SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

Similar documents
SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

SINVERT. Technical requirements for medium-voltage transformers for use with SINVERT central inverters. Application manual 04/2012

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

2015 / 9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. Radio and Telecommunications Terminal Equipment

SINAMICS drives. SINAMICS DCM as a DC voltage source. Application. Answers for industry. Edition 01/2014

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives

R&TTE Testing For EU Market

Technical Documentation

TETRIS 1000 High Impedance Active Probe. Instruction Manual


SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

SIMATIC Vision Sensor SIMATIC VS130-2 and VS 130-2vcr

Technical Specification

SINAMICS DCM. DC converter Application - 12-pulse parallel connection with decoupled interphase transformer. Introduction 1

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

TV Transmitter. User Guide Master

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SINAMICS drives SINAMICS DCM. Commutation reactors. Operating Instructions. Answers for industry. Edition 11/2013

COMMON REGULATORY OBJECTIVES FOR WIRELESS LOCAL AREA NETWORK (WLAN) EQUIPMENT PART 2 SPECIFIC ASPECTS OF WLAN EQUIPMENT

AN0509 swarm API Country Settings

TK 100 Probe Calibrator. Instruction Manual

National Voluntary Laboratory Accreditation Program

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

ON!Track smart tag AI T380. English. Printed: Doc-Nr: PUB / / 000 / 02

TECHNICAL SPECIFICATION

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

IR UK Interface Requirement 2095 High Duty Cycle Network Relay Points (NRPs)

UK Interface Requirement 2006

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Ten Turns Servo or Bushing Mount Hall Effect Sensor in Size 09 (22.2 mm)

TECHNICAL SPECIFICATION

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

IR UK Interface Requirement 2084

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

National Voluntary Laboratory Accreditation Program

Audio/video, Information and Communication Technology Equipment - Part 1:

SIMATIC Ident. RFID systems SIMATIC RF200 IO-Link V1.1. Introduction 1. Description. System overview. Planning an RF200 IO-Link system 4

16F.,No.30, Beiping E.Rd.,Zhongzheng Dist., Taipei City 100, Taiwan Manufacturer : MUZEE Corporation

UK Interface Requirement 2007

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

ETSI EN V1.1.1 ( )

ETSI EN V1.1.1 ( )

ETSI EN V1.3.1 ( ) Harmonized European Standard (Telecommunications series)

ETSI EN V1.1.1 ( )

EU Declaration of Conformity Annex

User Manual. MITSUMI WiFi Module MODEL DWM-W081

ETSI EN V1.2.1 ( )

UK Interface Requirement 2005

ANCOM s Laboratory for Electromagnetic Compatibility and Radio Equipment Testing

E205 Long Range Wireless Modem V1.0 Data Sheet

EMC aspects associated to 5G networks

Instruction manual ADN-W AM. Antenna Module

ECOS SRIF Operating Instructions

Interface Requirement 2019

Astra-R Kit Wireless Alarm System Operation Manual

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

Radio to radio repeater. airrepeater INSTRUCTIONS MANUAL M A

IR UK Interface Requirement 2096

AC 3. Active Antenna Combiner. Instruction manual

ETSI EN V1.2.1 ( )

ETSI EN V1.1.2 ( ) Harmonized European Standard

ETSI EN V1.2.1 ( )

ANSI-ASQ National Accreditation Board/ACLASS

ETSI EN V1.1.1 ( )

TR-62D. Data Sheet. Transceiver Module for Wireless M-Bus. Preliminary MICRORISC s.r.o. DSTR62D_ Page 1

Silicon PIN Photodiode, RoHS Compliant

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

ETSI TS V1.1.1 ( )

Silicon PIN Photodiode

TR-62D. Data Sheet. Transceiver Module for Wireless M-Bus. Preliminary MICRORISC s.r.o. DSTR62D_ Page 1

Silicon PIN Photodiode, RoHS Compliant

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

P-Channel 20-V (D-S) MOSFET

IR Sensor Module for Remote Control Systems

Installation Instructions RF identification system Read/write head ANT430 ANT431

Operation and Maintenance Manual

Resusci Anne Advanced SkillTrainer

WIRELESS DMX TRANSMITTER OR RECEIVER BOX (AIRDMX) USER GUIDE December 2012 Version 1.0

Small Signal Fast Switching Diode

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

Silicon PIN Photodiode

TETRIS User's Guide. High Impedance Active Probe DO177-1

High Voltage Glass Passivated Junction Plastic Rectifier

Low-Voltage, Low R ON, SPDT Audio Switch with Negative Swing Capability

WML- 46### User Manual

Space-Friendly. Mini Active GPS-L1 Patch Antenna. minipatch-l1. Product Datasheet Rev. A/2017. Intended to cover all CubeSat Project needs.

INSTRUCTIONS MODELS AVX-CA-SEMA TEST JIG FOR USE WITH AVTECH AVR-EB2A-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

NI PXI-2521 Specifications 40-Channel DPST Relay Module

SOM i.mx6. Regulation Information. Simple. Robust. Computing Solutions. Rev 1.1

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

WirelessUSB LS Radio Module FCC Testing & Verification - AN4006

IR Sensor Module for Remote Control Systems

JACK 5.8. User manual. English. Version /2016

INSTRUCTIONS MODEL AVX-S1-P0D-MS1A PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

USRP Contents. Definitions. Conditions SPECIFICATIONS. Software Defined Radio Device

Transcription:

SIMATIC RTLS Localization systems (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Agilion products Note the following: Trademarks WARNING Agilion products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Agilion. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. 2 Device manual, 10/2018, C79000-G8976-C518-01

Agilion GmbH Blankenauer Straße 74 09113 Chemnitz Germany Tel.: +49 - (0)371-45 00 48-0 Fax.: +49 - (0)371-45 00 48-11 www.agilion.de service@agilion.de Management: Andreas Werner Johannes Waldhör Sven Sieber HR B 21249 Chemnitz USt.-IdNr.: DE236591552 Device manual, 10/2018, C79000-G8976-C518-01 3

Table of contents English 1 Mechanics and connectors... 5 1.1 Dimensions... 5 1.2 Displays... 6 1.3 P200 socket... 6 1.4 P800 socket... 7 1.5 P201 socket... 7 2 Technical specifications... 8 2.1 Connections and power supply... 8 2.2 Wireless... 8 2.3 Environment... 8 3 Approvals... 9 3.1 EU declaration of conformity... 9 3.2 RoHS... 9 3.3 RED... 10 3.3.1 Protection of health and safety... 10 3.4 Recycling and disposal... 11 4 Device manual, 10/2018, C79000-G8976-C518-01

1 Mechanics and connectors 1.1 Dimensions The two antennas are arranged standing up on the top side of the PCB. P200 P800 P201 P200 P800 Device manual, 10/2018, C79000-G8976-C518-01 5

1.2 Displays Display (LED) Description Flashing green Off Operating display Device not in operation 1.3 P200 socket For connecting the HWL scanner Type: DF40HC(2.5)-20DS-0.4V(51) Pin Description/function 1 Not occupied 2 Ground 3 Not occupied 4 Not occupied 5 Not occupied 6 Not occupied 7 Not occupied 8 Ground 9 Not occupied 10 RTS 11 3.4 V scanner operating voltage 12 CTS 13 3.4 V scanner operating voltage 14 TXD 15 3.4 V scanner operating voltage 16 RXD 18 Ground 19 Ground 20 Ground 6 Device manual, 10/2018, C79000-G8976-C518-01

1.4 P800 socket Internal interface for production and manufacturing test, do not use. 1.5 P201 socket TMA connector Type: JST BM08B-SRSS-G-TBT Pin Description/function 1 Not occupied 2 RTS 3 CTS 4 TXD 5 RXD 6 Power In +5V 7 Not occupied 8 Ground Device manual, 10/2018, C79000-G8976-C518-01 7

2 Technical specifications 2.1 Connections and power supply Connections and power supply Voltage Energy intake 5 V DC (±100 mv) Max. 1 A (including scanner) 2.2 Wireless Wireless PULSE (localization) Wireless process Frequency range IEEE 802.15.4-2011 UWB 3100 MHz 4800 MHz 6000 MHz 7000 MHz Transmit power Antenna 0.037 mw (-41.3 dbm/mhz) UWB antenna integrated Wireless PHASE (data transmission and optional localization) Wireless process IEEE 802.15.4 Frequency range Bandwidth Transmit power Antenna 2.40 2.48 GHz ISM band 2 MHz; data transmission on 802.15.4; channels can be set Max. 4 dbm (can be set) 2.4 GHz antenna integrated 2.3 Environment Environment and dimensions Dimensions of PCB Weight 32.5 x 62 x 18.6 mm Approx. 9 g Temperature range 0 +50 8 Device manual, 10/2018, C79000-G8976-C518-01

3 Approvals 3.1 EU declaration of conformity The EU declaration of conformity is available to all responsible authorities at: Agilion GmbH Blankenauer Straße 74 09113 Chemnitz Germany You can find the current EU declaration of conformity for this product on the Internet pages under Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/14970/cert) The products described in this document meet the requirements of the following EU directives: RoHS directive 2011/65/EU Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 01/07/2011, pages 88-110 Radio Equipment Directive 2014/53/EU (RED) Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market; official journal of the EU L153, 22/05/2014, pages 62 106 3.2 RoHS RoHS directive (restriction of the use of certain hazardous substances) The products described in these operating instructions meet the requirements of the EU directive 2011/65/EU for the restriction of the use of certain hazardous substances in electrical and electronic equipment. Applied standard: EN 50581 Technical documentation for the assessment of electrical and electronic products with respect to restriction of hazardous substances Device manual, 10/2018, C79000-G8976-C518-01 9

3.3 RED 3.3.1 Protection of health and safety The products described in this document meet the requirements of the applied standards: Article 3 (1) a) Protection of health and safety EN 62368-1 Equipment for audio, video, information and communication technology Part 1: Safety requirements EN 62311 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz 300 GHz) The products described in these operating instructions meet the requirements of art. 3 (1) b) EMC harmonized standards: ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems ETSI EN 301 489-33 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 33: Specific conditions for ultrawideband (UWB) devices EN 55011 Industrial, scientific and medical (ISM) radio-frequency equipment Electromagnetic disturbance characteristics Limits and methods of measurement EN 55032 Class A, Class B Electromagnetic compatibility of multimedia equipment Emission requirements EN 55035 Electromagnetic compatibility of multimedia equipment - Immunity requirements EN 61000-6-1 Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments EN 61000-6-2 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments 10 Device manual, 10/2018, C79000-G8976-C518-01

EN 61000-6-3 Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments EN 61000-6-4 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments Art. 3 (2) Efficient use of the radio spectrum ETSI EN 300 328 Broadband transmission systems Data transmission equipment operating in the 2.4 GHz ISM band and using broadband modulation techniques. Harmonized EN covering the essential requirements of article 3.2 of the EU Directive 2014/53/EU ETSI EN 302 065-2 Short-range devices (SRD) using ultra-wideband (UWB) technology - Harmonized EN covering the essential requirements of article 3.2 of the EU directive 2014/53/EU, Part 2: Requirements for ultra-wideband location monitoring Note The specified approvals apply only when the corresponding mark is printed on the device. 3.4 Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations. Device manual, 10/2018, C79000-G8976-C518-01 11