ATP Time Switch

Similar documents
02/11/2015

02/11/2015

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

02/11/2015

02/11/2015

Multi-voltage Multi-function. Wiring diagram (without control signal)

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

02/11/2015

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

0.01kV (0 to ±0.99 kv)

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

MODEL: D03128 CLAMP METER

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

UR200SI / UR200WE ENGLISH

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

02/11/2015

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Contents. 1. Safety Description Specifications Operation Instructions Battery Replacement...20.

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

05/09/2012

RS Pro ENGLISH. Datasheet

Tablet Oscilloscope Safety Information

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

CP-E range Benefits and advantages

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Electronic timer CT-SDS.22

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

08/07/2015

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Digital Multimeter, Pen Type

Protection components

83 Series - Modular timers 16 A. Features

Operating Manual MU2000K

Electronic timer CT-SDD.22

02/11/2015

MS2302. Digital Earth Resistance Tester

PART NUMBERING SYSTEM

APB and SR Product Family General Specifications

Subject to changes 11/2003 Page 1/7

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

PART NUMBERING SYSTEM

Caution Symbol. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap.

RS Pro ENGLISH. Datasheet

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

312, 316, 318. Clamp Meter. Users Manual

Output Voltage* (nom.)(adjustable)

Power supply CP-E 24/2.5

8PK-ST1520 Digital Earth Resistance Tester

Multi-voltage Multi-function. BE: Off-delay with control signal BE: Off-delay with control signal CE: On- and off-delay with control signal

Power supply CP-D 24/4.2 Primary switch mode power supply

Wireless Room Thermostat Installation and Operation Y6630D1007

08/07/2015

Power supply CP-E 24/20.0

NZ7. NZ7 Automatic Transfer Switching Equipment. 2. Type designation. 1. General. 3. Operation conditions N Z 7- /

EMI Installation Guidelines

Liquid level monitors and controls

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

2.1 General Specifications

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

SAUDI STANDARD NO. SASO IEC : 2007 SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS

Electrical Multimeter

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

AZATOM SONANCE T1 Digital Radio. DAB+/DAB/FM Radio Alarm Clock. User Manual. This manual is available to download online at

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

83 SERIES. 83 Series - Modular timers A. Features

Power supply CP-E 24/0.75

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

XUA1 - AC Voltage and phase balance relay

Contactors and Contactor Assemblies

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Instantaneous Overcurrent Relay

Primary switch mode power supplies Product group picture

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

RF/High Frequency Meter HF-A3G

38 Series - Relay interface modules A

User Manual Digital Multimeter

Up to 15 kw Power in Charge, 14.4 kva in Standalone and 13.2 kva in Utility Mode. 90 % Typical Efficiency. Charge Mode Output VDC

38 Series - Relay interface modules A

FOUNDATION Fieldbus Junction Box

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Transcription:

ATP1006-2 Time Switch (The time switch timing can be set second.) 1. Function and Scope ATP1006-2 time switch (hereinafter referred to as time switch ) is applicable for regularly controlling switch-on and off of street lamps, advertising light boxes and other equipments in automatic control circuit with AC frequency of 50Hz, rated control power voltage of 220V at most and rated working current of 3A at most. 2. Model and Its Meaning: ATP1006-2 3. Normal Operating Condition and Installation Condition 3.1 Ambient air humidity: -25 ~+40, and the average temperature is no more than +35 in 24h. 3.2 Altitude: no more than 2,000m. 3.3 Humidity: the relative air humidity of the installation site shall be no more than 50% when the maximum temperature is +40, while it can be higher under lower temperature. Special measures shall be taken for the condensation occasionally formed due to temperature change. 3.4 Pollution level: 3. 3.5 In the medium with no explosion hazard and no gas that is enough to corrode metal and destroy the insulation and the place shall not have severe conductive dust. 3.6 In the place where is provided with anti-snow and anti-rain equipment but not be full of water steam. 3.7 In the place without significant shake, shock and vibration. 3.8 Installation class: II. 3.9 Transport and Storage Conditions: -25 to +55. 3.10 Power voltage change scope: 85%~110% rated voltage. 3.11 Protection grade: IP20. 4 Main Technical Parameters 4.1 Rated control power voltage: AC (50Hz): 220V. 4.2 Conventional thermal current: (Ith)16A. 4.3 Category of the auxiliary circuit: AC-15. 4.4 Rated working current (Ie): AC-15 220V 3A. 4.5 Timing error: 1s/d. 4.6 Time control scope: 1sec~168h. 4.7 Mechanical life: 30,000 times. 4.8 Electric endurance: 10,000 times. 4.9 Installation method: Device installed, guide tracked. 4.10 Anti-interference tolerance sees Table 1.

Table 1 Anti-interference Tolerance Item Severity Static discharge tolerance 8 (1±10%) KV (air discharge) Electromagnetic radiation tolerance Test field strength 10 (1±10%) V/m Fast transient tolerance For power line: 2 (1±10%)KV, duration 1min Surge (shock) tolerance For power line:1 (1±10%)KV RF conduction tolerance Open circuit test voltage 10V, frequency scope 150kHz~80MHz Voltage sage tolerance Sag 30% in half a cycle, sag 60% in 5 cycles and 50 cycles, sag 100% in 250 cycles 5 Outline, Installation Dimension and Wiring Method 5.1 Outside dimension and installation dimension see Figure 1. a) ATP1006-2 outside dimension b)atp1006-2 installation dimension Figure 1 Outside dimensions and installation dimensions of ATP1006-2 5.2 Wiring method 5.2.1 Direct control method Power of the controlled appliance is supplied in single-phase, of which the working current is no more than the rated value of this switch. Direct control method may be adopted, wiring method see Figure 2; for light load with great starting current impact, please adopt AC contactor expansion control method. 5.2.2 Single-phase expansion method The controlled appliance is power supplied in single-phase, of which the working current exceeds the rated value of this switch. Please adopt AC contactor expansion control method, see Figure 3. 5.2.3 Three-phase operating method Power of the controlled appliance is supplied in three-phase, so external AC contactor is required hereof. a) The coil voltage of the controlled contactor is AC 220C 50Hz, so its wiring method sees Figure 4; b) The coil voltage of the controlled contactor is AC 380V 50Hz, so its wiring method sees Figure 5.

Figure 2 Direct single-phase controlled wiring diagram Figure 3 Single-phase expansion controlled wiring diagram Figure 4 Three-phase controlled wiring diagram (220V for contactor coil) Figure 5 Three-phase controlled wiring diagram (3800V for contactor coil) 6 Setting and Use This product panel is set with five buttons, namely MD (mode), R (recall), (left), (-) and (+), so it can adjust correspondingly hour (h), minute (min) and date; if there is some operating indication, time switch may be controlled manually or automatically. 6.1 Setting process for time switch parameters (see Figure 6)

Figure 6 Time switch parameters setting process 6.2 Setting processes are as follows: 6.2.1 Press button MD for 3s to cancel the keyboard lockout, so that LOCK may disappear, the current date flash, you can adjust the date then, see Figure 7. Figure 7 6.2.2 Current date and current time adjustment 6.2.2.1 Press buttons and respectively to adjust date, for example, if it is Tuesday, you can adjust to Tu. 6.2.2.2 Press MD to adjust the current time. Press to select the adjusted position and press and to plus and minus, so as to adjust the display time to the current time, see Figure 8. Figure 8 6.2.3 Timing parameters (switch-on/off time) setting

6.2.3.1 After finish operation 6.2.2, press MD to set the timing parameters, see Figure 9. Figure 9 6.2.3.2 1 ON (first switch-on) time setting: press, and respectively to set 1 ON time and date mode, after setting, press MD to enter 1 OFF (first switch-off) time and date mode setting, see Figure 10. Figure 10 6.2.3.3 1 OFF (first switch-off) time and date model setting: set 1 OFF time according to steps specified in 6.2.3.2. 6.2.3.4 Continue to press MD, the screen will display 2 ON, 2 OFF 16 ON, 16 OFF on the left, set switch time and date model of other groups by referring to the above steps. For redundant time period, please press R to remove the time of other groups, so that the liquid-crystal display will show, see Figure 11, and then, press R to recall. Figure 11 6.2.4 After setting time of each group, press to set the date. By then, the screen will show Monday to Sunday types and flash, which means the operating time are alike from Monday to Sunday, press and to select an operating mode suitable for the user, see Table 2. Table 2 Operating Mode SN Operating Mode Achieved function 1 M O T U W E T H F R S A S U Operating time is the same every day 2 M O T U W E T H F R S A Operating time is the same from Monday to Saturday 3 M O T U W E T H F R Operating time is the same from Monday to Friday 4 S A S U Operating time is the same on Saturday and Sunday 5 M O T U W E Operating time is the same from Monday to Wednesday 6 T H F R S A Operating time is the same from Thursday to Saturday 7 M O W E F R Operating time is the same on Monday, Wednesday and Friday 8 T U T H S A Operating time is the same on Tuesday, Thursday and Saturday 9 M O / T U / W E / T H / F R / S A / S U Operating time is different every day

6.2.5 After setting, press MD for 5s, enter operation state, the time switch locks automatically, LOCK shows, and see Figure 12. Figure 12 6.3 After locking the switch, press MD and at the same time to switch manual/automatic status. Continuously press them together, the screen will show AUTO OFF, ON, ON AUTO and OFF successively, see Figure 13. When the circuit shall be on and off temporarily in the process of operation, the combination buttons can be used to adjust the switch to ON and OFF; if the time switch shall work automatically according to the set time, the combination button shall be used to adjust the switch to ON AUTO, then the time switch may work as set, so as to achieve automatic control. Figure 13 7 Notes 7.1 The switch into the line can only be connected to AC220V power supply, do not access the other power. 7.2 If you can not achieve automatic control function,check the lower right corner of the screen (AUTO) is right shown? 7.3 The internal battery can only provide the LCD screen display and settings, such as A1, A2 terminal auxiliary power missed, is unable to drive the relay output.. 7.4 If the user find errors in the products,through short 3, 4 terminal reset,after reset procedures need to set again. 7.5 When the end of the product life, please recycle work product or its components, for not recycled parts, please dispose of, to protect our environment.