DC POWER SUPPLY AX-3003L-3 AX-3005L-3. Users manual

Similar documents
MULTI-OUTPUT DC REGULATED POWER SUPPLY

REGULATED DC POWER SUPPLY OPERATION MANUAL

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

Multi-output DC Power Supply

Model: &

Model 1737 Dual Range DC Power Supply

Introduction to Electronic Equipment

TOA 900 SERIES POWER AMPLIFIER P-924A

AMM-1022 Digital Multimeter USER`S MANUAL

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

DSSIU-6-1U-V. Features VOM:

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

INSTRUCTIONS PS2500 POWER SUPPLY

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

SPECIFICATION & USER'S GUIDE

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

AUM FAMILY Programmable DC Power Supplies

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

8110 FUNCTION GENERATOR. Safety Instruction. Safety Symbols

USER'S MANUAL DMR-6700

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

OPERATOR S INSTRUCTION MANUAL

Owner s Manual B 300 B 600 B 900 B 1200 B 1500 B 902 B 1202 B 1802 B300 B1802

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

SPECIAL 6. 6-Watt Vacuum Tube Guitar Amplifier. User Manual

8120 FUNCTION GENERATOR Operation Manual

Thank you very much for choosing Shuguang Audio Classic Series vacuum tube amplifier

DMM8900 SERIES USERS MANUAL

User Manual Digital Multimeter

No. 139 Jinghai Third Road, BDA, Beijing, China, Office TEL. +86 (10) Website

INSTRUCTION MANUAL POWERED MIXER MX-628

Brake Unit. Contents. Brake Unit Overview Product information C-26 C-27

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

DCS-E 1kW Series & DCS-E 1.2kW Series DC Power Supplies

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

ET-3888 True RMS Clamp Meter. User Manual

Agilent E3631A Triple Output DC Power Supply

Model DIGITAL MULTIMETER

Bench Test Instruments and Handheld Oscilloscopes Basic Service

BENNING. CM7 Electrical Tester. Service Information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

WD series DIN Rail or Screw Mounted Protective Relays

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

1.General instructions Specifications Description...7

Built-in Amplifier Photoelectric Sensor

400Amp True RMS AC Clamp Meter + NCV

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

DIGIT & POINTER MULTIMETER

CONTENTS. SAFETY PRECAUTIONS: Before use, read the following safety precautions

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

24W. Switching Power Adapter SPECIFICATION. Description: 24Volts / 1.0Amps. Part No.: AD-AT24010T. Version: Date: Page 1 of 7

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

UP1301A-( )( ) SERIES

DCS-E 1kW Series DC Power Supplies

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

3B SCIENTIFIC PHYSICS

AMC-100 AMC-101 AMC-100 AMC-100B AMC-100D AMC-101 AMC-101B AMC-101D AMC-100A AMC-100C AMC-100E AMC-101A AMC-101C AMC-101E. AC Motor Controllers

For Safety information, Warranties, and Regulatory information, see the pages behind the Index.

PagePac Plus AmpliCenter V A - (D300A) V A - (D100A) V (D40) Installation and Use

DIGITAL MULTIMETER INSTRUCTION MANUAL

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Measurement and control. Digital instruments and measuring transducers

AC/DC CLAMP METER USER S MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

Agilent E361xA 60W BENCH SERIES DC POWER SUPPLIES OPERATING AND SERVICE MANUAL FOR MODELS:

Table of Contents Title Page

MW3105 DIGITAL CLAMP MULTIMETER

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

USER'S MANUAL DMR-2400

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

A 4000 A Owner s Manual HPA HPA A4000 A5000 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2 CHANNEL 1 PROFESSIONAL POWER AMPLIFIER POWER CHANNEL 2

NIKO-SEM. 0.8A Fixed and Adjustable Low Dropout Linear Regulator (LDO) L1087XG Series SOT-89,TO-92 Lead-Free FEATURES GENERAL DESCRIPTION APPLICATIONS

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

WATT TRANSDUCER. Instruction Manual

M-1000D DIGITAL MULTIMETER

TOA 500 SERIES MIXER POWER AMPLIFIER

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

OPERATOR S INSTRUCTION MANUAL

ARBE-III Instruction Manual

TOA NEW 900 SERIES POWER AMPLIFIER

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

FREJA 306 Relay Testing System

CONTENTS MS2033A. 1.Introduction Safety Information...01

Transcription:

DC POWER SUPPLY AX-3003L-3 AX-3005L-3 Users manual

This series includes two-way and three-way DC regulated power supply. Three-way have high accuracy output, of which two way are adjustable and one way is fixed. The two adjustable outputs can be selected for constant voltage (C.V.) or constant current (C.C.), designed in high stability and performance circuit. In constant voltage operation mode, the output voltage can be arbitrarily adjusted from 0V on to the nominal range. In constant current operation mode, the output current can be adjusted from 0A on in the nominal range. The two outputs can be connected in parallel or in series, while the master adjust controls the voltage and current setting. The fixed output voltage is 5V. This output features good stability and low ripple along with overload (e.g. short circuit) protection. The unit features small size and excellent performance combined with an elegant design, being ideal for research, university, industry and appliance maintenance laboratories. 1. TECHNICAL SPECIFICATION 1.1 Model: QJ3003EIII, QJ3005EIII 1.1.1 Input voltage: 220VAC 50Hz 1.2 Two adjustable outputs 1.2.1 Output voltage: 0-30V (adjustable continuously) 1.2.2 Output current: 0-3A (0-5A) (adjustable continuously) 1.2.3 Source regulation: CV 0.01%+3mV CC 0.01%+6mA 1.2.4 Load regulation: CV 0.01%+2mV (rated 5A) CV 0.01%+5mV (rated> 5A) CC 0.01%+6mA 1.2.5 Ripple and noise: CV 1mV (rms) CV 20mVp-p CC 3mA (rms) CC 50mAp-p 1.2.6 Protection: current-limiting protection 1.2.7 Indication: Voltmeter & Ammeter or 3-digit volt-led & Amp- LED a. Volt-indication: LED ±1%±2digits b. Amp-indication: LED ±2%±2digits 1.3 Fixed output: 1.3.1 Output voltage: 5V±3% 1.3.2 Output current: 3A 1.3.3 Source regulation: 1 10-4 +1mV 1.3.4 Load regulation: 1 10-3 1.3.5 Ripple & noise: 0.5mV(rms) 10mVp-p 1.3.6 Protection: current-limiting & short-circuit protection 1.4 Operating ambient 1.4.1 Operating temperature: 0 to +40ºC

1.4.2 Relative humidity: less than 90% 1.5 Size: 360mm 265mm 165mm 1.6 Operating time: 8 hours continuously 2. OPERATION 2.1 Controls and description of front-panel (1) Meter or LED: indicates master output voltage and current value. (4) Meter or LED: indicates slave output voltage and current value. (5) Slave constant voltage adjustment: adjust slave output voltage value. (6) Slave constant current adjustment: adjust slave output current value (adjust the current-limiting protection point). (7) Power switch: It is set to ON state(the switch is pressed in), the unit is switched on, at this time, the constant voltage (C.V.) or constant current (C.C.) indicator is on, otherwise, the unit is in OFF state (the switch is sprung out). (8) Slave constant current state or two-way parallel state indicator: When slave output is in constant current state or the two adjustable is in parallel, this indicator is on. (9) Slave constant voltage indicator: When slave output is in constant voltage state, this indicator is on. (10) Slave output negative binding post: Negative polarity of output voltage is connected to negative (11) Case grounded terminal: The case is connected to the earth. (12) Slave output positive binding post: positive polarity of output voltage is connected to positive (13/14) The control switch for selecting the two adjustable outputs independent, series or parallel. (15) Master output negative binding post: Negative polarity of output voltage is connected to negative (16) Case grounded terminal: The case is connected to the earth. (17) Master output positive binding post: Positive polarity of output voltage is connected to positive (18) Master output constant current state indicator: When master output is in constant current state, this indicator is on. (19) Master output constant voltage state indicator: When master output power is in constant voltage state, this indicator is on. (20) Fixed 5V DC output negative binding post: Negative polarity of output voltage is connected to negative (21) Fixed 5V DC output positive binding post: Positive polarity of output voltage is connected to positive (22) Master output constant current adjustment: Adjust master output current value. (Adjust currentlimiting protection point) (23) Master output constant voltage adjustment: Adjust master output voltage value.

2.2 Operating procedure: 2.2.1 Independence use of two adjustable outputs. 2.2.1.1 Set the (13) and (14) switch to spring out position ( position). 2.2.1.2 When the adjustable output is used as C.V. output, first should rotate clockwise the C.C. adjustment (6) and (22) to Max, then turn on power switch (7), adjust C.V. adjustment (5) and (23) till slave & master DC output voltage reach required voltage value, at this time, the C.C indicator (8) and (18) light off. 2.2.1.3 Used as C.C. output, after turning on power switch (7), first rotate clockwise the C.V. adjustment (5) and (23) to Max, while rotate counterclockwise the C.C. adjustment (6) and (22) to Min, then connect the required load, again rotate clockwise adjustment (6) and (22) till output current reach the required current value. At this time, the C.V. State indicator (9) and (19) go out and the C.C. state indicator (8) and (18) light on. 2.2.1.4 Used as the C.V. output, in general the C.C. adjustment (6) and (22) should be set to Max, but for this unit, the current-limiting protection point can also be set arbitrarily. Setting procedure is: Turn on power, rotate counterclockwise the C.C. adjustment (6) and (22) to Min, then make the positive and negative output terminal in short connection and rotate clockwise the C.C. Adjustment (6) and (22) till output current equal to the required current-limiting protection point, so the current-limiting protection point is well set. 2.2.2 Series using of the two adjustable outputs 2.2.2.1 Press in switch (13) ( position),switch (14) is set to OUT position ( position). At this time, turn the master voltage adjustment (23) and the slave output voltage tracks strictly the master output voltage, and the output voltage can be up to 60V (voltage between terminal of (10) and (17)). 2.2.2.2 Before the series connecting,it must be examined if the negative terminals of both master and slave output are connected to GND terminal, if they are, it must be disconnected, otherwise, shortcircuit will be caused in the slave output when the two outputs are connected in series.

2.2.2.3 When the two outputs are in series, the output voltage is controlled by master output, but current adjustment of two outputs is still independent. Therefore, attention should be paid to the position of the C.C. adjustment (6). For example, knob (6) is at the position of counterclockwise to end or current of slave output excesses current-limiting protection point, at this time, the voltage of slave output will not track the voltage of master. So knob (6) should be rotated clockwise to Max. when the two output are in series. 2.2.2.4 By series connection, if there is power output, proper leads corresponding to output power should be used to short connect the negative terminal of master output with positive terminal of slave output reliably. Since it is shorted by a switch inside the unit, current will pass on the shorted switch when there is power output. This will affect the reliability of the unit. 2.2.3 Parallel using of the two adjustable outputs 2.2.3.1 Press in switch (13) ( position) as well as switch (14) ( position), at this time, the two outputs are in parallel, adjust voltage adjustment (23) of master output the voltage of two ways keep same, and slave output C.C. indicator (8) lights on. 2.2.3.2 When the two outputs are in parallel, the C.C. adjustment (6) of slave output does not work. When used as C.C. Supply, simply adjust the C.C. adjustment (22) of master output, at this time output current of both master and slave output are controlled by it and are same, output current is up to 6A or 10A. 2.2.3.3 While the two outputs in parallel, proper leads corresponding to output power be used to short reliably the two positive terminals and the two negative terminals of master & slave output separately, so as to make load connected reliably with the two parallel outputs. If the load is only connected to one of the output terminal, unbalance may be caused to current of the two outputs, this may also damage the series/parallel switch. 2.3 The digital display is in 3-digit. If you need more accurate indication, please use more precise measuring instrument to calibrate it in outer circuit. 2.4 Cautions 2.4.1 The unit has perfect protection function, 5V output has reliable protection for current-limiting and short circuit. The two adjustable outputs have current-limiting protection. As there is controlling circuit for regulating transistor's power loss in the circuit, when short circuit occurs, power loss on large power transistor is not very high, it can not cause any damage to the unit. But there is still power loss when short circuit, in order to reduce aging and energy consumption, so this situation should be find as soon as possible and turn off power, then exclude the faults. 2.4.2 After operating, put the unit in a dry place of good ventilation, and keep it clean. If it is not in use for a long period, pull off the power supply plug for storage. 2.4.3 For maintenance, input voltage must be cut off. 2.4.4 The faults may be caused by the improper operation or abnormal operating ambient and component failure inside the unit. When the faults occur, the output voltage maybe exceed max. Rated output voltage. TAKE CARE WHEN OPERATION AND AVOID UNNECESSARY DAMAGE OF LOAD. 2.4.5 For safety operation, the 3-pin ground terminal of power cord must be grounded securely. 3. Accessories 3.1 Instruction manual 1 copy