Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets

Similar documents
Supplementary Information. Stochastic Optical Reconstruction Microscopy Imaging of Microtubule Arrays in Intact Arabidopsis thaliana Seedling Roots

3D light microscopy techniques

High-resolution, low light-dose lightsheet microscope LATTICE LIGHTSHEET

Nature Methods: doi: /nmeth Supplementary Figure 1. sospim principle and representation of the sospim beam-steering unit.

More fancy SPIM, Even fancier SPIM

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Rapid three-dimensional isotropic imaging of living cells using Bessel beam plane illumination

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

3D light microscopy techniques

Nikon Instruments Europe

Instant super-resolution imaging in live cells and embryos via analog image processing

Reflecting optical system to increase signal intensity. in confocal microscopy

Spectral Imaging with the Opterra Multipoint Scanning Confocal

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup.

1 Co Localization and Working flow with the lsm700

ADVANCED METHODS FOR CONFOCAL MICROSCOPY II. Jean-Yves Chatton Sept. 2006

Rapid Non linear Image Scanning Microscopy, Supplementary Notes

Technology Note ZEISS LSM 880 with Airyscan

Heisenberg) relation applied to space and transverse wavevector

Contents. 1. Supplementary figures Supplementary Table Supplementary Methods Supporting movie list...

Development of a High-speed Super-resolution Confocal Scanner

Supplementary Figure S1: Schematic view of the confocal laser scanning STED microscope used for STED-RICS. For a detailed description of our

Supplemental Figure 1: Histogram of 63x Objective Lens z axis Calculated Resolutions. Results from the MetroloJ z axis fits for 5 beads from each

SUPPLEMENTARY INFORMATION

Shaping light in microscopy:

Fundamentals of Light Microscopy II: Fluorescence, Deconvolution, Confocal, Multiphoton, Spectral microscopy. Integrated Microscopy Course

Practical work no. 3: Confocal Live Cell Microscopy

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

Bioimage Informatics

Point Spread Function Estimation Tool, Alpha Version. A Plugin for ImageJ

Deep and fast live imaging with two-photon scanned light-sheet microscopy

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

D2.1 Operating 2D STED Microscope

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

arxiv: v2 [physics.ins-det] 18 Dec 2017

Chapter 3 Op,cal Instrumenta,on

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Adaptive optimisation of illumination beam profiles in fluorescence microscopy

Advanced Optical Microscopy lecture. 03. December 2012 Kai Wicker

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging.

Optimal 2D-SIM reconstruction by two filtering steps with Richardson- Lucy deconvolution. Supplementary information

Training Guide for Carl Zeiss LSM 5 LIVE Confocal Microscope

ANSWER KEY Lab 2 (IGB): Bright Field and Fluorescence Optical Microscopy and Sectioning

Leica SP8 TCS Users Manual

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Low Contrast Dielectric Metasurface Optics. Arka Majumdar 1,2,+ 8 pages, 4 figures S1-S4

INTRODUCTION TO MICROSCOPY. Urs Ziegler THE PROBLEM

Precision-tracking of individual particles By Fluorescence Photo activation Localization Microscopy(FPALM) Presented by Aung K.

Supplementary Information

Basics of confocal imaging (part I)

microscopy A great online resource Molecular Expressions, a Microscope Primer Partha Roy

Chapter 3 Op+cal Instrumenta+on

BASICS OF CONFOCAL IMAGING (PART I)

LEICA TCS SP5 AOBS TANDEM USER MANUAL

Supporting Information

RECENTLY, using near-field scanning optical

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

Multifluorescence The Crosstalk Problem and Its Solution

STORM/ PALM ANSWER KEY

Zero Focal Shift in High Numerical Aperture Focusing of a Gaussian Laser Beam through Multiple Dielectric Interfaces. Ali Mahmoudi

a) How big will that physical image of the cells be your camera sensor?

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

plasmonic nanoblock pair

Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

LSM 710 Confocal Microscope Standard Operation Protocol

Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By

Application Note. The New 2D Superresolution Mode for ZEISS Airyscan 120 nm Lateral Resolution without Acquiring a Z-stack

Εισαγωγική στην Οπτική Απεικόνιση

High resolution extended depth of field microscopy using wavefront coding

Things to check before start-up.

LSM 780 Confocal Microscope Standard Operation Protocol

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

Light Microscopy. Upon completion of this lecture, the student should be able to:

Boulevard du Temple Daguerrotype (Paris,1838) a busy street? Nyquist sampling for movement

Training Guide for Carl Zeiss LSM 510 META Confocal Microscope

Exercise 8: Interference and diffraction

AgilOptics mirrors increase coupling efficiency into a 4 µm diameter fiber by 750%.

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

We attempted to separate the two dyes by acquiring images using a single excitation wavelength and just two emission wavelengths.

Beam Shaping and Simultaneous Exposure by Diffractive Optical Element in Laser Plastic Welding

Last updated: May 2014 Y.DeGraaf

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

1.The Problem LIGHT-LEVEL LEVEL IMAGING. light-level level Cameras. 3. Solutions. 2. Low-light LOW-LIGHT

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

Laser Speckle Reducer LSR-3000 Series

Enhancement of the lateral resolution and the image quality in a line-scanning tomographic optical microscope

Observational Astronomy

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Transcription:

SUPPLEMENTARY MATERIAL Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light sheets Teng Zhao, Sze Cheung Lau, Ying Wang, Yumian Su, Hao Wang, Aifang Cheng, Karl Herrup, Nancy Y. Ip, Shengwang Du & M. M. T. Loy Supplementary Note 1 Supplementary Figure 1 Supplementary Figure 2 Supplementary Figure 3 Supplementary Figure 4 Supplementary Video 1 Supplementary Video 2 LBS1 and LBS2 designs System setups and control sequence Deconvolution in LBS2 Comparing the axial resolutions of LBS1, LBS2 and Gaussian lightsheet Photo-bleaching of LBSs LBS generation at different wavelengths with a fixed set of slit and annulus 4D multicolor imaging of endocytosis Tobacco BY-2 cells

Supplementary Note 1: LBS1 and LBS2 designs The input line-shape light can in principle be formed using a cylindrical lens or prism pair compressor without a slit, particularly for single color imaging. For multicolour application, however, the slit has the essential role to define the position of the line, independent of color. For this reason, a 200 micron width slit is used throughout this paper. LBS1 is designed to minimize photo-bleaching by reducing the number and intensities of sidebands, thus maximizing the portion of energy in the center peak, which can be achieved by increasing the width of the annulus, i.e., (NA max NA min ). On the other hand, longer light sheet is obtained with smaller NA max, albeit at the expense of a thicker sheet [1]. With this in mind, for LBS1 we used annulus with NA max =0.3 and NA min =0.112, as shown in Figure 1b. The resulting LBS was 15 µm long and having only two weak side-bands, which can be suppressed by the axial detection point spread function, yielding an overall single band PSF of 600 nm (FWHM) axial resolution with exceptionally low phototoxicity (See Supplementary Figure 4 for more detail.) This 15μm long LBS is sufficient for most cell imaging applications; if needed longer LBS can be crafted by scaling the annulus to smaller dimensions. It is also possible to use phase elements to create multi-foci thus double or triple the LBS length without any change in the cross-section of LBS. LBS2 aims to achieve higher axial resolution, using an annulus with NA max =0.4 and NA min =0.225, as shown in Figure 1c. The light sheet can propagate ~12 µm with a 400 nm thick central band, but flanked by multiple progressively weaker bands. The overall axial PSF consists of this ultrathin central band, plus two weaker side bands which can be removed by deconvolution (Supplementary Figure 2.) While the light sheet thickness is determined by the annulus, the width of the light-sheet (the dimension of LBS in x) is in proportion to the length of the single slit. The18mm long slit length used resulted in a 40μm wide light sheet that is sufficient for most cases. We found that a slit width of 200 µm appear to be optimal for our particular setup allowing over 50% of exit-fiber laser power to reach the sample for LBS1, or 38% for LBS2 at 488 nm (47% and 35% at 560nm). Multicolor imaging can be done with a fixed set of slit and annulus. We note that, non-diffracting patterns in any shape can be mathematically expressed in circular coordinates 2,3 (i.e. Bessel beams) or elliptical coordinates (i.e. Mathieu beams 4 ), and it is possible to extend the depth of any pattern by producing angular spectrum in the k-space with an annular mask 5. LBS is one of the examples to produce extend light sheet with a pattern (a slit in this case) and an annulus and is thus given the name line Bessel beam. Reference: [1] Liang Gao, Lin Shao, Bi-Chang Chen & Eric Betzig, Nature Protocols 9, 1083 1101 (2014). [2] Z. Bouchal, Opt. Lett. 27(16) (2002)

[3] J. Durnin, J. Opt. Soc. Am. A, 4, 651 (1987). [4] J. C. Guiterrez-Vega et al. Opt. Commun., 195 35-40 (2001) [5] W. T. Welford, J. Opt. Soc. Am., 50(8), 749-753 (1960);

Supplementary Figure 1 System setups and control sequence. (a) System schematics of a LBS microscope. The fiber output was collimated and shaped by a pair of cylindrical lenses to maximize output through a 200 µm slit. An f=500 mm lens is used to perform Fourier transform after the single silt, and project the diffraction pattern onto an annulus. The image of the annulus is zoomed by 2.5 times via a telescope system before projected onto the back focal plane of excitation objective. The LBS is produced at sample plane 30 to the plane of coverslip, and right in the focal plane of the detection objective. With the relative position between the emission and detection objectives fixed, the coverslip is driven by a piezo stage, allowing specimen to be scanned step by step. The fluorescent emission is collected by the detection objective and captured by a scmos camera after the multi-band emission filter. (b) The triggering sequence used in LBS imaging. Camera running in synchronous readout mode generates high output during the global exposure and low during data transfer. Laser controlled by an AOTF is turned on only during global exposure. For multicolor imaging, the wavelength is switched for adjacent frames. The piezo stage triggered by the falling of global exposure moves a step forward after both colors are imaged.

Supplementary Figure 2 Deconvolution in LBS2. PSF of LBS2 has multiple peaks, which can be removed using deconvolution. (a) An image of a dye molecule scanned with LBS2 showing the shape with multi peaks in axial PSF. (b) After performing Lucy-Richardson deconvolution to the entire 3D stack, the side peaks in the PSF can be removed. (c) The axial plot of the PSFs before and after deconvolution. (d) A non-deconvoluted cross-section of a fixed HT22 cell stained with Alexa488 anti-tubulin (Green) and Alexa560 anti-tom20 (mitochondria outer membrane, Red) imaged by LBS2. (e) The same region of (d) after deconvolution. Scale bars: 500 nm in a and b; 5 µm in d and e.

Supplementary Figure 3 Comparing the axial resolution of LBS1, LBS2 and Gaussian lightsheet with fixed HT22 cells double stained with Alexa488 anti-tubulin (Green) and Alexa560 anti-tom20 (mitochondria outer membrane, Red). The sample is scanned by LBS1, LBS2 and Gaussian light-sheets, as shown in (a), (b) and (c) respectively. All scanning is done with 100 nm step size. Deconvolution is applied to obtain (b) in order to remove the special structure in the PSF. In each image, upper panel shows the lateral projection (towards the coverslip), and the lower panel shows the axial cross section along the dotted blue line in the upper panel. Gaussian light-sheet (600nm FWHM thickness, positioned for best resolution at the cell bottom on the coverslip) generates obviously more background than LBS at positions above the cell bottom. (d) The measured optical transfer function (OTF) of the imaged microtubule (green channel), which confirms that LBS2 has the best axial resolution (2.5 µm -1 or 400 nm), and LBS1 has better axial resolution (1.75 µm -1 or 570 nm) and much lower background than Gaussian light-sheets (1.4 µm -1 or 700 nm). Scale bars: 5 µm.

Supplementary Figure 4 Photobleaching of LBSs. Microtubules in HT22 cells are continuously scanned by LBS over a range of 40 µm using 200 nm step size and 30 ms exposure time at each layer. The total laser power reaching the sample for LBS1 and LBS2 was 24.8 µw and 26.6 µw so that the peak intensity is the same for both LBSs. The cells with similar size, morphology and brightness were selected for imaging. The mean signal to noise ratio at any given time point was calculated according to a specified region from the slice of image at the middle of a cell. (a) The slices used to calculate SNR from the first scan (left) and the 100 th scan (right) for LBS1 (upper) and LBS2 (lower). SNR for each time point is calculated based on the mean value of the boxed region (marked as signal ) to the S.D. of the background region (marked as background ). Figures are displayed in the same dynamic range with Gem lookup table. (b) The plot of descending SNR for LBS1 and LBS2 over 100 times of 3D scans. LBS1 with its more energy localized to the central peak, exhibit a lower rate of bleaching compared to LBS2 where more power is required to have the same SNR. Both LBSs shows a low rate of bleaching in general. (c) The first time point (left) and the 16 min 30 s (the 1000 th time point) of a live plant root BY-2 cells imaged by LBS1 using 20 µw laser power at 100 frame per second, showing the small SNR reduction after long term imaging.

Supplementary Video 1 LBS generation at different wavelengths with a fixed set of slit and annulus. Simulation confirms that the same LBS pattern can be produced at any wavelength from 405nm to 1100nm using a fixed set of single slit and annulus. Supplementary Video 2 4D multicolor imaging of endocytosis Tobacco BY-2 cells. Green: AtSCAMP3-GFP; Red: FM 4-64. Video is taken by LBS1 and recorded at a rate of 100Hz per frame per color. Each volume stack contains 50 two-color slices yielding a time resolution of 1s. Scale bars: 5µm.