UV-Index Photodiodes Data Sheets

Similar documents
UV-Index Photodiodes Data Sheets

Ultraviolet (UV-Index) TOCON Datasheets

SiC UV Photodiodes Catalog

Content of this Catalog. General information about the sglux TOCONs. Selection guide p. 2. Product details of all TOCONs p. 5. Useful accessories p.

UV-A, UV-B & UV-I Sensors

Ultraviolet selective thin film sensor TW30DY NEW: Read important application notes on page 4 ff.

INDIUM SENSOR. Type X.5 Series

The Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

Measuring the Performance of UV LED Light Sources

Advances in Measuring UV LED Arrays

Improved Radiometry for LED Arrays

Signal out Ranges Setting facilities U supply. 3 ranges configurable with jumpers. continuously adjustable amplification with potentiometer

CIE 220:2016 Characterization and Calibration Method of UV Radiometers

Light Sensors for Environmental Chambers

ISO Determination of sunscreen UVA photoprotection in vitro. Détermination in vitro de la photoprotection UVA. First edition

P-CUBE-Series High Sensitivity PIN Detector Modules

USER MANUAL MODEL 501-DA ANALOG UV BIOMETER SENSOR. Part Number: Revision Level: A

REPORT OF CALIBRATION of One Standard of Spectral Irradiance ( nm)

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

UV Measurement. Information Sheet. Dipl.-Ing. Andreas Renzel. Basics of UV measurement and solutions for UV curing applications.

Influence of the light spectral distribution used in the radiometers calibration

HD HD HD AND HD PHOTO-RADIOMETERS LG-2

Package photobiologysensors

EIT Instrument Markets Product Overview

Broadbandradiometer specbos 1211

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

UV-dose indicator formulations as paint-onphotodetectors: way to optimize the UV curing process

This document is a preview generated by EVS

Detector-Filter Combination Series

INSTRUCTION MANUAL UV RADIOMETERS

Experiment E-6 Rayleigh Scattering

The Standard for over 40 Years

InGaAs Avalanche Photodiode. IAG-Series

SPECTRAL IRRADIANCE DATA

Ground-Based Solar UV Radiation Monitoring Technique Using Photocell. Pulchowk Campus, Institute of Engineering, Tribhuvan University, Nepal

Ultra High Power 980nm Pump Laser Module - Grating Stabilized, 750mW

A stray light corrected array spectroradiometer for complex high dynamic range measurements in the UV spectral range.

Photo-Documentation of Ultraviolet Radiation Induced Visible Fluorescence on Daguerreotypes

LP PHOT 03 LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03

Model #2 UVB Midband Ultraviolet Lamp Assembly with Timer

[MILLIMETERS] INCHES DIMENSIONS ARE IN:

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Contact person Date Reference Page Stefan Källberg MTt6F (4) Measurement Technology

Multi-Lamp Microwave UV Systems Physics and Technology

UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells

655 nm Precision Optical Reflective Sensor Technical Data

Photops. Photodiode-Amplifier Hybrids

Red/Far-Red Sensor SKR 110. Skye Instruments Ltd., 21 Ddole Enterprise Park, Llandrindod Wells, Powys LD1 6DF UK Tel: +44 (0)

LP UVA 02. REV jan. 2007

The use of ultraviolet (UV) energy

Silicon Photodiode, RoHS Compliant

Application Note (A16)

Silicon Avalanche Photodiode SAR-/SARP-Series

apogeeinstruments.com Introducing the PV-100 PV Monitoring Package

680nm Quasi Single-Mode VCSEL Part number code: 680Q-0000-X002

New applications are transforming the UV-LED market, and Nikkiso Deep UV-LED devices are applicable to many important applications including:

Introduction. UV Sterilization System Dimension 3.5mm* 3.5mm* 3.5mm. UV Photo-catalyst ESD protection up to 8KV. UV Sensor Light RoHS compliant

GLOSSARY OF TERMS. Terminology Used for Ultraviolet (UV) Curing Process Design and Measurement

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Diode capacitance V R = 0 V, f = 1 MHz, E = 0 C D 1.2 nf V R = 5 V, f = 1 MHz, E = 0 C D 400 pf Dark Resistance V R = 10 mv R D 38 GΩ Optical

REVISITING POTENTIAL HAZARD OF LED SOURCES TO CAUSE BLH IN SPECIFIC POPULATION

Spectroradiometer specbos 1201

LP PYRA 06. REV Jan. 2007

2 Channel Light Sensor

Ambient Light Sensor

LP RAD 03 LP PAR 03 LP UVA 03 LP UVB 03 LP PHOT 03S

Silicon PIN Photodiode

AAA3528AVU/AZGKSYKCT. Single Level Surface Mount CBI DESCRIPTIONS PACKAGE DIMENSIONS FEATURES APPLICATIONS ATTENTION SELECTION GUIDE

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Through Hole Lamp Product Data Sheet LTL-1CHE-012A Spec No.: DS Effective Date: 10/31/2003 LITE-ON DCC RELEASE

PD438B/S46 Features Descriptions Applications Device Selection Guide Chip LED Part No. Lens Color Material

High quality Full Sale or Return 7 Price points, RRPs ranging from lines and 3 styles; Classic, Sporty and Trendy

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

PHOTODIODE WITH ON-CHIP AMPLIFIER

SAFE USE &OPERATIONS MANUAL

Through Hole Lamp Product Data Sheet LTL-4231N-002 Spec No.: DS Effective Date: 03/25/2000 LITE-ON DCC RELEASE

Advanced Radiachromic Radiometry for UV Curing

LP UVA Introduction. 2 Working Principle. TEL r.a. FAX

Silicon Avalanche Photodiode SAE-Series (NIR-Enhanced)

LI-192 Underwater Quantum Sensor

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

APHF1608SEEQBDZGKC. 1.6 x 0.8 mm Full-Color Surface Mount LED

Data Sheet. MCSi. Integral 3-Element Colour Sensor 1 FUNCTION 2 2 APPLICATION 2 3 FEATURES 2 4 CONSTRUCTION 2 5 MAXIMUM RATINGS / CHARACTERISTICS 3

Page 1 BIOIMAGER. Spectrophotometers. Toll Free: (855) BIO- IMAG / (855) , E: S:

Silicon PIN Photodiode, RoHS Compliant

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

INTEGRATED PHOTODIODE AND AMPLIFIER

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

First Sensor Evaluation Board Data Sheet Part Description MOD Order #

SPEC NO: DSAF1339 REV NO: V.9B DATE: NOV/10/2015 PAGE: 1 OF 6 APPROVED:

LITE-ON TECHNOLOGY CORPORATION

T-1 3/4 (5mm) FULL COLOR LED LAMP. Features. Descriptions. Package Dimensions

Optical Power Meter Basics

Ambient Light Sensor

Description. Kingbright

SPEC NO: DSAF1341 REV NO: V.7B DATE: AUG/20/2014 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

4.8mm Semi-Lens Silicon PIN Photodiode PD438B

LI-1500 Light Sensor Logger

Silicon PIN Photodiode

Transcription:

UV-Index Photodiodes Data Sheets For UV-Index measurement according ot CIE087, 3 % error only = most precise currently available detector, cosine corrected, different packagings, sorted by detector areas. 91 Boylston Street, Brookline, MA 02445 tel: (617)566-3821 fax: (617)731-0935 www.boselec.com boselec@boselec.com

SG01D-E18 (ERYCA_custom) General Features Properties of the ERYCA_custom photodiode DIN5050/ CIE087 UV-Index measurement with very small error < 3% TO18 hermetically sealed housing, 1 UVI (2,5 µw/cm2) 1,25 na Information about the UV-Index (UVI) The UV index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (fig. 1, black curve and fig. 2, formula 1). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) About the sglux ERYCA sensors The ERYCA is designed for accurate measurement of the UV-Index. ERYCA s error is <3% only which is sufficiently small for scientific and high performance commercial applications. The ERYCA is available as: ERYCA_custom (SG01D-E18) photodiode, 1,25nA/UVI (0,50mm 2 SiC detector chip) ERYCA_advanced (SG01L-E5) cosine corrected photodiode, 2nA/UVI (1,0mm 2 SiC chip) ERYCA_science (SG01XL-E5) cosine corrected photodiode, 8nA/UVI (4,0mm 2 SiC chip) TOCON_ERYCA pre-amplified cosine corrected hermetically sealed low noise sensor with 5-15V power supply and approx. 100mV/UVI voltage output (SiC detector chip) How ERYCA s <3% error is calculated? A good erythema sensor s response needs to follow the Erythema Action curve (fig 1) as close as possible. Additionally the visible blindness needs to be extremely high as the visible part of sun s radiation exceeds the erythema causing radiation by five orders of magnitude. ERYCA works with a 4H SiC detector chip providing a visible blindness of more than ten orders of magnitude. That means that absolutely no visible light interferes the sensors output value. Sensors with a visible blindness of less than six orders of magnitude are unsuited for UVI measurement even if they match with the CIE curve. ERYCA s curve (fig. 1, red curve) has a near perfect match from 295nm to 320nm. From 320nm a leakage of approx. 0,1% is seen. To find out how that leakage negatively influences the UVI measurement a closer look at different sun spectra (varying tilt angle and ozone layer thickness) is needed. Fig. 4 shows different sun UV spectra issued by the Swiss governmental institute of meteorology. In total nine different sun spectra calculating an UVI from 1,12 to 10,92 were used. For error calculation the different sun spectra were integrated with the Erythema action curve and subsequently the integral of the same spectra with ERYCA s response curve (fig. 2, formula 1 and 2) were calculated. Finally the error was calculated by using formula 3 (fig. 2). As shown by the blue curve (fig. 3) the error of all UVI is less than 3%. Rev. 1.3 specifications subject to change without notice Page 1 [4]

SG01D-E18 (ERYCA_custom) Fig. 1 Spectral Response Fig. 2 Calculation Formulae Fig. 3 Error Graph Fig. 4 Sun Spectra Issued by the Swiss Meteo Institute Rev. 1.3 specifications subject to change without notice Page 2 [4]

f SG01D-E18 (ERYCA_custom) Specifications Parameter Symbol Value Unit Maximum Ratings Operating Temperature Range T opt -55 +170 C Storage Temperature Range T stor -55 +170 C Soldering Temperature (3s) T sold 260 C Reverse voltage V Rmax 20 V General Characteristics (T=25 C) Active Area A 0,50 mm 2 Dark current (1V reverse bias) I d 2,5 fa Capacitance C 188 pf Short circuit (1 UVI) I 0 1,25 na Temperature coefficient Tc <-0,1 %/K Circuit Viewing Angle SG01D-E18 Drawing Rev. 1.3 specifications subject to change without notice Page 3 [4]

SG01D-E18 (ERYCA_custom) Application Note for Photodiodes For correct reading of the photodiode the current (and NOT the voltage) must be analyzed. This requires a short circuiting of the photodiode. Usual approaches are using a Picoamperemeter or a transimpedance amplifier circuit. To make the photodiode running reliably, in particular in harsh environment, EMC compatibility and protection against dust, water and mechanical influences is needed. Below listed modules base on a SiC photodiode and guarantee this protection and safety. TOCONs = UV Sensors with integrated amplifier SiC based UV hybrid detector with pre-amplifier (0-5V output), no additional amplifier needed, direct connection to controller, voltmeter, etc. Measures intensities from 1,8 pw/cm2 up to 18 W/cm2 UV broadband, UVA, UVB, UVC or Erythema measurements Upgrade to M12x1 housing with Hirschmann connector available Industrial UV probes Different housings e.g. with cosine response, water pressure proof or Sapphire windows Different electronic outputs configurable (voltage, current, USB, CAN, LAN) Laboratory Equipment & Calibration The below listed sglux products & services are helpful if you like to learn more about the UV radiation generated by your UV source: UV Radiometers for intensity check UV Dosimeters for dose control, e.g. curing applications UV Controllers to control lamps, valves etc. NIST and PTB traceable calibration for all sglux sensors Rev. 1.3 specifications subject to change without notice Page 4 [4]

SG01L-E5 (ERYCA_advanced) General Features Properties of the ERYCA_advanced photodiode DIN5050/ CIE087 UV-Index measurement with very small error < 3% TO5 housing, 1 UVI (2,5 µw/cm2) 2 na, cosine correction Information about the UV-Index (UVI) The UV index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (fig. 1, black curve and fig. 2, formula 1). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) About the sglux ERYCA sensors The ERYCA is designed for accurate measurement of the UV-Index. ERYCA s error is <3% only which is sufficiently small for scientific and high performance commercial applications. The ERYCA is available as: ERYCA_custom (SG01M-E18) photodiode, 0,5nA/UVI (0,20mm 2 SiC detector chip) ERYCA_advanced (SG01L-E5) cosine corrected photodiode, 2nA/UVI (1,0mm 2 SiC chip) ERYCA_science (SG01XL-E5) cosine corrected photodiode, 8nA/UVI (4,0mm 2 SiC chip) TOCON_ERYCA pre-amplified cosine corrected hermetically sealed low noise sensor with 5-15V power supply and approx. 100mV/UVI voltage output (SiC detector chip) How ERYCA s <3% error is calculated? A good erythema sensor s response needs to follow the Erythema Action curve (fig 1) as close as possible. Additionally the visible blindness needs to be extremely high as the visible part of sun s radiation exceeds the erythema causing radiation by five orders of magnitude. ERYCA works with a 4H SiC detector chip providing a visible blindness of more than ten orders of magnitude. That means that absolutely no visible light interferes the sensors output value. Sensors with a visible blindness of less than six orders of magnitude are unsuited for UVI measurement even if they match with the CIE curve. ERYCA s curve (fig. 1, red curve) has a near perfect match from 295nm to 320nm. From 320nm a leakage of approx. 0,1% is seen. To find out how that leakage negatively influences the UVI measurement a closer look at different sun spectra (varying tilt angle and ozone layer thickness) is needed. Fig. 4 shows different sun UV spectra issued by the Swiss governmental institute of meteorology. In total nine different sun spectra calculating an UVI from 1,12 to 10,92 were used. For error calculation the different sun spectra were integrated with the Erythema action curve and subsequently the integral of the same spectra with ERYCA s response curve (fig. 2, formula 1 and 2) were calculated. Finally the error was calculated by using formula 3 (fig. 2). As shown by the blue curve (fig. 3) the error of all UVI is less than 3%. Rev. 5.2 specifications subject to change without notice Page 1 [4]

SG01L-E5 (ERYCA_advanced) Fig. 1 Spectral Response Fig. 2 Calculation Formulae Fig. 3 Error Graph Fig. 4 Sun Spectra Issued by the Swiss Meteo Institute Rev. 5.2 specifications subject to change without notice Page 2 [4]

f SG01L-E5 (ERYCA_advanced) Specifications Parameter Symbol Value Unit Maximum Ratings Operating Temperature Range T opt -55 +170 C Storage Temperature Range T stor -55 +170 C Soldering Temperature (3s) T sold 260 C Reverse voltage V Rmax 20 V General Characteristics (T=25 C) Active Area A 1,00 mm 2 Dark current (1V reverse bias) I d 4 fa Capacitance C 200 pf Short circuit (1 UVI) I 0 2 na Temperature coefficient Tc <-0,1 %/K Circuit Viewing Angle Drawing Rev. 5.2 specifications subject to change without notice Page 3 [4]

SG01L-E5 (ERYCA_advanced) Application Note for Photodiodes For correct reading of the photodiode the current (and NOT the voltage) must be analyzed. This requires a short circuiting of the photodiode. Usual approaches are using a Picoamperemeter or a transimpedance amplifier circuit. To make the photodiode running reliably, in particular in harsh environment, EMC compatibility and protection against dust, water and mechanical influences is needed. Below listed modules base on a SiC photodiode and guarantee this protection and safety. TOCONs = UV Sensors with integrated amplifier SiC based UV hybrid detector with pre-amplifier (0-5V output), no additional amplifier needed, direct connection to controller, voltmeter, etc. Measures intensities from 1,8 pw/cm2 up to 18 W/cm2 UV broadband, UVA, UVB, UVC or Erythema measurements Upgrade to M12x1 housing with Hirschmann connector available Industrial UV probes Different housings e.g. with cosine response, water pressure proof or Sapphire windows Different electronic outputs configurable (voltage, current, USB, CAN, LAN) Laboratory Equipment & Calibration The below listed sglux products & services are helpful if you like to learn more about the UV radiation generated by your UV source: UV Radiometers for intensity check UV Dosimeters for dose control, e.g. curing applications UV Controllers to control lamps, valves etc. NIST and PTB traceable calibration for all sglux sensors Rev. 5.2 specifications subject to change without notice Page 4 [4]

SG01M-E18 (ERYCA_custom) General Features Properties of the ERYCA_custom photodiode DIN5050/ CIE087 UV-Index measurement with very small error < 3% TO18 hermetically sealed housing, 1 UVI (2,5 µw/cm2) 500 pa Information about the UV-Index (UVI) The UV index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (fig. 1, black curve and fig. 2, formula 1). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) About the sglux ERYCA sensors The ERYCA is designed for accurate measurement of the UV-Index. ERYCA s error is <3% only which is sufficiently small for scientific and high performance commercial applications. The ERYCA is available as: ERYCA_custom (SG01M-E18) photodiode, 0,5nA/UVI (0,20mm 2 SiC detector chip) ERYCA_advanced (SG01L-E5) cosine corrected photodiode, 2nA/UVI (1,0mm 2 SiC chip) ERYCA_science (SG01XL-E5) cosine corrected photodiode, 8nA/UVI (4,0mm 2 SiC chip) TOCON_ERYCA pre-amplified cosine corrected hermetically sealed low noise sensor with 5-15V power supply and approx. 100mV/UVI voltage output (SiC detector chip) How ERYCA s <3% error is calculated? A good erythema sensor s response needs to follow the Erythema Action curve (fig 1) as close as possible. Additionally the visible blindness needs to be extremely high as the visible part of sun s radiation exceeds the erythema causing radiation by five orders of magnitude. ERYCA works with a 4H SiC detector chip providing a visible blindness of more than ten orders of magnitude. That means that absolutely no visible light interferes the sensors output value. Sensors with a visible blindness of less than six orders of magnitude are unsuited for UVI measurement even if they match with the CIE curve. ERYCA s curve (fig. 1, red curve) has a near perfect match from 295nm to 320nm. From 320nm a leakage of approx. 0,1% is seen. To find out how that leakage negatively influences the UVI measurement a closer look at different sun spectra (varying tilt angle and ozone layer thickness) is needed. Fig. 4 shows different sun UV spectra issued by the Swiss governmental institute of meteorology. In total nine different sun spectra calculating an UVI from 1,12 to 10,92 were used. For error calculation the different sun spectra were integrated with the Erythema action curve and subsequently the integral of the same spectra with ERYCA s response curve (fig. 2, formula 1 and 2) were calculated. Finally the error was calculated by using formula 3 (fig. 2). As shown by the blue curve (fig. 3) the error of all UVI is less than 3%. Rev. 5.2 specifications subject to change without notice Page 1 [4]

SG01M-E18 (ERYCA_custom) Fig. 1 Spectral Response Fig. 2 Calculation Formulae Fig. 3 Error Graph Fig. 4 Sun Spectra Issued by the Swiss Meteo Institute Rev. 5.2 specifications subject to change without notice Page 2 [4]

f SG01M-E18 (ERYCA_custom) Specifications Parameter Symbol Value Unit Maximum Ratings Operating Temperature Range T opt -55 +170 C Storage Temperature Range T stor -55 +170 C Soldering Temperature (3s) T sold 260 C Reverse voltage V Rmax 20 V General Characteristics (T=25 C) Active Area A 0,20 mm 2 Dark current (1V reverse bias) I d 1 fa Capacitance C 75 pf Short circuit (1 UVI) I 0 500 pa Temperature coefficient Tc <-0,1 %/K Circuit Viewing Angle Drawing Rev. 5.2 specifications subject to change without notice Page 3 [4]

SG01M-E18 (ERYCA_custom) Application Note for Photodiodes For correct reading of the photodiode the current (and NOT the voltage) must be analyzed. This requires a short circuiting of the photodiode. Usual approaches are using a Picoamperemeter or a transimpedance amplifier circuit. To make the photodiode running reliably, in particular in harsh environment, EMC compatibility and protection against dust, water and mechanical influences is needed. Below listed modules base on a SiC photodiode and guarantee this protection and safety. TOCONs = UV Sensors with integrated amplifier SiC based UV hybrid detector with pre-amplifier (0-5V output), no additional amplifier needed, direct connection to controller, voltmeter, etc. Measures intensities from 1,8 pw/cm2 up to 18 W/cm2 UV broadband, UVA, UVB, UVC or Erythema measurements Upgrade to M12x1 housing with Hirschmann connector available Industrial UV probes Different housings e.g. with cosine response, water pressure proof or Sapphire windows Different electronic outputs configurable (voltage, current, USB, CAN, LAN) Laboratory Equipment & Calibration The below listed sglux products & services are helpful if you like to learn more about the UV radiation generated by your UV source: UV Radiometers for intensity check UV Dosimeters for dose control, e.g. curing applications UV Controllers to control lamps, valves etc. NIST and PTB traceable calibration for all sglux sensors Rev. 5.2 specifications subject to change without notice Page 4 [4]

SG01XL-E5 (ERYCA_science) General Features Properties of the ERYCA_science photodiode DIN5050/ CIE087 UV-Index measurement with very small error < 3% TO5 housing, 1 UVI (2,5 µw/cm2) 8 na, cosine correction Information about the UV-Index (UVI) The UV index is an international standard measurement of how strong the ultraviolet (UV) radiation from the sun is at a particular place on a particular day. It is a scale primarily used in daily forecasts aimed at the general public. The UV-Index is calculated by integrating the sun s UV spectrum multiplied with the Erythema action curve (fig. 1, black curve and fig. 2, formula 1). That integral is divided by 25 mw/m 2 to generate a convenient index value, which becomes essentially a scale of 0 to 10. The Erythema action curve is a wavelength resolved measure of the sunburn danger. It is maximised at 297nm (UVB) and then strongly decreases towards UVA radiation. Literature: A. F. McKinlay and B. L. Diffey, A reference action spectrum for ultraviolet induced erythema in human skin CIE Journal, 6-1, 17-22 (1987) About the sglux ERYCA sensors The ERYCA is designed for accurate measurement of the UV-Index. ERYCA s error is <3% only which is sufficiently small for scientific and high performance commercial applications. The ERYCA is available as: ERYCA_custom (SG01M-E18) photodiode, 0,5nA/UVI (0,20mm 2 SiC detector chip) ERYCA_advanced (SG01L-E5) cosine corrected photodiode, 2nA/UVI (1,0mm 2 SiC chip) ERYCA_science (SG01XL-E5) cosine corrected photodiode, 8nA/UVI (4,0mm 2 SiC chip) TOCON_ERYCA pre-amplified cosine corrected hermetically sealed low noise sensor with 5-15V power supply and approx. 100mV/UVI voltage output (SiC detector chip) How ERYCA s <3% error is calculated? A good erythema sensor s response needs to follow the Erythema Action curve (fig 1) as close as possible. Additionally the visible blindness needs to be extremely high as the visible part of sun s radiation exceeds the erythema causing radiation by five orders of magnitude. ERYCA works with a 4H SiC detector chip providing a visible blindness of more than ten orders of magnitude. That means that absolutely no visible light interferes the sensors output value. Sensors with a visible blindness of less than six orders of magnitude are unsuited for UVI measurement even if they match with the CIE curve. ERYCA s curve (fig. 1, red curve) has a near perfect match from 295nm to 320nm. From 320nm a leakage of approx. 0,1% is seen. To find out how that leakage negatively influences the UVI measurement a closer look at different sun spectra (varying tilt angle and ozone layer thickness) is needed. Fig. 4 shows different sun UV spectra issued by the Swiss governmental institute of meteorology. In total nine different sun spectra calculating an UVI from 1,12 to 10,92 were used. For error calculation the different sun spectra were integrated with the Erythema action curve and subsequently the integral of the same spectra with ERYCA s response curve (fig. 2, formula 1 and 2) were calculated. Finally the error was calculated by using formula 3 (fig. 2). As shown by the blue curve (fig. 3) the error of all UVI is less than 3%. Rev. 5.2 specifications subject to change without notice Page 1 [4]

SG01XL-E5 (ERYCA_science) Fig. 1 Spectral Response Fig. 2 Calculation Formulae Fig. 3 Error Graph Fig. 4 Sun Spectra Issued by the Swiss Meteo Institute Rev. 5.2 specifications subject to change without notice Page 2 [4]

f SG01XL-E5 (ERYCA_science) Specifications Parameter Symbol Value Unit Maximum Ratings Operating Temperature Range T opt -55 +170 C Storage Temperature Range T stor -55 +170 C Soldering Temperature (3s) T sold 260 C Reverse voltage V Rmax 20 V General Characteristics (T=25 C) Active Area A 4,00 mm 2 Dark current (1V reverse bias) I d 7 fa Capacitance C 1,5 nf Short circuit (1 UVI) I 0 8 na Temperature coefficient Tc <-0,1 %/K Circuit Viewing Angle Drawing Rev. 5.2 specifications subject to change without notice Page 3 [4]

SG01XL-E5 (ERYCA_science) Application Note for Photodiodes For correct reading of the photodiode the current (and NOT the voltage) must be analyzed. This requires a short circuiting of the photodiode. Usual approaches are using a Picoamperemeter or a transimpedance amplifier circuit. To make the photodiode running reliably, in particular in harsh environment, EMC compatibility and protection against dust, water and mechanical influences is needed. Below listed modules base on a SiC photodiode and guarantee this protection and safety. TOCONs = UV Sensors with integrated amplifier SiC based UV hybrid detector with pre-amplifier (0-5V output), no additional amplifier needed, direct connection to controller, voltmeter, etc. Measures intensities from 1,8 pw/cm2 up to 18 W/cm2 UV broadband, UVA, UVB, UVC or Erythema measurements Upgrade to M12x1 housing with Hirschmann connector available Industrial UV probes Different housings e.g. with cosine response, water pressure proof or Sapphire windows Different electronic outputs configurable (voltage, current, USB, CAN, LAN) Laboratory Equipment & Calibration The below listed sglux products & services are helpful if you like to learn more about the UV radiation generated by your UV source: UV Radiometers for intensity check UV Dosimeters for dose control, e.g. curing applications UV Controllers to control lamps, valves etc. NIST and PTB traceable calibration for all sglux sensors Rev. 5.2 specifications subject to change without notice Page 4 [4]