FDX60(M)(S)(-M) SINGLE OR DUAL RS232/RS422/RS485(2/4W) DATA TRANSCEIVER INSTALLATION AND OPERATION MANUAL

Similar documents
GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

RFL-SHFI-M Module. C37.94 Short Haul Fibre Interface For Milegate. User Manual

2-Slot Desktop Chassis (DC) Extended Temperature

SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data

RFL-SHFI and SHFI-2 Module. C37.94 Short Haul Fibre Interface for UMUX. User Manual

F290X / F293X FOM II Series Fiber Optic Isolator Technical Manual

Active UTP Transceiver Hub Installation Guide

3-FIBMB2 Fiber Optic Interface Module Installation Sheet

Since 1987 Developed, Created and Made in Spain NDR6 OPTIC DATA TRANSCEIVER

10/100BASE-TX to 100BASE-FX. Fast Ethernet Media Converter. Quick Installation Guide

TMX PRODUCT LINE: 4-Channel Multiplexer. CATEGORY: ISDN and T/E Carrier. S/T-Interface DS0, DS1, T1, E1, DS1C, T1C, DS2, T2, E2 FEATURES

F272xB Fiber optic 4-Wire Telephone/Audio Modem Technical Manual

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER

CXD-Q 8-Channel Amplifier

af i Instruction Manual MR-944C Four Channel Video Receiver With One Bi-Directional Multi-Protocol Data Channel american fibertek 11/30/2012 JPK

CFO900 Series. User Manual. Audio/Data/Current Loop Mux/Demux CSX111, CSX123 & CSX222. CFO CSX series user manual, , rev003

1000BASE-TX to 1000BASE-SX/LX Media Converter

Instruction Manual MT-945SL Four Channel Video Transmitter With Two Bi-Directional Data Channels

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

Instruction Manual RT-93285SL RR-93285SL Thirty-two Channel Video Multiplexer With Two Bi-directional Data Channels

Gear Assembly Removal

PelcoFiber Digital Fiber Optic Transmission

N ETWOR KS FHX 8-PORT FIBER ENCLOSURE USER MANUAL

Instruction Manual MX-480 Bi-directional Multi-Protocol Data

Signamax Connectivity Systems 100BaseTX/FX to 100BaseFX Converter Series

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

FIBER OPTIC ANTENNA LINK OFW-5800/GPS. Compatible with a Wide Range of GPS Receivers Architectures. Logistically Supported with COTS Hardware

User s Manual. VA700XD Series. Fiber Optic Baseband Video /Audio. Installation and User Guide

3U High, 19" Drive Rack

Data Isolation Cards. 2-Wire HDSL/56KBS Isolation Card P Wire HDSL/56KBS Isolation Card P30050

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Add/Drop Multiplexor/Demultiplexor

SERIES DL221 10/100 ETHERNET TRANSCEIVER USER MANUAL

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

HITEK POWER EG353 SERIES HIGH-STABILITY 35 KV HIGH VOLTAGE POWER SUPPLIES FOR PRECISION SEM E-BEAM APPLICATIONS

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

OV-1000TSC OV-1000TLC/ Base-T to 1000Base-SX/LX Gigabit Ethernet Media Converter. User s Manual

Time over Fiber. interfacility link systems

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount)

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

10/100Base. 100Base-FX Switching Converter. User s Manual

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

The Precision Spherical Dipole Source

TETRA 43x0 Four Channel Digital Video Multiplexer with Two-Way Audio, Data, and Ethernet

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Dynamic Fiber Conversion System, 10-GbE

MINICUBE TRANSCEIVERS FOR VIDEO & ETHERNET

Part Numbers. Fiber Driver - ST/DB25M FIBER DRIVER

LIEBERT ITA2 MBC Quick-Start Guide 60Hz, 208V, 8-10kVA, Three-Phase

A3422 XMTDR. Digital Return Optical Transmitter Module. Features

INSTRUCTION MANUAL. VHF dpmr REPEATER. ifr5000. UHF dpmr REPEATER. ifr6000

FOM-4SF Sync/Async Single Fiber Modem

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

Contents subject to revision without prior notice.

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

Installation Instructions

Using the Integrating Sphere in the Multiple Application Platform (MAP)

Instruction Manual MTX-8485 MRX-8485 Four Channel Video Multiplexer with Bi-directional Data

IS-3000 SERIES INFRARED SCANNER

Interface converter G kbit/sec

MAINTENANCE MANUAL FOR CONVENTIONAL NETWORK INTERFACE

BandMaster V Manual. Installation

SYSTIMAX 360 ipatch G2 Fiber Shelf with Faceplate Instructions

Video Data Power. HubWayEXP. UL Listed Sxteen (16) Channel UTP Power Injector. Installation Guide Z1409. More than just power. TM. Rev.

USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

Quick Guide. FCC/IC: MHz CE: MHz

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

Optiva 18 GHz Unamplified Microwave (MW) Transport System

SEL Radio Accessories Guide

W-DMX G4. BlackBox and WhiteBox F-1 BlackBox and WhiteBox R-512 BlackBox and WhiteBox F-2 Micro F-1 Lite Micro R-512 Lite ProBox F-2500.

SEL Radio Accessories Guide

GPS Time Server Product Specifications and Installation Data

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

11 GHz FDD Licensed Backhaul Radio. Model: AF 11FX

Installation Manual February Model 752E Phase Selector Model 754E Phase Selector Model 760E Card Rack Model 759 Auxiliary Interface Panel

CONTENTS. Introduction Characteristics Product range Pages

4Post and 2Post Rails for Dell PowerEdge R810

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

CLB-501B CAMERA LINK BREAKOUT BOX. User s Manual. Document # , Rev 0.2, 3/23/2012 preliminary

Analog Signal DIN Fiber Link System

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

Trendmaster * Dynamic Scanning Module

MODEL FLD-496SA 9600 Baud FIBER OPTIC/FSK MODEM

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

HARDWARE GUIDE. FlexIO Controller M2000 Series. Specifications and Operational Guide

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

Vega Reader Setup Guide

5 Mbit/s Repeater Carrierband to Single-mode Fiber Optic

RACKMUX-DRAWER Single-Person Installation Manual

Transcription:

(M)(S)(-M) SINGLE OR DUAL RS232/RS422/RS485(2/4W) DATA TRANSCEIVER The ComNet (M)(S)(-M) data transceivers provide point-to-point transmission of simplex or duplex EIA RS232/RS422/RS485 (2W/4W) data signals over one or two optical fibers. The transceivers are transparent to data encoding allowing for broad-range compatibility. Models within this series are available for use with multimode or single mode optical fiber. Each transceiver incorporates a bi-color (Red/Green) indicating LED for monitoring proper system operation. See Figure 8 on Page 6 for LED Indicator explanations. The (M)(S)(-M) has a built-in fiber link test feature that allows for the testing of the fiber. See Figure 13 on Page 8 for an explanation of the Loop Back Test Mode. The (M)(S) may be directly plugged into the ComNet Rack (Part C1) or they can operate as standalone modules. The (M)(S)-M has a small footprint and is designed for surface mounting. See Figures A and B on Page 9 for mounting instructions. See Figures 1 13 for complete installation details. INS REV PAGE 1

(M)(S)(-M) FIGURE 1 1 FIBER TRANSCEIVER MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE/RED FIGURE 2 1 FIBER TRANSCEIVER FRONT PANEL REAR PANEL NOTE: Remove Electrical Connector for Rack Mount Units INS REV PAGE 2

(M)(S)(-M) FIGURE 3 2 FIBER TRANSCEIVER MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE/RED FIGURE 4 2 FIBER TRANSCEIVER FRONT PANEL REAR PANEL NOTE: Remove Electrical Connector for Rack Mount Units INS REV PAGE 3

(M)(S)(-M) FIGURE 5 -M 1 FIBER TRANSCEIVER MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE/RED FIGURE 6 -M 1 FIBER TRANSCEIVER FRONT PANEL REAR PANEL NOTE: Remove Electrical Connector for Rack Mount Units INS REV PAGE 4

(M)(S)(-M) FIGURE 7 -M 2 FIBER TRANSCEIVER MULTIMODE OR SINGLE MODE OPTICAL FIBER BLACK BLACK WITH WHITE STRIPE/RED FIGURE 8 -M 2 FIBER TRANSCEIVER FRONT PANEL REAR PANEL NOTE: Remove Electrical Connector for Rack Mount Units INS REV PAGE 5

(M)(S)(-M) FIGURE 9 LED INDICATORS LINK DATA (TX/RX) LOOP BACK (Test Mode) POWER GREEN Unit In Sync Activity Fiber Link Connections are Correct Unit Powered Up RED Unit Not In Sync No Acvitiy Fiber Link Issue Exists (Head End) OFF No Optical Link Fiber Link Issue Exists (Far End); OR Test Mode is Off Unit Powered Down FIGURE 10 SWITCH POSITIONS Switch Located on front panel in full size modules and on back on small size modules. The first two switches set the data type, the third toggles Loop Back Test Mode. RS232 Data RS485 2-Wire, Sensornet Data RS422, Bi-Phase or Manchester Data RS485 4-Wire Data Loop Back Test * Loop Back Test Mode (see Page 8) INS REV PAGE 6

(M)(S)(-M) FIGURE 11 DATA CONNECTIONS Data In/Out + Data In/Out Data Out + Data Out RS232 Out RS232 In GND FIGURE 12 DATA SETTINGS Customer Equipment Customer Equipment RS232 Data Transmit Data Receive Signal Ground IN 2 OUT 3 GND 1 OUT 3 IN 2 GND 1 Data Receive Data Transmit Signal Ground RS422 Data Out (+) Data Out ( ) Data In (+) Data In ( ) Data In (+) Data In ( ) Data Out (+) Data Out ( ) Bi-phase or Manchester Data Out (+) Data Out ( ) Data In (+) Data In ( ) 2-Wire RS485 Data (A) Data (B) Data (A) Data (B) 4-Wire RS485 Data Out (A) Data Out (B) Data In (A) Data In (B) Data In (A) Data In (B) Data Out (A) Data Out (B) INS REV PAGE 7

(M)(S)(-M) FIGURE 13 LOOP BACK TEST MODE 1. On one end (Head End), put unit into Loop Back Mode by setting Switch 3 to OFF. Switch 1 and 2 can be in any position. Data will not pass during Loop Back Test, LEDs may flash if data is sent during Loop Back Test. 2. If the Far End unit is powered on and the fiber link connections are correct, the Far End unit Loop Back LED will light GREEN. 3. If the Head End unit has Switch 3 in the ON position, and if there is a fiber link issue, then the Far End unit Loop Back LED will remain OFF. This is an error condition. 4. If the Far End unit Loop Back LED is GREEN and the fiber link and optical connections back to the Head End unit are correct, then the Head End unit Loop Back LED will light GREEN. 5. If there is a fiber link issue from the Far End back to the Head End, or the Far End unit is not working, the Head End unit Loop Back LED will light RED when the Loop Back switch is set to OFF. This is an error condition. 6. When not in Loop Back Test Mode the Loop Back LED on both ends will be OFF. INS REV PAGE 8

MECHANICAL INSTALLATION INSTRUCTIONS INSTALLATION CONSIDERATIONS This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity. C1-US, C1-EU, C1-AU OR C1-CH CARD CAGE RACKS FIGURE A Dimensions are for a standard ComNet one slot module.156 [3.96 mm] CAUTION: Although the units are hot-swappable and may be installed without turning power off to the rack, ComNet recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack. 1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack s connector panel. Seating may require thumb pressure on the top and bottom of the card s front panel. CAUTION: Take care not to press on any of the LEDs..313 [7.95 mm] 2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack. WARNING: Unit is to be used with a Listed Class 2 or LPS power supply rated 9-12 VDC @ 1A. IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer. FIGURE B Dimensions are for a small size ComNet surface mount module B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. 3 CORPORATE DRIVE DANBURY, CT 06810 USA T: 203.796.5300 F: 203.796.5303 INFO@COMNET.NET 8 TURNBERRY PARK ROAD GILDERSOME MORLEY LEEDS, UK LS27 7LE T: +44 (0)113 307 6400 F: +44 (0)113 253 7462 INFO-EUROPE@COMNET.NET 2010 Communications Networks Corporation. All Rights Reserved. ComNet and the ComNet Logo are registered trademarks of Communication Networks, LLC. INS REV PAGE 9