SCXI HIGH-ACCURACY ISOTHERMAL TERMINAL BLOCK

Similar documents
SCXI CURRENT INPUT,HIGH-VOLTAGE TERMINAL BLOCK

SCXI High-Voltage Terminal Block

SCXI High-Voltage Terminal Block

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TBX CHANNEL ISOTHERMAL TERMINAL BLOCKINSTALLATION GUIDE

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TB-2705 PXI TERMINAL BLOCK FOR ESERIES

The following conventions apply to this document:

TBX-1326 HIGH-VOLTAGE TERMINAL BLOCK

SCC-DI01 Isolated Digital Input Module

NI sbrio-9632/9642 Verification Procedure

TBX-68S Isothermal Terminal Block

SCC-ACC01 Accelerometer Input Module

NI 6624 Calibration Procedure

SCC-CO20 Isolated Current Output Module

SCC-FV01 Frequency Input Module

BNC-2121 Connector Accessory for 660X Devices

FP-DO-400 and cfp-do-400

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9211E 4-Channel Thermocouple Input Module

FP-RTD-124 AND CFP-RTD-124. Features. FieldPoint Operating Instructions. Eight-Channel Four-Wire RTD and Resistance Input Modules

FP-SG-140 AND CFP-SG-140

VXI-TB CHANNEL ISOTHERMAL TERMINAL BLOCK

FP-RLY-420. Features. Installing the FP-RLY-420. FieldPoint Operating Instructions. Eight-Channel SPST Relay Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9207E 16-Channel, ±20 ma/±10 V, 24-Bit Analog Input Module

FP-RTD-122 AND CFP-RTD-122. Features. FieldPoint Operating Instructions. Eight-Channel Three-Wire RTD and Resistance Input Modules

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

BNC/TC-2095 RACK-MOUNT ADAPTER

NI Channel SPST Electromechanical Relay Module

The SCB-68 is a shielded board with 68 screw terminals for easy connection to National Instruments 68-pin products.

NI Channel, Universal Digital Input Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9213E 16-Channel Thermocouple Input Module

FP-RTD-122 and cfp-rtd-122

Eight-Channel Thermocouple Input Module

FP-CTR-500 and cfp-ctr-500

FP-DO-401 and cfp-do-401

FP-DO-403 and cfp-do-403

FP-CTR-502 and cfp-ctr-502

OPERATING INSTRUCTIONS NI Port DeviceNet Module

NI-IMAQ White Balancing Utility Help

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Channel, ±10 V, 16-Bit Simultaneous Analog Input Module. ni.com/manuals

NI Channel, TTL Digital Input/Output Module

GETTING STARTED GUIDE NI AI, ±60 V, 24 Bit, 1 ks/s/ch Simultaneous

NI PXI ½ Digit FlexDMM Calibration Procedure

NI Channel, ±10 V, 16-Bit Analog Voltage Output Module

OPERATING INSTRUCTIONS NI Channel, 24-Bit, Universal Analog Input Module

Getting Started with the LabVIEW DSP Module

SCXI HIGH-VOLTAGE ATTENUATOR TERMINAL BLOCK

GETTING STARTED GUIDE NI AI, ±10 V, 24 Bit, 50 ks/s/ch Simultaneous

SCXI TERMINAL BLOCK

GETTING STARTED GUIDE NI AI Differential/32 AI Single-Ended, ±200 mv to ±10 V, 16 Bit, 250 ks/s Aggregate, Fuel-Cell Measurements

NI PXIe Contents CALIBRATION PROCEDURE

INSTALLATION GUIDE BNC-2120 Connector Accessory for E/M/S Series Devices. Contents

AC/DC Current Probe TCP0150 Datasheet

SmartBlock I/O Module - HE579DAC107/HE579DAC207 8/4 Channel Current and Voltage Output 0-5V / 0-10V / 4-20mA / 0-20mA - CsCAN

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module

30 A AC/DC Current Probe TCP0030A Datasheet

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

Verifying Power Supply Sequencing with an 8-Channel Oscilloscope APPLICATION NOTE

SCXI 8-Channel Isolated Analog Input Modules

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

GETTING STARTED GUIDE NI AI, ±5 V, 24 Bit, 51.2 ks/s/ch Simultaneous, AC/DC Coupling, IEPE AC Coupling

Table 2. Differences Between the USB-6008 and USB Feature USB-6008 USB bits differential, 13 bits single-ended Maximum AI Sample Rate,

Using the Model 4225-RPM Remote Amplifier/ Switch to Automate Switching Between DC I-V, C-V, and Pulsed I-V Measurements APPLICATION NOTE

P7500 Series Probes Tip Selection, Rework and Soldering Guide

Contents NUDRIVE ACCESSORY USER GUIDE

12.5 Gb/s Driver Amplifier PSPL5865 Datasheet

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

SCXI. SCXI-1126 User Manual. SCXI-1126 User Manual. Eight-Channel Isolated Frequency Input Module for Signal Conditioning

DAQ. SCC Series User Manual. SCC Series User Manual. December 1999 Edition Part Number D-01

Soldering a P7500 to a Nexus DDR Component Interposer

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

NI Channel, 24-Bit, Universal Analog Input Module

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

SCXI. SCXI-1120/D User Manual

1.5 GHz Active Probe TAP1500 Datasheet

10 GHz Linear Amplifier PSPL5866 Datasheet

High-voltage Differential Probes

Agilent 4294A Precision Impedance Analyzer, 40 Hz to 110 MHz. Configuration Guide

Data Sheet. Agilent M9185A PXI Isolated D/A Converter. DISCOVER the Alternatives... Agilent MODULAR Products. 8/16-Channel 16-bit, ±16 V

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

DATASHEET NI Channel, 250 V Sinking Digital Input Module

Simplifying FET Testing with 2600B System SourceMeter SMU Instruments APPLICATION NOTE

PRODUCT DATA. Sound Intensity Calibrator Type 4297

NI Contents CALIBRATION PROCEDURE

SPAC265-8W. AC-DC power supply module. Features. Description. Applications

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

S540 Power Semiconductor Test System Datasheet

NI USB-9211/9211A. Introduction USER GUIDE AND SPECIFICATIONS. 4-Channel, 24-Bit Thermocouple Input Devices

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

NI 4070/4072 6½-Digit FlexDMM

Through-beam ring sensors

TETRIS User's Guide. High Impedance Active Probe DO177-1

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Signal Conditioning. SC-2311 User Manual. Connectivity for 5B and SSR Modules. SC-2311 User Manual. February 2001 Edition Part Number A-01

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

LE160 LE320 Linear Equalizer Datasheet Tektronix Linear Equalizer

Agilent N4000A, N4001A, N4002A SNS Series Noise Sources 10 MHz to 26.5 GHz

TriMode Probe Family P7700 Series TriMode Probes

Frame through-beam sensors

Transcription:

INSTALLATION GUIDE SCXI -38 HIGH-ACCURACY ISOTHERMAL TERMINAL BLOCK Introduction This guide describes how to install and use the SCXI-38 high-accuracy isothermal terminal block with the SCXI-0, SCXI-0D, SCXI-, SCXI-5, and SCXI-6 modules. The SCXI-38 high-accuracy isothermal terminal block is a shielded terminal block with screw terminals to connect to the SCXI module input connector. The SCXI-38 has a high-precision thermistor for precise cold-junction compensation and an aluminum isothermal plate to minimize the temperature gradients across the screw terminals when you make measurements with thermocouples. The terminal block has 8 screw terminals for easy connection. One pair of screw terminals connects to the SCXI chassis ground. With the SCXI-0/D, SCXI-5 or SCXI-6, the remaining eight pairs of screw terminals are for signal connection to the eight module inputs. With the SCXI-, four pairs of screw terminals are for the four module inputs and four pairs are for the module excitation channels. What You Need to Get Started To set up and use your SCXI-38 terminal block, you need the following items: SCXI-38 terminal block SCXI-38 High-Accuracy Isothermal Terminal Block Installation Guide SCXI chassis CVI, LabVIEW, National Instruments, ni.com, NI-DAQ, and SCXI are trademarks of National Instruments Corporation. Product and company names are trademarks or trade names of their respective companies. 3877C-0 Copyright 993, 00 National Instruments Corp. All rights reserved. January 00

One of the following modules: SCXI-0 SCXI-0D SCXI- SCXI-5 SCXI-6 Number and Phillips-head screwdrivers /8 in. flathead screwdriver Long-nose pliers Wire cutters Wire insulation stripper Conventions The following conventions are used in this guide:» The» symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs you to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a note, which alerts you to important information. This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. italic monospace Italic text denotes variables, emphasis, a cross reference, or an introduction to a key concept. This font also denotes text that is a placeholder for a word or value that you must supply. Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames and extensions, and code excerpts. SCXI-38 Installation Guide ni.com

Safety Information Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. Keep away from live circuits. Do not remove equipment covers or shields unless you are trained to do so. If signal wires are connected to the device, hazardous voltages may exist evenwhentheequipmentisturned off. Toavoid ashock hazard, donot perform procedures involving cover or shield removal unless you are qualified to do so and disconnect all field power prior to removing covers or shields. Equipment described in this document must be used in an Installation Category II environment per IEC 664. This category requires local level supply mains-connected installation. Do not operate damaged equipment. The safety-protection features built into this device can become impaired if the device becomes damaged in any way. If the device is damaged, turn the device off and do not use until service-trained personnel can check its safety. If necessary, return the device to National Instruments for service and repair to ensure that its safety is not compromised. Do not operate this equipment in a manner that contradicts the information specified in this document. Misuse of this equipment could result in a shock hazard. Terminals are for use only with equipment that has no accessible live parts. Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, do not install unauthorized parts or modify the device. Return the device to National Instruments for service and repair to ensure that its safety features are not compromised. When using the device with high common-mode voltages, you must insulate your signal wires for the highest input voltage. National Instruments is not liable for any damages or injuries resulting from inadequate signal wire insulation. Use only 6-4 AWG wire with a voltage rating of 300 V and 60 C for measuring up to 300 V. When connecting or disconnecting signal lines to the SCXI terminal block screw terminals, make sure the lines are powered off. Potential differences between the lines and the SCXI ground create a shock hazard while you connect the lines. Connections, including power signals to ground and vice versa, that exceed any of the maximum signal ratings on the SCXI device can create a shock or fire hazard or can damage any or all of the boards connected to the SCXI chassis, the host computer, and the SCXI device. National Instrumentsis not liable for any damages or injuries resulting from incorrect signal connections. Category II refers to local-level power distribution such as that provided by a standard wall outlet. National Instruments Corporation 3 SCXI-38 Installation Guide

If high voltages ( 30 V rms and 4.4 V peak or 60 VDC) are present, you must connect a safety earth ground wire to the terminal block safety-ground lug, showninfigure.this complies with safety agency requirements and protects against electric shock when the terminal block is not connected to the chassis. To connect the safety earth ground to the safety ground lug, run an earth ground wire in the cable from the signal source to the terminal block. National Instruments is not liable for any damages or injuries resulting from inadequate safety earth ground connections. Do not loosen or re-orient the safety ground lug hardware when connecting the safety ground wire; to do so reduces the safety isolation between the high voltage and safety ground. Clean devices and terminal blocks by brushing off light dust with a soft, nonmetallic brush. Remove other contaminants with deionized water and a stiff nonmetallic brush. The unit must be completely dry and free from contaminants before returning to service. Connecting the Signals Note Refer to the Safety Information section before removing equipment covers or connecting or disconnecting any signal wires. When connecting your signals to the SCXI-38, follow the labeling on the SCXI-38 for the appropriate module, as indicated in Figure. For the SCXI-0D, SCXI-5, and SCXI-6, follow the labeling for the SCXI-. To connect the signal to the terminal block, perform the following steps, referringtofiguresandasnecessary:. Unscrew the top cover screws and remove the cover.. Loosen the strain-relief screws and remove the strain-relief bar. 3. Run the signal wires through the strain-relief opening. You can add insulation or padding, if necessary. 4. Prepare your signal wire by stripping the insulation no more than mm. 5. Connect the wires to the screw terminals by wrapping the wires around the screw. No bare wire should extend past the screw head. Exposed wire reduces the safety isolation between the high voltage and low voltages. 6. Tighten the screws to a torque of 5 7 in.-lb. 7. Connect safety earth ground to the safety-ground lug. Refer to the Safety Information section for connection information. SCXI-38 Installation Guide 4 ni.com

8. Reinstall the strain-relief bar and tighten the strain-relief screws. 9. Reinstall the top cover and tighten the top cover screws. 6 7 3 4 5 Strain-Relief Bar Strain-Relief Screws 3 Safety-Ground Lug 4 Mating Connector 5 Thumbscrew 6 Top Cover Screws 7 Top Cover Figure. SCXI-38 Parts Locator Diagram SCXI-38 HIGH ACCURACY ISOTHERMAL TERMINAL BLOCK DTEMP MTEMP + + + + + + + + CH0 CH CH CH3 SCXI-0 CH4 CH5 CH6 CH7 CH0 EX0 CH EX SCXI- CH EX CH3 EX3 WARNING: IF HIGH VOLTAGE IS PRESENT, AN WIRE MUST BE CONNECTED TO EXTERNAL SAFETY EARTH GROUND STRAIN RELIEF EARTH TERMINAL! 3 Screw Terminals Channel Labeling for the SCXI-0/D, SCXI-5, and SCXI-6 3 Channel Labeling for the SCXI- Figure. SCXI-38 Signal Connections National Instruments Corporation 5 SCXI-38 Installation Guide

Installing the Terminal Block To connect the terminal block to the SCXI module front connector, perform the following steps:. Connect the module front connector to its mating connector on the terminal block.. Tighten the top and bottom thumbscrews on the back of the terminal block to hold it securely in place. Note For accurate cold-junction compensation, place the SCXI chassis away from an extreme temperature differential. Specifications All specifications are typical at 5 C unless otherwise specified. Electrical Compatible modules SCXI-0/D...8 input channels SCXI-...4 input channels and 4 excitation output channels SCXI-5...8 input channels SCXI-6...8 input channels Cold-junction temperature-sensor circuitry Sensor type...thermistor Output range...9 to 0.65 Accuracy...±0.5 from 5 to 35 C ±0.9 from0to5 C and35to50 C Repeatability...±0. from 5 to 35 C Output...9 to 0.65 V from 0 to 50 C Coupling...DC Current-receiver resistors...resistors not included resistor sockets not provided Includes the accuracy of the temperature-sensor circuitry itself and the temperature difference between the thermistor and any screw terminal. The temperature-sensor circuitry accuracy includes tolerances in all component values, effects caused by component-value temperature drift, voltage-divider loading, and thermistor self-heating. In instrumentation terminology, DC coupling means that both DC and AC signals are passed. SCXI-38 Installation Guide 6 ni.com

Maximum working voltage (signal and common-mode) Channel to ground... Each channel must remain within 300 V rms or ±300 VDC of ground Channel to channel... Each channel must remain within 300 V rms or ±300 VDC of the voltage applied to any other channel Field-wiring connectors 6 screw terminals (8 pins) Terminal spacing....0 cm (0.4 in.) center-to-center Dimensions of front entrance.... by 7.3 cm (0.47by.87in.) Solder pads for additional components... None Safety earth-ground lugs... Strain relief... Strain-relief ban at terminal-block entrance Mechanical Dimensions... 7.8 by 7.94 by 3.0 cm (7.0 by 3.5 by. in.) Weight... 00 gm (7 oz.) Environment Operating temperature... 0 to 50 C Storage temperature... 0 to 70 C Relative humidity... 5 to 90% noncondensing Altitude (max.)...,000 m Safety Designed in accordance with IEC 600-, UL 3-, and CAN/CSA C. No. 00. for electrical measuring and test equipment. Installation Category II Pollution Degree National Instruments Corporation 7 SCXI-38 Installation Guide

Temperature Sensor Output and Accuracy The SCXI-38 temperature sensor outputs.9 to 0.65 V from 0 to 50 C National Instruments software can convert a thermistor voltage to the thermistor temperature for the circuit diagram shown in Figure 3. In LabVIEW, you can use the Convert Thermistor Reading VI in the Data Acquisition»Signal Conditioning palette. If you are using LabWindows/CVI or NI-DAQ, use the Thermistor_Convert function. The VI takes the output voltage of the temperature sensor, the reference voltage, and the precision resistance and returns the thermistor temperature. Alternatively, you can use the following formulas: T( C) = T K 73.5 where T K is the temperature in kelvin a =.9536 0 3 b =.34359 0 4 c =.08703 0 7 T K = ------------------------------------------------------------- [ a + b( lnr T ) + c( lnr T ) 3 ] R T = resistance of the thermistor in ohms V TEMPOUT R T = 5000, -------------------------------------.5 V TEMPOUT V TEMPOUT = output voltage of the temperature sensor T ( F) [ T ( C) ]9 = ---------------------- + 3 5 where T( F) and T( C) are the temperature readings in degrees Fahrenheit and degrees Celsius, respectively. Note Use an average of a large number of samples to obtain the most accurate reading. Electrically noisy environments require more samples for greater accuracy. SCXI-38 Installation Guide 8 ni.com

Reading the Temperature Sensor in LabVIEW Note This section is not applicable to the SCXI-6. In LabVIEW, the channel string used to read V TEMPOUT depends on which module is connected to the SCXI-38. For more information about channel-string arrays and the SCXI channel-addressing syntax, see the LabVIEW Measurements Manual. With the SCXI-0, SCXI-0D, or SCXI-, use the address string: obx! scy! mdz! mtemp You cannot put this channel-address string in the same channel-string array as other channels on the module that you are addressing. With the SCXI-5, use the address string: obx! scy! mdz! cjtemp You can put this channel-address string in the same channel-string array as other channels on the same SCXI-5 module and can call it multiple times within the same channel-string array. Temperature Sensor Circuit Diagram You do not need to read this section to operate the SCXI-38. The circuit diagram in Figure 3 is optional information you can use if you want more details about the SCXI-38 temperature sensor. +5 V.5 V LM 4040.5 V 0.% V TEMPOUT Figure 3. Temperature Sensor Circuit Diagram National Instruments Corporation 9 SCXI-38 Installation Guide

Technical Support Resources NI Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section of ni.com Worldwide Support National Instruments has offices located around the world to help address your support needs. You can access our branch office Web sites from the Worldwide Offices section of ni.com. Branch office Web sites provide up-to-date contact information, support phone numbers, e-mail addresses, and current events. If you have searched the technical support resources on our Web site and still cannot find the answers you need, contact your local office or National Instruments corporate. For telephone support in the United States, dial 5 795 848. For telephone support outside the United States, contact your local branch office: Australia 03 9879 566, Austria 066 45 79 90 0, Belgium 0 757 00 0, Brazil 0 84 50, Canada (Calgary) 403 74 939, Canada (Ottawa) 63 33 5949, Canada (Québec) 54 694 85, China (Shanghai) 0 6555 7838, China (ShenZhen) 0755 3904939, Denmark 45 76 6 00, Finland 09 75 75, France 0 48 4 4 4, Germany 089 74 3 30, Greece 30 4 96 47, Hong Kong 645 386, India 980575406, Israel 03 6009, Italy 0 4309, Japan 03 547 970, Korea 0 596 7456, Mexico 5 80 765, Netherlands 0348 433466, New Zealand 09 94 0488, Norway 3 7 73 00, Poland 0 58 94 06, Portugal 35 76 90, Singapore 65886, Spain 9 640 0085, Sweden 08 587 895 00, Switzerland 056 00 5 5, Taiwan 0 58 77, United Kingdom 0635 53545 SCXI-38 Installation Guide 0 ni.com