Input Modules for TESLA Power System Recorders

Similar documents
MCTS II Multi Channel Current Transducer System. Installation Manual

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

CPCO Series DC-AC Current Probe, Clamp On, 160mm, ±1000A ±2000A ±4000A ±8000A ±12000A, ±16000A

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

TPS TRANSDUCER POWER SUPPLY & LEM IT CURRNET TRANSDUCER

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

ELKOR MOC1 TRANSDUCER SET - MANUAL

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DP2000 ORDERING GUIDE To Order MODEL NO.

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Data Sheet. Hall effect transducers, current and voltage

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

Efficient Energy Systems 3315ENG.

CSG110 Strain Gauge Universal Amplifier

Linear Current Sensor with differential outputs

Signal Conditioning Amplifier

CYHCS-RC2S Split Core Hall Effect DC Current Sensor

Model 931A Power System Analyzer. Model 930A Three Phase Power Analyzer. Model 929A Three Phase Power Meter. with. Digital Signal Analysis

current transformers or VAC secondary voltage from our SIGNAL CONVERTERS Selection Chart

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.

IAA100/IAA200 Analog Amplifiers Voltage/Current

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

PRECISION CLAMP ON FLEXIBLE ROGOWSKI COIL CURRENT TRANSFORMER

SPIDER-80SG. General Data Acquisition Device with Strain Gage Measurement. Spider Measurement Solution

DC Current Transducers

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

AAA Balanced / Unbalanced Line Audio Interface Amplifiers. User Manual. I.R.T. Communications Pty Ltd

MODEL AT-10 ANALOG TRANSMITTER

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Tel: (949) Fax: (949) IAA100 Product Manual

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

DRG-SC Series Signal Conditioners

sch-remote.com EVOR04 Application note: Measure power

Economical Digital Indicators For Process and Electrical Measurement

N. TEST TEST DESCRIPTION

LAUREL ELECTRONICS, INC.

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

AC FLEXIBLE CURRENT PROBE CA 3000

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Digital Sampling Power Meter. Digital Power Meter and Power Analyzer WT210/WT230 WT1600 WT2010/WT2030 PZ4000

22 kw 4Q POWER AMPLIFIER RS232

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

OHIO SEMITRONICS, INC. WATT / Wh / VAR / VARh TRANSDUCER OSI SPECIFICATIONS

N. TEST TEST DESCRIPTION

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

Acuvim IIBN Series BACnet Power Meter

Models 900CT & 900BT. Tunable Active Single Channel Certified Filter Instrument

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

Current transducer FHS 40-P/SP600

CAH CARD. user leaflet. 1 of 15. Copyright Issue 12.1 January 2015

CMC 256plus - protection relay test set and universal calibrator

LKAT2 Portable. High Current, Portable, Multi-size Head AC / DC Current Measurement System. Application Examples. Key Features

SC-FI Series Frequency to Current Signal Conditioner

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

Model PA3000 Power Analyzer

TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

CAP6637A AC-DC Open Loop Converter

Current clamps for AC current

Current Transducer CTSR 1-P = 1A

269 Troubleshooting Guide 11/4/98 1

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

TV31 Voltage/ Current Transformer

Product Specification

DOCUMENTATION. Its affordable price allows you to meet your budget target.

Installation and Operating Manual

ELECTRICAL VARIABLES How Split-Core Type Transformers Work. How Optical Probes for Current Meters Work. Current Meter Scanning à la ALMEMO

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

IB6 Series Solid-State Isolation Relay

LV3-8 for imc CRONOS-PL/-SL/compact

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Current Probes. User Manual

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

PM50. Technical Data TECHNOSOFT. DSP Motion Solutions. Power Module for DC, Brushless DC and AC Motors. Version 3.0. PM50 v3.0.

Sefram. Sefram SEFRAM A new family of thermal recorders 6 to 36 channels. Make sure to visit our Website

AC/DC Current Oscilloscope Probe Model SL261

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

VC-4/4A, VC-8/8A, VC-16

ART500A SPEAKER ART500A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

VC-4/4A, VC-8/8A, VC-16 4/8/16-Channel PCM and ADPCM Voice Modules

BE1-87G VARIABLE PERCENTAGE DIFFERENTIAL RELAY

WATT TRANSDUCER. Instruction Manual

ART300A SPEAKER ART300A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Experiments #7. Operational Amplifier part 1

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

Measuring current transformers of the W, W series

Transcription:

Input Modules for TESLA Power System Recorders Modules Described In This Document DC Isolation Input Module - Model 401016 Input (ac or dc signals) AC Current Module - 5 A, new model 110739, old model 101754-1 A, new model 110748, old model 101955 AC Voltage Input Module - Model 401006 Split Core Current Transformer - Model 401013 (5 A) and 401017 (1 A) Clamp On Current Transformer - Model 401012 10 Year WARRANTY

DC Isolation Input Module Model 401016 Input (ac or dc signals) The dc input module provides dc-coupled isolation and scaling for four independent dc or ac voltage or current channels. These channels have a bandwidth from dc to 2 khz but are limited to 1.5 khz by anti-aliasing inside the recorder. Externally mounted resistors set the input type and full scale range of the module. The output signals from the module provide isolation and conditioning for the TESLA disturbance fault recorder analog input channels. Note: Locate modules up to 1200 meters (4000 ft) from the recorder. Specs Input Voltage Low range 0.1 to 200 Vdc full scale 0.1 to 150 Vrms full scale High range 350 V to 1000 Vdc full scale 200 V to 600 Vrms full scale Current (ac or dc shunt outputs) Direct input from transducers 1 to 500 ma dc full scale ac or dc from high current shunts (mv) 0.1 to 1000 mv (ac or dc) across the shunt Ratio (1 kω load) Dependent on confi guration Input Impedance Dependent on confi guration Power Supply 40 V to 300 Vdc or 120 Vac Isolation Channel to Ground 1500 V Channel to Channel 1500 V Dimensions: L x W x H 172mm x 113mm x 67.2mm In case of inconsistencies between documents, the version at will be considered correct. (D02366R09)

AC Current Module 5 A Input Module new model # 110739, old model #101754 1 A Input Module new model #110748, old model #101955 The ac current input module provides four isolated current channels for TESLA Disturbance Fault Recorder. These current modules are available in 1 A nominal and 5 A nominal versions. The current modules provide conditioning and isolation between the main CT secondaries and the inputs to the recorder. Apply the nominal phase current (In) 5 A or 1 Arms into the odd numbered input terminals with the dot (indicating ac instantaneous polarity) and out of the even numbered terminal for each current input. 1. The output from the current module to the input of the recorder is an impedance-matched loop. Due to impedance matching requirements, the modules output channels cannot be connected to more than one TESLA Disturbance Fault Recorder input channels. Specs 5 A 1 A Nominal Current - 4 input channels Full Scale/Continuous Maximum Over-scale In = 5 Arms 3x In = 15 Arms 20x = 100 Arms for 1 second (no distortion) In = 1 Arms 3x In = 3 Arms 20x = 20 Arms for 1 second (no distortion) Thermal Rating 80x = 400 Arms for 1 second 400x = 400 Arms for 1 second Burden <0.25 VA @ 5 Arms <0.25 VA @ 5 Arms Ratio (1 kω load) 79 mv/a 15.8 mv/a Dimensions: L x W x H 172mm x 113mm x 67.2mm 172mm x 113mm x 67.2mm AC Current Input Module Part Numbers Type Old Part Number New Part Number 5 A CT Module Part Number 101754 (Model 401014) 1 A CT Module Part Number 101955 (Model 401020) Part Number 110739 (Model 110739) Part Number 110748 (Model 110748) In case of inconsistencies between documents, the version at will be considered correct. (D02364R12)

AC Voltage Input Module Model 401006 The ac voltage input module (Model 401006) provides three isolated voltage channels for TESLA Disturbance Fault Recorder. These voltage modules provide conditioning and isolation between the main PT/VT secondaries and the inputs to the recorder. Apply the nominal phase to ground voltage (Vn) - 69 Vrms - across one input to the module with a dot on the odd numbered input terminals indicating ac instantaneous polarity reference. Notes: 1. The output from the voltage module to the input of the recorder is an impedance-matched loop. Due to impedance matching requirements, the modules output channels cannot be connected to more than one TESLA Disturbance Fault Recorder input channels. Specs Nominal Voltage - across input channels Full Scale/Continuous Maximum Over-scale Thermal Rating Vn = 69 Vrms 2x VN = 138 Vrms 3x Vn = 207 Vrms for 10 seconds Burden <0.15 VA @ 69 Vrms Ratio (1kΩ load) 12.14 mv/v Dimensions: L x W x H 172mm x 113mm x 67.2mm In case of inconsistencies between documents, the version at will be considered correct. (D02365R09)

Split Core Current Transformer Model 401013 (5 A) and 401017 (1 A) The split core transformer measures current in a 5 A or 1 A secondary CT circuit and works in conjunction with the TESLA disturbance fault recorder to monitor secondary currents. It is designed to clamp around the secondary circuit wires from the primary CT and is intended to connect an in-line CT for situations which do not allow an open-circuit. The on load installation does not require the main CT to be taken out of service during testing. The secondary current circuit wire can be placed in the split core and the removable leg screwed back on the split core CT. The spring-loaded leg will mate with the core of the main housing (split core). The outputs from the CT are scaled and impedance matched to connect directly to the TESLA s analog input connectors. Notes: 1. Due to impedance matching requirements, the CT cannot be connected to more than one TESLA input channel. Specs Model 401013 (5 A) Model 401017 (1 A) Nominal Current In = 5 Arms In = 1 Arms Full Scale/Continuous 3x In = 15 Arms 3x In = 3 Arms Maximum Over-scale 20x = 100 Arms for 1 second (no distortion) 20x = 20 Arms for 1 second (no distortion) Thermal Rating 80x = 400 Arms for 1 second 400x = 400 Arms for 1 second Burden <0.25 VA @ 5 Arms <0.25 VA @ 5 Arms Ratio (1 kω load) 15.8 mv/a 79 mv/a Ratio/Linearity Accuracy 0.5% full scale, +/-0.5% range Phase Displacement or Shift 0.25 or less @ 60Hz Phase Connection Relationship White wire positive with arrow towards source of current In case of inconsistencies between documents, the version at will be considered correct. (D02368R11)

Clamp On Current Transformer Model 401012 The clamp-on CT works in conjunction with the TESLA disturbance fault recorder to monitor secondary current from the main CTs. The device has a clothes-pin style jaw mechanism designed to clamp around the secondary circuit wires from the primary CTs and is intended for quick, temporary connection during testing, and installation of high voltage power equipment.the on load installation does not require the main CT to be taken out of service during testing. The jaws can accommodate conductors up to 250 MCM. The Clamp-on CT is scaled for a 5 A nominal current with a dynamic range that can pass 20x nominal currents continuously. The outputs from the CT are scaled and impedance matched to connect directly to the TESLA s analog input connectors. Notes: 1. Due to impedance matching requirements, the CT cannot be connected to more than one TESLA input channel. Specs Nominal Current In = 5 Arms Full Scale/Continuous 3x In = 15 Arms Maximum Over-scale 20x = 100 Arms for 1 second (no distortion) Thermal Rating 80x = 400 Arms for 1 second Burden <0.25 VA @ 5 Arms Ratio (1 kω load) 79 mv/a ERLPhase Power Technologies Tel: 204-477-0591 Email: info@erlphase.com In case of inconsistencies between documents, the version at will be considered correct. (D02367R09)