Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Similar documents
Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Analog Universal Module HART for Zone 2 Series 9468/33

Temperature Input Module for Zone 1 Series 9482/32

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Isolating Repeater Input Series 9163

Binary Output Series 9175

Isolators A3/1.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Binary Output without Power Supply Series 9176

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Vibration Transducer Supply Unit Series

Remote I/O. 74 Remote I/O. Remote I/O System

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Digital I/O Coupler (4-wire) Series 9413/21

Fieldbus Isolating Repeater Series 9185/11

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Two-channel safety barriers Series 9002

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Two-channel safety barriers Series 9002

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Single-Channel Safety Barriers Series 9001

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Technical Data. General specifications. Rated operating distance s n 3 mm

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Inductive sensor slot-type SI2-K08-AP7

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Assembly. Front view. Switch Power Rail

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

Technical Information Barrier RB223

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Assembly. Front view. Switch Power Rail

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Actuators Series 8602/3

Assembly. Front view. Parametrization interface. Power Bus

Signal conditioner - MACX MCR-UI-UI-NC

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

Pulse Scaler for DIN Rail Attachment

DeltaV SIS Logic Solver

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information

Temperature transmitter itemp PCP DIN rail TMT 121

Rail mounted Temperature Transmitter TH102/TH102-Ex

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature Transmitter itemp RTD DIN rail TMT 127

Motor Protection Circuit Breaker Series 8146/5-V27

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Signal Beacon - LED Series 6162

Control Unit Series 8208

INSTRUCTION MANUAL (ATEX / IECEx)

Rotary Measuring Technology

Railbus isolator. Railbus isolator 8922-RB-IS

PRetrans Table of contents

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

SINEAX TV809, 1 channel Programmable Isolating Amplifier

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Head mounted Temperature Transmitter TF02/TF02-Ex

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Operating Manual. isolate501

Preset counters, electronic

itemp HART DIN rail TMT112

A6500-UM Universal Measurement Card

Local control stations for Zone 1 and Zone 21. Features. Description

Type CP-S, CP-C & CP-A Switch mode

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Level Limit Switch nivotester FTL 325 P

Field indicator for current loops with HART communication Models DIH50, DIH52

Type Nominal voltage (V) Code HSV V

CP-T range Product group picture

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

PHOENIX CONTACT - 09/2009

Technical Information RMA42

Rudder or propeller angular position transmitter KINAX WT720

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Operating Instructions

SINEAX TI 807 Passive DC signal isolator

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

CP-T range Benefits and advantages

SISNet Repeater. SISNet Repeater. Introduction. DeltaV SIS Product Data Sheet. Dedicated safety communications. Full communications redundancy

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Transcription:

www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up to 8 channels can be used as frequency/counter inputs; with rotation direction recognition > Line fault monitoring > LED display for signal and errors for each channel > Additional control input for "Plant STOP" (in accordance with IEC 61508 up to SIL2) > Energized module can be replaced in hazardous areas (hot swap) > Function-compatible replacement for IS1 I/O modules: 9470/25 and 9471/15 series 17616E00 The 24 V digital input output module can connect up to 16 non-intrinsically safe digital signals to the IS1+ remote I/O system. All channels can be configured as inputs for NAMUR proximity switches (EN 60947-5-6), 3-wire PNP proximity switches (with a 24 V supply) as well as for passive contacts and for solenoid valves (24 V / 0.5 A) (in pairs with adjustable parameters). The external power supply for 3-wire proximity switches and solenoid valves comes from a separate terminal on the front side of the module. Up to 8 inputs can be used as frequency inputs or as counters up to 20 khz. In the "rotation direction recognition" and "forward/backward counter" operating modes, it is up to 4 inputs. An additional "Plant STOP" control input on the front side of the module is used to safely switch off all outputs. All inputs and outputs are monitored for short circuiting and line breakage. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x WebCode 9472A Remote I/O /1

Selection Table Version Description Installation Order number Weight kg Digital input 16 channels with adjustable parameters Zone 2, 22 and 9472/35-16-12 0.275 output module 24 V, for NAMUR proximity switches / contacts, safe area 3-wire PNP proximity switches with 24 V power supply, solenoid valves (24 V / 0.5 A), with channel status LEDs and "Plant STOP" Note Order 2 terminals separately - see Accessories This module is not supported by the Ethernet CPU 9441! Explosion Protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Certifications and certificates Certificates Ship approval Further parameters Installation Further information Ex ec [Ex ia Ga] IIC T4 Gc [Ex ia IIIC Da] E II 3 (1) G Ex ec [Ex ia Ga] IIC T4 Gc E II (1) D [Ex ia IIIC Da] IECEx, ATEX In progress Zone 2, 22 and safe area see respective certifcate and operating instructions Electrical data Ex n inputs / outputs Number of channels 16 (in pairs with adjustable parameters as input or output) Ex n inputs Max. number of channels 16 Min. ON input signal 2.1 ma Max. OFF input signal 1.2 ma Switching threshold 1.65 ma Supply voltage 8.0 V ± 5% Internal resistance 1 k Ω Signal IEC 60947-5-6-1999 (NAMUR) or 3-wire PNP proximity switches with and without 10 kω / 47 kω resistance connected in parallel Frequency input Max. number of channels 8 Max. switching frequency NAMUR input: 20 khz (at frequencies > 1 khz the maximum conductor length is reduced, e.g. at 5 khz to approx. 75 m) 3-wire PNP proximity switches: ( 500 Hz Min. pulse width NAMUR input: 25 μs 3-wire PNP proximity switches: 1 ms Measuring range 1 Hz... 1 khz 1 Hz... 20 khz Resolution 0.05 Hz 1 Hz Accuracy 0.02% 0.02% Counter Max. number of channels 8 Counter range 0... 65536 Rotation direction recognition, forward/backward counter Max. number of channels 4 (each with two inputs switched in parallel) Function Up/down counter; frequency with direction Resolution 16 bit / 32 bit /2 Remote I/O

Electrical data Ex n inputs / outputs Ex n outputs Max. number of channels 16 Output voltage U H -0.5 V Output current 5 ma... 0.5 A per channel (electrically limited) Total current of the outputs Depends on the ambient temperature: ( 4 A max. 75 C ( 8 A max. 65 C X0 external supply Supply voltage U H 18... 32 V DC Max. power 8 A (depends on the total current of the outputs) consumption I H Signal transmission Max. delay from < 1 ms signal / internal bus Max. delay from Filter without small medium large frequency input / internal bus Frequency 0.1 Hz ( f < 1 Hz 1/f + 1 ms 2/f 3/f 6/f 1 Hz ( f < 10 Hz 1/f + 1 ms 4/f 9/f 18/f 10 Hz ( f < 100 Hz 1/f + 1 ms 8/f 27/f 54/f 100 Hz ( f < 1 khz 1/f + 1 ms 16/f 81/f 162/f 1 khz ( f < 1,960 Hz 1.5 ms 32/f 243/f 486/f 1,960 Hz ( f < 10 khz 1.5 ms 16.5 ms 124 ms 248 ms 10 khz ( f < 20 khz 1.5 ms 33 ms 372 ms 744 ms f ) 20 khz 1.5 ms 66 ms 372 ms 744 ms Note: for 3-wire PNP proximity switches f < 1 khz X0 "Plant STOP" control input Function "Plant STOP" to switch off all outputs Suitability Switch off at SIL 2 (IEC 61508) Control input X0 3, 4 "Normal operation" ("Plant STOP" deactiviated) Terminals bridged "OFF" ("Plant STOP" activated) Interrupted Galvanic separation Test voltages acc. to standard EN 60079-11 Between ) 1800 V AC auxiliary power / system components Between I/O channels / ) 1800 V AC system components Between I/O channels / ) 1800 V AC ground (PA) Electromagnetic compatibility Tested to the following standards and regulations: EN 61326-1 (2006) IEC 61000-4-1 6, NAMUR NE 21 Electrical connection Power supply BusRail Types 9494 Ex n field signals 2 plug-in, black terminals, 24-pin, 1.5 mm 2, push-in design with lock (must be ordered separately) External supply Plug-in, black terminals, 4-pin, 1.5 mm 2, screw terminal design with lock (included) and "Plant STOP" Auxiliary power Version Intrinsically safe Ex ia via BusRail Behaviour during All outputs "Off" undervoltage Max. current consumption 90 ma Max. power consumption < 2.2 W Max. power dissipation < 4.7 W Remote I/O /3

Device-specific data Settings Module Diagnostics message Signal Signal type Pulse extension / frequency filter Inverting input/output Line fault monitoring Behaviour in case of error Operating mode counter/frequency Counter control Counting event ON / OFF NAMUR proximity switch / contact; 3-wire PNP proximity switch; output 0 s / off; 0.6 s / small; 1.2 s / medium; 2.4 s / large (setting is made for channel pairs) normal / inverted (setting is made for channel pairs) ON / OFF Replacement value '0'; replacement value '1'; hold (initial value 0); hold (initial value 1) Counter 16 bit; 0.1... 600 Hz; 1 Hz... 3 khz; 1 Hz... 20 khz; 1 Hz... 20 khz with direction; Up/Down 16 bit counter; Up/Down 32 bit counter (setting is made for channel pairs) Run, Stop, Reset Positive slope; negative slope (setting is made for channel pairs) Ambient conditions Ambient temperature -40... +75 C (observe operating instructions) Storage temperature range -40... +80 C Maximum relative humidity 95% (without condensation) Maximum operating height < 2,000 m Semi-sinusoidal shock 15 g (3 shocks per axis and direction) (IEC EN 60068-2-27) Sinusoidal vibration (IEC EN 60068-2-6) 1 g in the frequency range 10... 500 Hz 2 g in the frequency range 45... 100 Hz Mechanical data Degree of protection (IEC 60529) IP30 Module enclosure Polyamide 6GF Fire resistance (UL-94) V2 Pollutant class corresponds to G3 Dimensions L = 139.5 mm, W = 98 mm, H = 64 mm Indication LED indication Module requires maintenance "M/S" LED, blue Operating state "RUN" LED, green Group error "ERR" LED, red Channel error LED, red for each channel Channel status LED, yellow for each channel 24 V external supply "24 V" LED, green "Plant STOP" "24 V" LED, yellow Function indication Retrievable parameters Manufacturer, type, hardware revision, software revision, serial number Error indication Module status and alarms Signal errors for each channel Signal status bit Open circuit Primary / redundant internal bus error No response from IOM Configuration does not correspond to the module Hardware error Excess temperature Slot error Module requires maintenance "1" = signal interfered; "0" = signal valid NAMUR input: I < 100 μa 3-wire PNP proximity switch: U IN < 1.6 V Output: I < 30 μa in ON state R > 8 kω in OFF state Short circuit NAMUR input: 3-wire PNP proximity switch: R < 100 Ω U IN < 1.6 V Output: I < 700 ma in ON state R > 40 kω in OFF state Mounting / Installation Installation position Horizontal or vertical (observe operating instructions) Mounting type On 35 mm DIN rail NS 35/15 (DIN EN 60715) /4 Remote I/O

Accessories and Spare Parts Designation Figure Description Art. no. Plug-in terminal 1.5 mm 2 with lock, 24-pole, spring clamp connection, black, for connecting 245091 the field signals to I/O modules, for non-intrinsically safe field circuits Caution: only for 9471/35 and 9472/35 I/O modules Labelling: 25... 48 Resistor error message suppression Labelling strips 17744E00 17743E00 17310E00 1.5 mm 2 with lock, 24-pole, spring clamp connection, black, for connecting the field signals to I/O modules, for non-intrinsically safe field circuits Caution: only for 9471/35 and 9472/35 I/O modules Labelling: 1... 24 245090 The resistors are used to suppress error messages for unused I/O channels 244911 Resistance value: 5K6 / 0.5 W Suitable for: AIM 9468; DIOM 9470; DIOM 9471; DIOM 9472; DOM 9475 For intrinsically safe circuits (simple apparatus according to EN 60079-11) "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips 162788 DIN sheet 05869E00 For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets 162832 Partition 09900E00 For mounting between intrinsically safe and non-intrinsically safe connections of the I/O modules, in order to adhere to the required 50 mm distance 220101 Warning sign 15196E00 "Clean modules only with a damp cloth." 162796 05872E00 Dimensional Drawings (All dimensions in mm [inches]) Subject to alterations 68 [2,68] 136 [5, 35] 128,5 [5,06] 139,50 [5, 49] 64 [2,52] 70 [2,76] 98 [3,86] 96,5 [3,8] 17625E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Remote I/O /5