E-STOP relays, safety gate monitors

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

PNOZ X3. } Safety relays. Operating Manual EN-08

PNOZ X2.7P. } Safety relays. Operating Manual EN-19

Datasheet - PROTECT-IE-02

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

02/11/2015

02/11/2015

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

02/11/2015

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

PSR-SCP- 24DC/ESD/5X1/1X2/300

Type CP-S, CP-C & CP-A Switch mode

02/11/2015

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker ESS20-0..

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Operating instructions Fail-safe delay timer AZS About this document. Content

38 Series - Relay interface modules A

Safety switches with slotted hole lever

38 Series - Relay interface modules A

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Installation / Monitoring Technique

05/09/2012

Components for safety applications Preventa safety modules

Electronic Circuit Protector ESX10-T

Electronic Circuit Breaker ESS1 for System SVS1

38 Series - Relay Interface Modules A

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

38 Series - Relay interface modules A. Features /

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

New Products Catalogue 2009 Safety Relays ESR5

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

02/11/2015

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

Datasheet. Electronic Circuit Protection ESX10-T

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

Safety relays - PSR-SCP- 24DC/ESD/4X1/

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

MINI-PS AC/24DC/1.3

Technical features table for miniature circuit-breakers SH 200 Series

Subject to changes 11/2003 Page 1/7

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Electronic timer CT-TGD.22

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

FM series position switches

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay LG 5928

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

MINI-PS AC/2X15DC/1

PHOENIX CONTACT - 09/2009

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Control module CP-A CM

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

Electronic timer CT-SDD.22

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

Controls Contactors and Contactor Assemblies Special Applications

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Measuring current transformers of the W AB(P) series

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

48 Series - Relay interface modules A. Features

Installation and Operational Instructions for ROBA -multiswitch Type 019._00.2

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

62 Series - Power relays 16 A. Features / /

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

PHOENIX CONTACT

Protection components

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Transformers, Power Supply Units and Socket Outlets

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

IMPULSE SWITCH, REMOTE SWITCH

3 - Protection components Circuit-breakers

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Contactors and Contactor Assemblies

QUINT-PS-24DC/24DC/10

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

P RODUCT C ATALOGUE 1/2002

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

08/07/2015

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Transcription:

Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 2 auxiliary contacts (N/C), instantaneous 2 semiconductor outputs Connection options for: E-STOP pushbutton Safety gate limit switch Light barriers Reset button LED indicator for: Switch status channel 1/2 Input circuits Supply voltage Reset circuit Semiconductor outputs signal: Switch status channel 1/2 Supply voltage is present Plug-in connection terminals (either spring-loaded terminal or screw terminal) See order reference for unit types ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Sicherheitseigenschaften Zusatz - Sicherung DC_PNOZ The unit has an electronic fuse. Zulassungen Order no. 777607 is without approval Block diagram Unit description Bestimmung/Gertebeschreibung NOT-AUS, Schutzt, Lichtschr_PNOZ The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates Light beam devices Blockschaltbild A1 (B1) A2 (B2) 3 7 13 23 33 43 53 63 73 81 91 = (~)* = Input Input Input Reset/ Start K1 Power K2 Feedback 0 V 24 V/ 12 V K3 Y1 Y2 Y30 Y31 Y32 Y35 14 24 34 44 54 64 74 82 92 *Only applies when U B = 100-240 VAC

Function description ][Funktionen_einkanalig Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. ][Funktionen_zweikanalig_ohne_quer Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, short circuits in the input circuit and, with a monitored reset, in the reset circuit too. ][Funktionen_zweikanalig_mit_quer_ber Timing diagram Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, short circuits in the input circuit and, with a monitored reset, in the reset circuit too, shorts between contacts in the input circuit. ][Funktionen_autoStart Automatic start: Unit is active once the input circuit has been closed. ][Funktionen_manuStart Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ][Funktionen_berStart_allg Monitored reset: Unit is active once the input circuit is closed and then the reset circuit is closed and opened again. the reset circuit is closed and then opened again once the input circuit is closed. ][Funktionen_Kontaktvervielfachung Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors. ][Zeitdiagram_auto_manu_ueber1_aux_semiRUN_semiCH 1 2 3 a b a b POWER Reset/Start Input Output safe Output aux. Out semi RUN Out semi CH t1 t2 t1 t2 t1 t2 t1 t2 t1 t2 t1 t2 t3 Key Power: Supply voltage Reset/Start: Reset circuit 3- Input: Input circuits -, -, Output safe: Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 Output aux: Auxiliary contacts 81-82, 91-92 Wiring ][Verdrahtung_Si_Hi_unverz Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 are safety contacts, outputs 81-82, 91-92 are auxiliary contacts (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Out semi RUN: Semiconductor output supply voltage Y35 Out semi CH: Semiconductor output switch status Y32 : Automatic reset : Manual reset : Monitored reset a: Input circuit closes before reset circuit Calculation of the max. cabling runs l max in the input circuit: I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation t 3 : Recovery time Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. -2

Preparing for operation Betriebsbereitschaft herstellen Supply voltage Supply voltage AC DC U B = 12 VDC/24 VDC/100 240 VAC A1 A2 L1 N B1 L+ PE B2 L- U B = 12 VDC/24 VDC A1 L+ A2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts E-STOP with detection of shorts across contacts Safety gate without detection of shorts across contacts S2 Safety gate with detection of shorts across contacts S2 Light beam device with detection of shorts across contacts via ESPE 24 V DC GND

Reset circuit Reset circuit Automatic reset E-STOP/safety gate wiring (single-channel and dual-channel without shorts across contacts) 3 E-STOP/safety gate wiring (dual-channel with shorts across contacts) Manual reset 3 Monitored reset 3 Y1 7 Y1 7 Feedback circuit Feedback circuit Contacts from external contactors Y1 Y2 13 (23... 73) 14 (24... 74) K5 K6 K5 K6 L1 N Semiconductor output Y31 Y32 Y35 Y30 24 V DC/12 V DC SPS Input SPS Input 0 V Key /S2 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration Klemmenbelegung U B = 12 VDC/24 VDC Y1 Y2 P3 A1 3 3 81 81 91 13 23 33 43 53 63 73 P4 P5 POWER START IN - IN - CH. 1 - OUT CH. 2 - OUT 81 81 91 13 23 33 43 53 63 73 82 82 92 14 24 34 44 54 64 74 P4 P5 A2 Y1 7 82 82 92 14 24 34 44 54 64 74 P3 Y30 Y31 Y32 Y35 U B = 24 VDC/100-240 VAC Y1 Y2 P3 A1 B1 3 3 81 81 91 13 23 33 43 53 63 73 P4 P5 AC POWER START IN - IN - CH. 1 - OUT CH. 2 - OUT 81 81 91 13 23 33 43 53 63 73 82 82 92 14 24 34 44 54 64 74 20162 P4 P5 A2 B2 Y1 7 82 82 92 14 24 34 44 54 64 74 P3 Y30 Y31 Y32 Y35 Installation Montage_PNOZ_X The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions Abmessungen * with spring-loaded terminals 121 (4.76") 94 (3.70") 90 (3.54") * 101 (3.98")

Notice ][WICHTIG_PDB_alt This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) ECorriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC1: 230 V DC13: 24 V Lebensdauerkurve AC15: 230 V DC1: 24 V AC1: 400 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 ENúmero de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœuvres x 10 3 NL Aantal schakelingen x 10 3 ][Technische Daten PNOZ Technical details Electrical data Supply voltage Supply voltage U B AC 100-240 V Supply voltage U B DC 12 V, 24 V Voltage tolerance -15 %/+10 % Order no.: 777606, 777609, 787606, 787609-20 %/+20 % Order no.: 777607 Power consumption at U B AC 8.5 VA Order no.: 777606, 787606 Power consumption at U B DC 5.5 W Order no.: 777606, 777609, 787606, 787609 7.0 W Order no.: 777607 Frequency range AC 50-60 Hz Residual ripple DC 160 % Voltage and current at Input circuit DC: 12.0 V Order no.: 777607 130.0 ma Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 50.0 ma Order no.: 777606, 777609, 787606, 787609 Reset circuit DC: 12.0 V Order no.: 777607 100.0 ma Order no.: 777606, 777609, 787606, 787609 24.0 V Order no.: 777606, 777609, 787606, 787609 200.0 ma Order no.: 777607 Feedback loop DC: 12.0 V Order no.: 777607 100.0 ma Order no.: 777606, 777609, 787606, 787609 24.0 V Order no.: 777606, 777609, 787606, 787609 200.0 ma Order no.: 777607 Number of output contacts Safety contacts (S) instantaneous: 7 Auxiliary contacts (N/C): 2 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Auxiliary contacts: AC15 at 230 V I max : 5.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Contact material AgSnO2 + 0.2 µm Au -6

Electrical data External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Auxiliary contacts: 10 A Blow-out fuse, slow Safety contacts: 6 A Auxiliary contacts: 6 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Auxiliary contacts: 6 A Semiconductor outputs (short circuit proof) 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 DC,20 ma External supply voltage 12.0 V Order no.: 777607 24.0 V Order no.: 777606, 777609, 787606, 787609 DC Voltage tolerance -20 %/+20 % Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 45 Ohm Order no.: 777606, 777609, 787606, 787609 8 Ohm Order no.: 777607 single-channel at U B AC 45 Ohm Order no.: 777606, 787606 dual-channel without detect. of shorts across contacts at U B DC 15 Ohm Order no.: 777607 90 Ohm Order no.: 777606, 777609, 787606, 787609 dual-channel without detect. of shorts across contacts at U B AC 90 Ohm Order no.: 777606, 787606 dual-channel with detect. of shorts across contacts at U B DC 15 Ohm Order no.: 777606, 777609, 787606, 787609 8 Ohm Order no.: 777607 dual-channel with detect. of shorts across contacts at U B AC 15 Ohm Order no.: 777606, 787606 Safety-related characteristic data PL in accordance with EN ISO 13849-1 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 t M in years 20 Times Switch-on delay with automatic reset typ. 130 ms Order no.: 777607 200 ms Order no.: 777606, 777609, 787606, 787609 with automatic reset max. 200 ms Order no.: 777607 250 ms Order no.: 777606, 777609, 787606, 787609 with automatic reset after power on typ. 150 ms Order no.: 777607 220 ms Order no.: 777606, 777609, 787606, 787609 with automatic reset after power on max. 220 ms Order no.: 777607 300 ms Order no.: 777606, 777609, 787606, 787609 with manual reset typ. 150 ms Order no.: 777607 200 ms Order no.: 777606, 777609, 787606, 787609 with manual reset max. 200 ms Order no.: 777607 250 ms Order no.: 777606, 777609, 787606, 787609 on monitored reset with falling edge typ. 100 ms Order no.: 777607 150 ms Order no.: 777606, 777609, 787606, 787609 on monitored reset with falling edge max. 150 ms Order no.: 777607 220 ms Order no.: 777606, 777609, 787606, 787609

Times Delay-on de-energisation with E-STOP typ. 20 ms with E-STOP max. 30 ms with power failure typ. 170 ms Order no.: 777606, 777609, 787606, 787609 60 ms Order no.: 777607 with power failure max. 250 ms Order no.: 777606, 777609, 787606, 787609 80 ms Order no.: 777607 with power failure typ. U B AC: 100 V, 100 V 165 ms Order no.: 777606, 787606 with power failure max. U B AC: 100 V, 100 V 200 ms Order no.: 777606, 787606 with power failure typ. U B AC : 240 V 320 ms Order no.: 777606, 787606 with power failure max. U B AC : 240 V 450 ms Order no.: 777606, 787606 Recovery time at max. switching frequency 1/s after E-STOP 50 ms after power failure 100 ms Order no.: 777607 300 ms Order no.: 777606, 777609, 787606, 787609 after power failure on universal power supply 500 ms Order no.: 777606, 787606 Min. start pulse duration with a monitored reset with falling edge 30 ms Order no.: 777607 50 ms Order no.: 777606, 777609, 787606, 787609 Simultaneity, channel 1 and 2 150 ms Order no.: 777606, 777609, 787606, 787609 50 ms Order no.: 777607 Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 4.0 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG Order no.: 777606, 777607, 777609 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG Order no.: 777606, 777607, 777609 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG Order no.: 777606, 777607, 777609 Torque setting with screw terminals 0.50 Nm Order no.: 777606, 777607, 777609 Cross section of external conductors with spring-loaded terminals: 0.20-1.50 mm², 24-16 AWG Order no.: 787606, 787609 Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 Order no.: 787606, 787609 Stripping length 8 mm Order no.: 787606, 787609-8

Mechanical data Dimensions Height 101.0 mm Order no.: 787606, 787609 94.0 mm Order no.: 777606, 777607, 777609 Width 90.0 mm Depth 121.0 mm Weight 570 g Order no.: 787609 575 g Order no.: 787606 580 g Order no.: 777607, 777609 585 g Order no.: 777606 Technische Daten_Satz Normen The standards current on 2006-06 apply. ][Dauerstrom_ACDC Conventional thermal current Number of contacts I th (A) at U B DC I th (A) at U B AC 1 8.00 A 8.00 A Order no.: 777606, 787606 2 8.00 A 8.00 A Order no.: 777606, 787606 3 8.00 A 8.00 A Order no.: 777606, 787606 4 7.00 A 7.00 A Order no.: 777606, 787606 5 6.00 A 6.00 A Order no.: 777606, 787606 6 5.50 A 5.50 A Order no.: 777606, 787606 7 5.00 A 5.00 A Order no.: 777606, 787606 Bestelldaten Order reference Type Features Terminals Order no. C 110-240 VAC 24 VDC Spring-loaded terminals 787 606 110-240 VAC 24 VDC Screw terminals 777 606 C 24 VDC Spring-loaded terminals 787 609 24 VDC Screw terminals 777 609 12 VDC Screw terminals 777 607