California Instruments BPS Series kva V A / Phase. Overview. High Power AC Source. Expandable Power Levels.

Similar documents
California Instruments MX Series II kva V A / Phase. Overview

Configurations The RS90 delivers up to 90 kva of AC or AC + DC power. In DC mode, 50% of the AC power level is available.

California Instruments MX Series II kva V A / Phase. Overview

In addition to these standard waveforms, user defined waveform can be downloaded over the bus.

Applications. Other applications include:

California Instruments Ls Series VA V A kva Programmable AC Power Source / Analyzer

California Instruments RP Series 2000 VA V 3 45 A. General purpose AC power sources

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Advanced Test Equipment Rentals ATEC (2832)

Programmable AC Power Source Model 9801

Parallel AMX AC Power Systems

AMX Series. Precision AC Test Power Single and Three Phase Linear AC Power Sources. Parallelable to 30 kva. T h e P o w e r o f E x p e r t i s e

5V SERIES DC LOADS 5V SERIES DC LOADS. Key features:

PROGRAMMABLE AC POWER SOURCE

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

EAC/AFV-P SERIES. High performance programmable AC power source 600 VA to 5 kva only in 2 U or 5 U

N432A Thermistor Power Meter DATA SHEET

AC/DC Power Sources ACS Series

ASX Series. High-Density AC Test Power Single and Three Phase Switchmode AC Power Sources. T h e P o w e r o f E x p e r t i s e.

AC/DC Power Sources ACS Series

Model 865 RF / Ultra Low Noise Microwave Signal Generator

RS Series AC and DC Power Source User Manual

Agilent N3300 Series DC Electronic Loads

MX Series AC and DC Power Source User Manual Series I / Series II

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

The series allows users to compose. amplify the analog signal from arbitrary signal generator. Thus, it is capable of simulating the

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Advanced Test Equipment Rentals ATEC (2832)

Model 865-M Wideband Synthesizer

250 / 500 Vdc. Advanced Features. Performance. Reliance. Brilliance.

Sorensen HPD Series 300 W 5 20 A. 300 Watt DC Power Supply with Near-Linear Performance V. with automatic crossover and mode indication

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Burst mode - This is incorporated to simulate simultaneous analog input. Compatible with a range of Application Development Environments

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Arbitrary/Function Waveform Generators 4075B Series

HMC-T2240. Synthesized Signal Generator, 10 MHz to 40 GHz

AC POWER SOURCE CATALOG

Because you can t afford downtime

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

Designed with self-diagnostic routine and protections

PROGRAMMABLE AC POWER SOURCE MODEL 6500 SERIES MODEL 6500 SERIES. Programmable AC Power Source. Key Features:

3B SERIES AC & DC LOADS

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

Models 31120/31120A/31180/31180A Programmable AC Power Source

WaveStation Function/Arbitrary Waveform Generators

EL-AC Electronic Load

IT7600 High Power Programmable AC power supply

AC POWER SYSTEMS CATALOG

2-channel models. 4-channel models

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

500 khz / 1 MHz Precision LCR Meter Models 894 & 895

Model 865-M Wideband Synthesizer

Model 61511/61512/61611/61612

3 x 30 kva AC POWER SOURCE PCU-3x30000-AC/DC-300V-100A-2G-HP RS232

Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED

Agilent 34405A Multimeter

Lx \ Ls Series AC Power Source User Manual

APPH6040B / APPH20G-B Specification V2.0

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Instant value. Extreme values ors statistic measurements

MX15 Series AC and DC Power Source User Manual

WaveStation Function/Arbitrary Waveform Generators

Universally Applicable for Piezoelectric Measuring Technology. Technical Data. Charge Input. Extreme values ors statistic measurements

Lx \ Ls Series II AC Power Source User Manual

Agilent U2500A Series USB Simultaneous Sampling Multifunction DAQ Devices

Charge Meter. Electronics & Software. Universally Applicable for Piezoelectric Measuring Technology. Type 5015A...

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

WaveStation Function/Arbitrary Waveform Generators

2.9GHz SPECTRUM ANALYZER

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Spectrum Analyzer R&S FS300

Model 7000 Series Phase Noise Test System

HMC-T2100B. Portable & Battery Operated! OBSOLETE PRODUCT. Portable Synthesized Signal Generator, 10 MHz to 20 GHz

RS Series AC and DC Power Source User Manual

DC 4Q POWER AMPLIFIER 200kW 2 RANGES HIGH POWER RS232

RS232 AC-DC VOLTAGE POWER AMPLIFIERS PCU-10K / 15K / 20K / 24K-AB/4G/HP PERFORMANCES APPLICATIONS DESCRIPTION COMMERCIAL REFERENCES

Agilent U2300A Series USB Modular Multifunction Data-Acquisition Devices

Models 296 and 295 combine sophisticated

True RMS Bench Multimeter 5492B

R&S SMB100N SIGNAL GENERATOR

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

Phase Matrix, Inc. 545B 548B. Phase Matrix, Inc. EIP 545B and 548B CW Frequency Counters. Instruments You Can Count On

Agilent 6800 Series AC Power Source/Analyzer

Keysight 34401A Multimeter

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES. Regenerative Grid Simulator. Key Features

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

DCR DC Output Module

n DC Voltage Measurement (DCV) 7461A n AC Voltage Measurement (ACV, ACV (AC+DC)) 7451A 7461A/7451A Additional error depending on the integration time

Model 845-M Low Noise Synthesizer

POWER AMPLIFIERS 4 QUADRANTS 3x500 VA to 3x1500 VA - THREE-PHASES

SDM3045X Digital Multimeter. DataSheet

Chapter 6 Specifications

Keysight Technologies AC6800B Series Basic AC Power Sources. Data Sheet

DCPS Programmable DC Power Supply

Transcription:

California Instruments Overview High AC Source Expandable Levels Remote Control 30 180 kva 150 400 V 0 400 A / Phase 208 230 400 480 Introduction The consists of multiple high power AC power systems that provide controlled AC output for ATE and product test applications. This high power AC test system covers a wide spectrum of AC power applications at an affordable cost. Using state-of-the-art PWM switching techniques, the combines compactness, robustness and functionality in a compact floor-standing chassis, no larger than a typical office copying machine. This higher power density has been accomplished without the need to resort to elaborate cooling schemes or additional installation wiring. Simply roll the unit to its designated location (using included casters), plug it in, and the is ready to work for you. Simple Operation The can be operated completely from its menu driven front panel controller. A backlit LCD display shows menus, setup data, and read-back measurements. IEEE-488, RS232C, USB and LAN remote control interfaces and instrument drivers for popular ATE programming environments are available. This allows the BPS Series to be easily integrated into an automated test system. Configurations The BPS is capable of delivering 30, 45, 75, 90, 150 or 180kVA of AC power. The 30 and 45kVA models come as dedicated single or three output while the 75, 90, 150 and 180kVA models are dedicated three. For higher power requirements, simply parallel the BPS in multi-cabinet configuration. Multi cabinet systems always operate in three output mode commonly found in power systems. Product Evaluation and Test Increasingly, manufacturers of high power equipment and appliances are required to fully evaluate and test their products over a wide range of input line conditions. The built-in output transient generation and read-back measurement capability of the offers the convenience of a powerful, and easy to use, integrated test system. Avionics With an output frequency range to 819 Hz, the is well suited for aerospace applications. Precise frequency control and accurate load regulation are key requirements in these applications. The available remote control interfaces and SCPI command language provide for easy integration into existing ATE systems. The eliminates the need for several additional pieces of test equipment, saving cost and space. Instrument drivers for popular programming environments such as National Instruments LabView are available to speed up system integration. Choice of voltage ranges Standard voltage ranges are 150V L-N (259V L-L) and 300V (519V L-L) and are direct coupled output. For applications requiring more than 300V L-N (or 519V L-L), the optional -HV output transformer provides a third additional 400V L-N and 693 V L-L output range which is internal to the AC chassis. No external magnetics modules are required. Multi-Box Configurations For high power applications, two BPS75 or BS90 chassis can be combined to provide 150kVA or 180kVA of output power. For higher power requirement please contact sales for custom configurations. AMETEK Programmable 9250 Brown Deer Road San Diego, CA 92121-2267 USA 858.458.0223 CompuMess sales@programmable.com Elektronik 06042013 217 mit System CompuMess Elektronik GmbH Lise-Meitner-Straße 4 D-85716 Unterschleißheim Telefon (089) 321501-0 Telefax (089) 321501-11 info@compumess.de www.compumess.de www.netzteile.de

Simple transition from R&D to Manufacturing. The California Instruments Mx and RS Series are high performance, feature rich Research and Development solutions. That level of advanced performance is not always required in production and lab environments. Since the BPS shares common code structure and performance characteristics as the Mx and RS the BPS is ideally suited to easily transition into cost effective production solutions. High Crest Factor With a crest factor of up to 4.5, the AC source can drive difficult nonlinear loads with ease. Since many modern products use switching power supplies, they have a tendency to pull high repetitive peak currents. Remote Control remote control interfaces allow programming of all instrument functions from an external computer. The popular SCPI command protocol is used for programming. Application Software Windows application software is included. This software provides easy access to the power source s capabilities without the need to develop any custom code. The following functions are available through this GUI program: transient programs current waveforms. traffic to and from the AC Source to help you develop your own test programs. - AC Transient Generation The controller has a powerful AC transient generation system that allows complex sequences of voltage and frequency to be generated. This further enhances the BPS s capability to simulate AC line conditions and disturbances. Transient generation is controlled independently yet time synchronized on all three s. Accurate angle control and synchronized transient list execution provide unparalleled accuracy in positioning AC output events. Transient programming is easily accomplished from the front panel where clearly laid out menu s guide the user through the transient definition process. The front panel provides a convenient listing of the programmed transient sequence and allows for transient execution Start, Stop, Abort and Resume operations. User defined transient sequences can be saved to non-volatile memory for instant recall and execution at a later time. The included Graphical User Interface program supports transient definitions using a spreadsheet-like data entry grid. A library of frequently used transient programs can be created and saved using this GUI program. Transient List Data Entry from the front panel. Transient List Data Entry in GUI program. 218 www.programmable.com

30 180 kva - Measurement and Analysis The is much more than a programmable AC power source. It also incorporates an advanced digital signal processor based data acquisition system that continuously monitors all AC source and load parameters. This data acquisition system forms the basis for all measurement and analysis functions. These functions are accessible from the front panel and the remote control interface for the. Conventional Measurements Common AC measurement parameters are automatically provided by the data acquisition system. These values are displayed in numeric form on the front panel LCD display. The following measurements are available: Frequency, Vrms, Irms, Ipk, Crest Factor, Real (Watts), Apparent (VA) and Factor. Acquired Current waveform (BPS Display). Measurement data for single (BPS Display). Measurement data for all three s (BPS Display). Waveform Acquisition The measurement system is based on real-time digitization of the voltage and current waveforms using a 4K deep sample buffer. This time domain information provides detailed information on both voltage and current waveshapes. Waveform acquisitions can be triggered at a specific angle or from a transient program to allow precise positioning of the captured waveform with respect to the AC source output. The front panel LCD displays captured waveforms with cursor readouts. The included GUI program also allows acquired waveform data to be displayed, printed, and saved to disk. Acquired three voltage waveforms display on PC. 858.458.0223 sales@programmable.com 219

: Specifications Operating Modes AC Mode Output Frequency Phase Outputs Total Load Factor AC Mode Voltage AC Range: 16.00-819.0 Hz, -LF Option: 16.00-500.0 Hz, Resolution: 0.01 Hz: 16.00-81.91 Hz, 0.1 Hz: 82.0 Hz - 819.1 Hz 1 or 3 Neutral: Floating, Coupling: DC (except for -HV option) Please specify Single (-1) or Three Phase (-3) for BPS30 and BPS45 at time of order. BPS30-1/3; 30kVA, BPS45-1/3: 45kVA, BPS75-3: 75kVA, BPS90-3: 90kVA, BPS150-3:150kVA, BPS180-3, 180kVA 0 to unity at full output current Voltage Ranges Range V Low V High Load Regulation < 0.25 % FS to 100 Hz, < 0.5 % FS 100 Hz to 819 Hz AC 0-150 V 0-300 V Line Regulation < 0.1% FS for 10 % line change External Sense Harmonic Distortion (Linear) DC Offset Load Regulation External Amplitude Modulation Voltage slew rate AC Mode Current Voltage drop compensation (5% Full Scale) Less than 0.5% from 16-66 Hz, Less than 1% from 66-500 Hz, Less than 1.25% above 500 Hz < 20 mv 0.25% FS @ - 100 Hz, 0.5% FS > 100 Hz Depth: 0-10 %, Frequency: DC - 2 KHz 200 μs for 10% to 90% of full scale change into resistive load, 0.5V / μsec Output Model BPS30-1/3 BPS45-1/3 BPS75 BPS90 BPS150 BPS180 30 KVA 45 KVA 75 KVA 90 KVA 150 KVA 180 kva BPS30-1 V Lo:200 A V Hi: 100A Single BPS30-3 V Lo: 66.7A V Hi: 33.3A per 3 BPS45-1 V Lo:300 A V Hi: 150A Single BPS45-3 V Lo: 100 V Hi: 50A per 3 BPS75 V Lo: 166A V Hi: 83A per BPS90 V Lo:200A V Hi: 100A per Note: Constant power mode provides increased current at reduced voltage. See chart below BPS150 V Lo:332A V Hi: 166A per BPS180 V Lo:400A V Hi: 200A per Peak Repetitive AC Current 4.5 x RMS current for BPS30, 3.0 x RMS current for BPS45, 3.6 x RMS current for BPS75 and 3.0 x RMS current for BPS90. BPS150 is 2x BPS75 and BPS180 is 2x BPS90 Programming Accuracy Voltage (rms): ± 0.3 Vrms, Frequency: ± 0.01 % of programmed value, Current Limit: - 0 % to + 5 % of programmed value + 1A, Phase: < 0.5 + 0.2 / 100 Hz with balanced load Programming Resolution Voltage (rms): 100 mv, Frequency: 0.01 Hz from 16-81.91 Hz, 0.1 Hz from 82.0-819 Hz, Current Limit: 0.1 A, 3 mode, 1.0 A, 1 mode, Phase: 0.1 Constant AC Mode - Available Max. AC Current Current (RMS) 125% 100% 50% Full 20% 10% 50% 80% 100% Voltage (RMS) Note: Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25 ± 5 C. Unless otherwise noted, specifications are per for a sinewave with a resistive load and apply after a 30 minute warm-up period. For three configurations, all specifications are for L-N. Phase angle specifications are valid under balanced load conditions only. 2009 AMETEK Programmable All rights reserved. AMETEK Programmable is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen, California Instruments, and Ten are trademarks of AMETEK Inc., registered in the U.S. 220 www.programmable.com

: Specifications 30 180 kva Measurement Measurements - Standard (AC Measurements) Parameter Frequency RMS Voltage Range 16-100 Hz 100-820 Hz Accuracy* 0.01% + 0.01 Hz 0.05 V + 0.02% (±) 0.1 V + 0.02% Resolution* 0.01 Hz / 0.1 Hz RMS Current Peak Current Crest Factor Real Apparent Factor 0-400 V 0-300 A 0-800 A 0.00-6.00 90 kw 90 kw 0.00-1.00 0.0-360.0 0.15 A +.02% 0.3 A +.02% 0.15 A + 0.02% 0.3 A +.02% 0.05 0.05 30 W + 0.1% 60 W + 0.1% 30 VA + 0.1% 60 VA + 0.1% 10 mv 10 ma 10 ma 0.01 10 W 10 VA 0.01 0.1 0.01 0.02 Phase 2.0 3.0 * Measurement system bandwidth = DC to 6.7 khz. Accuracy specifications are valid above 100 counts. Current and Accuracy and Range specifications are times three for BPS 150 and BPS180 in single mode. PF accuracy applies for PF > 0.5 and VA > 50 % of range Protection Over Load Over Temperature Storage Non Volatile Mem. storage Waveforms Waveform Types System Interface Inputs Outputs Remote Control IEEE-488 Interface RS232C Interface LAN ( option ) USB Output Relay AC Input Voltage Constant Current or Constant Voltage mode Automatic shutdown 16 instrument setups, Std: Sine Wave Remote shutdown Function Strobe / Trigger out IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax 9 pin D-shell connector (Supplied with RS232C cable) Ethernet Interface: 10BaseT, 100BaseT, RJ45 Version: USB 1.1; Speed: 460 Kb/s maximum Push button controlled or bus controlled output relay Must be specified at time of order. All inputs are L-L, 3ø, 3 wire + Gnd. 208 ± 10% VAC, 230 ± 10% VAC, 400 ± 10% VAC, 480 ± 10% VAC Input Line Current (per ) BPS30-1/3 BPS45-1/3 BPS75 BPS90 BPS150 BPS180 116 ARMS @ 187 VLL 105 ARMS @ 207 VLL 60 ARMS @ 360 VLL 50 ARMS @ 432 VLL 175 ARMS @ 187 VLL 157 ARMS @ 207 VLL 90 ARMS @ 360 VLL 75 ARMS @ 432 VLL 285 ARMS @187 VLL 256 ARMS @ 207 VLL 147 ARMS @ 360 VLL 122 ARMS @ 432 VLL 350 ARMS @ 187 VLL 314 ARMS @ 207 VLL 180 ARMS @ 360 VLL 150 ARMS @ 432 VLL Each BPS75 chassis requires its own AC service. Total Line currents are 2 x BPS75 Each BPS90 chassis requires its own AC service. Total Line currents are 2 x BPS90 Line Frequency 47-63 Hz Efficiency 85 % typical Factor 0.95 typical AC Service Inputs/Outputs Rear panel connection Regulatory IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements EMI CISPR 11, Group1, Class A Connectors All remote interface connections available from the rear panel. Physical Dimensions BPS30/45 Dimensions Height: 50 1270 mm, Width: 28.75 731mm, Depth: 34.5 876mm BPS30/45 Weight Per Chassis: Net: 1150 lbs / 522 Kg approximately, Shipping: 1231 lbs / 560 Kg approximately BPS75/90 Dimensions Height: 76 1930 mm, Width: 32.0 812mm, Depth: 40.0 1016mm BPS75/90 Weight Per Chassis: Net: 1650 lbs / 748 Kg approximately, Shipping: 1731 lbs / 785 Kg approximately Chassis Casters and forklift openings. Vibration and Shock Designed to meet NSTA project 1A transportation levels. Units are shipped in wooden crate with forklift slots Air Intake/Exhaust Forced air cooling, front air intake, rear exhaust Operating Humidity 0 to 95 % RAH, non condensing Temperature Operating: 0 to 40 C (30 C max in CP mode), Storage: -20 to +85 C 858.458.0223 sales@programmable.com 221

Supplied with Standard: User/Programming Manual and Software on CD ROM. RS232C serial cable. Input Voltage Settings Specify input voltage (L-L) setting for each BPS system at time of order: 208 Configured for 208 V ±10 % L-L, 4 wire input. 230 Configured for 230 V ±10 % L-L, 4 wire input. 400 Configured for 400 V ±10 % L-L, 4 wire input. 480 Configured for 480 V ±10 % L-L, 4 wire input Standard Model Options - LF Limits maximum frequency to 500 Hz. -LAN -HV Ethernet Interface. Adds 400 V L-N AC-only output range. Packaging and Shipment All BPS systems are packaged in re-usable protective wooden crates for shipment. BPS30/45 Dimensions - single chassis 28.75 [730.25] 48.125 [1222.4] Rear View Front View 1.95 [49.53] BPS75/90 Dimensions - single chassis 222 www.programmable.com CompuMess Elektronik GmbH Lise-Meitner-Straße 4 D-85716 Unterschleißheim Telefon (089) 321501-0 Telefax (089) 321501-11 info@compumess.de www.compumess.de www.netzteile.de CompuMess Elektronik mit System