Vibro-Meter Vibration Monitor FEATURES Absolute vibration measurement Monitoring of machines and industrial plants Suitable for velocity transducers (CV...) and piezoelectric accelerometers (CA... / CE...) High cable length to the transducer possible 115/230VAC or 24 V DC or 48 V DC Aluminium or sheet steel housing or 19 European card Dual version available LCD Display with protection class IP66 GENERAL The is a compact Vibration Monitor to control stand-alone machines as well as auxiliary aggregates (e.g. fans, pumps, centrifuges, mills, gears, etc.); on who s revising important big installations or process bounds are depending. Among other things it allows observation according to DIN 45665 DIN ISO 10816. Utilized for this are the vibrations of important machine parts (pillow blocks, foundations, casings), converted by rugged and wear-resistant accelerometers with integrated electronics (piezoelectric accelerometer) or velocity transducers in electrical signals. When using a galvanic separation unit of type GSI into the measurement circuit potential differences (up to 4kVeff) between front-end and Vibration Monitor are without influence. In this case the accelerometer (with integrated electronics) needs to provide a current modulating (µa/g) output signal (VIBRO-METER-patent). This method allows supplementary wide signal amplitude- and frequency range, as well as Signal-cable lengths up to 1000m. For the front end circuit control the Vibration Monitor is equipped with a so called OK- System, that works with all mentioned front ends. Using accelerometer and separation unit with PTB-Certificate or velocity transducer in pressure proof casing into the front end circuit, the Vibration Monitor is also suitable to control machines in ex - sectors (beginning with zone 1). Meggitt GmbH/ Version 5 / 01.16 / E 1 / 10
For evaluating the machine state the Vibration Monitor can alternatively consider the velocity after machine-specific filtering (high/low pass combination) or - after simple integration - the displacement. To the vibration size proportional DC signals are available as current or voltage output Two independent adjustable level switches with selectable response delay allow the signalisation of warning and alarm via appropriate assigned relays by dry contacts (fail-safe-function). For field mounting the complete signal- and evaluating electronics is fitted together with the power supply unit into a sheet steel (protection class IP66) or aluminium casing (protection class IP65) dual units in a common casing are available. FUNCTIONAL DISCRIPTION To the signal of the velocity transducer CV 2 (mv/mm/s) or piezoelectric accelerometers CE (mv/g) is converted in a preamplifier into a standardized voltage signal (velocity 70, 7 mv/mm/s RMS)). Following it is passed via a high- / a low pass filter and amplified in a 2-step wide-band amplifier to the level essential to the adjustment electronics. The normalized acceleration signal is adjusted in a band-pass (high/low pass combination) to the specific machine requirements regarding the frequency range to assess. With DIL-switches is determined, which of the two possible units velocity or displacement is used for Vibration Monitoring. The DC-output signal (voltage or current) available after the following rectifying (true RMS rectifier) is calibrated in RMS units. The DC-output signal acts on the two adjustable level detectors. The response delay of the appropriate assigned relays is set by DIL-switches to 1, 3, 5 or 10s. The assigned relays change-over contacts enable the alarm and trip circuits, responding either on opening or on closing the contact. It can be selected between normally energized and normally de-energized by Dil-Switches. Technical Information Power supply for each channel Input circuit Sensors Amplifier RAW Signal Frequency range Measuring units 115/230 V AC (-10/+15 %) 50/60 Hz Approx. 7 VA +18...36 V DC or +36 60 V DC optional Approx. 10 W - input amplifier (mv/mm/s) with linearization - input amplifier (mv/g) with constant current source (0,5/4mA) - input amplifier (mv/g) with auxiliary voltage for GSI CV... velocity transducer Signal mv/mm/s CE... accelerometer for constant current supply mv/g CE... accelerometer with current modulating output Signal µa/g(only with GSI) CA... accelerometer with charge output Signal pc/g AC - amplifier 3Hz... 5kHz (not filtered), loaded with 20 kω High-pass HP: 3 Hz or 10 Hz Low-pass LP: 100 or 1000 Hz Filter (Butterworth 2 Pol; 40 db / Decade) selected by DIP Switches V => velocity mm/s eff S => displacement µmp Meggitt GmbH/ Version 5 / 01.16 / E 2 / 10
Measuring range DC output selected by DIP Switches Velocity 10, 20, 50 mm/s eff or displacement 100, 200, 500 µmp 0... +10V, R Last >10 kω or 0/4..20mA R Last < 500 Ohm Power supply for external devices Level switches Time delay Relay contact + 24 V DC Tolerance ± 1 % ; max.125 ma ; Noise level max.50 mv pp 2 pieces, independent adjustable in range of 10-100% (1V to 10VDC) selected by DIP switches; 1,3, 5 or 10 seconds max. switching voltage 220 V DC or 250 VAC max. switching current 2 A max. 60W or 125 VA Version: Aluminium Housing Temperature range: Humidity -20... +70 C operating temperature -30... +80 C storage temperature maximum humidity 95%, not condensing Housing Pressure cast aluminium, material GD AL Si 12 Dimensions Single 120 x 220 x 91 mm (H x B x T) Colour RAL 7001 Protection Class IP65 Connection Weight Dual 230 x 280 x 110 mm (H x B x T) Screwed cable gland M16x1,5 polyamide Single 3 pieces Dual 2 x 3 pieces Single 2 kg Dual 4 kg Version: Europa card Temperature range Format Dimensions Width Height Connection Weight 0... +50 C operating temperature -20... +80 C storage temperature European board 160 x 100mm 8 TE (40mm) front plate 3 HE Plug connector 32pol DIN 41612 design D approx. 0,45 kg Version: Sheet steel housing with LCD-Display Temperature range Humidity 0... +50 C operating temperature 0... +50 C storage temperature maximum humidity 95%, not condensing Meggitt GmbH/ Version 5 / 01.16 / E 3 / 10
Housing Sheet steel, powder coated Dimensions Single 150 x 300 x 128 mm (B x H x T) Dual 300 x 300 x 128 mm (B x H x T) Colour RAL 7035 Protection Class IP 66 Material thickness Technical design Connection Weight Housing: 1.38 mm ; Door: 1.25 mm Housing with hinged door; Lock with 3 mm double bit Screwed cable gland M16x1,5 polyamide Single 3 pieces Dual 2 x 3 pieces Single 3,5 kg Dual 6,0 kg Meggitt GmbH/ Version 5 / 01.16 / E 4 / 10
Drawings Single version with Aluminium housing Meggitt GmbH/ Version 5 / 01.16 / E 5 / 10
Dual version with Aluminium housing Meggitt GmbH/ Version 5 / 01.16 / E 6 / 10
Single version with sheet steel housing with LCD-Display Meggitt GmbH/ Version 5 / 01.16 / E 7 / 10
Dual version with sheet steel housing with LCD-Displays Meggitt GmbH/ Version 5 / 01.16 / E 8 / 10
Block diagram 19 (4a) 17 (8a) 16 (10a) RAW Signal 13 (16a) 70,7 mv/mm/s RMS 100 mv/mm/s p Messbereiche / Measuring ranges Messbereiche / Measuring ranges 10, 20, 50 mm/s eff 100, 200, 500 µm p 0V 0V pc/g Eingangsverstärker Input amplifier V Hochpass High-Pass V Tiefpass Low-Pass Verstärker Amplifier V Integrator ( x ) Pin - Europakarte F1: 115 VAC 100 mat 230 VAC 100 mat 24 VDC 500 mat 48 VDC 500 mat +15 V -15 V OK - System Rücksetzen Relais Reset Relays LCD Anzeige / Display 1999 Zeitverzögerung Delay 1, 3, 5, 10 s Selbst- / Nichtselbsthaltung Latched / Unlatched Arbeits- / Ruhestrom Normally Energized Normally De-Energized Zeitverzögerung Delay 1, 3, 5, 10 s Selbst- / Nichtselbsthaltung Latched / Unlatched Arbeits- / Ruhestrom Normally Energized Normally De-Energized Effektivwert-Gleichrichter RMS-Rectifier Verstärker Amplifier F1 Netzteil Power Supply +24V / 125 ma PE... 0V OK - System LED Grün Green Relay K 3 P 1 Grenzwertschalter Leveldetector LED Alarm Gelb Yellow MP 1 MP 2 1... 10 V 10... 100 % Relay K 1 P 2 1... 10 V 10... 100 % Grenzwertschalter Leveldetector LED Danger Rot Red Relay K 2 U U/I - Umsetzer U/I - Converter 0... +10 V 0/4... 20 ma 1 (32c) 2 (30c) 3 (28c) 20 (2a) 18 (6a) 11 (18a) 12 (18c) 10 (20c) 8 (22a) 9 (22c) 7 (24c) 5 (26a) 6 (26c) 4 (24a) 15 (12a) Drawn Name Block Diagram Absolut Vibration 01.01.2011 Henrichs valid from 31.12.2011 Display 08.01.2016 Vibro-Meter GmbH Nullpunkt Offset P 3 0V GND 14 (10c) f f I f Earth Meggitt GmbH/ Version 5 / 01.16 / E 9 / 10
VMD VMS830- VMD VMS830-2 For Dual channel A B C D E F G H I J version (A) 19 European card 01 Aluminium housing 02 Circuit board 03 Sheet steel housing 04 input (B) pc/g 01 mv/g 02 µa/g 03 mv/mm/s 04 input sensitivity (C) high-pass filter (D) 3 Hz 03 10 Hz 10 LCD display (J) without 0 with * 1 BNC connector (I) 0 without 1 with power supply 024 24 VDC 048 48 VDC 115 115 VAC 230 230 VAC Sensor sensitivity xxx U / I output (G) 0 0 20 ma 4 4 20 ma 10 0 10 V DC low pass filter (E) 100 Hz 0100 1000 Hz 1000 Mesurement range (F) velocity 10 10 mm/s eff 20 20 mm/s eff 50 50 mm/s eff displacement 100 100 µmp 200 200 µmp 500 500 µmp (H) * LCD-display only available in combination with sheet steel housing Example: VMD-VMS830-A04-B01-C100-D10-E1000-F20-G4-H230-I0-J1 (VMS830-2 for DUAL channel instrument) Version (A04): Sheet steel housing Input (B02): mv/g Input sensitivity (C100): 100 HP high-pass filter (D10): 10 Hz TP low pass filter (E1000): 1000 Hz Measuring range (F20): 20 mm/s eff Current output (G4): 4 20 ma Power supply (H230): 230 V AC BNC connector (I0): none LCD display (J1): with LCD display Rights reserved to make changes without prior notification. Sales Offices Your local representative Meggitt GmbH The complete list can be found on our webpage www.meggitt.com Kaiserleistraße 51 63067 Offenbach am Main Deutschland / Germany Tel.+49 (0) 69 9799050 Fax +49 (0) 69 97990526 E-Mail: info@meggitt.de www.meggitt.de Meggitt GmbH/ Version 5 / 01.16 / E 10 / 10