Improved Structural Monitoring with Acoustic Emission Pattern Recognition

Similar documents
Chapter 4 Results. 4.1 Pattern recognition algorithm performance

Paper Title: FIELD MONITORING OF FATIGUE CRACK ON HIGHWAY STEEL I- GIRDER BRIDGE

A SHEAR WAVE TRANSDUCER ARRAY FOR REAL-TIME IMAGING. R.L. Baer and G.S. Kino. Edward L. Ginzton Laboratory Stanford University Stanford, CA 94305

MULTI-PARAMETER ANALYSIS IN EDDY CURRENT INSPECTION OF

DETECTION AND SIZING OF SHORT FATIGUE CRACKS EMANATING FROM RIVET HOLES O. Kwon 1 and J.C. Kim 1 1 Inha University, Inchon, Korea

Nondestructive Evaluation Tools to Improve the Inspection, Fabrication and Repair of Bridges

ISO INTERNATIONAL STANDARD. Non-destructive testing Acoustic emission inspection Secondary calibration of acoustic emission sensors

NOVEL ACOUSTIC EMISSION SOURCE LOCATION

WIRELESS SENSOR NETWORKS TO MONITOR CRACK GROWTH ON BRIDGES

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique

The Application of TOFD Technique on the Large Pressure Vessel

Update on Bridge Deck Fastener Performance on the FAST Steel Bridge. By Duane Otter and Brian Doe ABSTRACT

NEURAL NETWORK FATIGUE LIFE PREDICTION IN NOTCHED BRIDGE STEEL I-BEAMS FROM ACOUSTIC EMISSION AMPLITUDE DATA

Instantaneous Baseline Damage Detection using a Low Power Guided Waves System

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

TESTING A BINARY CRACK SENSOR USING A LABORATORY MODEL OF CRACKS IN STEEL GIRDERS

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

Ultrasonic Phased Array Crack Detection Update

DEEP FLAW DETECTION WITH GIANT MAGNETORESISTIVE (GMR) BASED SELF-NULLING PROBE

Two basic types of single

Acoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping

Recommendation of RILEM TC 212-ACD: acoustic emission and related NDE techniques for crack detection and damage evaluation in concrete*

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS

EDDY CURRENT INSPECTION FOR DEEP CRACK DETECTION AROUND FASTENER HOLES IN AIRPLANE MULTI-LAYERED STRUCTURES

ULTRASONIC SIGNAL CHARACTERIZATIONS OF FLAT-BOTTOM HOLES IN

Eddy Current Signal Analysis Techniques for Assessing Degradation of Support Plate Structures in Nuclear Steam Generators

JOHANN CATTY CETIM, 52 Avenue Félix Louat, Senlis Cedex, France. What is the effect of operating conditions on the result of the testing?

Pave-IR Scan TM Primer

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

Long-Range Inspection of Suspender Ropes in Suspension Bridges Using the Magnetstrictive Sensor Technology Dyab A. Khazem, Hegeon Kwun, Sang-Young

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

Noise Mitigation Study Pilot Program Summary Report Contract No

ABCDE. TechBrief. Best Practices for Dowel Placement Tolerances

FATIGUE CRACK CHARACTERIZATION IN CONDUCTING SHEETS BY NON

Enhanced Resonant Inspection Using Component Weight Compensation. Richard W. Bono and Gail R. Stultz The Modal Shop, Inc. Cincinnati, OH 45241

SKT-SP Tangent Terminal

Welding Qualification/Certification

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

Developments in Ultrasonic Guided Wave Inspection

IMAGING OF DEFECTS IN CONCRETE COMPONENTS WITH NON-CONTACT ULTRASONIC TESTING W. Hillger, DLR and Ing. Büro Dr. Hillger, Braunschweig, Germany

ELIMINATION OF EXTRANEOUS NOISE SOURCES FROM ACOUSTIC EMISSION BASED TERMITE DETECTION INSTRUMENT BY USE OF MODAL RATIOS H.L. DUNEGAN AUGUST 15, 2001

Load Indicating Washers

Acoustic Transducer*

AUTOMATED EDDY CURRENT DETECTION OF FLAWS IN SHOT-PEENED

1. Report No. FHWA/TX-05/ Title and Subtitle PILOT IMPLEMENTATION OF CONCRETE PAVEMENT THICKNESS GPR

BALANCE FIELD ELECTROMAGNETIC TECHNIQUE INSPECTION REPORT OF THE 8_INCH_1260_FITTING (HA-2/1200 BLOCK) TESTEX, INC. TESTED: JANUARY 9, 2019

Imaging using Ultrasound - I

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

712 - STRUCTURAL STEEL CONSTRUCTION SECTION 712 STRUCTURAL STEEL CONSTRUCTION

Weldment Visual Inspection Requirements

MILITARY SPECIFICATION LIGHTING, INSTRUMENT, INTEGRAL, WHITE GENERAL SPECIFICATION FOR

VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering

AFRL-RX-WP-TP

DACON INSPECTION SERVICES. Phased Array Ultrasonic Testing

Standard Practice for Ultrasonic Examination of Turbine and Generator Steel Rotor Forgings 1

G. A. Alers and D. T. MacLauchlan

Ultrasonic Infrared Thermal Wave Technology and Its Applications in. Nondestructive Evaluation

CLAMP-ON ULTRASONIC FLOW METER APPLICATION AND PERFORMANCE WILLIAM E. FRASIER RETIRED CASEY HODGES CEESI MEASUREMENT SOLUTIONS

FAQver. CARTER PRODUCTS. Laser Computer Pattern Projection Systems FREQUENTLY ASKEDQUESTIONS

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

CRACK DETECTION AND DEFECT CLASSIFICATION USING THE LLT - TECHNIQUE. Wolfgang Gebhardt and Friedhelm Walte

AUTOMATED INTERPRETATION OF EXTERNAL TANK WELD RADIOGRAPHS

Make a Safe. Description. Lesson Objectives. Assumptions. Terminology

TxDOT Project : Evaluation of Pavement Rutting and Distress Measurements

Acoustic Filter Copyright Ultrasonic Noise Acoustic Filters

Table 1 The wheel-set security system of China high-speed railway

Protocols and Criteria for Acoustic Emission Monitoring of Fracture-Critical Steel Bridges

FLEXURAL TORSIONAL GUIDED WAVE PIPE INSPECTION

FIRST MEASUREMENTS FROM A NEW BROADBAND VIBROTHERMOGRAPHY MEASUREMENT SYSTEM

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

EE 422G - Signals and Systems Laboratory

Nondestructive Testing (CALIBRATION)

Novel Imaging Techniques for Defects Characterisation in Phased Array Inspection

Rotor Life Assessment

Structural Criteria for Residential Flush-Mounted Solar Arrays

A Principal Component Analysis of Acoustic Emission Signals from a Landing Gear Component

REPORT ITU-R BT Radiation pattern characteristics of UHF * television receiving antennas

Advances in Carbon Steel Weld Inspection using Tangential Eddy Current Array

Guided Wave Travel Time Tomography for Bends

The Metrology Behind Wideband/RF Improvements to the Fluke Calibration 5790B AC Measurement Standard

Connection and Tension Member Design

CND INCORPORATED Massillon, OH

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

FINAL REPORT. On Project Supplemental Guidance on the Application of FHWA s Traffic Noise Model (TNM)

Rockwell International Science Center

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

Southwest Research Institute 6220 Culebra Road San Antonio, TX 78284

CENTER FOR INFRASTRUCTURE ENGINEERING STUDIES

X. SPEECH ANALYSIS. Prof. M. Halle G. W. Hughes H. J. Jacobsen A. I. Engel F. Poza A. VOWEL IDENTIFIER

JVI Vector Connector

Dowel Bar Alignment and Location for Placement by Mechanical Dowel Bar Insertion

A SIMPLE METHOD TO COMPARE THE SENSITIVITY OF DIFFERENT AE SENSORS FOR TANK FLOOR TESTING

Structural Criteria for Residential Rooftop Solar Energy Installations

NUMERICAL MODELING OF AIR-COUPLED ULTRASOUND WITH EFIT. D. E. Chimenti Center of Nondestructive Evaluation Iowa State University Ames, Iowa, USA

HANDBOOK OF NONDESTRUCTIVE EVALUATION (NDE) CAP ABILITY AND RELIABILITY*

Visualization of internal damage in RC slab with single side access attenuation tomography

Transcription:

Transportation Kentucky Transportation Center Research Report University of Kentucky Year 1983 Improved Structural Monitoring with Acoustic Emission Pattern Recognition David W. Prine Theodore Hopwood II GARD, Inc. University of Kentucky, ted.hopwood@uky.edu This paper is posted at UKnowledge. https://uknowledge.uky.edu/ktc researchreports/976

Research Report UKTRP-83-10 IMPROVED STRUCTURAL MONITORING WITH ACOUSTIC EMISSION PATTERN RECOGNITION by David W. Prine CARD, Inc. Niles, Illinois and TI1eodore Hopwood II Kentucky Transportation Research Program Lexington, Kentucky 14th Annual Symposium on Nondestructive Evaluation April 19-22, 1983 San Antonio, Texas April 1983

IMPROVED STRUCTURAL MON.ITORING WITH ACOUSTIC EMISSION PATTERN RECOGNITION David W. Prine GARD, INC. Niles, Illinois 60648 Theodore Hopwood II, P. E. Kentucky Transportation Research Program Lexington, Kentucky 40506 Abstract A unique acoustic emission monitoring system originally developed for inprocess weld monitoring has been used to monitor fatigue crack growth in a highway bridge during normal traffic loading. The system was able to clearly and reliably detect the presence of fatigue cracks that were adjacent to a row of bolts. The results of the brief experiment show that the signal processing used in this AE system may allow drastic improvements in the ability of acoustic emission to reliably detect propagating bridge flaws under adverse conditions. ----'!1Tele is a growing r1eed to Insure the safety of the motoring public by performing periodic nondestructive evaluation (NDE) of in-service bridges. Older bridges are being subjected to loadings in excess of their original design capacity. Owing to the combined effects of age, atmosphere, and loading, these structures are prone to sub-critical, growing cracks. Newer bridges have employed ambitious designs, which often incorporate "fracture-critical" structural members. These bridges also rely on highstrength steels and welding fabrication processes to provide economical structures. These bridges have demonstrated a susceptibility to crack problems caused by fabrication-related defects. Unfortunately,the quality-assurance/ quality-control measures used in recently constructed bridges have not precluded fracture problems. A promising NDE technique entails monitoring of acoustic emissions (AE) from bridges and correlation of these emissions with the integrity of the structural members. However, the user of the AE methodology faces many problems due to the environment, complexity, and size of bridges. The uncertainty of internal defect excitation places even further limitations on the AE technique. However, the main 1 imitation with present AE technology is the ability to relate AE signals to specific source events. Currently available AE instrumentation can perform standard signal analysis, with well defined firmware using the signal in digital form. However, th1s equ1pment and methodol ogy does not exploit currently developed signalprocessing techniques to characterize defects and their locations. Recent laboratory signalcharacterization tests have yielded promising results, but it is not known whether these techniques are viable in field applications. Also, little work has been done to optimize equipment, test methods and data analysis from bridge AE sources. The problem of positively identifying, locating, and assessing flaws is presently an active area of research in AE technology. 2. BACKGROUND GARD, INC. has been actively pursuing the application of acoustic emission monitoring to the in-process NOT of welds for over eleven years. These efforts have culminated in the development of a microprocessor-based acoustic emission monitoring system that can detect, locate, and characterize flaws in welds during the welding process. The system has been evaluated and optimized for a wide range of commonly utilized welding processes and materials. An extensive evaluation program sponsored bj FHWA (Contract No. DTFH61-80-C-00083) has just been completed in which the Acoustic Emission Weld Monitor (AEWM) was successfully tested on typical highway bridge materials and weld methods. The detailed results of this program are presented in Report No. FHWA/RD-83-006 to be published shortly. In over 350 feet of laboratory controlled welding in both A-36 and A-514 steel, using

- - - - - both GMAW and SAW welding methods, the GARD monitor detected 97% of the flaws (missing would be very difficult to monitor because of large amounts of fretting noise resulting from only one porosity). Furthermore it correctly the bolted connections. This assumption was characterized 92% of the cracks. No un-confirmed borne out in the tests in that typically over AE indications were produced, however 14 flaws 1000 AE events occurred per hour during the which were predominantly cracks and lack of tests. The activity was in all cases associated fusion were either un-detected or marginally detected by radiography and ultrasonics but with the passage of traffic over the portion of the bridge being tested. were easily detected by the AEWM and confirmed by metallography. The key to this success is Standard resonant AE sensors were used for the AE signal processing methods developed by these tests. The sensors had internal perma- GARD. The welding environment is a very diffi- nent magnets for attachment purposes. Silicone cult area for application of acoustic emission greas e was used as a couplant. The sensors monitoring due to the extremely high acoustic were mounted 64'' apart along the edge of the nois e levels that exist. These high nois e angle splice plate. They were acoustically levels preclude the application of conventional coupled to the cross beam, and the upper flange acoustic emission monitoring techniques because (which was the site of the crack) was located of the high incidence of AE signals that result about 16'' down from the top AE sensor (channel from benign or non-flaw related sources. The 1). The AEWM was used in a two channel linear GARD signal processing technique uses an empiri- source location mode. A third sensor was cally developed pattern recognition method that attached as near as practical to the crack site. keys on the AE signal characteris tics res ulting This 3rd sensor was driven by a high power from flaw growth and allows the vast amount of pulser and was periodically pulsed to produce non-flaw ------------ related -------AE to be rejected. a simulated AE burst to allow checkout of the ------------ ---- -------------- -------- ------ A r-systerris m:-e- : ---A-cypi-car s-e-rrs or- s-et - The problem of detection of flaw related AE up is shown in the lower portion of Figure 5. tn at 1 s 1 mbedd e d 1 n a h i g II no i s e ba c kgrrrorru rmrct:r----- Ean<cc11,-r-rt"Pecr:cFei-i <rv hirn:rgr--ss-e-en-11 S'>10'l1t--hlrraa-d aa--tutrtiri-ttoty---n, g a 1h' r,-:r-tcp<rr -.. e is not unique to the in-process weld monitor- amplifier attached to it. This pre-amp matches ing application. Rather, it is typical of a the high impedance of the sensor to the 50n wide range of potential AE applications, one cable so that cable length is not a factor. of which is the in-service monitoring of Signal cables were fed acros s the pier and up bridges for flaw growth. The belief that the to the bridge deck where the AE equipment was AEWM might prove effective for this application mounted in a self-contained motor home that led to the work des cribed in this paper. acted as a mobile laboratory. Figure 2 shows the mobile lab in place on the bridge. 3. EXPERIMENTAL DESCRIPTION The AEWf1 performs the required pattern recognition The tests described herein were conducted on for flaw detection in real-time. The the 1-24 Twin-Arch Bridges over the Tennessee process consists of subjecting each AE event to R1ver, near Paducah, Kentucky.. The tests were a series of tests performed in sequence. The performed by GARD with the assistance of both current flaw detection model is a three step Kentucky Trans portation Research Program (KTRP) proces s. A flow chart of the process is shown and Kentucky Department of Highways (KYDOH) in Figure 3. After computing the ringdown personnel. count (ROC) for each event the firs t test is KYDOH had previously determined that the bridge applied. If the ROC lies within pre-set limits the event is passed on to the next test wh1ch had suffered out-of-plane bending cracks near is rate. This test requires that there be some the connections in the deck cros s beams in the number N of events (that have passed the ROC vicinity of the upper flanges. This type of test) within some pre-set!it or time interval. cracking is caused by design and construction The final test is a test to see if all of the problems and is somewhat generic for this events that passed the previous two tests bridge type. The cracking is fatigue-related originate from the same location, or at leas t and is not due to any fabrication defects in within some pre-set locational tolerance. The the steel weldments. combination of the rate and location tests provides very high dis crimination agains t In an inspection performed just prior to the interfering background acoustic signals, the AE monitoring tests KTRP confirmed several assumption being that a growing flaw will produce crack sites in the cross beams over the piers. higher rates of AE burst emission than The cracks were located at the termini of the other proces ses and that the flaw, being a upper flanges, us ually at the toes of the web localized phenomena will produce the high rate to-flange fillet weld. A typical site is shown in Figure 1. Dye penetrant and in some cases surface rust made the cracks easily visible. The flaw sites chosen for tes ting purposes were all located near bolted angle splice plates that connected the cros s beams to the tie-girders. It was felt that these locations --- from a specific well defined location. Our use of source location as a flaw detection criteria differs radically from the traditional use of source locat1on information. In conventional AE monitoring equipment, source location may be used to lock out given areas or regions of the structur e under test, in other words, the sys tern. rnay be made to 1 is ten on 1 y to a -

specific location. This approach requires show some clustering of activity from the prior knowledge of the probable location of a flaw, and its degree of success depends on the flaws being locationally isolatable from crack site along with some scattered ground activity. backpotentially interfering sources (a condition The next site tested was located on the west that is seldom met in typical bridge structures). bound span (Location 3). This was the most GARD's approach to the use of source location severe f1 aw tested. T11e re was a 2" 1 ong does not limit the monitor to a specific through crack at the toe of the web to flange location. Any source location lying between fillet weld in addition to a second crack the transducers is monitored. When a group emanating from under the angle splice plate of AE events has satisfied the first two directly above the same region. This flaw criteria (i.e., ringdown count and event rate) a test is made to see that all of the group of was positioned under the passing lane of the bridge and so it received the maximum possible events lie within preset locational limits of loading during the test. Figure 5 shows the each other. For example, if a 1 inch tolerance results of two separate tests performed on is used, then the events that satisfied the this site over two successive days. Each test first two tests must have the same order of was approximately 2 hours long. The model receipt at transducers 1 and 2 and their used for fla 1 detection had limits as follows: locational clock indications must not differ by more than 16 counts ( 16 seconds). If ROC - 16 to 4000 this criteria is met, then a flaw indication Rate - 4 events in one second is shown at the appropriate location. Later Location - 1" tolerance in this paper, the importance of a ll three tests wi 11 be shown. -- --- I - n - addittan -to-the-detertiun-- of -- the - fla:vrre-o In the upper right corner of the printout, the total number of received AE events is shown. ------------- ---ro-r- rn es et es ts- w e- -see-tnaf-fhe - m s were ------ lated AE, the AEWM applies an adaptive fre 2130 for the first 2 hour monitoring period ---<qtwrley a-oo-l-y5-i-s-medel ta tire flaw-related and 818 for tile secor1d. Tlrese differences events and provides a 2 category classification reflect the difference in the amount of traffic of the source, crack or non-crack. for the two monitoring periods. The AEWM Display prints sets of rectangular brackets to For these tests a floppy disc system was used represent the two sensor positions with channel in addition to the AEWM to allow post test 1 at the left and channel 2 at the right. In analysis of data. In this mode of operation, this display,.flaw indications will be shown at the limits for the flaw detection criteria any location when the detection criteria are can be varied and raw AE data c n be played met. The edge of the angle splice runs along back through the modified model thus allowing the line between the two sensors. The character, optimal monitoring parameters to be obtained. C, 0, in the upper display indicates that A photograph of the AEWM in operation is shown in Figure 4. 4. RESULTS A total of five sites were monitored over a three day period. Only one of these actually produced AE 1nd1cat1ons. lhese 1nd1cat1ons repeated on two consecutive days and were properly located in the known crack region. The first two sites tested were above the West Pier on the eastbound span. The first area (Location 1) had a 1 " 1 ong crack at the flange terminus. Considerable AE activity resulted during the two hour test. The activity occurred in conjunction with traffic and highest amounts of activity correlated with large heavy vehicles. None of the resulting activity produced any AE indications (valid AE). This test constituted mon.itoring a small crack under light loading conditions. After two hours, the sensors were moved to the passing lane side of the bridge in an attempt to get higher loading on a flaw (Location 2). This site had two 1'' cracks visible in a location similar to the first. No valid indications resulted in a two hour test at this site, however, a relaxing of the flaw detection requirements (lmvet ing rate from 4 to 2Hz) did at this location the flaw detection criterion was satisfied. Furthermore, the characterization model decided that the AE was crack re- 1 a ted. The "0" fa 11 owing the comma is the truncated average of the ringdown counts for the four or more events that satisfied the detection model. In this case 0 signifies that the average ringdown count was between 0 and 99. Add1t1onal groups of events that satisfied the model are presented below the "C, 0". Time of occurrance proceeds in a downward direction. The "S,:" indication is produced by our calibration pulser which was located adjacent to the bottom edge of the flange. The cracks extended around the end of the flange and above the end of the flange off toward the angle splice plate. The ''S, 3'' indication occurs at about the end of the flange (S signifies noncrack related). One additional S, 2 indication occurs near the midpoint of the monitoring region. Confirmation of a flaw in this region was not possible at the time the test was run. The lower display was the result of another 2 hour monitoring period the following day. There was considerably less traffic during this period which is reflected in the lowered AE event count (818). One indication (S,3) occurs from the lower edge region of the flange.

The photograph below the printouts sho 1s the sensors in place. The actual orientation was vertical, however we rotated the picture 90 to place the significant features in approximately the same orientation as the printouts. To summarize results for this site, all of the indications were grouped around the region of the known crack with the exception of one which occurred at just above the midpoint of the sensor array. 5. SUf1MARY The AEWM was used to monitor several sites on a bridge where known fatigue cracks exist. The two channel linear location system suppressed the acoustic noise from fastener fretting and reliably and clearly detected crack-related activity even though the cracks were either immediately adjacent to or coincident with the bolt holes. Besides proving that flaw growth related To further test the reliability of the AEWM activity can be detected from noisy structural to discriminate between the fastener noise and details, this work showed that very smal I the crack emissions we positioned the sensors amounts of fatigue crack growth can be detected on an adjacent plate where the same pattern of when a bridge is subject to routine loadings. fasteners existed, but no flaws were visible The volume of traffic on this bridge was not (Location 3A). A 2\2 hour monitoring period significant compared to bridges in more urban from this site produced 700 AE events. but no locations. Nor was the magnitude of the bridge flaw indications. The final site tested loadings unusual. While the valid AE activity contained a fillet weld with a longitudinal was usually correlated with one or two heavily crack visible (Location 4). This crack was loaded semi-trailer trucks, this type of traffic evidently a product of the fabrication shop was very infrequent. Yet, it took no more than and produced no AE activity since no growth two and a half hours to excite the expected AE -------------W<H;--o<::{;l<l"r-i-ngT------------------------------------------------------ ------------------- --ae-t ----11-\0J--+ +vf-e y -- a io --f-l-a w --5-i-t e s.-------- ------ ------------------- ---- - - - - -- W<,;e[}lrf'lkf-1i f.ut 1 ctb e r i ll11 S-t w=-o-+-f-ttjh'llel-ttj1h-l'r -eee----jtffh8i-&s He i cates that Y At/5-Ya-1---1-w{j- -{)G -lillf'- -5--- test flaw detection model, the illustrations such as heavy proofing loads are not necessary in Figure 6, 7 and 8 show what happens when to excite AE activity from a crack which is we relax the rate criteria. These figures already experiencing sub-critical growth due to utilize a different display mode feature of service loading. In-service AE monitoring of a the AEWt. The monitor has provision for suspect area for a period of less than four connection of an x, y, oscilloscope for the hours should be sufficient to detect fatigue purpose of presenting source location infor- cracks on steel bridges subjected to normal mation. In the figures shown, the sensor structural loading patterns. Structural dispositions are represented by squares at each continuities which are harmless will not side of the display. A bright dot signifies generate any AE activity and will be ignored. an AE source location that satisfies the flaw detection model. Additional successive indications AE testing, incorporating the equipment and at the same location further brightens the spot. techniques described in this paper, has demonstrated three attributes which make it a desirable NDE method for inspection structures In Figure 6 we see two scope displays produced such as bridges: by the same data that produced the printouts in Figure 5. Here the model still requires a t"ate 6f 4 liz 6t" i1i het ft 6111 att] seut ce. Itt Figure 7 we see the result of playing back the same data as in Figures 5 and 6, however, the rate criteria has been defeated. The only restriction on data is the use of a ringdown count window (equivalent to an acceptance threshold). Here we see a great deal of clutter on the displays, most of which occurs in locations where no known flaw exists. Figure 8 shows similar results for the unflawed test area. The top display is produced with a normal 4 Hz rate criterion and a very wide open ringdown count window. The next two displays are the results for the same data with no rate test and varied ROC windows. Even though this area is probably flaw free, a multitude of AE sources results. The use of source location and fixed thresholds is obviously not sufficient to eliminate the fastener noise and allow reliable flaw detection. (1) Good operator productivity. ( ) Tile ability to detect and define bt idge defects (cracks). (3) The ability to compliment (confirm) other NDE methods.

Figure 1 Photograph Shows Typical Crack Site in Cross Beam of 1-24 Bridge Figure 2 Mobile AE Test Laboratory in Operation on 1-24 Bridge

AE FROM PRE AMP SET MAX. HIN. REJECT NO SET RAT[ (N,6 T (CRITERION) REJECT NO REJECT NO YES EXIT FLAW DETECTED Figure 3 AEWM PROCESSING FLOW CHART FOR FLAW DETECTION

Figure 4 AEWM In Operation During Bridge Monitoring Test

1 I 24 WEST 80 DB 12/9/82 #1,. c, 0 : s, 3 L s. 2 CHl UPPER FL NGE PULStR [) (] [ J [ J CH2 2130 CJ [ J Figure 5 AE Results For Location #1 Westbound

1-24 WEST LOC #1 12/10/82 Figure 6 AE Source Location Plots

1: L 100-1000 l-24 WEST LOC 01 12/1n/B2 l:l 500-5000 l-24 WEST LOC #1 12/10/82 \ Figure 7 AE Source Location Plots

l-24 WEST CONTROL 4:1, 16-4000 l-24 WEST CONTROL 1:1, 100-4000 l-24 WEST CONTROL 1:1, 500-4000 Figure 8 AE Source Location Plots