INSTALLATION MANUAL NMEA DATA CONVERTER IF-NMEA2K2

Similar documents
INSTALLATION MANUAL NMEA DATA CONVERTER IF-NMEA2K2

OPERATOR'S MANUAL GPS RECEIVER GP-320B MODEL.

Installation Manual WIND TRANSDUCER

Installation Manual VHF RADIOTELEPHONE FM-8800D/8800S

SAFETY INSTRUCTIONS... i. EQUIPMENT LISTS... ii. SYSTEM CONFIGURATION... iii

Installation Manual COLOR LCD SOUNDER FCV-1150

Installation Manual Multi Function Display MFD8/MFD12

Installation Manual COLOR LCD SOUNDER FCV-1150

Omochi rabbit amigurumi pattern

Installation Manual GPS RECEIVER GP-310B

INSTALLATION MANUAL COLOR GPS/PLOTTER GP-1650W/1650WD

INSTALLATION MANUAL COLOR DGPS/PLOTTER GP-1850WD COLOR GPS PLOTTER GP-1850W

MARINE RADAR FR-8062/8122/8252

INTEGRATED HEADING SENSOR PG-500 FLUXGATE HEADING SENSOR C-500

INSTALLATION MANUAL COLOR DGPS/PLOTTER GP-1850WD COLOR GPS PLOTTER GP-1850W

アルゴリズムの設計と解析. 教授 : 黄潤和 (W4022) SA: 広野史明 (A4/A8)


Installation Manual MULTI-COLOR LCD RADAR

Decisions in games Minimax algorithm α-β algorithm Tic-Tac-Toe game

INSTALLATION MANUAL GPS NAVIGATOR GP-150

OPERATOR'S MANUAL NAVTEX RECEIVER NX-300 MODEL.

U N I T. 1. What are Maxine and Debbie talking about? They are talking about. 2. What doesn t Maxine like? She doesn t like. 3. What is a shame?

3 안전을위한주의사항 AAH-02B3W. Product Composition & Specifications. Product Manual. Cautions for Safety. Cautions for Safety. Cautions.

D80 を使用したオペレーション GSL システム周波数特性 アンプコントローラー設定. Arc 及びLine 設定ラインアレイスピーカーを2 から7 までの傾斜角度に湾曲したアレイセクションで使用する場合 Arcモードを用います Lineモード

OPERATOR'S MANUAL SATELLITE COMPASS SC-30 MODEL.

The FA-30 delivers Real-Time AIS information to navigation systems providing critical collision avoidance information

A : MAY Pub. No. OME A. The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer

Omni LED Bulb. Illustration( 实际安装, 설치사례, 設置事例 ) Bulb, Downlight OBB. OBB-i15W OBB-i20W OBB-i25W OBB-i30W OBB-i35W. Omni LED.

The FA-50 offers accurate information for collision avoidance

Lesson 5 What The Last Supper Tells Us

Intermediate Conversation Material #10

TDK-Lambda A C 1/27

PH75A280-* RELIABILITY DATA 信頼性データ

DAITO DENSO MODEL. HFS30-24 Conducted Emission (VCCI-B) with Case Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : WJ-01

Brief installation guide for FA-100 Universal AIS

NMEA Flash input interface

DAITO DENSO MODEL. DFS50-24 Conducted Emission (VCCI-B) with Cover and Chassis Conditions Vin : 100VAC / 50Hz Iout : 100% Phase : WJ-01

CER7027B / CER7032B / CER7042B / CER7042BA / CER7052B CER8042B / CER8065B CER1042B / CER1065B CER1242B / CER1257B / CER1277B

P Z N V S T I. センサ信号入力仕様 Input signal type. 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma 1 ~ 5 V 4 ~ 20 ma

CPM6018RA Datasheet 定電流モジュール. Constant-current Power Modules. TAMURA CORPORATION Rev.A May, / 15

相関語句 ( 定型のようになっている語句 ) の表現 1. A is to B what C is to D. A と B の関係は C と D の関係に等しい Leaves are to the plant what lungs are to the animal.

Final Product/Process Change Notification Document # : FPCN22191XD1 Issue Date: 24 January 2019

TDK Lambda A /9

次の対話の文章を読んで, あとの各問に答えなさい ( * 印の付いている単語 語句には, 本文のあとに 注 がある )

Infineon 24GHz Radar Solution. May 2017 PMM RSF DM PMM Business development

COLOR GPS PLOTTER GP-3300 COLOR VIDEO PLOTTER GD-3300

User s Manual. Revision 1.2. Copyright 2005 Maretron, LLC All Rights Reserved

INTERNATIONAL STANDARD

TDK Lambda WC /24

TED コーパスを使った プレゼンにおける効果的な 英語表現の抽出

1XH DC Power Module. User manual ユーザマニュアル. (60V 15A module version) HB-UM-1XH

Installation Manual MARINE RADAR MODEL 1622

GPS RECEIVER GP-320B

for collision avoidance

041 GPS Interface (001 processor only)

JMA-3300 Radar. Semi-Constaview digital signal processing inch ultra bright LCD New System-on-Chip technology

Date of issue: Version 01. December TRANSAS ISAILOR Functional comparison on ios and Android platforms.

Delivering Business Outcomes

Hacked ace gangster. City Hacked. Key hacks [3] Money [4] Health [5] Exp [6] Ammo for all weapons [7] Attribute points [8] Skill

Minecraft You Need To Run The Version Manually At Least Once

VHF 100/200 Series Radio Installation Instructions

超小型 Very small (L:3.2 W:1.5 t:0.4mm) 高利得 High gain 無指向性 Omini-directional. < 用途 Applications> PHS 機器 DECT 機器 その他 PHS & DECT systems, etc ST01

Intelligent Dual Channel NAVTEX Receiver System with Optional Instrument Data display

INTEGRATED HEADING SENSOR PG-1000

修士 / 博士課程専門課題 Ⅱ 試験問題

User s Manual. Revision 1.4. Copyright 2009 Maretron, LLP All Rights Reserved


NMEA 2000 Parameter Group Numbers and Description as of August 2007 NMEA 2000 DB Ver

NMEA2000- Par PGN. Mandatory Request, Command, or Acknowledge Group Function Receive/Transmit PGN's

磁気比例式 / 小型高速応答単電源 3.3V Magnetic Proportion System / Compact size and High-speed response. Vcc = +3.3V LA02P Series

Effective Utilization of Patent Information in Japanese global companies

Multi-bit Sigma-Delta TDC Architecture for Digital Signal Timing Measurement

NSSM124T Pb-free Reflow Soldering Application RoHS Compliant RGB Sorted (RGB die lit separately.)

AIS6 / MFR6 User Manual

Big thank you from Fukushima Friends UK (FF)

Keio University Global Innovator Accelera6on Program 2015 Day 7 Design Process Exercise

The NMEA 0183 Information sheet. Everything you wanted to know about NMEA 0183 (but were afraid to ask) Understanding the NMEA 0183 specification

XG PARAMETER CHANGE TABLE

F01P S05L, F02P S05L, F03P S05L SERIES

Baudrate Conversion Options For Brookhouse NMEA multiplexers models AIS and AISC

JMA Activities on New-generation Himawari-8 Geostationary Satellite in RA-V. Hiroshi KOIDE Japan Meteorological Agency(JMA)

Private Equity: where should you invest today? P&I Global Pension Symposium, Tokyo

Eagle Cuda 240i S/GPS

P (o w) P (o s) s = speaker. w = word. Independence bet. phonemes and pitch. Insensitivity to phase differences. phase characteristics

TDK Lambda INSTRUCTION MANUAL. TDK Lambda C A 1/35

品名 :SCM1561M 製品仕様書. LF No RoHS 指令対応 RoHS Directive Compliance 発行年月日 仕様書番号 SSJ SANKEN ELECTRIC CO., LTD. 承認審査作成 サンケン電気株式会社技術本部 MCD 事業部

NSSM124T Pb-free Reflow Soldering Application RoHS Compliant RGB Sorted (RGB die lit separately.)

L1 Cultures Go Around the World

NFCLL060B-V1 Built-in ESD Protection Device RoHS Compliant

INTERCONNECTION DIAGRAM FA-50

スマートシン. 新巻線方式採用 自動巻線によるブラシレスレゾルバ Brushless resolvers based on a novel automatic winding method. 08 型 Size 08 自社開発の新自動巻線方式により高性能 高品質をローコストにて量産しております

[ 言語情報科学論 A] 統計的言語モデル,N-grams

TDK Lambda C /35

Airmar PB200. Furuno. Furuno FI504 FI501 XDR N2K N2K N2K. Furuno. Furuno FI504 FI504 N2K N2K. Terminal RX2 A RX2 B

Sales & Marketing: Version 1.01

4. Contact arrangement 回路形式 1 poles 1 throws 1 回路 1 接点 (Details of contact arrangement are given in the assembly drawings 回路の詳細は製品図による )

NJSW172T Pb-free Reflow Soldering Application Built-in ESD Protection Device RoHS Compliant

Creation of Digital Archive of Japanese Products Design process

Addendum I. Additional Instructions for. Lowrance M68i S/Map

Chronicle of a Disaster: Understand

Transcription:

INSTALLATION MANUAL NMEA DATA CONVERTER WARNING Do not install the unit where it may get wet from rain or water splash. Water in the unit can result in fire, electrical shock or damage the equipment. Do not disassemble or modify the equipment. Observe the following compass safe distances to prevent interference to a magnetic compass: CAUTION standard compass steering compass 0.30m 0.30m Fire, electrical shock or serious injury can result. www.furuno.com

System Configuration The NMEA Data Converter converts Furuno CAN bus format data to NMEA0183 format data and vice versa. NMEA DATA CONVERTER Furuno CANbus cable Furuno CAN bus device NMEA0183 cable NMEA0183 device * PC, etc. * (RS-232C) * : NMEA0183 cable can not be connected to NMEA0183 device and PC, etc. (RS-232C) at the same time. Mode Conversion Specifications of NMEA Data Converter Interface Furuno CAN bus NMEA0183 Power Supply 12V 96mA (LEN: 2) Environmental conditions Ambient -15 ~55 temperature Waterproofing standard IP55* *: NMEA0183 cable terminal is not waterproof. Relative humidity 95% (at 40 ) Storage temperature -20 to 60 Vibration resistance IEC60945 Equipment List Name Type Code No. Qty Remarks NMEA Data Converter - 1 Self Tapping Screw 3x20 000-167-940-10 2 2

Installation Mounting Considerations Locate the data converter well away from areas subject to water splash and rain. Keep the data converter out of direct sunlight because of heat that can build up inside the cabinet. Mounting Fix the data converter to the mounting location with two self tapping screws (3x20), referring to the outline drawing in this manual. Wiring Connection to Furuno CAN bus device Connect the Furuno CAN bus cable to the Furuno CAN bus device. See Furuno CAN bus Network Design (TIE-00170-x) for details about CAN bus network. Connection to NMEA0183 device Connect the NMEA0183 signal cores to NMEA0183 device, referring to the interconnection diagram as below. Note1: NMEA0183 cable terminal is not waterproof. Therefore, install the equipment away from areas subject to water splash and rain. Note2: Wind vinyl tape around unused cores and fix the cores so that they do not touch other signal cores or ground. NMEA0183 cable PORT1 (ORG), PORT2 (PPL), GND (BLK) signal cores of the NMEA0183 cable are short-circuited. (default) NMEA Data Converter PORT1 PORT2 GND TD_A TD_B RD-C RD-H SD RD SG Drain ORG PPL BLK YEL GRN BLU WHT RED BRN GRY Drain RD-H RD-C TD-B TD-A RD SD GND NMEA0183 device * PC, etc. * (RS-232C) Ship s ground * : NMEA0183 cable can not be connected to NMEA0183 device and PC, etc. (RS-232C) at the same time. 3

Conversion Mode PORT1 (ORG), PORT2 (PPL), GND (BLK) signal cores of the NMEA0183 cables are short-circuited (default). By cutting the specified signal core, the conversion mode can be changed. Select the conversion mode according to the baud rate of the connected device. For connection to an AIS device, select the AIS mode. Note1: Check the applicable checkbox on the nameplate according to the conversion mode selected. Note2: Wind vinyl tape around unused cores and fix the cores so that they do not touch other signal cores or ground. NMEA0183 or PC, etc. connection cores NMEA0183 cable PORT1 (ORG), PORT2 (PPL), GND (BLK) signal cores of the NMEA0183 cable are short-circuited (default). Cut the PORT1 (ORG) or PORT2 (PPL) signal core. Bind signal cores with vinyl tape. Wind vinyl tape around cores to insulate them. Action Conversion Mode / Baud Rate No action* Normal / 4800bps (default setting) Cut the PORT1 (ORG) High Speed / 38400bps Cut the PORT2 (PPL) AIS / 38400bps *: To change the conversion mode to Normal, cut PORT1 and PORT2. Turning Power On No operation is required for the user to turn the power on. The power is supplied by Furuno CAN bus line. The Power LED (yellow) flashes when the data converter is powered. Power LED 4

Input/Output Comparing Furuno CAN bus NMEA0183 Some Furuno CAN bus PGN output a number of NMEA0183 sentences. means nonperiodic. ID means Message ID. Sending Cycle Furuno CAN bus Input NMEA0183 Output Normal High AIS Speed 65280 Heave [Proprietary PGN] PFEChve 100ms 126992 System Time ZDA 1s 1s 127245 Rudder RSA 100ms 127250 Vessel Heading HDG 1s 100ms HDT 1s 100ms VHW 1s 1s 127251 Rate of Turn ROT 100ms 127257 Attitude PFECatt 100ms 127258 Magnetic Variation HDG 1s 100ms 128259 Speed Through Water VHW 1s 1s VTG 1s 1s 128267 Water Depth DPT 1s 1s 128520 Tracked Target Data TTM 129026 COG & SOG, Rapid Update 129029 GNSS Position Data 129033 Time & Date VTG 1s 1s GGA 1s 1s ZDA 1s 1s 129038 AIS Class A Position Report VDM ID: 1,2,3 129039 AIS Class B Position Report VDM ID: 18 129040 AIS Class B Extended Position VDM Report ID: 19 129041 AIS Aids to Navigation (AtoN) VDM Report ID: 21 129283 Cross Track Error RMB 1s, 2s* 1s 129284 Navigation Data RMB 1s, 2s* 1s 129285 Navigation Route/WP RMB 1s, 2s* 1s Information 129793 AIS UTC and Data Report VDM ID: 4 129794 AIS Class A Static and Voyage VDM Related Data ID: 5 129795 AIS Addressed Binary Message VDM ID: 6 129797 AIS Binary Broadcast Message VDM ID: 8 5

Sending Cycle Furuno CAN bus NMEA0183 Normal High AIS Input Output Speed 129798 AIS SAR Aircraft Position Report VDM ID: 9 129801 AIS Addressed Safety Related VDM Message ID: 12 129802 AIS Safety Related Broadcast VDM Message ID: 14 129808 DSC Call Information DSC 129809 AIS Class B CS Static Data Report, Part A 129810 AIS Class B CS Static Data Report, Part B 130306 Wind Data DSE VDM ID: 24 VDM ID: 24 MWD 1s 1s MWV 1s 100ms 130310 Environmental Parameters MDA 1s, 5s* 1s 130311 MTW 1s 1s 130312 Temperature MDA 1s, 5s* 1s MTW 1s 1s *: When the volume of sent data exceeds the communication band, the TX interval becomes longer. NMEA0183 Furuno CAN bus Some NMEA0183 sentences output a number of Furuno CAN bus PGN. The latest inputted sentence is given priority. means nonperiodic. ID means Message ID. NMEA0183 Input Furuno CAN bus Output Sending Cycle APB, RMB 129283 Cross Track Error 1s 129284 Navigation Data 1s 129285 Navigation Route/WP Information BWC, BWR 129284 Navigation Data 1s 129285 Navigation Route/WP Information DPT 128267 Water Depth 1s DSC, DSE 129808 DSC Call Information GGA, GLL, 129029 GNSS Position Data 1s GNS HDG 127250 Vessel Heading 100ms 127258 Magnetic Variation 1s HDT 127250 Vessel Heading 100ms MDA, MTW 130310 Environmental Parameters 500ms 130312 2s MWD, MWV 130306 Wind Data 100ms RMC 126992 System Time 1s 127250 Vessel Heading 100ms 127258 Magnetic Variation 1s 128259 Speed Through Water 1s 129026 COG & SOG, Rapid Update 250ms 129029 GNSS Position Data 1s 129033 Time & Date 1s ROT 127251 Rate of Turn 100ms 6

NMEA0183 Input Furuno CAN bus Output Sending Cycle RSA 127245 Rudder 100ms THS 127250 Vessel Heading 100ms TLL 130828 Mark Position Information [Proprietary PGN] VDM 129038 AIS Class A Position Report ID: 1,2,3 129039 AIS Class B Position Report ID: 18 129040 AIS Class B Extended Position Report ID: 19 129041 AIS Aids to Navigation (AtoN) Report ID: 21 129793 AIS UTC and Data Report ID: 4 129794 AIS Class A Static and Voyage Related Data ID: 5 129795 AIS Addressed Binary Message ID: 6 129797 AIS Binary Broadcast Message ID: 8 129798 AIS SAR Aircraft Position Report ID: 9 129801 AIS Addressed Safety Related Message ID: 12 129802 AIS Safety Related Broadcast Message ID: 14 129809 AIS Class B CS Static Data Report, Part A ID: 24 129810 AIS Class B CS Static Data Report, Part B ID: 24 VHW 127250 Vessel Heading 100ms 128259 Speed Through Water 1s VTG 128259 Speed Through Water 1s 129026 COG & SOG, Rapid Update 250ms XTE 129283 Cross Track Error 1s ZDA 126992 System Time 1s 129033 Time & Date 1s PFECatt 127257 Attitude 100ms PFEChve 65280 Heave [Proprietary PGN] 1s 7

PACKING LIST 14CV-X-9851-1 1/1 ユニット N A M E O U T L I N E DESCRIPTION/CODE Q'TY UNIT NMEAテ ータ変換器 NMEA DATA CONVERTER 工事材料 + トラスタッヒ ンネシ SELF TAPPING SCREW 図書装備要領書 ( 和英 ) INSTALLATION MATERIALS DOCUMENT 000-020-511-00 3X20 SUS304 000-167-940-10 1 2 INSTALLATION MANUAL (JP/EN) IMC-44591-* 000-176-101-1* 1 型式 / コート 番号が2 段の場合 下段より上段に代わる過渡期品であり どちらかが入っています なお 品質は変わりません TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME. ( 略図の寸法は 参考値です DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 14CV-X-9851

A B C 1 ネットワーク機器 NETWORK EQUIPMENT CAN bus SHIELD NET-S NET-C NET-H NET-L 1 2 3 4 5 LTWM12-05BMMM -SL7000 アカクロシロアオ RED BLK WHT BLU 0.3m 2 3 4 NMEA データ変換器 NMEA DATA CONVERTER 2m ダイ ORG ムラサキ PPL クロ BLK キ YEL ミト リ GRN アオ BLU シロ WHT アカ RED チャ BRN ハイ GRY DRAIN 1 2 RD-H RD-C TD-B TD-A SHIELD RS-485 航法装置 V EQUIPMENT (NMEA0183 Ver3.0) RD SD GND RS-232C 切断ライン番号 CUTOFF LINE No. なし DEFAULT 絶縁色 COLOR モード MODE NORMAL 1: PORT 1 ダイ ORG HIGH SPEED 2: PORT 2 ムラサキ PPL AIS 両方切断 : 切断なし ( 工場設定 ) と同じ設定 CUTOFF BOTH LINE: SAME AS DEFAULT SETTING DRAWN 12/Jan/2012 CHECKED 12/Jan/2012 APPROVED DWG.No. T.YAMASAKI H.MAKI 名称 NMEA データ変換器 相互結線図 kg ME NMEA DATA CONVERTER C4459-C02- B REF.No. 14-080-5000-0 INTERCONNECTION DIAGRAM SCALE MASS TITLE