Cross Tee Grade 23/64" 2, 11/16" Height Hex Nuts Width, Hex ANSI/ASME Nuts ANSI/ASME B18.2.2, B18.2.2, 23/64" Height Grade 2, Grade 11/16" 2, Width, 11/16" Width, (MSC Item 23/64" #87921425) 3/8" Flat Height 23/64" Washer, Height 1/8" Thickness, (MSC Item 7/8" (MSC #87921425) Width, Item #87921425) #8 x 1/2" L Sharp Point Case Hardened 3/8" Flat Washer, Steel, Truss Head Screws: Quantity 3 1/8" Grade Thickness, C-1010 7/8" 3/8-16 Width, 3/8-16 Case (MSC Hardened Item Hex #74213505) Locknuts Steel, Hex Locknuts Grade 2, Grade 2, Grade C-1010 11/16" Width, 11/16" 35/64" Width, Height 35/64" Height #8 x 1/2" L Sharp Point 2'/4' Cross Tee (MSC (MSC Item (MSC #52592839) Item #52592839) Truss Head Screws: Quantity 3 Item #74213505) 3/8-16 Hex Locknuts Grade 2, 11/16" 3/8-16 Width, 35/64" Height Hex (MSC Locknuts Item #52592839) Grade 2, 2'/4' Cross Tee Blind Steel 11/16" Width, 35/64" Height Blind Steel Pop Rivets (MSC Item Pop Rivets Metric: M5 1/8" #52592839) x 6mm, Dia. x 0.8mm.337" Long.126".186" 1/8" Grip Dia. Range x.337" Long Pitch Pan Head Machine Shear Strength:.126" 260.186" lbs. Grip Range Metric: Screw M5 DIN x 6mm, 7985; 0.8mm ISO 7045, IFI 114 Grade Shear 30Strength: 260 lbs. Pitch Grade Pan Head 4.8 Phillips Machine Drive (MSC Item Size #09169418) Code IFI 43114 Grade 30 Screw DIN 7985; ISO * Apply Threadlocker (MSC Item Size 7045, #76811066) Code 43 Grade 4.8 Phillips Drive Blue 242 or Similiar (MSC Item #76811066) IHC Intersection (MSC Hanging Item Clip #09169418) IHC Intersection * Apply Threadlocker SHC 144 pcs Hanging Clip Blue 242 or Similiar FZSHC 50 pcs * Machine screws included Supplemental Hanging Clip (SHC) Supplemental Hanging Clip (SHC) Top Lock Main Beam Splice (TLMBS) IMPORTANT: Rivets are properly installed when the compressed Main Beam/4' Cross rivet Tee body protrudes a minimum of 1/8" Main Beam/4' past the Cross IHC Tee or TLMBS surface. #8 x 1/2" L Sharp Point Truss Head Screws: Quantity 3 #8 x 1/2" L Sharp Point Truss Threaded Head Screws: Rod to Quantity Structure 3 2'/4' Cross Tee (2) #8 x 1/2" long 2'/4' Cross Tee Sharp Point Truss Head Screws Max 6" Top Lock Main Beam Splice Clip Blind Steel Pop Rivets 1/8" dia. x.337" long.126".186" Grip Range Shear Strength: 260 lbs. For more information, call 1 877 ARMSTRONG 7

Fixed Wall 12' 12' installation and layout overview 12' 12' Float Wall LSB Symbol Key: Fixed Wall Intersection Joint Clip (IJC) Cross Tee-to- Cross Tee Intersection Hanging Clip (IHC) Main Beam-to- Cross Tee Cross Tee Adapter Clip (XTAL) Fixed Wall Molding Condition Lateral Support Bar (LSB) Float Wall Molding Condition * note: For seismic only, two floating walls required Seismic Data Seismic information IBC categories D, E and F must also meet these additional requirements: Structural wall angle is to be used along the perimeter with a XTAC clip attaching the grid to the angle molding, as directed in section 2. Grid must be attached to two adjacent walls opposite walls must have a 3/4 clearance in accordance with ASTM E580. Ends of main beams and cross tees must be tied together to prevent their spreading. These should be locked into place using the lateral support bar. Ultra -duty grid system. See load data. Ceiling areas over 1,000 SF must have standard rigid bracing for the grid. Ceiling areas over 2,500 SF must have seismic separation joints or full height partitions. Ceilings without rigid bracing must have 2 oversized trim rings for sprinklers and other penetrations. Changes in ceiling plane must have positive bracing. Mechanicals (Cable trays, electrical, etc) may be attached and supported by the ceiling grid, per our instructions. However, mechanicals must be seismically braced by others. Suspended ceilings will be subject to special inspection. Perimeter support wires within 8. NOTE: Consult your local code professional for information specific to your region. California projects may be governed by DSA and OSHPD. 8 For more information, call 1 877 ARMSTRONG

point load data prelude XL max load connector Center Point Loads Center Point load information (lbs.) Hanger Spacing Item No. 2 Ft 3 Ft 4 Ft 5 Ft 6 Ft 7 Ft 730145 120.1** 93** 67.3** 58.2** 42.3** XL7345 93** XL7325 119.06** prelude XL max load connector Mid Point Loads Main Beam, 4' Span Cross Tee, 4' Span 48" (Span) 24" 48" (Span) 24" Max mid span load = 93 lbs** Max point load within 3" of threaded rod = 300 lbs** Max mid span load = 93 lbs** Max point load within 3" of threaded rod = 300 lbs** ** Values are not valid when a TLMBS is within the span. NOTES: These values are based on the spans being installed in a 2' x 2' module (using a 2' tee). Unbraced or 2' x 4' modules will have a lower mid span load value. General Loading information: For main beams and 4' cross tees directly connected to an IHC clip with rod to deck, total load for any 4' span not to exceed 93 lbs. Note: This is the minimum load performance. See following pages for additional allowable loading conditions. If higher loads are required, contact Techline for guidance and a qualified engineering professional. For more information, call 1 877 ARMSTRONG 9

The expanded IHC Intersection Hanging Clip Installation on the IHC clip. Load Connector C 3/8 16" Threaded Rod 3 2 1 Single Point Connection.126".186" Grip Length Shear Strength: 260 lbs. on the IHC clip. rivet goes through the XL Clip. Make sure that the head of the Blind Steel Pop Rivets 1/8" Dia. x.337" Long TLMBS Top Lock Main Beam Splice Clip Splice Clip on two Prelude XL Max Main Beams Top Lock Main Beam Splice Clip Installation Head Screws Load Connector C 3 2 1 PMLC Clip Screw Sharp Point Truss Head IJC Inter Point Load Data Prelude XL Max Load Connector (PMLC) PMLC Load Connector Clip Cable Tray (By others) See manufacturer of cable tray for the recommendation of seismic bracing for the cable tray IHC Intersection Hanging Clip Installation portion of the rivet needs to expand Dual Point Connection 3/8 16" Threaded Rod Cable Tray Insatll Single Point SYMBOL KEY: Cable Tray (By others) See manufacturer of cable tray for the recommendation of seismic bracing for the cable tray Prelude Max Load Connector Prelude XL Max Load Connector (PMLC) Cable Tray PMLC Load Connector Clip 10 For more information, call 1 877 ARMSTRONG

take the next step 1 877 ARMSTRONG (276-7876) Customer Service Representatives 7:45 a.m. to 5:00 p.m. EST Monday through Friday TechLine SM Technical information, detail drawings, installation information, other technical services 8 a.m. to 5:30 p.m. EST, Monday through Friday. FAX 1 800 572 8324 or email: techline@armstrong.com armstrongceilings.com/commceilings Latest product news Standard and custom product information Online catalog CAD, Revit, SketchUp files A Ceiling for Every Space Visual Selection Tool Product literature and samples express service or regular delivery Contacts reps, where to buy, who will install You Inspire Solutions Center 1 800 988 2585 email: solutionscenter@armstrong.com armstrong.com/youinspire Design Assistance Collaborative design Detail drawings Specifications Planning and budgeting Pre-construction Assistance Layout drawings for standard and premium products Project installation recommendations Contractor installation assistance helping to bring your one-of-a-kind ideas to life SketchUp is a registered trademark of Trimble Navigation Limited; Revit is a registered trademark of Autodesk, Inc.; RAL is a registered trademark of RAL ggmbh. All other trademarks used herein are the property of AWI Licensing LLC and/or its affiliates 2016 AWI Licensing LLC Printed in the United States of America armstrongceilings.com/datacenters BPCS-4934-616